Loading...
HomeMy WebLinkAbout13003 ORTHO INDY PT 04-18-13.pdf� � � i � � i \ � � � � � � m m � � m � � � � �v � � � � x 0 0 r�nc-T o" c- n n i c-rinirn / (( � 11 \ 1 \ � � � \ \ � � � \ / \ ♦ � / / / � , � I T� �T I � I T� � ����T I �� ����: � i' � I " = 30' `� � �� �� ���� I ��, �I�. �� ���� ��� ���, �ER MAI N � � � \� A. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO HIS PHASE OF THE WORK. IT SHALL ALSO BE THE CONTRACTORS RESPONSIBILITYTO CONTACT THE OWNER OF THE VARIOUS UTILITIES BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNERS OR ENGINEERS OF ANY CHANGES, ERRORS OR OMISSIONS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. B. NO ROOF DRAINS, FOOTING DRAINS AND/OR SURFACE WATER DRAINS MAY BE CONNECTED TO THE SANITARY SEWER SYSTEM, INCLUDING TEMPORARY CONNECTIONS DURING CONSTRUCTION. C. NO TRAFFIC WILL BE ALLOWED ON PREPARED SUBGRADE PRIOR TO PAVING. D. ALL PIPE OR DRAINAGE STRUCTURES IN TRENCHES UNDER PAVED SURFACE SHALL BE BACKFILLED WITH GRANULAR MATERIAL AND COMPACTED BY APPROVED METHODS. E. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL STATE, CITY, AND COUNTY PERMITS AND PAYING ALL COST THEREOF. F. EXISTING UTILITIES ARE SHOWN APPROXIMATE ONLY. CONTRACTOR SHALL VERIFY LOCATION, SIZE, MATERIAL AND DEPTH WITH RESPECTIVE OWNERS AND SHALL PROTECT THE UTILITIES AT ALL TIMES. G. THE CONTRACTOR SHALL INSTALL AND/OR CAUSE TO BE INSTALLED ALL EXTERIOR UTILITIES AND SHALL PAY ALL COSTS AND FEES NOT BORNE BY THE LOCAL UTILITIES. ALL AS NECESSARY TO PROVIDE COMPLETE NEW UTILITY SERVICES AS PER THE REQUIREMENTS AND STANDARDS OF THE RESPECTIVE UTILITY COMPANIES. H. WHERE WATER LINES AND SANITARY SEWERS CROSS AND WATER LINES CANNOT BE PLACED ABOVE THE SEWER WITH A MINIMUM OF 18 INCHES VERTICAL CLEARANCE, THE SEWER MUST BE CONSTRUCTED OF WATER WORKS GRADE DUCTILE IRON PIPE WITH MECHANICAL JOINTS WITHIN 10 FEET OF THE WATER LINE. I. SEE ARCHITECTURAL FOUNDATION PLANS FOR ACTUAL BUILDING DIMENSIONS. J. SANITARY SEWER PIPING SHALL BE PVC PIPE, ASTM D3034. JOINTS SHALL BE EQUAL TO ASTM C-425, TYPE III FOR COMPRESSION TYPE JOINTS AND INSTALLED WITH AN INFILTRATION LIMIT OF 0.158 GAL./IN. DIA./HOUR/100 FT. PROVIDE FOR CERTIFIED SATISFACTORY "AIR TEST" AND "MANDRIL TEST" IN ACCORDANCE WITH THE REQUIREMENTS OF THE UTILITY C0. K. WATER MAIN FOR 3" AND LARGER SIZES SHALL BE �� CENTRIFUGALLY CAST DUCTILE IRON PIPE IN ACCORDANCE � WITH ASA A21.4. TRENCH CONDITION TO BE LAYING CONDITION "2" AND PIPE COVER OF 54 IN. EXCEPT AS NOTED. PIPE TO BE THICKNESS CLASS 50. JOINT TO BE SINGLE RUBBER GASKET PUSH-ON TYPE IN ACCORDANCE WITH ANSI SPEC A 21.11. PROVIDE FOR DISINFECTION (CHLORINATION) OF THE WATER LINE AND CERTIFIED SATISFACTORY BACTERIOLOGICAL FIRST DAY AND SECOND DAY TEST RESULTS IN ACCORDANCE WITH THE REQUIREMENTS OF THE UTILITY C0. L. GATE VALVES SHALL BE CAST IRON BODY, DOUBLE DISC, BRONZE MOUNTED, NON-RISING STEM TYPE IN ACCORDANCE WITH AWWA STANDARD C-500. TO BE FOR 175 PSI WORKING PRESSURE, DIRECT BURIAL SERVICE, WITH MECHANICAL, BELL-END JOINTS, COUNTERCLOCKWISE OPENINGS, 0-RING PACKING AND 2 IN. TEE WRENCH NUT. VALVES TO HAVE 3 PIECE, ROUND, TYPE CAST IRON BUFFALO ROAD BOX WITH 5-1/4 IN. SHAFT, WITH "WATER" CAST IN THE LID. BOXES TO BE FOR NORMAL 4 FT.-6 IN. BUT SHALL BE AS REQUIRED TO SUIT EACH PARTICULAR SETTING DEPTH. VALES SHALL BE CLOW, KENNEDY, MUELLER OR APPROVED EQUAL FOR INDIANAPOLIS WATER COMPANY (IWC) PATTERN. M. STREEf REPAIR SHALL BE IN ACCORDANCE WITH THE STANDARDS OF THE LOCAL AUTHORITY. N. CONTRACTOR SHALL CONSULT WITH THE LOCAL TELEPHONE UTILITY COMPANY AND SHALL PROVIDE CONDUITS AND WORK AS REQUIRED TO PROVIDE SERVICE TO EACH BUILDING. 0. CONTRACTOR SHALL CONSULT WITH THE LOCAL ELECTRIC UTILITY COMPANY AND SHALL PROVIDE CONDUIT, CONDUCTORS AND WORK AS NECESSARY TO PROVIDE ELECTRICAL SERVICE TO EACH BUILDING. � � �, — � CUT-IN NEW SANITARY BLDG. LATERAL CONNECTION INTO � EXISTING MANHOLE WITH CORE DRILLED HOLE AND MANUFACTURED LEAK TIGHT SLEEVE FITTING ACCEPTABLE TO THE UTILITY C0. TAP INTO THE EXISTING WATER MAIN WITH AN 12"X4" 2 TAPPING SLEEVE AND VALVE IN ACCORDANCE WITH THE REQUIREMENTS OF THE UTILITY C0. REDUCE DOWN FROM A 4" TO A 2" WATER LINE AND 3 PROVIDE FOR INSTALLATION OF DUAL 1" METER PITS WITH ONE (1) 1" METER AND FITTINGS FOR AN ADDITIONAL 1" METER IN THE SECOND PIT IN THE FUTURE. ALL IN ACCORDANCE WITH THE REQUIREMENTS OF THE UTILITY COMPANY. � , � — �--� — EXISTING SANITARY SEWER PROPOSED SANITARY SEWER PROPOSED UNDERGROUND ELECTRICAL SERVICE PROPOSED UNDERGROUND TELEPHONE SERVICE PROPOSED WATER LINE I , :11111I.y � IIlI:F.' i.' l � :,�1 [I ] � PROPOSED CLEANOUT --�-----�`---- // �i UGE UGT W G � // i� CO ARCHITEGTS, LLG ARCHITECTS, PLANNERS 305 East New York Street Indianapolis, Indiana 46204 (317) 656-3500 Fax (317) 656-3501 � � � � � �� � � ' 1 W � - � oa Z J W � � � LL � � � Z Z a� ° J � U m . W � ��W CA � � � � O Q � oo U m o � O ,.c� W m O J = <t � Q O CERIIFIED BY� '� m o m m � z = W � Z m � p = � m 0 U � �,�GK A • eao.0000e s� �Q� ;,��GJSTE�.e��O Q 4o es � e e e e • e 3135 = • e o� ��; ;o s-r �v ��t��° � „ D I �4 J.�� / NORTH= 0 � U � 0 � a 0 � SHEET N0. � 51T� PL�N � � � � � � � � N m � � � � � � � 0 � 0 0 � � � � � �� m � �� m � � � � � � � � � X O 0 • � , �� , ,�� , , \ ��� �� EXISTING 10'-0" HIGH CEILING �����ITI�� ��I�I�:� ���� ��8�� _ I �_O�� N OTE: ALL ACOUSTICAL CEILINGS ARE 9'-0" HIGH UNLESS OTHERWISE NOTED. ����I�� �OT�� 1. CLEAN ALL WINDOW BLINDS 2. CLEAN LENSES OF ALL LIGHT FIXTURES. 3. RE-LAMP ALL LIGHT FIXTURES. ��0�� �O�U���T� THE DOCUMENTS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF DESIGN CONCEPT, DIMENSIONS, AND MAJOR ARCHITECTURAL ELEMENTS. THESE DOCUMENTS DO NOT NECESSARILY DESCRIBE OR INDICATE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, EACH TRADE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLEfION OF THIS WORK. ������� �OT�� 1. THE DRAWINGS AND SPECS. ARE AN INSTRUMENT OF SERVICE AND ARE THE SOLE PROPERTY OF THE ARCHITECT. ANY RE-USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. 2. THE DRAWINGS AND SPECS. ARE THE SOLE PROPERTY OF THE OWNER. ANY RE-USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE OWNER. 3. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS, AND ORDINANCES. 4. VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING. 5. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. 6. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED. 7. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE DAILY. : � THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES. ALL DIMENSIONS ARE FROM FACE OF DRYWALL TO FACE OF DRYWALL. 10. ALL INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 11. ADA - TENANT BUILD OUT DESIGN HAS BEEN BASED UPON OUR TRAINING AND UNDERSTANDING OF THE REGULATIONS AND GUIDELINES ISSUED AS COMPONENT PARTS TO TITLE III OF THE AMERICANS WITH DISABILITIES ACT, PUBLIC LAW 101-336. DESIGN RESOLUTION DOES NOT ATTEMPT TO ADDRESS POTENTIAL CONCERNS ASSOCIATES WITH OTHER TITLES OF THE ACT THAT IMPLICATE POLICY, PROCEDURES, AND TELECOMMUNICATIONS ISSUES. 12. ALL EXIT DOOR LOCKS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 13. DOOR CLOSERS AT INTERIOR DOORS SHALL BE ADJUSTED SO THAT THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL NOT EXCEED 5 LBS. 14. INTERIOR DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 IN. FROM THE LATCH TO THE LEADING EDGE OF THE DOOR. 15. ALL MECHANICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 16. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 17. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 18. VERIFY WITH 'fiENANT" ALL BUILDING STANDARD MATERIALS & SYSTEMS. ���0� I T I O�l �OT�� 0 1. REMOVE STUD WALL IN THEIR ENTIRETY. 2. REMOVE DOOR, FRAME & HARDWARE IN THEIR ENTIRETY. 3. REMOVE COUNTERTOP & CABINETRY IN THEIR ENTIRETY. 4. REMOVE SINKS, ACCESSORIES & RELOCATE TO NEW PLAN. 5. REMOVE FLOOR FINISH IN THEIR ENTIRETY. 6. REMOVE STUD WALL AS REQ'D. FOR NEW OPENING. 7. REMOVE URINAL IN ITS ENTIRETY. PATCH OPENINGS AS REQ'D. TO MATCH ADJACENT SURFACES. 8. REMOVE 8c REPLACE EXISTING CONCRETE SLAB TO ACCOMODATE NEW BACK-FLOW PREVENTION DEVICE. 9. REMOVE CEILING TILE & GRID AS REQ'D. FOR NEW CONSTRUCTION. 10. REMOVE 2'X2' FLOURESCENT LIGHT FIXTURES RELOCATE TO NEW PLAN 11. REMOVE SUPPLY AIR GRILLE RELOCATE TO NEW PLAN 12. REMOVE EXHAUST FAN. RELOCATE TO NEW PLAN 13. REMOVE EXISTING BASE. 14. REMOVE TOILET, GRAB BARS 8c RELOCATE TO NEW PLAN. ��� ��� I � FIRST FLOOR � ,illllllll�i�"'' ""'�i�lllllllli, �illl Ili�� noTUn ir,inv nT ARCHITECTS, LLC ARCHITECTS, PLANNERS 305 East New York Street Indianapolis, Indiana 46204 (317) 656-3500 Fax (317) 656-3501 W � - � � � � Q � z � � � W � 0 � � � � � � �Z � z Q ^ � � �� U � � .� � ° �� W �� � � � � o pQ � � oo U m � �n o � � m o m �� in m �n W� O z� W� Z m o ri � �\ o o � ° CERIIFIED BY GK A. �Q��` OOipO0000000 �i� ,��G,ISTE�,o��0 Q� :2 e . • ° 3135 � • e . �a o� t��,%,vo s-r � v .n.�e D I _e _ .��� NORTH� � � % /�% � ����iii� 0 � � � w 0 a 0 � SHEET N0. D�MOL I TI ON �L�NS � m � � � m � � � � O � O 0 � � � � � ,� rr> � �� m � � � � � � � � X m O 0 EQUIPMENT STORAGE TREATMENT �2 TREATMENT �3 TREATMENT �4 129 128 127 125 TREATMENT �1 130 w NN � Q� � SOILED HOLDING 110 � 2 111 TECH. OFFICE 110 CONF. CONSULT. RM. 109 W1 3 , 5– � � � PASSAGE 126 �-- ------ I I I I II EXIST. BULKHEAD � � ABOVE 60" A. F. F. (PROVIDE STEEL POST @ 48" O.C. CORE DRILLED INTO SLAB) GYM 113 � EQUIP. STORAGE � MECH. 124 12 w 120 122 c.�i� N �� � BIO � `�' 123 �3 �' JANa 1 L4! � \ � � i � N w �� � �� Q � � � � 6" METAL STUDS @ 24" O.C. � II � 1n � 3 � I a, 32�_4 3�4n I 5,_�„ � _ RECEPTION � C° 107 30" A. F. F. II N II I I '' � 42" A. F. F. I I II N II � _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ � 6'_3" 10' 7 3/8" 6,_6n � ��_� 3�8� �,_4„ � PASSAGE i � 106 � — — — — — — EXIST. BULKHEAD —� � ABOVE i � WHEEL OFFICE 1 WAITING � CHAIR —� 108 I TORAG VEST. 102 � � 101 � � � � � � I I � � \► I/8�� _ � �_0�� i � � BREAK RM. 118 '. � , „ '` � , „ , 0l1� ,;,................ : :��„ ;,�, PATIENT i T01 LET '� 116 TREATMENT #5 105 CLEAN STORAGE 104 OFFICE 2 103 NEW 5'X5' CONC. STOOP EXISTING 1–HR. FIRE RATED DEMISING WALL �I�T��� ���� ��8�� _ I �_O�� 0 � WINDOW MULLION .080 ALUM. CLOSURE FINISH TO MATCH MU SIZE THROAT TO REC SYSTEM THICKNESS 7'-0" MIN. 1 " INSULATED GLASS GLAZING TAPE (TYP. EACH SIDE OF MULLION BREAKMETAL) REAKMETAL FOR A =DGE SULATION IN LAST CAVITY INIMUM. PE–"X" GYP. BRD. DES METAL STUDS � �� � @ 16" O.C. 4 7/8» TY� I G�� l�I�LL TO MU�L I O1� D�T� I L ��T�I� I � �� _ I �_0 �� TYi� I G�L TO I L�T iZOOM �����T I �� /�n _ I i_On 7'–�" M�N. TYi� I G�L TO I LET iZOOM �����T I �� ���� _ I �_0�� � 7'-3" MIN. TYi� I G�4L TO I L�T ROOM �����T I �� ���ii _ I i_On ��� �IOT�� 1. WALL MOUNTED GRAB BAR SHOWN WITH 1-1/2" DIAMETER GRIPPING SURFACE WITH 1-1 /2" SPACE BETWEEN WALL. THE BARS SHALL BE MOUNTED ON SOLID WOOD BLOCKING TO RESIST A FORCE OF 250 LBS/FT. MOUNTED (� 36" A.F.F. 2. LAVATORIES: MOUNTED WITH THE RIM NO HIGHER THAN 34" A.F.F. WITH A CLEAR SPACE OF 30"x48". THE MINIMUM DEPTH IS 17", KNEE CLEARANCE OF 8" MINIMUM, AND TOE CLEARANCE OF 6" MAX. HOT AND DRAIN LINES SHALL BE INSULATED. FAUCET HANDLES SHALL BE LEVER TYPE. 3. MIRROR MOUNTED WITH LOWEST POINT C� 40" A.F.F. �i��u�� ������ T�M D�SGi�Ii�TION � TOILET TISSUE DISPENSER 2 ADA FLOOR MOUNTED TOILEf 3 WALL HUNG LAVATORY 4 PAPER TOWEL DISPENSER 5 36" GRAB BAR 6 42" GRAB BAR � 18" GRAB BAR – INSTALL VERTICALLY $ 18" X 36" MIRROR BOTTOM C� 40n A.F.F. 9 22" X 25" DEEP S.S. SINK 10 25" D. LAM. COUNTER TOP � 36" A.F.F. W/ WOOD BASE CABINETS DRAWER STACK & 4" BACK SPLASH 11 PLAM. UPPER WALL CABINETS 12 24" D. LAMINATE WORK SURFACE C� 30" A.F.F. 13 12" D. TRANSACTION TOP W/ 6" SKIRT � 42" AFF 14 6" D. LAMINATE WALL CAP 15 NEW LOCKERS 16 ICE MAKER 17 HYDOCOLLATOR 18 H20 DISPENSER 19 SEMI–RECESSED FIRE EXTINGUIHER CABINET 20 PLASTIC LAMINATE ACCESS BOX ENCLOSURE FOR BACKFLOW PREVENTOR 21 BOX/BOX FILES 22 8' HIGH PLYWOOD PANEL 23 TREATMENT TABLE 27" W. X 76" L. 24 TRACTION TABLE 28" W. X 80" L. 25 BOBATH TREATMENT TABLE 40"W. X 76" L. 26 UC FREEZER 27 COPIER 28 25 D. LAM. TOP C� 34 A.F.F. W LAM. 2 42 W. LATERAL FILES & 2 6" W. DRAWERS 29 42" W. LAM. UPPER WALL CABINETS 30 24"X24" ROLLING CABINET W/ LAM. TOP 31 HAND SANITIZER 32 OPAQUE FILM ON GLASS �IXTU�� 1�OT�� R�M��KS BUILDING STANDARD EXIST. TO REMAIN OR RELOCATED (SEE PLANS EXIST. RELOCATED BUILDING STANDARD EXIST. TO REMAIN OR RELOCATED (SEE PLANS EXIST. TO REMAIN OR RELOCATED (SEE PLANS BUILDING STANDARD EXIST. RELOCATED BUILDING STANDARD BUILDING STANDARD BUILDING STANDARD BUILDING STANDARD BUILDING STANDARD BUILDING STANDARD BY TENANT BY TENANT BY TENANT BY TENANT BUILDING STANDARD BUILDING STANDARD BY TENANT BY TENANT BY TENANT BY TENANT BY TENANT BY TENANT BY TENANT BUILDING STANDARD BUILDING STANDARD BY TENANT BY TENANT 1. PROVIDE FIRE TREATED WOOD OR METAL BLOCKING FOR FIXTURES AS REQUIRED. 2. G.C. TO SUPPLY AND INSTALL ALL FIXTURES LISTED ABOVE U.N.O. 3. ALL FIXTURES LISTED ABOVE SHALL BE "BUILDING STANDARD". VERIFY TYPE, COLOR, & MANUFACTURER W/ OWNER. 4. G.C. TO PROVIDE & INSTALL 'HANDI LAV–GUARD' INSULATION KIT AS MANUFACTURED BY TRUEBRO INC. COLOR: WHITE (VERIFY MODEL #) 5. MILLWORK CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL CABINEfRY FOR TENANT APPROVAL. 6• ALL FAUCETS TO BE ADA COMPLIANT. ���� �OT�� O1 ALIGN NEW WALL WITH CENTERLINE OF MULLION SEE DETAIL 1/A101 O2 ALIGN NEW WALL WITH EDGE OF EXISTING WALL OR COLUMN O3 ALIGN EDGE OF WALL W/ BULKHEAD ABOVE � I I ���Y � �������� NO l�lI1�DOW ���M� R�M��IGS � N � � � � � W� 7'-10 1/2" W. x 3'-6" H WD STD WOOD TRIM TO MATCH DOOR TRIM PROVIDE ONE-WAY FILM ON GLASS ���� ���� I �� EXISTING PARTITION TO REMAIN INSULATED PARTITION 3-5/8" 20 GA. METAL STUDS C� 24" O.C. W/ 5/8" TYPE "X" GYPSUM BOARD EACH SIDE TO ELIMINATOR TRACK C� CLG. PROVIDE 3-1 /2" FIBER GLASS SOUND INSULATION IN WALL CAVITY AND 2'-0" EACH SIDE OF WALL � CEILING LINE. NON–INSULATED PARTITION 3-5 8" 20 GA. METAL STUDS C� 24" O.C. W/ 5 8" TYP "X" GYPSUM BOARD EACH SIDE TO ELIMINA OR TRACK C� CEILING LINE. LOW HEIGHT PARTITION 3-5 8" 20 GA. METAL STUDS � 24" O.C. W 5/8" TYP "Xn GYPSUM BOARD EACH SIDE TO HEI HT INDICATED ON FLOOR PLAN NOTE: ALL GYPSUM BOARD SHALL BE TAPED AND SPACKLED FULL HEIGHT. SAND TO CEILING LINE. PREPARE FOR PAINT/WALLCOVERING. ��0�� �O�U���T� THE DOCUMENTS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF DESIGN CONCEPT, DIMENSIONS, AND MAJOR ARCHITECTURAL ELEMENTS. THESE DOCUMENTS DO NOT NECESSARILY DESCRIBE OR INDICATE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, EACH TRADE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLEfION OF THIS WORK. �� I ����� I ����� 1. THE DRAWINGS AND SPECS. ARE AN INSTRUMENT OF SERVICE AND ARE THE SOLE PROPERTY OF THE ARCHITECT. ANY RE–USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. 2. THE DRAWINGS AND SPECS. ARE THE SOLE PROPERTY OF THE OWNER. ANY RE–USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE OWNER. 3. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS, AND ORDINANCES. 4. VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING. 5. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRAD E. 6. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED. 7. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE DAILY. 8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES. 9. ALL DIMENSIONS ARE FROM FACE OF DRYWALL TO FACE OF DRYWALL. 10. ALL INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 11 ADA – TENANT BUILD OUT DESIGN HAS BEEN BASED UPON OUR ARCHITECTS, LLC ARCHITECTS, PLANNERS 305 East New York Street Indianapolis, Indiana 46204 (317) 656-3500 Fax (317) 656-3501 TRAINING AND UNDERSTANDING OF THE REGULATIONS AND GUIDELINES ISSUED AS COMPONENT PARTS TO TITLE III OF THE AMERICANS WITH DISABILITIES ACT, PUBLIC LAW 101-336. DESIGN RESOLUTION DOES NOT ATTEMPT TO ADDRESS POTENTIAL CONCERNS ASSOCIATES WITH OTHER TITLES OF THE ACT THAT IMPLICATE POLICY, PROCEDURES, AND TELECOMMUNICATIONS ISSUES. 12. ALL EXIT DOOR LOCKS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 13. DOOR CLOSERS AT INTERIOR DOORS SHALL BE ADJUSTED SO THAT � THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL � W NOT EXCEED 5 LBS. � > 14. INTERIOR DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS � � TO MOVE TO A POINT 3 IN. FROM THE LATCH TO THE LEADING EDGE � Q OF THE DOOR. � Q � 15. ALL MECHANICAL WORK SHALL BE IN ACCORDANCE WITH ALL ,� � APPLICABLE CODES OF THE LATEST ADOPTION. W Q � o� — 16. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH ALL � � � Q APPLICABLE CODES OF THE LATEST ADOPTION. � � �� 17. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH ALL � Z — APPLICABLE CODES OF THE LATEST ADOPTION. � � Q � 18. VERIFY WITH 'fiENANT" ALL BUILDING STANDARD � � U� MATERIALS & SYSTEMS. � m . W � W �� � � � � � � p pQ � � 00 U ���� �������� NEW DOORS 8c FRAMES TO MATCH EXISTING m � �n o � � m o m N0. DOOR FRAME HARDWARE REMARKS — �� �� ,.n m �n O Z'� w� p m W dl � � �n z SIZE M A T' L T Y P E M A T' L T Y P E C L O S E R L O C K S T O P v� a o � � _'� o 110 3'-0" x 7'-0" WOOD STD WOOD STD – L1 S "' ° ° v � 116 – – – – – – – S EXIST. RELOCATED CERTIFIED BY 117 – – – – – – – S EXIST. RELOCATED ���G� A. S+� 122 3'-0" x 7'-0� WOOD STD WOOD STD – L2 S � vo,���,isrp�E, °q��� 123 2'-6" x 7'-0" WOOD STD WOOD STD – L2 – Q�o ° 40� • ° 3135 � • e . �a o� t��,%,vo s-r � v .n.�e D I _e _ .��� ���� ���� I �� NOTE: ALL HARDWARE TO BE BUILDING STANDARD. DOOR OPERATION TO BE LEVER TYPE. ALL LOCKSETS TO ACCEPT BEST CORES. (MATCH EXISTING) L1 – PASSAGE SET LZ – STORE ROOM LOCK ��� ���I � FIRST FLOOR � nnTi in ini�v nT NORTH� , % % ��i,; / ��iiii� z � a� � 0 : . • � �RG�+IT�GTUR�L �L�NS � � � � � � � � � 0 Q � 0 0 � PL1 1 X PAINTED WOOD BASE TO MATCH EXISTING � � � � � �� m � �� m � � � � � � � � x m O 0 ._ � - - .� � - r ; . �����T I �� � I/��� _ ��_��� �LI\I VI\/'11LU IVILI/'iL VV� JI/'iIVU—VI I J VVLI\ �LI PROVIDE STAINLESS STEEL TRIM ALL (4) SIDES PL1 � i � EXISTING CABINEfRY TO REMAIN TYP. OPEN SHELF W/ PLAM. BACK FREEZER HYDOCOLLATOR PL1 CE MAKER � � � � � � - � � � � � , � �\ , � �\ � � � � � � � � � � -- -- � � � � � � � , , --- ---- ---- --------- ---- --- � � � � � , � � , � i � � i � � i , � \� \\�� �i�/ \� \\�� �i�/ �i � PL2 � ,,'u l�� ��1 v e e � e e v � � � ,-uu�� ,-uu�� � � � i � e i � ° i � i � ° � � i � � i ° � � _ � � _ � � , � � � � � � � � � � � � i � � � � � 2'-0" 3'-0" 1'-6" 2'-0" 2'-0" 1'-6" 2'-0" 2'-0" 1'-6" � �����T I �� � ����� _ I �_��� EQ. EQ. EQ. EQ. EQ. EQ. 18,_0„+ (VERIFY IN FIELD) �����T I �� 3 �/��� _ � �_o�� � i N 1 X PAINTED WOOD BASE TO MATCH EXISTING 2,-6„ 2'-7 7/8„ SSI � � i � �����T I �� 6 I/�F�� _ � �_0�� I��I � o � I � N i / O i � � _� � i N PL1 � I N � i O � N �� PL2 TYP. OPEN SHEL W/ PLAM. BACK METAL (BLACK) WALL BRACKET ' 3'-6" � � PL1 � -- � � �_ �- -� � � , , � � � i N \ PL2 � � e e N � � N N � � PI 1 � i N O i N O � N II.���:1_1�y1�� �����T I �� 2 ����� _ I �_��� EQ. EQ. EQ. 9,_0„+ (VERIFY IN FIELD) I,�I � o � I � N i / O i � � _� � � � � — N �����T I �� 4 �/��� _ � �_o�� �.v� �-�-� n� irR 3/4" PLYWOOD 3LOCKING ���T I �� � �/4�� _ � �_0�� 3 5/8" METAL STUDS @ 24" O.C. W/ 5/8" GYP. BRD. BOTH SIDES 1 X PAINTED WOOD BASE TO MATCH EXISTING ARCHITECTS, LLC ARCHITECTS, PLANNERS 305 East New York Street Indianapolis, Indiana 46204 (317) 656-3500 Fax (317) 656-3501 � � � � � � � � Q � z � � W � � � � o �p � � �Z � Z Q— o � � � U� � m .w � W �� �� � �� � 0 O Q � � 00 U m � �n � � � m o m � N � W� O z� W� Z m O Ll � cV \ 0 0 U � CERIIFIED BY GK A. �Q��` OOipO0000000 �i� ,��G,ISTE�,o��0 Q� :2 e . • ° 3135 � • . e . �a o� t��,%,vo s-r � v .n.�e D I _e _ .��� NORTH� � � i //% � ����iii� 0 � a� � 0 a 0 . • � NT�RIOR �L�V�TIONS � m m � � � � � 0 � m O 0 INCOMING 2"� COPPER DOMESTIC WATER LI N E EXIST. C.O. � NEW 2"� SAN SEE NOTE m � � �� � � �� �� � X m O m� i■�.�.r.���r.ur,���a�r►,r�■».m.��.�■i■i�.T.m■�r � "� � � � • � �8 �� _ I �_0 �� NOTES: T. 4"� SAN ITARY �AL. WATER HEATER ING. PC TO INSTALL �CALD DEVICE EQUAL JS TEMPCONTROL; 00 SEE NOTE �2 1. PROVIDE NEW 2" SANITARY STUB 8c CAP PROVIDE 1 1/2"� PVC IN WALL TO CEILING LINE FOR FUTURE VENT LINE 2. REVISE 1 1/2" VENT LINES TO ACCOMMODATE REVISED PLUMBING LAYOUT. � � � � i � � � � � � , � � � � � � i � � � ��� ��U�I`�I�� �OT�� THE HVAC, ELECTRICAL/VOICE/DATA/ALARM & PLUMBING DRAWINGS CONTAINED HEREIN ARE SCHEMATIC IN NATURE AND SERVE ONLY TO CONVEY THE »INTENTn OF THE TENANT'S REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD CONTRACTORS TO FULLY ENGINEER THESE SYSTEMS. SEALED DRAWINGS ARE NOT REQUIRED UNLESS STATE OTHERWISE; HOWEVER, DRAWINGS SHALL BE PREPARED AS SHOP DRAWINGS AND SUBMITTED TO THE ARCHITECT FOR APPROVAL. HVAC • THE HVAC CONTRACTOR SHALL FURNISH & INSTALL ALL NECESSARY DUCTWORK, DIFFUSERS AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES & ORDINANCES. • THE HVAC CONTRACTOR SHALL nBALANCE" THE SYSTEM PRIOR TO THE TENANT'S MOVE-IN DATE. • THE HVAC CONTRACTOR SHALL VERIFY WITH THE TENANT HOW THE SYSTEM IS TO BE "ZONED" AND IDENTIFY THE LOCATION OF ALL THERMOSTATS. • PROVIDE nSOUND BOOTSn IN ALL RETURN AIR GRILLS IN ALL AREAS. ELECTRICAL/VOICE/DATA SYSTEMS • THE ELECTRICAL CONTRACTOR SHALL FURNISH & INSTALL ALL NECESSARY CONDUIT, WIRING, PANELS, LIGHTING, ELECTRICAL DEVICES, SWITCHES AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES & ORDINANCES. • THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS AS TO THE REQUIREMENTS FOR THE VOICE/DATA SYSTEMS. • THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BASE BUILDING OWNER AS TO THE ADEQUACY OF THE EXISTING ELECTRICAL SERVICE AND MODIFICATIONS WHICH MAY BE REQUIRED TO ACCOMMODATE THIS TENANT. • THE ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL ALL ELECTRICAL PANELS & CIRCUITS. • THE ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL ELECTRICAL OUTLETS THAT ARE DEDICATED. PLUMBING • THE PLUMBING CONTRACTOR SHALL FURNISH & INSTALL ALL NECESSARY PIPING, FIXTURES, AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. • ALL NEW AND EXISTING HOT WATER LINES SHALL BE INSULATED. • ALL NEW AND EXISTING PVC OVERHEAD PIPING ABOVE THE CEILINGS SHALL BE WRAPPED WITH "FIRE TAPE". ��0�� �O�U�M`��T� THE DOCUMENTS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF DESIGN CONCEPT, DIMENSIONS, AND MAJOR ARCHITECTURAL ELEMENTS. THESE DOCUMENTS DO NOT NECESSARILY DESCRIBE OR INDICATE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, EACH TRADE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THIS WORK. �� I ����� I ����� 1. THE DRAWINGS AND SPECS. ARE AN INSTRUMENT OF SERVICE AND ARE THE SOLE PROPERTY OF THE ARCHITECT. ANY RE-USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. 2. 3. 4. 5. 6. 7. 8. 9. 10. THE DRAWINGS AND SPECS. ARE THE SOLE PROPERTY OF THE OWNER. ANY RE-USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE OWNER. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS, AND ORDINANCES. VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE DAILY. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES. ALL DIMENSIONS ARE FROM FACE OF DRYWALL TO FACE OF DRYWALL. ALL INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 11. ADA - TENANT BUILD OUT DESIGN HAS BEEN BASED UPON OUR TRAINING AND UNDERSTANDING OF THE REGULATIONS AND GUIDELINES ISSUED AS COMPONENT PARTS TO TITLE III OF THE AMERICANS WITH DISABILITIES ACT, PUBLIC LAW 101-336. DESIGN RESOLUTION DOES NOT ATTEMPT TO ADDRESS POTENTIAL CONCERNS ASSOCIATES WITH OTHER TITLES OF THE ACT THAT IMPLICATE POLICY, PROCEDURES, AND TELECOMMUNICATIONS ISSUES. 12. 13. ALL EXIT DOOR LOCKS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. DOOR CLOSERS AT INTERIOR DOORS SHALL BE ADJUSTED SO THAT THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL NOT EXCEED 5 LBS. 14. INTERIOR DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 IN. FROM THE LATCH TO THE LEADING EDGE OF THE DOOR. 15. 16. 17. 18. ALL MECHANICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. VERIFY WITH 'fiENANT" ALL BUILDING STANDARD MATERIALS & SYSTEMS. ��� ���I � FIRST FLOOR ARCHITECTS, LLC ARGHITECTS, PLANNERS 305 East New York Street Indianapolis, Indiana 46204 (317) 656-3500 Fax (317) 656-3501 � � � � � � � � � � � � W � - � � Q � Z wQ � � LL � � � Z Z Q ^ � � � U m . W � ��W CA � � � 0 oa � oo U m o � �� u� O a� '�-'�r � o 0 CERIIFIED BY� � m o m m � z � W � Z m � o ='� o 0 U � K A. ��� °ooevoeo s�� �Q�,��G,ISTE�,00�O Q� �� . e • e 3135 � • e e �� �� t�`�'%,e� s-r �° v � . A.�e D I _e _ .�'��I NORTH� � ��� % /� ,,�,� z O � a� U � w 0 a 0 � SHEET N0. �LUM� I N6 PL�N � � w � Q � 0 c� � � � � � � � 0 � � 0 0 � nirini nirn ic-rn ���� ��� I � �8�� _ ��_o�� � � � � � �� m � �� m � � � � � � � � � � X m O 0 EXIST. CONDENSER #2 (CLEAN COIL) EXIST. GAS FIRED UP-FLOW FURNACE �1 90 MBH INPUT EXIST. GAS FIRED UP-FLOW FURNACE �2 90 MBH INPUT NEW 90 CFM EXHAUST FAN ���� I �� ����, ����T� I ��� �1�� ��U��I�� �Ofi�� THE HVAC, ELECTRICAL/VOICE/DATA/ALARM & PLUMBING DRAWINGS CONTAINED HEREIN ARE SCHEMATIC IN NATURE AND SERVE ONLY TO CONVEY THE nINTENT" OF THE TENANT'S REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD CONTRACTORS TO FULLY ENGINEER THESE SYSTEMS. SEALED DRAWINGS ARE NOT REQUIRED UNLESS STATE OTHERWISE; HOWEVER, DRAWINGS SHALL BE PREPARED AS SHOP DRAWINGS AND SUBMITTED TO THE ARCHITECT FOR APPROVAL. HVAC • THE HVAC CONTRACTOR SHALL FURNISH & INSTALL ALL NECESSARY DUCTWORK, DIFFUSERS AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES & ORDINANCES. • THE HVAC CONTRACTOR SHALL "BALANCE" THE SYSTEM PRIOR TO THE TENANT'S MOVE—IN DATE. • THE HVAC CONTRACTOR SHALL VERIFY WITH THE TENANT HOW THE SYSTEM IS TO BE "ZONEDn AND IDENTIFY THE LOCATION OF ALL THERMOSTATS. • CLEAN & REPLACE ALL AIR FILTERS. * PROVIDE nSOUND BOOTS" IN ALL RETURN AIR GRILLS IN ALL AREAS. ELECTRICAL/VOICE/DATA SYSTEMS • THE ELECTRICAL CONTRACTOR SHALL FURNISH & INSTALL ALL NECESSARY CONDUIT, WIRING, PANELS, LIGHTING, ELECTRICAL DEVICES, SWITCHES AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES & ORDINANCES. • THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS AS TO THE REQUIREMENTS FOR THE VOICE/DATA SYSTEMS. • THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BASE BUILDING OWNER AS TO THE ADEQUACY OF THE EXISTING ELECTRICAL SERVICE AND MODIFICATIONS WHICH MAY BE REQUIRED TO ACCOMMODATE THIS TENANT. • THE ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL ALL ELECTRICAL PANELS & CIRCUITS. # THE ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL ELECTRICAL OUTLETS THAT ARE DEDICATED. PLUMBING • THE PLUMBING CONTRACTOR SHALL FURNISH & INSTALL ALL NECESSARY PIPING, FIXTURES, AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. • ALL NEW AND EXISTING HOT WATER LINES SHALL BE INSULATED. • ALL NEW AND EXISTING PVC OVERHEAD PIPING ABOVE THE CEILINGS SHALL BE WRAPPED WITH "FIRE TAPE". � Y �� ���� I `l� � � O 4 � � EXISTING DIFFUSER EXISTING RETURN AIR GRILLE RELOCATED DIFFUSER (EXTEND 8" DUCT FROM ADJACENT DUCT) RELOCATED RECESSED EXHAUST FAN EXISTING SLOT DIFFUSER NEW DIFFUSER. EXTEND 8n DUCT FROM ADJACENT DUCT. ��0�� �O�U���T� THE DOCUMENTS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF DESIGN CONCEPT, DIMENSIONS, AND MAJOR ARCHITECTURAL ELEMENTS. THESE DOCUMENTS DO NOT NECESSARILY DESCRIBE OR INDICATE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, EACH TRADE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLEfION OF THIS WORK. ������� �OT�� 1. THE DRAWINGS AND SPECS. ARE AN INSTRUMENT OF SERVICE AND ARE THE SOLE PROPERTY OF THE ARCHITECT. ANY RE-USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. 2. 3. 4. 5. 6. 7. 8. 9. 10. THE DRAWINGS AND SPECS. ARE THE SOLE PROPERTY OF THE OWNER. ANY RE-USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE OWNER. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS, AND ORDINANCES. VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE DAILY. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES. ALL DIMENSIONS ARE FROM FACE OF DRYWALL TO FACE OF DRYWALL. ALL INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 11. ADA - TENANT BUILD OUT DESIGN HAS BEEN BASED UPON OUR TRAINING AND UNDERSTANDING OF THE REGULATIONS AND GUIDELINES ISSUED AS COMPONENT PARTS TO TITLE III OF THE AMERICANS WITH DISABILITIES ACT, PUBLIC LAW 101-336. DESIGN RESOLUTION DOES NOT ATTEMPT TO ADDRESS POTENTIAL CONCERNS ASSOCIATES WITH OTHER TITLES OF THE ACT THAT IMPLICATE POLICY, PROCEDURES, AND TELECOMMUNICATIONS ISSUES. 12. 13. ALL EXIT DOOR LOCKS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. DOOR CLOSERS AT INTERIOR DOORS SHALL BE ADJUSTED SO THAT THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL NOT EXCEED 5 LBS. 14. INTERIOR DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 IN. FROM THE LATCH TO THE LEADING EDGE OF THE DOOR. 15. � ALL MECHANICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 17. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 18. VERIFY WITH "TENANT" ALL BUILDING STANDARD MATERIALS 8c SYSTEMS. �� ��� I � FIRST FLOOR ARCHITECTS, LLC ARCHITECTS, PLANNERS 305 East New York Street Indianapolis, Indiana 46204 (317) 656-3500 Fax (317) 656-3501 � � � � � � � � � W � — � � Q � Z W � 0 � LL � � � Z Z Q ^ � � � U m . W � �� W � � � � Q 0 Q � oo U m O � � �� �n O a� �"� � o 0 CERIIFIED BY � m o m m � z � W � Z m � n ='i o 0 U � GK A. �Q��` OOipO0000000 �i� ,��G,ISTE�,o��0 Q� :2 e . • ° 3135 � • . e . �a o� t��,%,vo s-r � v � .n.�e D I _e _ .�'��I NORTH� z O � a� � w 0 a 0 � SHEET N0. � � i //% � ����iii� HY�G �L�N � � c� � � � � � � 0 z � 0 0 � A g,_�>, � � � � � � m m � N m � � � � �J ' � � � X O 0 i i � LL_ i ,_ I '- � �i- �!- � � � � L�_ � �- � � � O � � � � � C � u o n � 0 � � _ � � - � C � O � � � � � �° I� ° � n n � O vl Iv O II I I I II O II I I I II O 0 a 0 � ] 0 0 0 0 � � � � � � O O O O O � � ❑ ❑ ❑ ❑ � n n n � o� o 0 �� �� � �� �� �� � n n n n � C � . � C� u � ❑O O � ������T�� ��I�I�� ���� C O f � � � VI O O VI IV � � � ��� '�JI,�/1[� 0 B g,_�,> A g,_�„ r"' �TING PANEL "A" iTING PANEL "B" 1 J j� ,�� � �� �� L/\IJIIIVV YY � L IVIVVIVILL/ LLLI��I\Ilil'1L I ILI'11L1\ �9 � � TO REMAIN CLEAN & SERVICE I �� ��8�� _ I �_O�� OTE: EXISTING ELECTRICAL PANELS ARE BOTH 200 AMP 120/208V 3 PHASE — 4 WIRE (42 BREAKERS) �I �I ����� ������ I ��� ��������� �� I � I I �� ���� I �� THE DOCUMENTS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF ;=�:�:�y;':::�;����:�=� GYP. BRD. CEILING THE PROJECT IN TERMS OF DESIGN CONCEPT, DIMENSIONS, AND MAJOR ARCHITECTURAL ELEMENTS. THESE DOCUMENTS DO NOT NECESSARILY DESCRIBE OR INDICATE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE EXISTING 2'X2' CEILING GRID & TILE TO REMAIN BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, EACH TRADE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THIS WORK. NEW 2'X2' CEILING GRID & TILE TO MATCH EXISTING �� I ����� I ����� � EXISTING 2'x2' LAY—IN FLUORESCENT LIGHT FIXTURE 1. THE DRAWINGS AND SPECS. ARE AN INSTRUMENT OF SERVICE AND ARE THE SOLE PROPERTY OF THE ARCHITECT. ANY RE—USE OR � RELOCATED 2'x2' LAY—IN FLUORESCENT LIGHT FIXTURE DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. $ WALL MOUNTED LIGHT SWITCH 2. THE DRAWINGS AND SPECS. ARE THE SOLE PROPERTY OF THE OWNER. ANY RE—USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED � EXISTING EXIT SIGN WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE OWNER. E EXISTING EMERGENCY LIGHTING 3. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS, AND ORDINANCES. � EXISTING DIFFUSER 4. VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING. � EXISTING RETURN AIR GRILLE 5. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE O RELOCATED DIFFUSER TRADE. 6. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED � RELOCATED RECESSED EXHAUST FAN BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED. � EXISTING SLOT DIFFUSER 7• EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE DAILY. � NEW DIFFUSER 8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES. 9. ALL DIMENSIONS ARE FROM FACE OF DRYWALL TO FACE OF DRYWALL. 10. ALL INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. ���� T� I��� ���� I�l� 11. ADA — TENANT BUILD OUT DESIGN HAS BEEN BASED UPON OUR TRAINING AND UNDERSTANDING OF THE REGULATIONS AND GUIDELINES ISSUED AS COMPONENT PARTS TO TITLE III OF THE AMERICANS WITH DISABILITIES ACT, PUBLIC LAW 101-336. DESIGN RESOLUTION DOES Ex� EXISTING WALL MOUNTED DUPLEX OUTLET NOT ATTEMPT TO ADDRESS POTENTIAL CONCERNS ASSOCIATES WITH OTHER TITLES OF THE ACT THAT IMPLICATE POLICY, PROCEDURES, Ex� EXISTING WALL MOUNTED QUADRUPLEX OUTLET AND TELECOMMUNICATIONS ISSUES. 12. ALL EXIT DOOR LOCKS SHALL BE IN ACCORDANCE WITH ALL Ex� EXISTING WALL MOUNTED COMBINATION TELEPHONE/DATA LINE APPLICABLE CODES OF THE LATEST ADOPTION. Ex� EXISTING WALL MOUNTED TELEPHONE LINE 13. DOOR CLOSERS AT INTERIOR DOORS SHALL BE ADJUSTED SO THAT THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL Ex0 EXISTING FLOOR MOUNTED COMBINATION ELECTRICAL & TELEPHONE/DATA LINE NOT EXCEED 5 LBS. 14. INTERIOR DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN � WALL MOUNTED DUPLEX OUTLET POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 IN. FROM THE LATCH TO THE LEADING EDGE WALL MOUNTED DUPLEX OUTLET — GFI OF THE DOOR. �GFI 15. ALL MECHANICAL WORK SHALL BE IN ACCORDANCE WITH ALL � WALL MOUNTED DUPLEX OUTLEf — DEDICATED APPLICABLE CODES OF THE LATEST ADOPTION. D WALL MOUNTED QUADRUPLEX OUTLET 16. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH ALL � APPLICABLE CODES OF THE LATEST ADOPTION. Q WALL MOUNTED COMBINATION TELEPHONE/DATA LINE 17. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. b WALL MOUNTED TELEPHONE LINE 18. VERIFY WITH 'fiENANT" ALL BUILDING STANDARD � TELEVISION BY TENANT (VERIFY HEIGHTS) MATERIALS & SYSTEMS. ��I�I�� T��� ������ A— 2'X2' ACOUSTICAL CEILING TILES TO MATCH EXISTING — TYPE 6 — DRYWALL CEILING — HEIGHT ���� I �� #����, ����T� I ��� ��� ��U�M`�I�l� �OT�� THE HVAC, ELECTRICAL/VOICE/DATA/ALARM & PLUMBING DRAWINGS CONTAINED HEREIN ARE SCHEMATIC IN NATURE AND SERVE ONLY TO CONVEY THE "INTENTn OF THE TENANT'S REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD CONTRACTORS TO FULLY ENGINEER THESE SYSTEMS. SEALED DRAWINGS ARE NOT REQUIRED UNLESS STATE OTHERWISE; HOWEVER, DRAWINGS SHALL BE PREPARED AS SHOP DRAWINGS AND SUBMITTED TO THE ARCHITECT FOR APPROVAL. HVAC • THE HVAC CONTRACTOR SHALL FURNISH & INSTALL ALL NECESSARY DUCTWORK, DIFFUSERS AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES & ORDINANCES. + THE HVAC CONTRACTOR SHALL "BALANCEn THE SYSTEM PRIOR TO THE TENANT'S MOVE—IN DATE. � THE HVAC CONTRACTOR SHALL VERIFY WITH THE TENANT HOW THE SYSTEM IS TO BE nZONED" AND IDENTIFY THE LOCATION OF ALL THERMOSTATS. • IN EXISTING SPACES BEING FULLY OR PARTIALLY DEMOLISHED, ALL HVAC SUPPLY AND RETURN DIFFUSERS SHALL BE NEW. � PROVIDE "SOUND BOOTSn IN ALL RETURN AIR GRILLS IN ALL AREAS. ELECTRICAL/VOICE/DATA SYSTEMS • THE ELECTRICAL CONTRACTOR SHALL FURNISH & INSTALL ALL NECESSARY CONDUIT, WIRING, PANELS, LIGHTING, ELECTRICAL DEVICES, SWITCHES AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES & ORDINANCES. � THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE TENANT'S VENDORS AS TO THE REQUIREMENTS FOR THE VOICE/DATA SYSTEMS. • THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BASE BUILDING OWNER AS TO THE ADEQUACY OF THE EXISTING ELECTRICAL SERVICE AND MODIFICATIONS WHICH MAY BE REQUIRED TO ACCOMMODATE THIS TENANT. • THE ELECTRICAL CONTRACTOR SHALL PERMANENTLY LABEL ALL ELECTRICAL PANELS & CIRCUITS. � THE ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL ELECTRICAL OUTLETS THAT ARE DEDICATED. PLUMBING • THE PLUMBING CONTRACTOR SHALL FURNISH & INSTALL ALL NECESSARY PIPING, FIXTURES, AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. • ALL NEW AND EXISTING HOT WATER LINES SHALL BE INSULATED. � ALL NEW AND EXISTING PVC OVERHEAD PIPING ABOVE THE CEILINGS SHALL BE WRAPPED WITH nFIRE TAPE". ��� ��� I � FIRST FLOOR � nnTi in ininv nT ARCHITECTS, LLG ARCHITECTS, PLANNERS 305 East New York Street Indianapolis, Indiana 46204 (317) 656-3500 Fax (317) 656-3501 W � � � � Q � _ a � JZ � wQ � � � LL � � � �Z � Z Q 0 � � � UJ �� m . W � o �� � W � 0 � � � au u o p Q � � oo U m n! cn o � � m o m �� , i m ct) �� O a� � o � w� m m 0 0 � cVn � 0 U � CERTIAED BY� ���K A . �Q�o.00e.o.o s,� o���,�srE,q�.00�0 Qo o� . . . e • e 3135 � • . e �� .� ��i,�e ST � V . A.�e D I _e _ .�'`�4 •- ; %/, ; �/i ��ii 0 � a� U � w 0 � c� w � � 0 � � � Q N � � � � � SHEET N0. � � � � 0 w � �L�GTRIG�L �L�NS o � m. BREAK RM. 118 m � �. � �� - � _ - . � �� - I/8 �� - � �_0 �� ,I����/���I��T�T �I�I�� ���� /8 �� _ � �_0 �� ��� ���I � FIRST FLOOR � �� nnTi in inirni nT ��0�� �O�U��1�T� THE DOCUMENTS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF DESIGN CONCEPT, DIMENSIONS, AND MAJOR ARCHITECTURAL ELEMENTS. THESE DOCUMENTS DO NOT NECESSARILY DESCRIBE OR INDICATE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, EACH TRADE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THIS WORK. ������� �OT�� 1. THE DRAWINGS AND SPECS. ARE AN INSTRUMENT OF SERVICE AND ARE THE SOLE PROPERTY OF THE ARCHITECT. ANY RE-USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. 2. THE DRAWINGS AND SPECS. ARE THE SOLE PROPERTY OF THE OWNER. ANY RE-USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE OWNER. 3. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS, AND ORDINANCES. 4. VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING. 5. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. 6. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED. 7. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE DAILY. : � � THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES. ALL DIMENSIONS ARE FROM FACE OF DRYWALL TO FACE OF DRYWALL. ALL INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. � I I � I �� ���� I �� �L���J - EX EXISTING FLOORING TO REMAIN W�LK-0�� M�T WM1 MANUFACTURER: SHAW CONTRACT GROUP STYLE: BON JOUR COLOR: CHOCOLATE NUMBER: #10122 INSTALLATION: QUARTER TURN G��i��T T I L� C1 MANUFACTURER: BIGELOW STYLE: STRUCTURED MOTION COLOR: BIRCHBARK NUMBER: #7721 INSTALLATION: QUARTER TURN YINYL GOMP051TION TIL� V1 MANUFACTURER: ARMSTRONG STYLE: MIGRATIONS COLOR: GOLDEN SAND NUMBER: #T3513 V2 MANUFACTURER: ARMSTRONG STYLE: STANDARD EXCELON COLOR: TEA GARDEN GREEN NUMBER: #51872 ��s� 0 WOOD ��5� W61 PAINTED WOOD — MATCH EXISTING PROFILE — PAINT P2 � I NYL W�LL ��5� 61 MANUFACTURER: JOHNSONITE — 4" H. COLOR: BURNT UMBER NUMBER: #63 B2 MANUFACTURER: JOHNSONITE — 6" H. COLOR: BURNT UMBER NUMBER: #63 ����� 0 P� I NT/�PDXY P� I NT (� _�PDXY P� I NT) P1 MANUFACTURER: SHERWIN WILLIAMS COLOR: INTERACTIVE CREAM NUMBER: #SW6113 FINISH: EGGSHELL P2 MANUFACTURER: SHERWIN WILLIAMS COLOR: INDIAN WHITE NUMBER: #SW0035 FINISH: SEMI—GLOSS ALL DOOR FRAMES AND WOOD BASE TO BE PAINTED P3 MANUFACTURER: COLOR: NUMBER: FINISH: P4 MANUFACTURER: COLOR: NUMBER: FINISH: G��11��`i�� — i�L�ST I G L�M I N�TE L1 MANUFACTURER: COLOR: NUMBER: L2 MANUFACTURER: COLOR: NUMBER: L3 MANUFACTURER: COLOR: NUMBER: 50L I D SUR��G� SS1 MANUFACTURER: COLOR: SHERWIN WILLIAMS WICKERWORK #SW0010 EGGSHELL SHERWIN WILLIAMS OYSTER BAY #SW6206 EGGSHELL FORMICA AMBER MAPLE #7012-58 NEVAMAR AGED ELEMENTS #EM6001T CHEMEfAL GRILLE STAINLESS STEEL ALUMINUM #103 CORIAN SHALE ARCHITECTS, LLG ARCHITECTS, PLANNERS 305 East New York Street Indianapolis, Indiana 46204 (317) 656-3500 Fax (317) 656-3501 `U 11 � � � � � `U 11 � � � _ 1 W � — � � Q Z J WQ � � LL � � � � Z Q ^ ° J � U m w � � � W � O � � Q � O � oo U � � � m O m N �� , i m cn �� w� 3= U� z m 0 0 � cVn � 0 U � CERTIAED BY� K A. �Q���c s,� oe.vo.e.. ,��G,ISTE�,oe�O Qo °e2 � . . tJ� . e • g 3135 : • � °; ST 0 ° V ��n�e � D I _o _ .��� �f►C�7:i1:9 O � a� � 0 a 0 � o� SHEET N0. , � � ///r � ; �,�i� � � I N I 5� i�L�NS � � W � � �o � � � � � � � � 0 � �� 0 0 �