HomeMy WebLinkAbout02361.pdf BICKFORD OF CARMEL, IN 12/12/2012 TERMITE CONTROL 02361 - 1 SECTION 02361 - TERMITE CONTROL PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Soil treatment with termiticide as required by 2006 International Residential Code, Section R320.1.1. B. Related Sections: 1. Division 6 Section "Rough Carpentry" for wood preservative treatment by pressure process. 2. Division 7 Section "Sheet Metal Flashing and Trim" for custom-fabricated, metal termite shields. 1.3 SUBMITTALS A. Product Data: For each type of termite control product. 1. Include the EPA-Registered Label for termiticide products. B. Product Certificates: For termite control products, from manufacturer. C. Soil Treatment Application Report: After application of termiticide is completed, submit report for Owner's records and include the following: 1. Date and time of application. 2. Moisture content of soil before application. 3. Termiticide brand name and manufacturer. 4. Quantity of undiluted termiticide used. 5. Dilutions, methods, volumes used, and rates of application. 6. Areas of application. 7. Water source for application. D. Warranties: Sample of special warranties. 1.4 QUALITY ASSURANCE A. Regulatory Requirements: Formulate and apply termiticides and termiticide devices according to the EPA-Registered Label. BICKFORD OF CARMEL, IN 12/12/2012 TERMITE CONTROL 02361 - 2 B. Source Limitations: Obtain termite control products from single source from single manufacturer. C. Preinstallation Conference: Conduct conference at Project site. 1.5 PROJECT CONDITIONS A. Environmental Limitations: To ensure penetration, do not treat soil that is water saturated or frozen. Do not treat soil while precipitation is occurring. Comply with requirements of the EPA- Registered Label and requirements of authorities having jurisdiction. B. Coordinate soil treatment application with excavating, filling, grading, and concreting operations. Treat soil under footings, grade beams, and ground-supported slabs before construction. 1.6 WARRANTY A. Soil Treatment Special Warranty: Manufacturer's standard form, signed by Applicator and Contractor, certifying that termite control work, consisting of applied soil termiticide treatment, will prevent infestation of subterranean termites. If subterranean termite activity or damage is discovered during warranty period, re-treat soil and repair or replace damage caused by termite infestation. 1. Warranty Period: Five years from date of Substantial Completion. PART 2 - PRODUCTS 2.1 SOIL TREATMENT A. Termiticide: Provide an EPA-Registered termiticide, complying with requirements of authorities having jurisdiction, in an aqueous solution formulated to prevent termite infestation. Provide quantity required for application at the label volume and rate for the maximum termiticide concentration allowed for each specific use, according to product's EPA-Registered Label. 1. Service Life of Treatment: Soil treatment termiticide that is effective for not less than five years against infestation of subterranean termites. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions, with Applicator present, for compliance with requirements for moisture content of soil per termiticide label requirements, interfaces with earthwork, slab and foundation work, landscaping, utility installation, and other conditions affecting performance of termite control. B. Proceed with application only after unsatisfactory conditions have been corrected. 3.2 PREPARATION BICKFORD OF CARMEL, IN 12/12/2012 TERMITE CONTROL 02361 - 3 A. General: Comply with the most stringent requirements of authorities having jurisdiction and with manufacturer's written instructions for preparation before beginning application of termite control treatment. Remove all extraneous sources of wood cellulose and other edible materials such as wood debris, tree stumps and roots, stakes, formwork, and construction waste wood from soil within and around foundations. B. Soil Treatment Preparation: Remove foreign matter and impermeable soil materials that could decrease treatment effectiveness on areas to be treated. Loosen, rake, and level soil to be treated except previously compacted areas under slabs and footings. Termiticides may be applied before placing compacted fill under slabs if recommended in writing by termiticide manufacturer. 1. Fit filling hose connected to water source at the site with a backflow preventer, complying with requirements of authorities having jurisdiction. 3.3 APPLICATION, GENERAL A. General: Comply with the most stringent requirements of authorities having jurisdiction and with manufacturer's EPA-Registered Label for products. 3.4 APPLYING SOIL TREATMENT A. Application: Mix soil treatment termiticide solution to a uniform consistency. Provide quantity required for application at the label volume and rate for the maximum specified concentration of termiticide, according to manufacturer's EPA-Registered Label, to the following so that a continuous horizontal and vertical termiticidal barrier or treated zone is established around and under building construction. Distribute treatment evenly. 1. Slabs-on-Grade and Basement Slabs: Under ground-supported slab construction, including footings, building slabs, and attached slabs as an overall treatment. Treat soil materials before concrete footings and slabs are placed. 2. Foundations: Adjacent soil, including soil along the entire inside perimeter of foundation walls; along both sides of interior partition walls; around plumbing pipes and electric conduit penetrating the slab; around interior column footers, piers, and chimney bases; and along the entire outside perimeter, from grade to bottom of footing. Avoid soil washout around footings. 3. Penetrations: At expansion joints, control joints, and areas where slabs will be penetrated. B. Avoid disturbance of treated soil after application. Keep off treated areas until completely dry. C. Protect termiticide solution, dispersed in treated soils and fills, from being diluted until ground- supported slabs are installed. Use waterproof barrier according to EPA-Registered Label instructions. D. Post warning signs in areas of application. E. Reapply soil treatment solution to areas disturbed by subsequent excavation, grading, landscaping, or other construction activities following application. END OF SECTION 02361