HomeMy WebLinkAbout12100070 Miscellaneous Eng. Number 53025311 April 17, 2013 Page 1 of 2 AMERICAN TOWER' CORPORATION Structural Evaluation ATC Site Number.& Name 92397, North Carmel,IN Carrier Site'Number& Name N/A, MW07140C Site Location 2525 West 141st Street Westfield, IN 46074-9676, Hamilton County 39.990217'N./-86.207233 W Tower Description 148 ft Monopole Basic Wind Speed 70 mph (3-Second Gust) Basic Wind Speed w/ Ice 61 mph (3-Second Gust)w//2" ice Code ANSI/TIA-222-G,Addendum 2/2006 IBC Existing and Reserved Equipment Mount El&(ft) Qty. Antenna Mount Type Lines Carrier 148 0 3 RFS ATMAA1412D-1A20 Low Profile Platform (6)1 1/4"Coax T-Mobile 3 RFS APXV18=2065175-C-A20 6 Antel LPD-7905/8 140.0 3 Antel BXA-185090/8CF Low Profile Platform (12)7/8"Coax Verizon Wireless 3 Andrew LNX-8515D5-VTM 6 Andrew 641280-DF 4 Powerwave LGP17502 2 Ericsson KRY 112 71/3 (9)15/8"Coax 6 Powerwave LGP17205 (3)7/8"Coax 4 Ericsson KRY 112 81/2 (2)0.78"8AWG6 130.0 9 Powerwave RA21.7770.00 Platform w/Handrails (1)0.39"Cable AT&T Mobility 3 Powerwave P65-17-XLH-RR (1)2"conduit 4 Powerwave LGP13513 (1)3/8"Coax 1 Ericsson 20.4"x 14.3"BOB 6 Ericsson RRUS 11 122.0 1 Andrew VHLP2-18 Flush (1)1/2"Coax 3 Samsung RRH-P4 3 CSA PCSX065-18-2H (6)11/4"Coax 115.0 6 Decibel DB846G90A-XY Platform w/Handrails (6)7/8"Coax Sprint Nextel 3 Samsung RRH-C2A (3)1.82"Composite 1 Powerwave P90-15-XLPP-RR 2 KMW ET-X-TS-70-15-62-18-iR-RD 95.0 3 EMS FR90-16-XXDP Flush (6)15/8"Coax 85.0 9 EMS RV65-18-02DP T-Arm . (9)15/8"Coax Cleveland Unlimited ATC Tower Services,Inc. -400 Regency Forest Drive-Cary,NC 27518-919.468.0112 Office-919.466.5414 Fax-www.americantower.com Eng. Number 17 2013 April 17, 2013 Page 2 of 2 AMERICAN TOWER' CO n • O n •Tl O N Proposed Equipment Elevation',(ft) Mount RAD Qty. Antenna Mount Type Lines Carrier 1 Raycap ASU9338TYPO1 _ 2 Nokia FXFB' (6)1•1/4"Coax 148:0 150.0 3 Nokia FRIG w/o.Solar Shield Low Profile Platforri T-Mobile (1)1.58"Hybrid 6 Andrew TMBXX-6516=A2M,w/actuator 'Mount elevationisdefined as height above bottom of steel structure to bottom of mount RAD elevation is defined as center of antenna above gradeleveli(AGL). Install proposed coax inside of the pole shaft. The existing and,proposed loads listed in,the tables above are compared.to-the tower's current design capacity or previous structural analysis. Thetower should berre-evaluated as future loads are added or if actual loads are found,differentfrom those listed in the tables. The subject tower and foundation are adequate to support the above stated,leads'inconformance'with specifled.requirements. `ttlU l ni f,/,. No PE10505999 ®• SIATE Or MAW .,,?o, S; ` EN1/47 Apr 182013 11:27 AMoir, an Bs/,KMW ATC Tower Services,Inc -400 Regency Forest Drive=Cary,NC 27518-919.468.0112 Office'-919.466:5414 Fax-www.american[ower.com