CODE SUMMARY
1 I SCOPE OF WORK I OFFICE SPACE /MEDICAL EXAM REMODEL FROM EXISTING
OFFICE SPACE
2 OCCUPANCY CLASSIFICATION B{USINESS)
3 CHANGE OF OCCUPANCY CLASSr NO
4 TOTAL BUILDING AREA 28,734 SF/FLOOR
5 TOTAL PROJECT AREA 1,079 SF
6 OCCUPANCY CALCULATIONS SPACE TYPE
GEN. OFFICE
7 NUMBER OF REQUIRED EXITS
8 SPRINKLER SYSTEM (YES/NO)
9 TOTAL AREA OF ACCESSORY USES
10 TOTAL AREA ON THE FLOOR
1 1 ACCESSORY AREA EXCEEDS 10%
12 FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED}
�t I
X � 2 STORIES �_ � 28,734 SF
AREA I SF PER OCCUPANT � OCCUP LOAD
1,079 SF 100 1 1
TOTAL OCCUPANTS IN PROJECT AREA
1
YES - EXISTING TO REMAIN
0 SF
24,529 SF
NO
N/A
m
LEGEND
Ep EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT
Q FIRE EXTINGUISHER
� EXIT SIGNAGE
� EMERGENCY LIGHTING
NIEI NIGHT LIGHT/EMERGENCY LIGHTING
(NIGHT LIGHTS ARE HOOKED UP TO
BUILDINGS EMERGENCY GENERATOR)
,
LIFE SAFETY NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATfERY PACKS OR LIGHTS CONNECTED
TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE
CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR
REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER
REQUIRED ALARM &• DETECTION SYSTEMS AS NECESSARY TO MEEf ALL
APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL
FIRE CODE, NFPA).
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE
DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10.
COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND
HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO
A VISIBLE EXTINGUISHER.
0
GENERAL NOTES
L1. REFER TO SHEEf A111 FOR WALL TYPE AND CONSTRUCTION DETAILS
L2. EXISTING COMMON ENTRYWAY TO REMAIN. EXISTING EXIT SIGNS, FIRE
PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN.
FIRST FLOOR
LIFE SAFETY PLAN "
0 4' 8' 16'
1
�
��
� � QO Q
��'f�l�
i � � �
� •
a � �
N,���� N �
� �� �
�
� � � �
N .��- , ,
� ..
I� .� Q 4-
THIS DRAWING, AND THE IDEAS
DESIGNS AND CONCEPTS CONTAII
HEREIN, ARE THE EXCLUSIVE
iNTELLECTUAL PROPERTY OF SCHC
DESIGN, INC., AND ARE NOT TO E
USED OR REPRODUCED IN WHOLE,
IN PART, WITHOUTTHE WRITfEN
CONSENT OF SCHOiT DESIGN.
�
O
O
J
� �
Z��
_-��
F- -J �- �C
J .�
� �
WJ=
WOLL
= V<
W �
� y Q
� � Q
= C.,
V
N
O
�'
�
SSUE
DATE � DESCRIPTION
03.22.13 REVIEW SET
IONS
DATE ( DB IDESCRIPi
`� H
\�
IV 0.
AR10700017
�` STATE OF
i���S'r � _ .�\
np�" _
PRQJECT NUMBER
2013.069
PROJ. MGR DRAWN I
MAK MAK
1 ST FLOOR
LIFE SAFETY