Loading...
HomeMy WebLinkAboutGenerator Enclosure2013 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change without notice. S-1443y (5/13) Enclosures and tanks 250-1000 kW gensets Enclosure standard features 14-gauge steel construction (panels) Stainless steel hardware Zinc phosphate pretreatment, e-coat primer and super durable powder topcoat paint minimize corrosion and color fade Package listed to UL 2200 Designed to satisfy National Electrical Code installation requirements Fuel and electrical stub-up area within enclosure perimeter Fixed louvers Cambered roof prevents water accumulation Recessed, lockable doors in two sides Retainers hold doors open for easy access Enclosed exhaust silencer ensures safety and protects against rust Rain cap Exterior oil and coolant drains with interior valves for ease of service Rodent barriers on inlet Non-hydroscopic sound attenuating material Side mounted controls and circuit breakers Easy access lifting points for spreader bars Dual vibration isolation system (250-500 kW) Spring vibration isolation system (600-1000 kW) Enclosure mounts to lifting base or fuel tank (250-500 kW) Enclosure mounts to lifting base (600-1000 kW) Factory pre-assembled package Designed for outdoor use only Externally mounted emergency stop button for operator safety (optional on 250-500 kW) Horizontal air discharge to prevent leaf and snow accumulation (600-1000 kW) Options Three levels of sound attenuation Motorized louvers to protect from ice and snow accumulation (available on air inlet for all models and on air outlet on level II, 250-500 kW enclosures only) Horizontal air discharge, sound level 2 only (250-500 kW) Aluminum construction with roll-coated polymer paint Wind rated to 150 mph (aluminum enclosures) Neutral sandstone paint color (aluminum only) Factory mounted battery charger External 120 VAC service outlet Rain hoods for air inlet (250-500 kW) Lifting base in lieu of a sub-base tank (250-500 kW) - Pre-wired AC distribution package - 100 amp (250-500 kW) or 150 amp (600-1000 kW) main circuit breaker; connected to 120 VAC line- neutral and 208 or 240 VAC line-line, spare breaker positions and capacity for future upgrades (600- 1000 kW) - GFCI protected internal 120 VAC service receptacle - GFCI protected weather proof external 120 volt service receptacle - All factory installed AC powered features pre-wired into load center Interior lights – 120 volt (600-1000 kW) Rain hoods for air inlet (250-500 kW) Seismic isolators available (600-1000 kW) Page 30 of 73 . Our energy working for you.™ www.cumminspower.com 2013 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change without notice. S-1443y (5/13) Fuel tanks Standard sub-base tank features UL 142 Listed ULC-S601-07 Listed NFPA37 compliant Dual walled, steel construction Emergency tank and rupture basin vents Tank mounted mechanical fuel gauge Fuel supply and return tubes Top mounted leak detection float switch Low and high level fuel switches Mounting brackets for optional pump and control (250- 500 kW) Integral lifting points Basin drain Sub-base tank options Pre-wired fuel pump and control Fuel overfill alarm – internal or external Overflow and tank fill plugs Five gallon spill fill box – internal or external Fill pipe extender Local code approvals available 200-500 kW dual wall sub-base fuel tanks – usable operating hours Genset model (60 Hz) Gallons/ hour at full load 270 gallon tank 300 gallon tank 400 gallon tank 500 gallon tank 600 gallon tank 660 gallon tank 720 gallon tank 850 gallon tank 1470 gallon tank 1700 gallon tank 2100 gallon tank 2525 gallon tank 250 DQDAA 20 13 16 20 24 30 32 37 74 275 DQDAB 21 12 15 18 22 27 30 34 68 275 DQHAA 22 12 14 18 21 27 29 39 81 300 DQDAC 23 11 14 17 20 25 27 31 63 300 DQHAB 23 11 14 17 20 25 27 36 76 350 DFEG 24 11 13 16 19 24 26 35 73 104 400 DFEH 27 10 12 14 17 21 23 31 64 92 450 DFEJ 30 9 10 13 15 19 21 28 58 83 500 DFEK 34 8 9 11 14 17 18 25 51 73 Operating hours are measured at 60 Hz, standby rating. 600-1000 kW dual wall sub-base fuel tanks – usable operating hours Genset model Gallons/ hour at full load 200 gallon tank 660 gallon tank 1000 gallon tank 1500 gallon tank 2000 gallon tank 2400 gallon tank 3000* gallon tank 600 DQCA 42 4 14 23 35 47 57 72 600 DQPAA 45 4 15 22 33 44 53 67 600 DQPAB 50 4 13 20 30 40 48 60 750 DQCB 51 4 12 19 29 39 47 58 750 DQFAA 53 3 11 19 28 37 46 57 800 DQCC 53 3 11 18 28 37 45 57 800 DQFAB 56 3 11 17 26 35 43 53 900 DQFAC 64 3 9 15 23 31 38 47 1000 DQFAD 72 3 8 14 21 27 33 42 *3000 gallon tank offered as an accessory kit - Operating hours are measured at 60Hz, standby rating. - Up to 90% fill alarm to comply with NFPA30, operating capacity is reduced by 10%. Page 31 of 73 . Our energy working for you.™ www.cumminspower.com 2013 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change without notice. S-1443y (5/13) Enclosure package sound pressure levels @ 7 meters dB(A) Genset model Weather protective enclosure (F200, F203) QuietSite Level 1 sound attenuated enclosure (F201, F204) QuietSite Level 2 sound attenuated enclosure (F202, F205) 250 DQDAA 90 88 72 275 DQDAB 90 88 73 275 DQHAA 86 85 74 300 DFCB 86 84 71 300 DQDAC 90 88 73 300 DQHAB 89 88 76 350 DFCC 87 85 72 350 DFEG 86 85 72 400 DFCE 89 85 73 400 DFEH 87 85 73 450 DFEC 89 85 75 450 DFEJ 888574 500 DFED 90 86 76 500 DFEK 89 87 73 600 DFGB 85 78 74 600 DQCA 86 78 74 600 DQPAA 89 80.7 77.19 600 DQPAB 90 81.36 80.27 750 DFGE 87 80 75 750 DFHA 91 81 77 750 DQCB 87 79 74 750 DQFAA 89 79 75 800 DFHB 91 81 77 800 DQCC 87 79 74 800 DQFAB 897975 900 DFHC 93 83 78 900 DQFAC 89 80 76 1000 DFHD 90 80 76 1000 DQFAD 90 80 76 - All data is 60Hz, full load standby rating, steel enclosures only. - Data is a measured average of 8 positions. - Sound levels for aluminum enclosures are approximately 2 dB(A) higher than listed sound levels for steel enclosures. 250-1000 kW 250-1000 kW Weather protective QuietSite Level 2 Page 32 of 73 2013 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change without notice. S-1443y (5/13) Package dimensions of enclosure, exhaust system, and UL tank 250-500 kW Tank size (gal) Weather protective package length (in) QuietSite level I package length (in) QuietSite level 2 package length (in) Width (in) Height (in) Weather protective package weight (lbs) QuietSite level 1 package weight (lbs) QuietSite level 2 package weight (lbs) 300 188 188 222 82 104 5648 6073 6991 400 188 188 222 82 106 5833 6258 7176 500 188 188 222 82 108 5956 6381 7299 600 188 188 222 82 111 6116 6541 7459 660 188 188 222 82 113 6235 6660 7578 720 188 188 222 82 114 6174 6599 7517 850 188 188 222 82 118 6529 6954 7872 1470 200 200 200 82 128 7428 7853 8771 1700 234 234 234 82 128 7982 8407 9325 Lifting base 188 188 222 82 100 4335 4760 5678 600-1000 kW Tank size (gal) Weather Protective package length (in) QuietSite level I package length (in) QuietSite level 2 package length (in) Width (in) Height (in) Weather protective package weight (lbs) QuietSite level 1 package weight (lbs) QuietSite level 2 package weight (lbs) 200 260 303 315 98 129 10194 13074 14954 660 260 303 315 98 131 9586 12466 14346 1000 260 303 315 98 143 10117 12997 14877 1500 260 303 315 98 145 10677 13557 15437 2000 292 327 327 98 143 11959 14839 16719 2400 338 338 338 98 143 12961 15841 17721 - This weight does not include the generator set. Consult your local Cummins Power Generation distributor or the appropriate generator specification sheet. - Width is 86” lifting eye to lifting eye (250-500 kW), 102” lifting eye to lifting eye (600-1000 kW). - Height - Florida, Michigan, and Suffolk add 4” (250-500 kW) or 2” (600-1000 kW) for bottom space. - Maximum length emergency vent removed. CSA - The generator set is CSA certified to product class 4215-01. UL - The generator set is available Listed to UL 2200, Stationary Engine Generator Assemblies. The PowerCommand control is Listed to UL 508 - Category NITW7 for U.S. and Canadian usage. See your distributor for more information Americas 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone: 763 574-5000 Fax: 763 574-5298 Page 33 of 73 Sh e e t 1 o f 7 Pa r t N a m e : A 0 3 4 J 5 9 3 R e v i s i o n : C Dr a w i n g N a m e : A 0 3 4 J 5 9 4 R e v i s i o n : C Page 34 of 73 Sh e e t 2 o f 7 Pa r t N a m e : A 0 3 4 J 5 9 3 R e v i s i o n : C Dr a w i n g N a m e : A 0 3 4 J 5 9 4 R e v i s i o n : C Page 35 of 73 Sh e e t 1 o f 3 Pa r t N a m e : A 0 3 5 F 9 5 1 R e v i s i o n : A Dr a w i n g N a m e : A 0 3 5 F 9 5 2 R e v i s i o n : A Page 36 of 73