Loading...
HomeMy WebLinkAbout05070160-Site PlanCorrnet Prepared Dote: 07/13/05: By. AMA Proposed BOJM(8): INVENTOEY 20' fO' i D - sundog uae (e~ / ....... £~t Une Note: Sanitary Sewer Top of Casting Informoti~ Upstream Manhole, TC=912.70 Downstream Manhole, TC=914.20 per plan. Note: 1he garage finished floor elevation is 2.2' ~ove the curb at the drive, per pan. Ground Cqver Celoulotions: Drive = 1,297SEt _"-%. Public Walk =170 S~+ Private Walk =203 SF'~ Hydrosueding =4,991 SF+ =501 Sy+, [rom esidance. Note: This drawing s based on construction plans er record ~owings, and is not based upon o fidd survey, 1he Schneider Corporation dons not warrant the occorocy or sufficiency of this information. Contractors should verify existing conditions prier to any construction. Any disereponcy found on this drawing should be reported to The 5chnetder Corporation L, nrnediotel~, failing to do so results in the contractors assumption of all liability, Lot # 247 Assumed Noi~ Scale: 1' = Note: 1be b~ment elevation, depicted hereon, has been determined and based upon the pad credos and/or contonrs tcke~ Eom the construction plans for this subdidslon. Unless stated, no tnfefrnotion ooout fluctuoBu9 water tables, soil conditions, o~ soil t~e~ has bean provided or stated ~ s~td pl~e, It la recommannded that the basement finished floor elevations be et leo~t two feet (2') above the eermnl pool elewtion of any odjo~ln9 bodies of water, unless a study of facts reveals othmwlse, If doric the excsvatisa process any ~rmmd eater is witnessed, ho Sdmsh~r Corporoti~ shonld be noUfled,immediotely. Ihs besemsut devotion should be r~ised two feet (2) above the 9rsund water, and construction techniques should be i~corporoted to o~evicte I~ture problems. Detail of G-sued/Strum Water floe pattern indtvid~nl lots. Note: Builder m aqsure positive drainage away from structure(s). Note: Sump pump(s) to be pl~ced by builder as needed, distance of ten feet (10') between the sanitary sewer and water llne laterals. TC~914,20 PER PLAN 50. 00' Sidewalk to be ~nced ' i 1 fi.om property tee, 4' fi.om bock of curb. per Dion. FLOOD HAZARD STATEMENT CERTIFICATION so o3 BLOCK "P" COMMON AREA D.E. ~ L.E. .' / ~UI~ Note: P~ ~d z~in9 ~d~ce 26.1.1: ~e ~//lllllllfllllitt~ ' ~ reeld~ti~ district I~lts h~t to tw~t~flve feet (25'),  ~owev~ o dw~l~g moy be in~s~ · helot to ~, [ ~i~fi. feet (55') pro~d~ ~e ~,~d r~ ~rds f~t (1') ~e s~cture exce~ ~e f~s[ tw~t~fl~ feet (2~') Flood Hazard Statement: The accuracy of any flood hazard data shown on this repod map s~le uncertainly and to any other unceAaln[y in location or elevation on the referenced flood Jnsuran~ ra[e maP. ALL of ~e within desoribec rand DOES NOT lie within that special flood hazard zone AE as said land plots by scale on flood insurance ra[e map g180081 0205 F for the City of Carmel. indiana dated Februa~ 19. 2003. DA~ ~A~ R~N~ ~NRMA~ ~ ~PT ~ P~T ~ 8Y ~ST~.