HomeMy WebLinkAboutGenerator Enclosure2013 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins
Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change
without notice.
S-1443y (5/13)
Enclosures and tanks
250-1000 kW
gensets
Enclosure standard features
14-gauge steel construction (panels)
Stainless steel hardware
Zinc phosphate pretreatment, e-coat primer and super
durable powder topcoat paint minimize corrosion and
color fade
Package listed to UL 2200
Designed to satisfy National Electrical Code installation
requirements
Fuel and electrical stub-up area within enclosure
perimeter
Fixed louvers
Cambered roof prevents water accumulation
Recessed, lockable doors in two sides
Retainers hold doors open for easy access
Enclosed exhaust silencer ensures safety and protects
against rust
Rain cap
Exterior oil and coolant drains with interior valves for
ease of service
Rodent barriers on inlet
Non-hydroscopic sound attenuating material
Side mounted controls and circuit breakers
Easy access lifting points for spreader bars
Dual vibration isolation system (250-500 kW)
Spring vibration isolation system (600-1000 kW)
Enclosure mounts to lifting base or fuel tank
(250-500 kW)
Enclosure mounts to lifting base (600-1000 kW)
Factory pre-assembled package
Designed for outdoor use only
Externally mounted emergency stop button for
operator safety (optional on 250-500 kW)
Horizontal air discharge to prevent leaf and snow
accumulation (600-1000 kW)
Options
Three levels of sound attenuation
Motorized louvers to protect from ice and snow
accumulation (available on air inlet for all models and
on air outlet on level II, 250-500 kW enclosures only)
Horizontal air discharge, sound level 2 only
(250-500 kW)
Aluminum construction with roll-coated polymer paint
Wind rated to 150 mph (aluminum enclosures)
Neutral sandstone paint color (aluminum only)
Factory mounted battery charger
External 120 VAC service outlet
Rain hoods for air inlet (250-500 kW)
Lifting base in lieu of a sub-base tank (250-500 kW)
- Pre-wired AC distribution package
- 100 amp (250-500 kW) or 150 amp (600-1000 kW)
main circuit breaker; connected to 120 VAC line-
neutral and 208 or 240 VAC line-line, spare breaker
positions and capacity for future upgrades (600-
1000 kW)
- GFCI protected internal 120 VAC service receptacle
- GFCI protected weather proof external 120 volt
service receptacle
- All factory installed AC powered features pre-wired
into load center
Interior lights – 120 volt (600-1000 kW)
Rain hoods for air inlet (250-500 kW)
Seismic isolators available (600-1000 kW)
Page 30 of 73
.
Our energy working for you.™
www.cumminspower.com
2013 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins
Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change
without notice.
S-1443y (5/13)
Fuel tanks
Standard sub-base tank features
UL 142 Listed
ULC-S601-07 Listed
NFPA37 compliant
Dual walled, steel construction
Emergency tank and rupture basin vents
Tank mounted mechanical fuel gauge
Fuel supply and return tubes
Top mounted leak detection float switch
Low and high level fuel switches
Mounting brackets for optional pump and control (250-
500 kW)
Integral lifting points
Basin drain
Sub-base tank options
Pre-wired fuel pump and control
Fuel overfill alarm – internal or external
Overflow and tank fill plugs
Five gallon spill fill box – internal or external
Fill pipe extender
Local code approvals available
200-500 kW dual wall sub-base fuel tanks – usable operating hours
Genset
model
(60 Hz)
Gallons/
hour
at full
load
270
gallon
tank
300
gallon
tank
400
gallon
tank
500
gallon
tank
600
gallon
tank
660
gallon
tank
720
gallon
tank
850
gallon
tank
1470
gallon
tank
1700
gallon
tank
2100
gallon
tank
2525
gallon
tank
250 DQDAA 20 13 16 20 24 30 32 37 74
275 DQDAB 21 12 15 18 22 27 30 34 68
275 DQHAA 22 12 14 18 21 27 29 39 81
300 DQDAC 23 11 14 17 20 25 27 31 63
300 DQHAB 23 11 14 17 20 25 27 36 76
350 DFEG 24 11 13 16 19 24 26 35 73 104
400 DFEH 27 10 12 14 17 21 23 31 64 92
450 DFEJ 30 9 10 13 15 19 21 28 58 83
500 DFEK 34 8 9 11 14 17 18 25 51 73
Operating hours are measured at 60 Hz, standby rating.
600-1000 kW dual wall sub-base fuel tanks – usable operating hours
Genset
model
Gallons/
hour at
full load
200
gallon
tank
660
gallon
tank
1000
gallon
tank
1500
gallon
tank
2000
gallon
tank
2400
gallon
tank
3000*
gallon
tank
600 DQCA 42 4 14 23 35 47 57 72
600 DQPAA 45 4 15 22 33 44 53 67
600 DQPAB 50 4 13 20 30 40 48 60
750 DQCB 51 4 12 19 29 39 47 58
750 DQFAA 53 3 11 19 28 37 46 57
800 DQCC 53 3 11 18 28 37 45 57
800 DQFAB 56 3 11 17 26 35 43 53
900 DQFAC 64 3 9 15 23 31 38 47
1000 DQFAD 72 3 8 14 21 27 33 42
*3000 gallon tank offered as an accessory kit
- Operating hours are measured at 60Hz, standby rating.
- Up to 90% fill alarm to comply with NFPA30, operating capacity is reduced by 10%.
Page 31 of 73
.
Our energy working for you.™
www.cumminspower.com
2013 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins
Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change
without notice.
S-1443y (5/13)
Enclosure package sound pressure levels @ 7 meters dB(A)
Genset model
Weather protective
enclosure
(F200, F203)
QuietSite Level 1 sound
attenuated enclosure
(F201, F204)
QuietSite Level 2 sound
attenuated enclosure
(F202, F205)
250 DQDAA 90 88 72
275 DQDAB 90 88 73
275 DQHAA 86 85 74
300 DFCB 86 84 71
300 DQDAC 90 88 73
300 DQHAB 89 88 76
350 DFCC 87 85 72
350 DFEG 86 85 72
400 DFCE 89 85 73
400 DFEH 87 85 73
450 DFEC 89 85 75
450 DFEJ 888574
500 DFED 90 86 76
500 DFEK 89 87 73
600 DFGB 85 78 74
600 DQCA 86 78 74
600 DQPAA 89 80.7 77.19
600 DQPAB 90 81.36 80.27
750 DFGE 87 80 75
750 DFHA 91 81 77
750 DQCB 87 79 74
750 DQFAA 89 79 75
800 DFHB 91 81 77
800 DQCC 87 79 74
800 DQFAB 897975
900 DFHC 93 83 78
900 DQFAC 89 80 76
1000 DFHD 90 80 76
1000 DQFAD 90 80 76
- All data is 60Hz, full load standby rating, steel enclosures only.
- Data is a measured average of 8 positions.
- Sound levels for aluminum enclosures are approximately 2 dB(A) higher than listed sound levels for steel enclosures.
250-1000 kW 250-1000 kW
Weather protective QuietSite Level 2
Page 32 of 73
2013 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins
Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Specifications are subject to change
without notice.
S-1443y (5/13)
Package dimensions of enclosure, exhaust system, and UL tank
250-500 kW
Tank size
(gal)
Weather
protective
package
length (in)
QuietSite
level I
package
length (in)
QuietSite
level 2
package
length (in)
Width
(in)
Height
(in)
Weather
protective
package
weight (lbs)
QuietSite
level 1
package
weight (lbs)
QuietSite
level 2
package
weight (lbs)
300 188 188 222 82 104 5648 6073 6991
400 188 188 222 82 106 5833 6258 7176
500 188 188 222 82 108 5956 6381 7299
600 188 188 222 82 111 6116 6541 7459
660 188 188 222 82 113 6235 6660 7578
720 188 188 222 82 114 6174 6599 7517
850 188 188 222 82 118 6529 6954 7872
1470 200 200 200 82 128 7428 7853 8771
1700 234 234 234 82 128 7982 8407 9325
Lifting base 188 188 222 82 100 4335 4760 5678
600-1000 kW
Tank size
(gal)
Weather
Protective
package
length (in)
QuietSite
level I
package
length (in)
QuietSite
level 2
package
length (in)
Width
(in)
Height
(in)
Weather
protective
package
weight (lbs)
QuietSite
level 1
package
weight (lbs)
QuietSite
level 2
package
weight (lbs)
200 260 303 315 98 129 10194 13074 14954
660 260 303 315 98 131 9586 12466 14346
1000 260 303 315 98 143 10117 12997 14877
1500 260 303 315 98 145 10677 13557 15437
2000 292 327 327 98 143 11959 14839 16719
2400 338 338 338 98 143 12961 15841 17721
- This weight does not include the generator set. Consult your local Cummins Power Generation distributor or the appropriate
generator specification sheet.
- Width is 86” lifting eye to lifting eye (250-500 kW), 102” lifting eye to lifting eye (600-1000 kW).
- Height - Florida, Michigan, and Suffolk add 4” (250-500 kW) or 2” (600-1000 kW) for bottom space.
- Maximum length emergency vent removed.
CSA - The generator set is CSA certified to product class 4215-01.
UL - The generator set is available Listed to UL 2200, Stationary Engine Generator Assemblies. The
PowerCommand control is Listed to UL 508 - Category NITW7 for U.S. and Canadian usage.
See your distributor for more information
Americas
1400 73rd Avenue N.E.
Minneapolis, MN 55432 USA
Phone: 763 574-5000
Fax: 763 574-5298
Page 33 of 73
Sh
e
e
t
1
o
f
7
Pa
r
t
N
a
m
e
:
A
0
3
4
J
5
9
3
R
e
v
i
s
i
o
n
:
C
Dr
a
w
i
n
g
N
a
m
e
:
A
0
3
4
J
5
9
4
R
e
v
i
s
i
o
n
:
C
Page 34 of 73
Sh
e
e
t
2
o
f
7
Pa
r
t
N
a
m
e
:
A
0
3
4
J
5
9
3
R
e
v
i
s
i
o
n
:
C
Dr
a
w
i
n
g
N
a
m
e
:
A
0
3
4
J
5
9
4
R
e
v
i
s
i
o
n
:
C
Page 35 of 73
Sh
e
e
t
1
o
f
3
Pa
r
t
N
a
m
e
:
A
0
3
5
F
9
5
1
R
e
v
i
s
i
o
n
:
A
Dr
a
w
i
n
g
N
a
m
e
:
A
0
3
5
F
9
5
2
R
e
v
i
s
i
o
n
:
A
Page 36 of 73