Loading...
HomeMy WebLinkAbout26-96.20N nl .•1 M M MODEL 9G CL 1 CLAMP V UIYJUL /LAA 1 W C7ULLt /IN bf- l UU MODEL L.S.C.-2 (N. 0. & N.C.) FLOAT SWITCH Note Contractor Shall Contact The Utilities Manager Prior To Purchasing Any Equipment For This Lift Station To Verify Proper Interpretation Of Specifications And Plans. Note: All Discharge Piping Within Pumping Station And Valve Box Shall Be 6" D.4 Flanged. 4" PVC, SDR -21 Air Duct (Run Air Duct To One Foot Above The Influent Pipe Invert). Position Air Duct So That A Hose Homestead Plug Volve Ductile Iron "T' Pi Can Be Attached Without Interfering With The Door. Pump Hoist Socket g Pipe With Riser 3" /.D. Pipe Grouted Thru Slab Clean Out - "T" Plug Valve & 1" Brass Drain Valve M.. z 0 w Check Valve With Outside 1" PVC, Sch. 40 Weight &Level O.S.H.A. Approved Ladder Mounted To Wall With Non - Corrosive Material. v ► 1 14'- 8" (Min.) CIE a 12 Influent Pipe wit X. / \ ° • ' / - Sure � Solid `, r �' aY / \\ ► Manhole I a• Ov .•• ° I I , 4 .... .... . Off( • : o - - _ ° - - Cover / Q� e p \ 12 F/ygt Pump -. Model CP -3127 1 v. • . ' . D - ► .4. Wall Sleeve ;j 8" influent Pipe 10" ° • • • . ' .. D . o — _— ° — — 4" Ductile Iron By -Pass �, ° / - . • D -- -- VP A 4 Ductile Iron Emergency Suction Pipe i / Position So That Suction Pump Hose Can Be Attached Without Interfering With The ,� D Door Or Other Structures. Do Not Locate In Front Of An Influent Pipe. _ Type "C" 4. D No #,s 11 Wall Sleeve Size Of Lid Opening Determined By Size Of Pumps And Shall Be Off Set To Be Over Ladder And Lid To Open Away From Control Box. END VIEW FRONT VIEW CONTROL PANEL N. T. S. No 1. The Centro/ Panel is To Face (Open To) The Lift Station Hatch 2. Size Of Cabinet To Be Larger For Stations With bumps Larger Phan 20 Hp. J. Alarm Working Lights To Use 60 To 100 Watt, 110 VAC Bulbs. Fixtures & The Connection To Control Box To Be Totally Weteeproof. flixtwvs To Novo Integral Guard Or Shield For ProteCtlon- 4. A Sgw m 0 Transfer Switch Shall Be Provided. W (Float Heads) PVC (Motor Heads) 'VC To Meter Pit :oncrete Pad semen t Meter Radio , • f foot Mounting Pole Minimum 6" Open Space O.S.H.A. Approved Non - Corrosive Ladder, Mounted To M.H. With Non - Corrosive Materials. D. ►ct Switch Stainless Steel Or Aluminum Unistrut — 100 Amp. Transfer Switch Stainless Steel Note: Or 3' Aluminum All Electrical Connections From Bock To The Channel. Pone/ Shall Be Made Into The Bottom Of The Panel. See Constant Speed Or Variable Speed Electrical Schematic Sheets For Additional Informations. TYPICAL UNDERGROUND SERVICE ON THE BACK OF PANEL N. T. S 6" D. 1. M. J. Force Main 4" PVC, SDR -21 Air Duct With Screen. PLAN VIEW - LIFT STATION SCALE. 314" — 1'-0' — Sheet Meta/ Or Laminated Fiber Concrete Form Adequote /y Braced In Field And Stripped Out Before Installing Pipe, Except In Masonry Where Sleeve Shall Be 3116" Steel And Shall Be Installed With Masonry. a. Inside Woll • a a Service Pipe Stainless Steel Bolts a • 4 d � �- Modular Mechanical Type Seal Of Interlocking Synthetic Rubber Links. TYPE C PIPE SL EEVE N. T.S. Note: I. Walls Shall Be Core Drilled Where Shown And Elsewhere /f Approved By The Engineer. 2. Concrete Shall Be Worked In And Vibrated To Eliminate Al/ Voids In Concrete - if Voids Do Remain, F,ll With Grout Before Installing Pipe And Rubber Seas. Plug Valve I I 5 Pipe 0 Minimu '� • ' .' ICIo• 3 Pipe p Minimu I I • Type "C" `- Wall Sleeve I Precast Pit Acceptable On Submittal j I V- Poured Concrete With One Layer Of I I (Min.) Water Proofing. Transition Fitting And Red Note• Required To Change From Asphalt Drive, 10' -0" Wide Shall Be Furnished D -L To 8" Pvc Force I From Nearest Street Surface To Concrete Pad Outside Of Station. And Valve Vault. - Valve Pit Size To Be Determined By The Area Needed To Put In The Required Components As Specified. Cm Will, U_ W U 9U 30- W s e� W W z i W O Z r-- O V w .r M A v m rn a vo M a1 Supported Pipe Or Valve. Z 1" Threaded Steel Ro Weld 318" Thick X 3" Wide Steel Plate Rolled To Fit Pipe Radius. ,Q Y To Rolled Plate. �... Hex. Nut & Lock Nu Nut LLJ V (Loose) 2" Standard Steel Pipe i (Length As Required) Threaded Pipe Cap Drilled To Accommodate Steel Rod. 6" Sq. X 318" Thick Steel Plate Weld 1 To Pipe Or Threaded Pipe Flange. LJ .' . •. •. Z 1" Grout. Q 2 _ 1/2" j Expansion Bolts. a ADJUSTABLE PIPE SUPPORT Z Z N. T. S. 0 Note: �.�. Pipe Supports Shall Be Spaced Not Q More Than 12' -0" On Center. Support j Piping Near Vo/ves, Flowmeters, Each Side Of Q And Couplings. ( LL J .J V SHEET N0. 15 28 SHEETS [_OF aeNO. 18465.