HomeMy WebLinkAbout13040202 Site Plan 1
i
)
i
. ' .ftit, The Schneider Corporation
Schneider Historic Fort Harrison 8901 Otis Avenue Indianapolis;IN 46216-1037 Phone:317.826.7100 Fax: 317.826.7200
Finished Floor Elevation(FEE)Information LOT # 4 xl Plot Plan Legend
Pad.Grad&r 755.8 per plan L I # I I Proposed Grades
Pad Grade+ 1.0' =r Garage FFE(756.8) 000.0 Existing:Grades
Garage FFE.+ 1.9' =Residence FEE(758:7) —000.0 Contour Grade
Residence FFE- 8.9'=Basement FEE(749.8) • * Açiprox. Lateral Location
0 Sanitary Sewer Lines
i\M.F:F:=856.7 \ ---ST---- Storm Sewer Lines
— w — Water Service Lines
Ground Cover Area Calculations
Sob-Surface Drain Lines
Drive = 829 SF+/- 0 Manhole (Sanitary or Storm)
Public Walk.=.'264 SF+./- Private Walk= 75 SW- ® - Beehive Inlet (Storm)
Sod =5,555 SF+/- °E__6° ® - - Endb ection$(Storm)
r0. Fire Hydrant
— ••• — ••• —Flow Line of swale
Optional sod package Assumed North Building Line (BL / 8514
Hydroseeding = 730 SRI- Scald` y _ 30' • - Easement Line
Additional Sod Package = 536 5Y+/-to rear easement
Parcel # (not available at this time)
Sidewalk to be placed
on the property Ilne,
4' from back of curb,
per plan. LOT # 12
NO RESIDENCE
^sm i il'rl.�f ( 75 .5
135.00' `�' }72.15i7". lg i W I
• UDC PER PLAN,I dI ;_ gg• s
N 7-is" A }
W
' 54.5' .: F ' 2„ *I I.29.3S
r4
y ffi
o p �— —
I � � (■� = M
u (� 28:0• (� ,Y;4 E r Ira e�A _ m 24.0'
15' D.U.&S.E. 16.5' _ 0' m1 c p B-B —
13. 00' I
H 4 a
Oil 1 .00 55. I .:'ai•7 ii'KT
I: ;It
LOT,# 10
z NO'RESIDENCE •
m
to
'T SLOE :! .. 51
TYPICAL SWALE SECTION
SIR. 802
NOTE: IN THE RESIDENTIAL DISTRICTS DMITINC ` 1t75590
HEIGHT TO TWENTY-FlW.(25) FEET, A DWEWNG
MAY BE NCREASED IN:HEIGHT TO-'THIRTY-FlYE (35)
FEET PROVIDED THE SIDE ANDREAR YARDS ARE SIGNATURE.: Sat
AN ADDI110NAL FOOT-FOR EACH FOOT
SUCH:STRUCTURE.EXCEEDS-TWENTY-FlVE•(25)-FEET' - - - - -- - -- -- - _. -_
'IN HEIGHT. PER.CARMELl ZONING ORDINANCE 26.1.1.
SIGNAMPEREPRESENTS DaNFIRMA11a1 OF RECEIPT OF:PLOT PLAN BY CUSTOMER
• Garage Finish Floor Elevation-The garage finish floor elevation is 1.6 feet above the curb at the drive per plan.
• Nearby Manhole Casting Elevations-The upstream sanitary manhole has atop of casting elevation of 755.90 and the downstream sanitary manhole has a top of casting
elevation of 755.80 both per plan. The upstream sanitary manhole top of casting elevation shall be no less than one foot(1'-0")below the F.F.E.of the residence.
SHEET 1 OF 2
PLOT PLAN SCALE: 1"=30' - Job # 13.0105657
Prepared For: R.H.OF INDIANA
Subdivision: THE.MEADOWS AT THE LEGACY SECTION 1 ' LOT 11
Recording Info: 2013002735 AND C.O.C.INSTR.#2013008902 I Lot Size: 9,855 SF
County: HAMILTON Township: CLAY , Sec/Twp/Rng:SEC 22-T18N-R4E
Street Address: 14114 BEN KINGSLEY LANE • R/W:33'
Buyer/Owner: DEREK K.AND MAGGIE A.TATTER
Prepared By: EAS DATE: 04-23-13
ff
;t6.1' VCrei■Cn
t The Schneider Corporation
Schneider Historic Fort Harrison 8901 Otis Avenue Indianapolis,IN 46216-1037 Phone:317.826.7100 Faz: 317.826.7200
SHEET 2 of:2(NOTE-this PIot.Plan is not complete unless both sheets are present)
Community Restrictions-Zoning and Setbacks
Side Yard r3,feet Rear Yard=20 feet
Agg.=6 feet RH Zoning F PUD
The client and contractor's attention aredirected to the following notes:
• Purpose-The within.plot plan was prepared.only for the benefit of the parties indicated hereon and for the express purpose of obtaining a residential
construction permitonly.
• Information from others-This plot plan was compiled based in part on documents,such as construction plans or record drawings,prepared by others,and
is not based on a field survey. The'SchneiddriCorPoration cannot and does not warrant the accuracy,completeness,acceptance or sufficiency of such
information.
• Lowest Finished Floor Elevation-Thelowest floor elevation depicted hereon has been determined based on a variety of factors including,but not limited
to,0)the pad grades,elevations and/or contours taken from the construction plans for this subdivision,(ii)the architectural plans for the dwelling,and(iii)
nearby bodies of water and jurisdictional flood protection grades,if any. Unless otherwise stated,no information about water tables,soil conditions,or
soil types has been provided or stated on said plans,If any ground water is encountered during the excavation,or if other known water elevation or soils
conditions are present the buildershould contact The Schneider Corporation to discuss possible courses of action.
▪ It is the undersigned's opinion that if the proposed finished grades-are constructed as shown,the surface drainage on the subject lot will be satisfactory for residential
construction.
• Minimal Tolerances-If the home location shown hereon has minimal tolerance for placement of said home due to its.proximity to setbacklines and/or
easement lines,it is suggested that the builder have the foundation pinned after the footing is poured to help ensure that the improvements do not
encroach upon such lines.
• Existing Conditions-Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be immediately
reported to The Schneider Corporation. Failure to do so will result in the contractor's assumption of all liability,
• Drainage-Contractor to ensure positive drainage away from structure(s).
• Sewer/Water Line Separation-Contractor to maintain a minimum distance of ten feet(10'-0")between water line and sanitary sewer laterals.
• Sanitary Lateral-Contractor shall cut excess off of sanitary lateral as necessary and begin from that point and connect to house.
• Sump Pumps-Contractor to place sump pump(s)as needed.
• Pavement and Manholes/Cleanouts-Contractor shall notplace pavement or concrete;including driveways and sidewalks,on or within one foot(1'-0")
horizontally of any sanitary sewer manhole or clean out casting.
• Sidewalk Placement-It is the responsibility of the contractor to ensure correct sidewalk placement. See sidewalk details and/or as built plans as available
for specific sidewalk details and placement.
• Ramps-Contractor to install street atcess ramps in accordance with municipality requirements.
• Note-Thisdrawing is not intended to be represented as a retracement or original boundary survey,a route survey,or a surveyor location report.
Flood Hazard Statement
The accuracy of any flood hazard data shown on this plot plan is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate mapIFIRM). ALL of the within described land DOES NOT LIE within that Special Flood Hazard Area Zone"X",as said land plots by scale on Community Map Panel
18057C 0235F of the flood insurance rate map(FIRM)for Hamilton County;Indiana,dated February 19,2003.
\\ \\\ \\c)\ ,\ISI„17:„,I,�pp/
50303
_ STATE OF ` 3
SS�r/ufmmmiumoo\o
SHEET 2 OF 2
PLOT PLAN SCALE: 1"=30' Job #.13.0105657
Prepared For: R.H.OF INDIANA
Subdivision: THE MEADOWS AT THE LEGACY SECTION 1 LOT 11
Redording Info: 2013002735 AND C.O.C.INSTR.#2013008902 Lot Size: 9,855 SF
County: HAMILTON Township: CLAY Sec/Twp/Rng:SEC 22-T18N-R4E
Street Address: 14114 BEN KINGSLEY LANE R/W:33'
Buyer/Owner: DEREK K.AND MAGGIE A.TATTER
Prepared By: EAS DATE: 04-23-13