MODEL 9G CL 1 CLAMP
V UIYJUL /LAA 1 W C7ULLt /IN bf- l UU
MODEL L.S.C.-2 (N. 0. & N.C.)
FLOAT SWITCH
Note
Contractor Shall Contact The Utilities Manager
Prior To Purchasing Any Equipment For This
Lift Station To Verify Proper Interpretation
Of Specifications And Plans.
Note: All Discharge Piping Within
Pumping Station And Valve Box
Shall Be 6" D.4 Flanged.
4" PVC, SDR -21 Air Duct (Run Air Duct To One Foot Above
The Influent Pipe Invert). Position Air Duct So That A Hose Homestead Plug Volve Ductile Iron "T' Pi
Can Be Attached Without Interfering With The Door. Pump Hoist Socket g Pipe With Riser
3" /.D. Pipe Grouted Thru Slab Clean Out - "T" Plug Valve & 1" Brass Drain Valve
M..
z
0
w
Check Valve With Outside
1" PVC, Sch. 40 Weight &Level O.S.H.A. Approved Ladder Mounted
To Wall With Non - Corrosive Material.
v ► 1 14'- 8" (Min.) CIE a
12 Influent Pipe
wit
X.
/ \ ° • ' / - Sure
�
Solid `,
r �' aY
/ \\ ► Manhole I a• Ov .••
° I I , 4 .... .... . Off(
• : o - - _ ° - - Cover / Q�
e
p \
12 F/ygt Pump -.
Model CP -3127 1 v. • . ' . D -
► .4. Wall Sleeve ;j
8" influent Pipe 10" ° • • • . ' .. D .
o — _— ° — —
4" Ductile Iron By -Pass �, ° / - . • D -- -- VP A
4 Ductile Iron Emergency Suction Pipe i /
Position So That Suction Pump Hose Can
Be Attached Without Interfering With The ,� D
Door Or Other Structures. Do Not Locate
In Front Of An Influent Pipe.
_ Type "C" 4.
D
No #,s 11 Wall Sleeve
Size Of Lid Opening Determined By Size Of Pumps And
Shall Be Off Set To Be Over Ladder And Lid To Open
Away From Control Box.
END VIEW FRONT VIEW
CONTROL PANEL
N. T. S.
No
1. The Centro/ Panel is To Face (Open To) The Lift Station Hatch
2. Size Of Cabinet To Be Larger For Stations With bumps Larger
Phan 20 Hp.
J. Alarm Working Lights To Use 60 To 100 Watt, 110 VAC Bulbs.
Fixtures & The Connection To Control Box To Be Totally
Weteeproof. flixtwvs To Novo Integral Guard Or Shield For
ProteCtlon-
4. A Sgw m 0 Transfer Switch Shall Be Provided.
W (Float Heads)
PVC (Motor Heads)
'VC To Meter Pit
:oncrete Pad
semen t
Meter
Radio ,
•
f foot Mounting Pole
Minimum 6" Open Space O.S.H.A. Approved Non - Corrosive Ladder,
Mounted To M.H. With Non - Corrosive Materials.
D.
►ct Switch
Stainless Steel Or
Aluminum Unistrut
— 100 Amp.
Transfer Switch
Stainless Steel Note:
Or 3' Aluminum All Electrical Connections From Bock To The
Channel. Pone/ Shall Be Made Into The Bottom Of The
Panel.
See Constant Speed Or Variable Speed
Electrical Schematic Sheets For
Additional Informations.
TYPICAL UNDERGROUND SERVICE
ON THE BACK OF PANEL
N. T. S
6" D. 1. M. J.
Force Main
4" PVC, SDR -21
Air Duct With Screen.
PLAN VIEW - LIFT STATION
SCALE. 314" — 1'-0'
— Sheet Meta/ Or Laminated Fiber Concrete
Form Adequote /y Braced In Field And
Stripped Out Before Installing Pipe, Except
In Masonry Where Sleeve Shall Be 3116" Steel
And Shall Be Installed With Masonry.
a. Inside Woll
• a a
Service Pipe
Stainless Steel Bolts
a
• 4 d �
�- Modular Mechanical Type Seal
Of Interlocking Synthetic Rubber
Links.
TYPE C
PIPE SL EEVE
N. T.S.
Note:
I. Walls Shall Be Core Drilled Where Shown
And Elsewhere /f Approved By The Engineer.
2. Concrete Shall Be Worked In And Vibrated To
Eliminate Al/ Voids In Concrete - if Voids Do
Remain, F,ll With Grout Before Installing Pipe
And Rubber Seas.
Plug Valve
I I
5 Pipe 0 Minimu '� • ' .'
ICIo•
3 Pipe p Minimu I I •
Type "C" `-
Wall Sleeve I
Precast Pit Acceptable On Submittal j I V-
Poured Concrete With One Layer Of I I (Min.)
Water Proofing.
Transition Fitting And Red
Note• Required To Change From
Asphalt Drive, 10' -0" Wide Shall Be Furnished D -L To 8" Pvc Force I
From Nearest Street Surface To Concrete Pad Outside Of Station.
And Valve Vault.
- Valve Pit Size To Be Determined By The
Area Needed To Put In The Required
Components As Specified.
Cm
Will,
U_
W
U
9U
30-
W
s
e�
W
W
z
i
W
O
Z
r--
O
V
w
.r
M
A
v
m
rn
a
vo
M a1
Supported Pipe Or Valve.
Z
1" Threaded Steel Ro
Weld
318" Thick X 3" Wide Steel Plate
Rolled To Fit Pipe Radius.
,Q
Y
To Rolled Plate.
�...
Hex. Nut & Lock Nu
Nut
LLJ
V
(Loose)
2" Standard Steel Pipe
i
(Length As Required)
Threaded Pipe Cap Drilled
To Accommodate Steel
Rod.
6" Sq. X 318" Thick Steel Plate
Weld
1
To Pipe Or Threaded Pipe Flange.
LJ
.' . •.
•.
Z
1" Grout.
Q
2 _ 1/2"
j
Expansion Bolts.
a
ADJUSTABLE
PIPE SUPPORT
Z
Z
N. T. S.
0
Note:
�.�.
Pipe Supports Shall Be Spaced Not
Q
More Than 12' -0" On Center.
Support
j
Piping Near
Vo/ves, Flowmeters,
Each Side Of
Q
And Couplings.
(
LL
J
.J
V
SHEET N0.
15
28 SHEETS
[_OF
aeNO.
18465.