HomeMy WebLinkAbout13040202 Site Plan 1 i ) i . ' .ftit, The Schneider Corporation Schneider Historic Fort Harrison 8901 Otis Avenue Indianapolis;IN 46216-1037 Phone:317.826.7100 Fax: 317.826.7200 Finished Floor Elevation(FEE)Information LOT # 4 xl Plot Plan Legend Pad.Grad&r 755.8 per plan L I # I I Proposed Grades Pad Grade+ 1.0' =r Garage FFE(756.8) 000.0 Existing:Grades Garage FFE.+ 1.9' =Residence FEE(758:7) —000.0 Contour Grade Residence FFE- 8.9'=Basement FEE(749.8) • * Açiprox. Lateral Location 0 Sanitary Sewer Lines i\M.F:F:=856.7 \ ---ST---- Storm Sewer Lines — w — Water Service Lines Ground Cover Area Calculations Sob-Surface Drain Lines Drive = 829 SF+/- 0 Manhole (Sanitary or Storm) Public Walk.=.'264 SF+./- Private Walk= 75 SW- ® - Beehive Inlet (Storm) Sod =5,555 SF+/- °E__6° ® - - Endb ection$(Storm) r0. Fire Hydrant — ••• — ••• —Flow Line of swale Optional sod package Assumed North Building Line (BL / 8514 Hydroseeding = 730 SRI- Scald` y _ 30' • - Easement Line Additional Sod Package = 536 5Y+/-to rear easement Parcel # (not available at this time) Sidewalk to be placed on the property Ilne, 4' from back of curb, per plan. LOT # 12 NO RESIDENCE ^sm i il'rl.�f ( 75 .5 135.00' `�' }72.15i7". lg i W I • UDC PER PLAN,I dI ;_ gg• s N 7-is" A } W ' 54.5' .: F ' 2„ *I I.29.3S r4 y ffi o p �— — I � � (■� = M u (� 28:0• (� ,Y;4 E r Ira e�A _ m 24.0' 15' D.U.&S.E. 16.5' _ 0' m1 c p B-B — 13. 00' I H 4 a Oil 1 .00 55. I .:'ai•7 ii'KT I: ;It LOT,# 10 z NO'RESIDENCE • m to 'T SLOE :! .. 51 TYPICAL SWALE SECTION SIR. 802 NOTE: IN THE RESIDENTIAL DISTRICTS DMITINC ` 1t75590 HEIGHT TO TWENTY-FlW.(25) FEET, A DWEWNG MAY BE NCREASED IN:HEIGHT TO-'THIRTY-FlYE (35) FEET PROVIDED THE SIDE ANDREAR YARDS ARE SIGNATURE.: Sat AN ADDI110NAL FOOT-FOR EACH FOOT SUCH:STRUCTURE.EXCEEDS-TWENTY-FlVE•(25)-FEET' - - - - -- - -- -- - _. -_ 'IN HEIGHT. PER.CARMELl ZONING ORDINANCE 26.1.1. SIGNAMPEREPRESENTS DaNFIRMA11a1 OF RECEIPT OF:PLOT PLAN BY CUSTOMER • Garage Finish Floor Elevation-The garage finish floor elevation is 1.6 feet above the curb at the drive per plan. • Nearby Manhole Casting Elevations-The upstream sanitary manhole has atop of casting elevation of 755.90 and the downstream sanitary manhole has a top of casting elevation of 755.80 both per plan. The upstream sanitary manhole top of casting elevation shall be no less than one foot(1'-0")below the F.F.E.of the residence. SHEET 1 OF 2 PLOT PLAN SCALE: 1"=30' - Job # 13.0105657 Prepared For: R.H.OF INDIANA Subdivision: THE.MEADOWS AT THE LEGACY SECTION 1 ' LOT 11 Recording Info: 2013002735 AND C.O.C.INSTR.#2013008902 I Lot Size: 9,855 SF County: HAMILTON Township: CLAY , Sec/Twp/Rng:SEC 22-T18N-R4E Street Address: 14114 BEN KINGSLEY LANE • R/W:33' Buyer/Owner: DEREK K.AND MAGGIE A.TATTER Prepared By: EAS DATE: 04-23-13 ff ;t6.1' VCrei■Cn t The Schneider Corporation Schneider Historic Fort Harrison 8901 Otis Avenue Indianapolis,IN 46216-1037 Phone:317.826.7100 Faz: 317.826.7200 SHEET 2 of:2(NOTE-this PIot.Plan is not complete unless both sheets are present) Community Restrictions-Zoning and Setbacks Side Yard r3,feet Rear Yard=20 feet Agg.=6 feet RH Zoning F PUD The client and contractor's attention aredirected to the following notes: • Purpose-The within.plot plan was prepared.only for the benefit of the parties indicated hereon and for the express purpose of obtaining a residential construction permitonly. • Information from others-This plot plan was compiled based in part on documents,such as construction plans or record drawings,prepared by others,and is not based on a field survey. The'SchneiddriCorPoration cannot and does not warrant the accuracy,completeness,acceptance or sufficiency of such information. • Lowest Finished Floor Elevation-Thelowest floor elevation depicted hereon has been determined based on a variety of factors including,but not limited to,0)the pad grades,elevations and/or contours taken from the construction plans for this subdivision,(ii)the architectural plans for the dwelling,and(iii) nearby bodies of water and jurisdictional flood protection grades,if any. Unless otherwise stated,no information about water tables,soil conditions,or soil types has been provided or stated on said plans,If any ground water is encountered during the excavation,or if other known water elevation or soils conditions are present the buildershould contact The Schneider Corporation to discuss possible courses of action. ▪ It is the undersigned's opinion that if the proposed finished grades-are constructed as shown,the surface drainage on the subject lot will be satisfactory for residential construction. • Minimal Tolerances-If the home location shown hereon has minimal tolerance for placement of said home due to its.proximity to setbacklines and/or easement lines,it is suggested that the builder have the foundation pinned after the footing is poured to help ensure that the improvements do not encroach upon such lines. • Existing Conditions-Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be immediately reported to The Schneider Corporation. Failure to do so will result in the contractor's assumption of all liability, • Drainage-Contractor to ensure positive drainage away from structure(s). • Sewer/Water Line Separation-Contractor to maintain a minimum distance of ten feet(10'-0")between water line and sanitary sewer laterals. • Sanitary Lateral-Contractor shall cut excess off of sanitary lateral as necessary and begin from that point and connect to house. • Sump Pumps-Contractor to place sump pump(s)as needed. • Pavement and Manholes/Cleanouts-Contractor shall notplace pavement or concrete;including driveways and sidewalks,on or within one foot(1'-0") horizontally of any sanitary sewer manhole or clean out casting. • Sidewalk Placement-It is the responsibility of the contractor to ensure correct sidewalk placement. See sidewalk details and/or as built plans as available for specific sidewalk details and placement. • Ramps-Contractor to install street atcess ramps in accordance with municipality requirements. • Note-Thisdrawing is not intended to be represented as a retracement or original boundary survey,a route survey,or a surveyor location report. Flood Hazard Statement The accuracy of any flood hazard data shown on this plot plan is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate mapIFIRM). ALL of the within described land DOES NOT LIE within that Special Flood Hazard Area Zone"X",as said land plots by scale on Community Map Panel 18057C 0235F of the flood insurance rate map(FIRM)for Hamilton County;Indiana,dated February 19,2003. \\ \\\ \\c)\ ,\ISI„17:„,I,�pp/ 50303 _ STATE OF ` 3 SS�r/ufmmmiumoo\o SHEET 2 OF 2 PLOT PLAN SCALE: 1"=30' Job #.13.0105657 Prepared For: R.H.OF INDIANA Subdivision: THE MEADOWS AT THE LEGACY SECTION 1 LOT 11 Redording Info: 2013002735 AND C.O.C.INSTR.#2013008902 Lot Size: 9,855 SF County: HAMILTON Township: CLAY Sec/Twp/Rng:SEC 22-T18N-R4E Street Address: 14114 BEN KINGSLEY LANE R/W:33' Buyer/Owner: DEREK K.AND MAGGIE A.TATTER Prepared By: EAS DATE: 04-23-13