HomeMy WebLinkAbout05070160-Site PlanCorrnet
Prepared Dote: 07/13/05: By. AMA
Proposed BOJM(8): INVENTOEY
20'
fO'
i
D
- sundog uae (e~ /
....... £~t Une
Note: Sanitary Sewer
Top of Casting Informoti~
Upstream Manhole, TC=912.70
Downstream Manhole, TC=914.20
per plan.
Note: 1he garage finished floor elevation
is 2.2' ~ove the curb at the drive, per pan.
Ground Cqver Celoulotions:
Drive = 1,297SEt _"-%.
Public Walk =170 S~+
Private Walk =203 SF'~
Hydrosueding =4,991 SF+
=501 Sy+, [rom
esidance.
Note:
This drawing s based on construction plans er record ~owings,
and is not based upon o fidd survey, 1he Schneider Corporation
dons not warrant the occorocy or sufficiency of this information.
Contractors should verify existing conditions prier to any
construction. Any disereponcy found on this drawing should be
reported to The 5chnetder Corporation L, nrnediotel~, failing to do
so results in the contractors assumption of all liability,
Lot # 247
Assumed Noi~
Scale: 1' =
Note: 1be b~ment elevation, depicted hereon, has been
determined and based upon the pad credos and/or contonrs tcke~
Eom the construction plans for this subdidslon. Unless stated, no
tnfefrnotion ooout fluctuoBu9 water tables, soil conditions, o~ soil
t~e~ has bean provided or stated ~ s~td pl~e, It la recommannded
that the basement finished floor elevations be et leo~t two feet (2')
above the eermnl pool elewtion of any odjo~ln9 bodies of water,
unless a study of facts reveals othmwlse, If doric the excsvatisa
process any ~rmmd eater is witnessed, ho Sdmsh~r Corporoti~
shonld be noUfled,immediotely. Ihs besemsut devotion should be
r~ised two feet (2) above the 9rsund water, and
construction techniques should be i~corporoted to o~evicte I~ture
problems.
Detail of G-sued/Strum
Water floe pattern
indtvid~nl lots.
Note: Builder m aqsure positive
drainage away from structure(s).
Note: Sump pump(s) to be
pl~ced by builder as needed,
distance of ten feet (10') between the
sanitary sewer and water llne laterals.
TC~914,20
PER PLAN
50. 00'
Sidewalk to be ~nced
' i
1 fi.om property tee,
4' fi.om bock of curb.
per Dion.
FLOOD HAZARD STATEMENT
CERTIFICATION
so o3
BLOCK "P"
COMMON AREA
D.E. ~ L.E.
.' /
~UI~ Note: P~ ~d z~in9 ~d~ce 26.1.1: ~e
~//lllllllfllllitt~ ' ~ reeld~ti~ district I~lts h~t to tw~t~flve feet (25'),
~owev~ o dw~l~g moy be in~s~ · helot to
~, [ ~i~fi. feet (55') pro~d~ ~e ~,~d r~ ~rds
f~t (1') ~e s~cture exce~ ~e f~s[ tw~t~fl~ feet
(2~')
Flood Hazard Statement: The accuracy of any flood hazard data shown on this repod
map s~le uncertainly and to any other unceAaln[y in location or elevation on the referenced flood
Jnsuran~ ra[e maP. ALL of ~e within desoribec rand DOES NOT lie within that special flood hazard
zone AE as said land plots by scale on flood insurance ra[e map g180081 0205 F for the City of
Carmel. indiana dated Februa~ 19. 2003.
DA~
~A~ R~N~ ~NRMA~ ~ ~PT ~ P~T ~ 8Y ~ST~.