HomeMy WebLinkAbout15453.pdf BICKFORD OF CARMEL, IN 12/12/2012 PLUMBING PUMPS 15453-1 SECTION 15453 PLUMBING PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work of this section. 1.2 CODES AND STANDARDS A. UL and NEMA Compliance: Provide electric motors and components which are listed and labeled by Underwriters Laboratories and comply with NEMA standards. 1.3 SUBMITTALS A. Product Data Submit manufacturer's pump specifications, installation and start-up instructions, and current accurate pump characteristics performance curves with selection points clearly indicated. B. Shop Drawings Wiring Diagrams - Submit manufacturer’s wiring diagrams for review by the Engineer, upon review furnish copies of the reviewed submittal to the electrical contractor for coordination with their work. C. Operating and Maintenance Manuals Submit Operating and Maintenance Manuals in accordance with Specification Section 15010 containing, but not limited too, all information required therein. D. Training Provide services of manufacturer's technical representative for one 2-hour day to instruct Owner's personnel in operation and maintenance. PART 2 - PRODUCTS 2.1 IN-LINE RECIRCULATION PUMPS A. Provide in-line recirculation pumps where indicated, and of capacities as scheduled. All bronze construction. Horizontal, oil-lubricated, designed for 125 psi working pressure, 225 degrees F (107 degrees C) continuous water temperature, and specifically designed for quiet operation. 1. Body Provide bronze construction. 2. Shaft Provide steel, ground and polished, integral thrust collar. 3. Bearings BICKFORD OF CARMEL, IN 12/12/2012 PLUMBING PUMPS 15453-2 Provide two horizontal sleeve bearings designed to circulate oil. 4. Seal Provide mechanical seal, with carbon steel face rotating against ceramic seat. 5. Motor Provide non-overloading at any point on pump curve, open, drip-proof, sleeve bearings, quiet operating, rubber mounted construction, built-in thermal overload protection. 6. Coupling Provide self-aligning, flexible coupling. 7. Manufacturer Subject to compliance with requirements, provide inline recirculation pumps of one of the following: Paco Taco Thrush Bell & Gossett Armstrong PART 3 - EXECUTION 3.1 INSTALLATION OF PUMPS A. Install plumbing pumps where indicated, in accordance with manufacturer's published installation instructions, complying with recognized industry practices to ensure that plumbing pumps comply with requirements and serve intended purposes. Pumps shall be installed on and anchored to housekeeping pads via expansion anchor or similar means. Pad height shall be a minimum of 4” AFF, and pump base shall be grouted solid. B. Pumps shall be arranged and installed so as to provide access space around plumbing pumps for service as indicated, but in no case less than that recommended by manufacturer. Install electrical devices furnished by manufacturer but not specified to be factory-mounted. Furnish copy of manufacturer’s wiring diagrams and housekeeping pad layout drawings to Electrical and General Contractor for coordination with their work. END OF SECTION