HomeMy WebLinkAbout13040194gMATCHING WIDTH CASED EVAPORATOR COIL PIPED PER MANUFACTURERS RECOMMENDATIONS PROVIDE REFRIGERATION LINES PER MANUFACTURES RECOMMENDATIONS 6" FRESH AIR DUCT UP THROUGH ROOF FLASHING WITH MOTORIZED DAMPER. 3/4" PVC DRAIN LINE PROVIDE OPEN SITE DRAIN CONNECTION TO PROTECT COMBUSTION BLOWER INDIRECTION CONNECTION TO FLOOR DRAIN IN SPKLR ROOM LINED RETURN AIR DUCT PROVIDE LINED SHEET METAL RETURN AIR FURNACE BOX EQUIP MANUFACTURER SUPPLIED UNDER FURNACES. SET IN CONCENTRIC ROOF VENT SECONDARY DRAIN PAN WITH MOISTURE CUT OFF SWITCH. RUBBER BOOT DECK FLASHING SPECIFICALLY PVC VENTING PER III' DESIGN FOR METAL ROOF DECK MANUFACTURERS u u RECOMMENDATIONS. VENT UP SEAL WITH POLYURETHANE BASED SEALER, 90% THROUGH ROOF MOUNTED 24" SIKAFLEX -221 OR EQUAL. SILICONE SEALANT UPFLOW CONCENTRIC VENT TERMINAL IS NOT ACCEPTABLE FURNACE E. METAL ROOF WRAPPED SUPPLY AIR DUCT 1X1 STEEL ANGLE BRACE WITH MANUFACTURERS CLAMP STAINLESS SCREW CLAMP TO FURNISHED 18" MIN. SUPPORT VENT. RUNS BETWEEN JOIST, TYPICAL FURNACE INSTALLATION DETAIL SCALE: 1/8" = 1' -0" LOA min FIELD ROUTE PVC VENTING IN STRICT 4 ACCORDANCE WITH EQUIP. MANUF. RECOMMENDATIONS. CONCENTRIC VENT DETAIL SCALE: 1/8" = 1' -0" UPPER FLOOR - HVAC PLAN SCALE: 1/8" = 1' -0" GENERAL NOTES: 1, REFERENCE SHEET M -001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. KEY NOTES: 0 REMOVE EXISTING GAS UNIT HEATER IN ENTIRETY AND EXTEND EXISTING GAS LINE TO NEW GAS FURNACE. PROVIDE AND INSTALL NEW 2 TON AIR COOLED 13 SEER CONDENSING UNIT LIKE CARRIER 24ABB024, 208 1 PHASE. MOUNT UNIT LEVEL ON MANUFACTURERS PLASTIC CONDENSER PAD. ROUTE REFRIGERATION LINES INTO SPRINKER RISER ROOM AND UP TO UNDERSIDE OF ROOF THEN OVER TO A/C COIL, PROVIDE PVC SLEEVE AND SEAL WALL PENETRATION WATER TIGHT. O PROVIDE AND INSTALL NEW UP -FLOW 40 MBH HIGH EFFICIENCY FURNACE WITH 2 TON CASED COIL LIKE CARRIER SC2A040. PROVIDE MANUFACTURE CONCENTRIC ROOF VENT. MOUNT FURNACE IN DRAIN PAN WITH MOISTURE CUT OFF SWITCH. PIPE CONDENSATE TO SPRINKLER RISER ROOM FLOOR DRAIN. KEY NOTES: 4O PROVIDE AND INSTALL 6" MOTORIZED DAMPER AND OUTSIDE AIR DUCT. ROUTE DUCT THROUGH ROOF WITH 6'B-VENT FLUE PIPE, TALL CONE FLASHING, TOPPER AND STORM COLLAR. SEAL WATER TIGHT, INTERLOCK DAMPER TO OPEN WHEN FAN IS RUNNING. O PROVIDE AND INSTALL RESIDENTIAL STYLE LIKE HART AND COOLEY CEILING MOUNTED 14 X 6 SUPPLY AIR REGISTERS. (D PROVIDE AND INSTALL RESIDENTIAL STYLE RETURN AIR STAMPING LIKE HART AND COOLEY SIZED AT 24 X 16. 7O PROVIDE AND INSTALL RESIDENTIAL STYLE RETURN AIR STAMPING LIKE HART AND COOLEY SIZED AT 12 X 12. G�.J )DEfdUM & ASSOCIATES Gooderum & Associates, P.C. 874 Cheltenham Way Avon, Indiana 46123 Phone: (317) 506 -8181 Fax: (317) 745 -5761 FIRST FLOOR - HVAC PLAN SCALE: 1/8" = 1' -0" b 04% 0� _5.a a zu z z i s u- 0 '\^­% bi "w "A .\, 0 �` JI u- Ld 0 Coll 0 ON a E 0 Ow 0 IM uj ?0 0. D Z I D - X � ass X LL a E)W10200395g�� STATE OF a � � U Ell N u 3 ui I � �.a i E: N 12 Y ARCHROTS, 0C. M100