HomeMy WebLinkAbout13050079.2__- _
DEMOLITION LEC EN D
EXISTING TO BE REMOVED ' EXISTING TO REMAIN
— — — WALL WALL
_ �
/ DOOR AND FRAME DOOR AND FRAME
_/
�- � WINDOW 1 SIDELIGHT x WINDOW / SIDELIGHT
� — — � CEIIING GRID AND
� _ _ � TILES, 2'x4'
I—I— I CEILING GRID AND
� _I_ � TILES, 2'x2'
� � SUPPLY AIR DIFFUSERS
��o
C= �I LIGHT FIXTURE,
L = Jl FLUORESCENT, 2'x4'
r -11 LIGHT FIXTURE,
�L � FLUORESCENT, 2'x2'
� LIGHT FIXTURE, CAN
��� LIGHT FIXTURE, TRACK '
� LIGHT FIXTURE, SCONCE
LIGHT FIXTURE,
� PENDANT
� LIGHT SWITCH
g` EXIT LIGHT
t =�
�B�<a��J1 ELECTRIC OUTLET(S)
DATA OR
�'� COMMUNICATION
OUTLET
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
DEMOLITION PLAN NOTES
D01 REMOVE EXISTING SIDELIGHT. VERIFY IF BUILDING OWNER WANTS
TO SALVAGE FOR ATTIC STOCK.
D02 REMOVE EXISTING WINDOW. VERIFY IF BUILDING OWNER WANTS
TO SALVAGE FOR ATTIC STOCK.
D03 REMOVE EXISTING SPORTS FLOORING TO LIMITS OF NEW
CONSTRUCTION.
D04 REMOVE EXISTING CEILING GRID AND LIGHT FIXTURES. SALVAGE
LIGHT FIXTURES FOR REUSE. RELAMP �IGHT FIXTURES AS REQUIRED.
� AREA NOT IN CONTRACT
❑ AREA OF WORK
D EMO LITI O N P LA N
0 4' 8' 16'
� � ,
� ��
� ��- ���
. . �-, �,- ���,��.����. � e� ��
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE �2 UNLESS OTHERWISE NOTED.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PR4JECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
W� STANDARD WALL
35/$ " METAI STUDS AT 16" O.C.; f�
ONE LAYER OF 5/g' TYPE "X" GYPSUM BOARD - -
EACH SIDE;
EXTEND WALL TO DECK ABOVE.
W2 STANDARD WALL WITH INSULATION >` < - >�=-• �-- °�> -° �
�~"�.'
35/g " METAL STUDS AT 16" O.C.; ,� r' `��, ,� ., '
ONE LAYER OF 5/g' TYPE "X" GYPSUM BOARD �-' �/
EACH SIDE;
EXTEND WALL TO DECK ABOVE;
FIBERGLASS SOUND BATf INSULATION INSIDE
WALL.
W3 STANDARD DEMISING WALL TO DECK
35�g" 16 GA. METAL STUDS AT 12" O.C.;
ONE LAYER OF $/g" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO 48" (approx.} ABOVE
CEILING HEIGHT;
FIBERGLASS SOUND BATf INSULATION INSIDE
WALL.
NOTE: CONTRACTOR TO CONFIRM
CONSTRUCTION METHOD AND METAL STUD
GAUGE WILL BE SUCH AS TO HOLD THE NEW
FLOOR ABOVE.
W4 STANDARD PLUMBING CHASE WALL
35/g" METAL STUDS AT 16" O.C.;
ONE LAYER OF 5/g" TYPE "X" MOISTURE
RESISTANT GYPSUM BOARD EACH SIDE;
EXTEND WALL TO DECK ABOVE;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" SOUND BATf INSULATION
EACH SIDE OF WALL ABOVE CEILING.
W5 STANDARD MECHANICAL CHASE WALL
3$�g" METAL STUDS AT 16" O.C.;
ONE LAYER OF 5/g" TYPE "X" GYPSUM BOARD
ON ONE SIDE;
EXTEND WALL TO DECK ABOVE;
FIBERGLASS SOUND BATf INSULATION INSIDE
WALL AND 2'-0" SOUND BATf INSULATION
EACH SIDE OF WALL ABOVE CEILING.
. � i :..,. .�,,,�,�;,%:`�
`�,. �� J `� / � �%
.:.\,,:; � � .��. ..�
.
--�' `
s
ARCH ITECTU RAL LEGEN D
NEW CONSTRUCTION EXISTING TO REMAIN
WALL WALL
W?
�a WINDOW / SIDELIGHT �---¢ WINDOW / SIDELIGHT
�DOOR AND FRAME
(SEE DOOR SCHEDULE) DOOR AND FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
GENERAL NOTES
1. S E E E L E C T R I C A L P L A N O N S H E E T E- 1 F O R I N T E N D E D F U R N I T U R E
LAYOUT.
2. PROVIDE INDIVIDUAL CEILING GRIDS PER ROOM AND OR
AREA. CONFIRM FINAL CEILING HEIGHT WITH GENERAL
CONTRACTOR. REFER TO SHEEf E-1 FOR LIGHT LOCATIONS AND
TYPES. PROVIDE GYPSUM BOARD CEILING AT 8'-0" IN DRUG TEST
ROOM.
ARCHITECTURAL PLAN NOTES
OA01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 3'x6'x4', PAINTED WITH FIRE
A02 REfARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
ONEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
A03 CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10.
OPROVIDE 15' WIDE ADJUSTABLE MELAMINE SHELVING ON HEAVY
A04 DUTY BRACKEfS FOR MEDS CLOSEf. PROVIDE MINIMUM 5 SHELVES.
OPROVIDE 3' WIDE X 4' TALL SLIDING WINDOW WITH PI_ASTIC
A05 �MINATE TRANSACTION COUNTER. RADIUS CORNERS OF
TRANSACTION COUNTER. INSTALL WINDOW AT 42" A.F.F. TO
COUNTER.
PROVIDE 30" DEEP BY 30" HIGH PLASTIC LAMINATE WORK SURFACE
Ad6 vy�TH PLASTIC LAMINATE SUPPORTS AS REQUIRED. PROVIDE THREE
PLASTIC GROMMETS IN WORK SURFACE.
A07 PROVIDE FURRED OUT WALL SYSTEM AS NECESSARY AT EXISTING
EXTERIOR WALL AS REQUIRED.
A08 PROVIDE ACCESS PANEL IN WALL FOR ACCESS TO PLUMBING
PUMP.
CONTRACTOR TO PROVIDE FINISHED "ROOF' STRUCTURE AT
A09 PORTION OF PLAN THAT IS BEYOND THE LIMITS OF THE MEZZANINE.
P01 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
P02 PROVIDE TANKLESS TOILEf.
P03 PROVIDE ADA ACCESSIBLE RESTROOM. PROVIDE WALL
MOUNTED ADA ACCESSIBLE SINK, FAUCET, GRAB BARS
(INCLUDING VERTICALj, MIRROR, SOAP DISPENSER AND PAPER
TOWEL DISPENSER. ALL ACCESSORIES TO MEEf ALL STATE AND
LOCAL CODES. VERIFY MOUNTING HEIGHTS PRIOR TO INSTALLING.
� AREA NOT IN CONTRACT
� AREA OF WORK
ARCH ITECTU RAL PLAN "
0 4' 8' 16'
�
��
> � � O O
���� U
� � � � �
� ' ••
���� �
� � � � �
� (� }
N ' O
_ � • �
3 �� � �
� a � � .
N � ��
I� � Q 4-
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTf
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUTTHE WRITfEN
CONSENT OF SCHOTf DESIGN.
�
O
O
� �
Z �- N
� � � �
�J��
J .�
� `
W � '
WpJ
= Vw
W <
� y �
_�a�
=U
V
N
0
�
r
iUE
DATE � DESCRIPTION
REVIEW SET
IONS
DATE
DB
��� " eoy�
� �
N o.
AR10700017
STATE OF �
S'r � A ,�a�
nn.�"
PROJECT NUMBER
2013.Ob9
PROJ. MGR DRAWN BY
MAK MAK
1 ST FLOOR
DEMOLITION PLAN�
ARCHITECTURAL
FLOOR PLAN
, � � �. .
�� I �� k� � � .
. I I ..