AIR OUTLETS AND INLETS 15932-1
SECTION 15932
AIR OUTLETS AND INLETS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of Contract, including General and Supplementary
Conditions and Division-1 Specification sections, apply to work of this section.
1.2 QUALITY ASSURANCE
A. Comply with the following Codes and Standards
1. ADC Compliance: Test and rate air outlets and inlets in accordance with
requirements of ADC 1062.
1.3 COORDINATION
A. The Contractor shall coordinate his work with other mechanical, electrical and plumbing
systems and field measure, as required, prior to fabrication to facilitate a complete
installation.
1.4 SUBMITTALS
A. Product Data
Submit manufacturer's technical product data for air outlets and inlets including
performance data for each type of air outlet and inlet furnished, including throw and drop,
and noise criteria ratings.
B. Shop Drawings
Submit shop drawings for all air outlets and inlets intended for use on the project. The
Contractor shall coordinate rough opening sizes required with other Mechanical,
Electrical, Structural and to facilitate a complete installation. Shop Drawings should
include, but are not limited to, dimensioned drawings showing locations and rough
opening sizes required, elevations, attachment means etc.
C. Operating and Maintenance Manuals
Submit Operating and Maintenance Manuals in accordance with Specification Section
15010 containing, but not limited too, all information required therein.
1.5 VERIFICATION
A. Investigate the existing and proposed structural and finished conditions affecting the
system, and arrange the equipment accordingly, furnishing required fittings, offsets, and
accessories. Locate louvers/hoods to avoid interference with other mechanical, electrical
and plumbing systems. Consult with the Engineer before making any changes in the
event it becomes necessary to make changes in pipe locations due to the building
construction. Any such changes required shall be made without added cost to the
Owner.
PART 2 - PRODUCTS
2.1 LOUVERS
BICKFORD OF CARMEL, IN 12/12/2012
AIR OUTLETS AND INLETS 15932-2
A. Except as otherwise indicated, provide manufacturer's standard weatherproof louvers
where shown; of size, shape, capacity and type indicated; constructed of materials and
components as indicated, and as required for complete installation.
B. Manufacturer
Subject to compliance with requirements, provide louvers of one of the following:
Airline Products Co. Airolite Co.
American Warming & Ventilating, Inc. Arrow United Industries
Construction Specialties, Inc. Dowco Corp.
Industrial Louvers, Inc. Louvers & Dampers, Inc.
Penn Ventilator Co., Inc. Ruskin Mfg. Co.
Safe-Air Inc.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Install air outlets and inlets in accordance with manufacturer's written instructions and in
accordance with recognized industry practices.
1. Louvers
Louvers shall be provided by the Mechanical Contractor and installed by the General
Contractor.
END OF SECTION