HomeMy WebLinkAbout05080078-Site PlanCarmel, IN 4607~-
Prepared Date:" 07/21/05 ': 3y:, JKI
~ BUy~(S):~' HARIAN AND
DEBRA KAUFFMAN
Community R~tions:
Side Y~rd = 5 ,
Reer Yard = 20
ga,eS ; to' (8.,.)
9=
Note: The garage finished floor elevation
is 3,1' ~bo~ the curb et the drive, pa' plen.
TC=912.75
PER RECORD
Note:
This drawing is based on construction plans or record
and is not based upon a field survey. The
does not warrant the accuracy or sufficiency of this information.
Contractors should verify existing cenditiens prior to any
construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediotol),;, foiling to do
. - so results in the contractors assumption of oll liability,
R,H. of nd
S.F.+ in ~ Prop~l ~ Note.' The basement elevation, depicted hereon, has been
0~.o £~ting ~es ~ determined and based upon the pad grades end/or contours token
...---0<30.0----' C~t~r C.'~ from the constructon pans for ths subdvielon Unens stated no
** ~.? ~el.L. oc~tl~ information about ~luctuoUng watsr tablee, sol~ condtons o~ ~o[{
~"'~l'~ S~o~e'~:~e~/.Jnu~es typ~s has been provided or stated on said plans. It is recommend?,
_-__ v W~ter .?,~ee Uses that the h~ement ~ished floor elevetlens be at least two feet (2)
- - ~--- Su~- ,S~e ~ Lb. · spays the normal po(~ elevation of any ed.lo ning bedles of water
~ ~J~eS~aI~Y~.~Istorm) unlens e study of iacts revenls otherwise If d~rlng the exaavetinn
lB Ca~ Net (SBa'm) process any grouna water ~s w menson, me ;:~ne'~,~r ~orpora~; on
(50'E/~) End Sectl~ ($t~*"m) s~ou d be not fled lmmed ateiy. ~he b~sement elevat on should be
W~f~ R~7"~7 ~ta~ of C~cund/St~
Note: Fa' Carmel zoning ordinance 26,1.1: The
reeidenUei district limits height to twenty-five feet (25'),
however a dw~ing ,,may be incfoneed in height to
thirty-.flve feet (35) provided the side and rsur ~rds
ore increased an additional one foot (t') for ead~ one
foot (1') the structure exceeds the flint twenty-flys feet
(25') in height,
TC~Bt2.94
RECORD
DRAV~ING
Lot #
^~umed North
~ote: Bu)der to ensure Positive
drainage away from structure(s).
Note: Sump pump(s) to be
~oced by builder as needed.
~IL~ER IS CAUTIONED, CONSIRUC'nON OF
DRIVE PERt, ilTI1ED ONLY AFTER O~TNNING
APPROVAL ~(N 1HE CONTROLUNG
MUNIQPAUI7.
RO[J
Ground Cover ColculaUons:
Drive = 1.177SF:1:
Public Walk =593
Private Walk =209
H~dro=s~eding =4,732 SF+
Sod 593 SY:b from
Rear of residence,
Side.elk to be p~aced
1', from prope'ty line,
4 from bad( of curb,
per plan.
R.H. of indiana
Finished Roar Elevation Information
Pad Grade = 914-.8 per plan
Pad Grade + 0,7,=" Gordge FF[ (9t5,5)
FFE + 1.5 = :Resi~enti~ FFE(917:0~ ~:
O~age
Residential FFE - 9.0" - --= Basement FFE (908.0)
Note: Sanitary Sewer
Top of C~stlng Information
Upstream Manhole, TC=9t2.94
Downstream laonhole, TC=912.73
per record drawings.
Note: ~
The contractor is to maintain a minimum
distance of ten feet (10') between the
sanitary sewa' and water line laterals.
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report Is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
Insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard
zone AE as said land plots by scale on flood Insurance rate map #180081 0205 F for the City of
FLOOD HAZARD STATEMENT
CERllFICAllON
so o3