HomeMy WebLinkAboutCARMEL E300.pdfSEE MECHANICAL/PLUMBING DRAWINGS FOR EQUIPMENT RATINGS AND SIZES. PERIODIC SITE OBSERVATION BY THE ENGINEER IS SOLELY FOR THE PURPOSE OF DETERMINING IF THE WORK OF THE CONTRACTOR IS PROCEEDING IN ACCORDANCE WITH CONTRACT DOCUMENTS. THIS LIMITED SITE OBSERVATION SHOULD NOT BE CONSTRUED AS EXHAUSTIVE OR CONTINUOUS TO CHECK THE QUALITY OR QUANTITY OF THE WORK, BUT RATHER PERIODIC IN AN EFFORT TO GUARD THE OWNER AGAINST DEFECTS OR DEFICIENCIES IN THE WORK OF THE CONTRACTOR. THE INFORMATION CONTAINED ON THE ELECTRICAL DRAWINGS IS IN ITSELF INCOMPLETE AND VOID UNLESS USED IN CONJUNCTION WITH ALL OTHER DISCIPLINE DRAWINGS, THE SPECIFICATIONS, TRADE PRACTICES, OR APPLICABLE STANDARDS, CODES, ETC., AND SHALL BE CONSIDERED THE CONTRACT DOCUMENTS AND WITH ALL THE IN BY REFERENCE, WHICH THE CONTRACTOR CERTIFIES KNOWLEDGE OF BY SIGNING THE CONTRACT. CONTRACTOR IS TO ASSUME FULL RESPONSIBILITY, UNRELIEVED BY REVIEW OF SHOP DRAWINGS OR PERIODIC OBSERVATION OF CONSTRUCTION, FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS, FOR DIMENSIONS TO BE CONFIRMED AND CORRELATED ON THE JOB SITE AND BETWEEN INDIVIDUAL DRAWINGS OR SETS OF DRAWINGS FOR FABRICATION PROCESSES AND CONSTRUCTION TECHNIQUES (INCLUDING EXCAVATION, SHORING, SCAFFOLDING, BRACING, ERECTION, FORMWORK, ETC.), FOR COORDINATION OF THE VARIOUS TRADES, AND FOR SAFE CONDITIONS ON THE JOB SITE. VARIATIONS IN FIELD CONDITIONS RELATIVE TO THE CONTRACT DOCUMENTS SHALL BE REPORTED TO THE ENGINEER AS SOON AS THEY ARE FOUND. WORK SHALL NOT PROGRESS UNTIL WRITTEN PERMISSION FROM THE ENGINEER IS OBTAINED. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE APPROXIMATE. ALL LOCATIONS SHALL BE FIELD VERIFIED. THESE DRAWINGS SHALL NOT BE SCALED TO OBTAIN DIMENSIONS. IF THE DIMENSIONS CANNOT BE DETERMINED BY THE INFORMATION GIVEN, CONTRACTOR SHALL CONTACT ENGINEER FOR REQUIRED INFORMATION. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE- LATEST EDITION ADOPTED BY INDIANA, THE INDIANA ELECTRICAL CODE AMENDMENTS, LOCAL/ MUNICIPAL CODES, AND THE AUTHORITY HAVING JURISDICTION. ALL CONNECTIONS TO EQUIPMENT SUBJECT TO MOVEMENT OR VIBRATION SHALL BE LIQUID TIGHT FLEXIBLE METAL CONDUIT, NOT LESS THAN 12" IN LENGTH, NOR GREATER THAN 36" IN LENGTH. ALL CONDUIT PENETRATIONS SHALL BE SEALED WITH APPROPRIATE CONDUIT SEALING MATERIAL. ELECTRICAL GENERAL NOTES: HOMERUN CIRCUITS ARE NOTATED BESIDE RECEPTACLES AND EQUIPMENT. ALL HOMERUNS SHALL BE FED BACK TO PANEL A UNLESS OTHERWISE NOTED. MAJOR FEEDERS FROM THE SWITCHBOARD TO PANELBOARDS, TRANSFORMERS, MOTORS AND OTHER LARGE EQUIPMENT ARE NOT SHOWN ON THE PLAN DRAWINGS. THESE FEEDERS ARE INCLUDED WITHIN THE SCOPE OF THE ELECTRICAL WORK, AND SHALL BE INSTALLED AS INDICATED ON THE ONE LINE DIAGRAM DRAWING. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF BUILDING EXPANSION JOINTS. ALL CONDUITS CROSSING EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION FITTINGS, UNLESS THE CONDUIT IS BELOW SLAB IN THE COMPACTED GRANULAR FILL. EXPANSION FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC, AND MANUFACTURER'S WRITTEN RECOMMENDATIONS. INDOOR CONTROL EQUIPMENT ENCLOSURES SHALL BE NEMA 1 RATED U.O.N. ALL EXTERIOR ENCLOSURES SHALL BE NEMA 3R U.O.N. ALL VOICE/DATA CABLING, SECURITY CONTROL SYSTEM AND ALL OTHER LOW- VOLTAGE SIGNAL CABLING SHALL BE INSTALLED BY OTHERS. PENETRATIONS THROUGH FIRE RATED WALLS BY DIVISION 26 CONTRACTOR SHALL BE SEALED WITH APPROPRIATE FIRE PROOFING MATERIAL TO RESTORE FIRE RATING. SEE ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. ALL POWER AND LIGHTING CIRCUITS SHALL BE MINIMUM (2)#12, AND (1)#12 G, IN 3/4" C. UNLESS OTHERWISE NOTED. ALL CONTROL WIRING SHALL BE NOT LESS THAN 2#14, #14G, 3/4"C, UON. ALL CABLES SHALL UTILIZE COPPER CONDUCTORS RATED AT 75C. ALL CABLES INSTALLED IN AIR HANDLING PLENUMS SHALL BE PLENUM RATED CABLE. HOME RUNS SHALL NOT BE COMBINED IN A RACEWAY UNLESS SHOWN ON THE CONTRACT DRAWINGS. SINGLE PHASE BRANCH CIRCUIT HOME RUNS MAY BE COMBINED AT THE CONTRACTOR'S DISCRETION NOT GREATER THAN (3) PHASE CONDUCTORS, (3) NEUTRAL CONDUCTORS, AND GROUNDING CONDUCTOR. EACH SINGLE PHASE BRANCH CIRCUIT CONDUCTOR SHALL HAVE A DEDICATED NEUTRAL BACK TO THE PANELBOARD. SUPPORTING WIRE FOR THE SUSPENDED CEILING GRID SHALL NOT BE USED AS RACEWAY SUPPORT. DISCONNECT SWITCH RATINGS SHALL BE AS INDICATED ON THE DRAWINGS. XXAF, XXAT DESIGNATES "XX" AMP FRAME WITH "XX" AMP TRIP BREAKER. HVAC CONTROL WIRING FURNISHED AND INSTALLED BY DIVISION 23. WIRING AND RACEWAY SHALL BE INSTALLED PER DIV 26 SPECIFICATIONS. TO REDUCE NOISE BETWEEN WALLS, CONTRACTOR SHALL: A. AVOID INSTALLING POWER RECEPTACLES OR DATA OUTLETS LOCATED BACK TO BACK. B. WHERE OUTLETS ARE REQUIRED TO BE LOCATED BACK TO BACK CONTRACTOR SHALL PROVIDE SOUNDPROOFING MATERIAL BETWEEN JUNCTION BOXES. CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING ALL NECESSARY EQUIPMENT FOR ALL DEVICES, MATERIALS AND PRODUCTS SHOWN ON THESE PLANS FOR A FULLY FUNCTIONING SYSTEM. 24. 22. 23. 21. 20. 19. 18. 17. 15. 16. 12. 13. 14. 10. 11. 8. 7. 9. 4. 6. 5. 2. 3. 1. 25. MARK LIGHTING SCHEDULE SYMBOL A MAKE/ MANUFACTURER SUSPENDED FLUORESCENT FIXTURE COOPER LIGHTING CORELITE i2 FROSTED LENS (48")B RE-USE 2'X4' EXISTING FLUORESCENT LAY-IN FIXTURES WITH .125 ACRYLIC PRISMATIC LENS (3) F32T8RS LAMPS WITH RAPID START ELECTRIC BALLAST PROVIDE (2) BALLASTS PER FIXTURE WHERE DUAL SWITCHING IS SHOWN. MATCH EXISTING FOR NEW. BOTTOM OF FIXTURE TO BE 8'-0" A.F.F. ACOUSTIC CEILING TILE. RE-INSTALL EXISTING, OR MATCH EXISTING MANUFACTURER & TYPE FOR NEW. EXIT CEILING MOUNTED EXIT SIGN WITH 6" RED LED LETTERS & 90 MIN. BATTERY BACKUP. LITHONIA #LES-1R- 120/277-ELNSD RE-USE EXISTING FIXTURES. NEW TO MATCH ABOVE. EMERGENCY LIGHT WITH 90 MIN INVERTER BALLAST LITHONIA #25P8G-332-A12125-MVOLT-GEB10RS, OR APPROVED EQUAL. MATCH EXISTING FOR NEW DRAWN BY: WB DATE-03/27/2013 REVISED-04/02/2013 04/10/2013 SHEET E300 PROJECT: MAWR design, inc. WWW. MAWRDESIGN. COM architecture. engineering. interior design 849 S. park drive carmel in 46032 ph-765-453-1745 PROPOSED RENOVATIONS TO SECOND FLOOR UNIT LOCATED 30 WEST MAIN STREET, CARMEL INDIANA TO FACILITATE CARMEL REDEVELOPMENT COMMISSION AND CARMEL UTILITIES CERTIFICATION