HomeMy WebLinkAboutA 1.02x(o WALL5 AT PERIMETER
OF GREAT ROOM
EXISTING NOME
�e
wa Ik- in
closet
3' -& 3/4"
�i_101I - !ti
T- 11 1/4"
DN.
Great Room
24' -8 1/2" x IIII
1 ■E�
s =
5'- X -0"
Laundry r
V -0 1 /2 "x 5' -8 1/2"
2/8 8'- 5' -3 1/211
2/S 211
-� 2/0
N
_1
-1 1/411
`V
_1' -1 5/811
I
N
\
_1 N
N
1 1/411
T-9 1/4"
11 3/4"
31
-T 1 /4 11
� C
m
Fireplace\
9 �l /
1
o r!i
2/8
Master 5ath
12'-31/2" x 13' -0"
-} 1/4 N
1 11 \
=
01-0
N
19' -�II
Master Bedroom
r 19' -I 1/2" x 13' -0"
cal
2/8
-1 1/4" 1 1/4" 2' -3 1/2'
Hallway
8' -0 5/8" 2'- 101121-511 - 11_011
2' Study
11 31 1 3 5/0" .4'— 0 1 %T " /
1 1' -011 2' --1 /811
Screen Porch
Fireplace _ 20'-0" x II' -0"
e'- 1 3/4"
9' -1 3 /4 11
8 II Q 11
4' -2 1/2" 22' -3 1/211
Main Level door rian (14(ol SQUARE FEET NEW CONSTRUCTION IST FLOOR)
Scale: I/4•• = 1'_0"
PRE - MANUFACTURED 12
ENGINEERED ROOF TRUSSES 12
1i
FIBERGLASS SHINGLES W/ 015 FELT PAPER
ON 1/16" OS$. SHEATHING W/ SPACERS HA
INSULATION STOP
1 1 / 2" MIN. CLEARANCE
MTL. DRIP,
GUTTER < DOWNSPOUT —1 111
LU
Lll �
IxlO FASCIA BD.
CELLULOUS INSUL. (R50)
I / 2 " EXT. PLYWOOD SOFFIT
W/ 2" CONT. VENT
2x4 LOOKOUT
Ix8 TRIM BD. 1/2" GYP. BD.
FLASH OVER HEAD TRIM (2) 2x TOP PLATES
SLOPE GUT 2x2
TRIM CAP 2x4 OR 2x6 STUDS AT 16 "O.C.
OVER Ixb
Ix CASING
HEAD FLASH WINDOW HEAD
FIXED TRANSOM WINDOW
SLOPE GUT 2x2
WINDOW SILL
N Ix CASING
WINDOW JAMB < SILL TO
BE CAULKED AS REQ.
FIBER CEMENT PANELS N 1/2" GYP. BD.
(Z -FLASH AT HORZ. JOINTS)
ON WEATHER BARRIER ON (2) 2x TOP PLATES
CONTINUOUS INSULATION ON DBL. HEADER
I/2" WOOD PANEL SHEATHING Ix CASING
Ix6 HEAD AND JAMB
TRIM SURROUND
FLASH AS REQ.
SINGLE HUNG WINDOW
- r
04
-1 Ix CASING
BATT INSUL. (R13 OR RI9)
SLOPE CUT 2x2 4" CONC. SLAB W/ 6x6 010A0 WWM
WINDOW SILL OR FIBER REINFORCING ON 6 MIL.
POLYETHELENE VAPOR BARRIER
WINDOW JAMB E SILL TO OVER 4" PEA GRAVEL FILL
BE CAULKED AS REQ.
FIBER CEMENT PANELS 2" RIGID INSUL. 2' -0" LONG
Z -FLASH AT HOR. JOINTS. HORIZONTALLY (R -I0)
SLOPE GUT 2x2
BASE TRIM GAP
(FLASH AS REQUIRED)
OVER IxIO
2x4 TREATED SILL PLATE
0o 0 8
FINISH GRADE =III= — III =IJ-JJ 1 =I I =J 1 =I
I I -i �) I F-1/I IQ" DIA. x 8" SIMPSON TITEN HD MG
CONTINUOUS INSULATION OVER (MECHANICALLY GALV.) ® 48" O.G.
WEATHER BARRIER Z u (SEE FND. NOTE "3)
ol D� CaC. (L fat. •
BEND 04 BARS 2' -0" EA. WAY
Ra .
4'-0" O.G.
15" POURED TRENCH FT'G. W/ (3) 05
I5 i, BARS CONTINUOUSLY (CHAIR UP
BARS 3" COVERAGE)
T'qr- Wall
r
5ca le: 1/2'' = 1' -011
N
n�
Ilr-
L
o
_I
nUn,
�lL
V
= I
N
1
ul
� r
�l
3
1
r
i
2/8 13' -5" x 13' -11"
7' -`"I" 1/211 31_311 31 =1
811 I
21_oil
House r—ast Elevation
Scale: 1/4'' = li -0"
I I
and Hooks
2/8
DN.
N
6�
1�
�1
N
W
►1
0
NEW DORMER AND STAIR
TO EX15TING GARAGE 2ND
FLOOR
o
Hot Tub
Rear Porch
14' -0" x 25' -(0"
8' -]O1I
EXISTING GA AGE
s
1_211
N
=
\
N
m
DN.
(�
N
(�
N
CV
N
N
\
m
vive
exterior design
15325 herriman blvd
noblesville, in 46060
p: 317- 773 -9933
f: 317- 773 -9944
www.viveexterior.com
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIE
DRAWING ARE OWNED BY AND THE PROPERTY OF VIVE EXTERIOR DESIGN, LLC
AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THF.
SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL
USED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE
WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF VIVE EXTERIOR DESIGN, LLC.
WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER
SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS
AND CONDITIONS ON THE JOB. THE DESIGNER MUST BE NOTIFIED OF ANY VARIATION FROM
THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. CONFIDENTIAL
WARNING: COPYWRITE VIVE EXTERIOR DESIGN REPRODUCTION HEREOF 15 A
CRIMINAL OFFENSE UNDER 18 U.S.C. SEC. 506. UNAUTHORIZED DISCLOSURE MAY CONSTITUTE
TRADE SECRET MISAPPROPRIATION IN VIOLATION OF I.C.24- 2 -31 -1 ET. SEC. AND OTHER LAWS.
THE IDEAS, ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE PATENTED OR
BE THE SUBJECT OF PENDING PATENT APPLICATION.
FIRST FLOOR PLAN FOR: �
COYLE RESIDENCE
741 1st AVENUE NE
CARMEN, IN 46032
drawn by: RMC sheet:
checked by: RMC
date: 03 -31 -12
v
vive
exterior design
D