HomeMy WebLinkAbout13050079.2__- _ DEMOLITION LEC EN D EXISTING TO BE REMOVED ' EXISTING TO REMAIN — — — WALL WALL _ � / DOOR AND FRAME DOOR AND FRAME _/ �- � WINDOW 1 SIDELIGHT x WINDOW / SIDELIGHT � — — � CEIIING GRID AND � _ _ � TILES, 2'x4' I—I— I CEILING GRID AND � _I_ � TILES, 2'x2' � � SUPPLY AIR DIFFUSERS ��o C= �I LIGHT FIXTURE, L = Jl FLUORESCENT, 2'x4' r -11 LIGHT FIXTURE, �L � FLUORESCENT, 2'x2' � LIGHT FIXTURE, CAN ��� LIGHT FIXTURE, TRACK ' � LIGHT FIXTURE, SCONCE LIGHT FIXTURE, � PENDANT � LIGHT SWITCH g` EXIT LIGHT t =� �B�<a��J1 ELECTRIC OUTLET(S) DATA OR �'� COMMUNICATION OUTLET NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. DEMOLITION PLAN NOTES D01 REMOVE EXISTING SIDELIGHT. VERIFY IF BUILDING OWNER WANTS TO SALVAGE FOR ATTIC STOCK. D02 REMOVE EXISTING WINDOW. VERIFY IF BUILDING OWNER WANTS TO SALVAGE FOR ATTIC STOCK. D03 REMOVE EXISTING SPORTS FLOORING TO LIMITS OF NEW CONSTRUCTION. D04 REMOVE EXISTING CEILING GRID AND LIGHT FIXTURES. SALVAGE LIGHT FIXTURES FOR REUSE. RELAMP �IGHT FIXTURES AS REQUIRED. � AREA NOT IN CONTRACT ❑ AREA OF WORK D EMO LITI O N P LA N 0 4' 8' 16' � � , � �� � ��- ��� . . �-, �,- ���,��.����. � e� �� WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE �2 UNLESS OTHERWISE NOTED. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PR4JECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. W� STANDARD WALL 35/$ " METAI STUDS AT 16" O.C.; f� ONE LAYER OF 5/g' TYPE "X" GYPSUM BOARD - - EACH SIDE; EXTEND WALL TO DECK ABOVE. W2 STANDARD WALL WITH INSULATION >` < - >�=-• �-- °�> -° � �~"�.' 35/g " METAL STUDS AT 16" O.C.; ,� r' `��, ,� ., ' ONE LAYER OF 5/g' TYPE "X" GYPSUM BOARD �-' �/ EACH SIDE; EXTEND WALL TO DECK ABOVE; FIBERGLASS SOUND BATf INSULATION INSIDE WALL. W3 STANDARD DEMISING WALL TO DECK 35�g" 16 GA. METAL STUDS AT 12" O.C.; ONE LAYER OF $/g" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 48" (approx.} ABOVE CEILING HEIGHT; FIBERGLASS SOUND BATf INSULATION INSIDE WALL. NOTE: CONTRACTOR TO CONFIRM CONSTRUCTION METHOD AND METAL STUD GAUGE WILL BE SUCH AS TO HOLD THE NEW FLOOR ABOVE. W4 STANDARD PLUMBING CHASE WALL 35/g" METAL STUDS AT 16" O.C.; ONE LAYER OF 5/g" TYPE "X" MOISTURE RESISTANT GYPSUM BOARD EACH SIDE; EXTEND WALL TO DECK ABOVE; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" SOUND BATf INSULATION EACH SIDE OF WALL ABOVE CEILING. W5 STANDARD MECHANICAL CHASE WALL 3$�g" METAL STUDS AT 16" O.C.; ONE LAYER OF 5/g" TYPE "X" GYPSUM BOARD ON ONE SIDE; EXTEND WALL TO DECK ABOVE; FIBERGLASS SOUND BATf INSULATION INSIDE WALL AND 2'-0" SOUND BATf INSULATION EACH SIDE OF WALL ABOVE CEILING. . � i :..,. .�,,,�,�;,%:`� `�,. �� J `� / � �% .:.\,,:; � � .��. ..� . --�' ` s ARCH ITECTU RAL LEGEN D NEW CONSTRUCTION EXISTING TO REMAIN WALL WALL W? �a WINDOW / SIDELIGHT �---¢ WINDOW / SIDELIGHT �DOOR AND FRAME (SEE DOOR SCHEDULE) DOOR AND FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. GENERAL NOTES 1. S E E E L E C T R I C A L P L A N O N S H E E T E- 1 F O R I N T E N D E D F U R N I T U R E LAYOUT. 2. PROVIDE INDIVIDUAL CEILING GRIDS PER ROOM AND OR AREA. CONFIRM FINAL CEILING HEIGHT WITH GENERAL CONTRACTOR. REFER TO SHEEf E-1 FOR LIGHT LOCATIONS AND TYPES. PROVIDE GYPSUM BOARD CEILING AT 8'-0" IN DRUG TEST ROOM. ARCHITECTURAL PLAN NOTES OA01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 3'x6'x4', PAINTED WITH FIRE A02 REfARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. ONEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY A03 CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. OPROVIDE 15' WIDE ADJUSTABLE MELAMINE SHELVING ON HEAVY A04 DUTY BRACKEfS FOR MEDS CLOSEf. PROVIDE MINIMUM 5 SHELVES. OPROVIDE 3' WIDE X 4' TALL SLIDING WINDOW WITH PI_ASTIC A05 �MINATE TRANSACTION COUNTER. RADIUS CORNERS OF TRANSACTION COUNTER. INSTALL WINDOW AT 42" A.F.F. TO COUNTER. PROVIDE 30" DEEP BY 30" HIGH PLASTIC LAMINATE WORK SURFACE Ad6 vy�TH PLASTIC LAMINATE SUPPORTS AS REQUIRED. PROVIDE THREE PLASTIC GROMMETS IN WORK SURFACE. A07 PROVIDE FURRED OUT WALL SYSTEM AS NECESSARY AT EXISTING EXTERIOR WALL AS REQUIRED. A08 PROVIDE ACCESS PANEL IN WALL FOR ACCESS TO PLUMBING PUMP. CONTRACTOR TO PROVIDE FINISHED "ROOF' STRUCTURE AT A09 PORTION OF PLAN THAT IS BEYOND THE LIMITS OF THE MEZZANINE. P01 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. P02 PROVIDE TANKLESS TOILEf. P03 PROVIDE ADA ACCESSIBLE RESTROOM. PROVIDE WALL MOUNTED ADA ACCESSIBLE SINK, FAUCET, GRAB BARS (INCLUDING VERTICALj, MIRROR, SOAP DISPENSER AND PAPER TOWEL DISPENSER. ALL ACCESSORIES TO MEEf ALL STATE AND LOCAL CODES. VERIFY MOUNTING HEIGHTS PRIOR TO INSTALLING. � AREA NOT IN CONTRACT � AREA OF WORK ARCH ITECTU RAL PLAN " 0 4' 8' 16' � �� > � � O O ���� U � � � � � � ' •• ���� � � � � � � � (� } N ' O _ � • � 3 �� � � � a � � . N � �� I� � Q 4- THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTf DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUTTHE WRITfEN CONSENT OF SCHOTf DESIGN. � O O � � Z �- N � � � � �J�� J .� � ` W � ' WpJ = Vw W < � y � _�a� =U V N 0 � r iUE DATE � DESCRIPTION REVIEW SET IONS DATE DB ��� " eoy� � � N o. AR10700017 STATE OF � S'r � A ,�a� nn.�" PROJECT NUMBER 2013.Ob9 PROJ. MGR DRAWN BY MAK MAK 1 ST FLOOR DEMOLITION PLAN� ARCHITECTURAL FLOOR PLAN , � � �. . �� I �� k� � � . . I I ..