HomeMy WebLinkAboutCARMEL MP100.pdf21
5
21
5
EXISTING
UNIT-3
EXISTING
UNIT-2
DN
UP UP
21
5
DN
UP UP
21
5
HVAC PLANNO
R
T
H
NO
R
T
H
SCALE-1/8"=1'-0"
PLUMBING PLANNO
R
T
H
NO
R
T
H
SCALE-1/4"=1'-0"
DRAWN BY: WB
DATE-03/27/2013
REVISED-04/02/2013
04/10/2013
SHEET
MP100
PROJECT:
MAWR design, inc.
WWW. MAWRDESIGN. COM
architecture. engineering. interior design
849 S. park drive
carmel in 46032
ph-765-453-1745
PROPOSED RENOVATIONS TO SECOND FLOOR UNIT
LOCATED 30 WEST MAIN STREET, CARMEL INDIANA
TO FACILITATE CARMEL REDEVELOPMENT
COMMISSION AND CARMEL UTILITIES
CERTIFICATION
CERTIFICATION
EXISTING
UNIT-4
EXISTING
UNIT-18"
8"
8"
6"
8"
8"
8"
8"
8"
6"
T
8"
8"
8"
EX
I
S
T
I
N
G
-
F
I
E
L
D
V
E
R
I
F
Y
EXISTING -FIELD VERIFY
EXISTING -FIELD VERIFY
6"
6"
8"6"
8"8"
EXISTING 16" DIA SPIRAL DUCT
T
T
HVAC LEGEND
24" X 24" DROP IN SUPPLY DIFFUSERS
SQUARE SUPPLY DIFFUSER W/ SADDLES
RETURN VENTS
NEW DUCT LINE
EXISTING DUCT LINE
EXISTING SPIRAL DUCT LINE
NEW SPIRAL DUCT LINE
12"
10"
8"
NOTE:
CARMEL REDEVELOPMENT COMMISSION:
1. MAIN FEED TRUNKLINE TO BE SPIRAL DUCT
2. ALL DIFFUSERS ON SIDE OF SPIRAL DUCTWORK
TO HAVE SADDLES TO MAINTAIN SQUARE GRILLES
3. ALL HEAT RUNS TO HAVE DAMPERS
4. VOID RETURNS
CARMEL UTILITIES SPACE:
1. ALL HEAT RUNS TO BE INSULATED ROUND PIPE
W/ 5" FLEX CONNECTOR
2. MAIN DUCT LINE TO BE INSULATED SHEET METAL
3. VOID RETURNS, USE EGG CRATING TYPICAL
4. ALL SPIRAL DUCT TO PAINTED, REFER TO SHEET
A200 FOR FINISH SCHEDULE CEILING PAINT
8"X24"
8"
X
2
0
"
8"
X
1
6
"
8"
X
2
4
"
8"
X
2
0
"
8"
X
1
6
"
CONNECT PROPOSED 2" SANITARY
TO EXISTING-FIELD VERIFY
2"
RUN WATER LINE FROM EXISTING
TO PROPOSED-FIELD VERIFY
NOTE:
UTILIZE EXISTING WATER HEATER-FIELD VERIFY
NOTE:
SANITARY LINE TO BE RAN UNDER EXISTING SLAB
AND EXPOSED TO MAIN FLOOR IN CEILING.
PAINT PROPOSED SANITARY LINE TO MATCH EXISTING
LAV
EXISTING LAV
2"
NOTE:
SANITARY LINE TO BE RAN UNDER EXISTING SLAB
AND EXPOSED TO MAIN FLOOR IN CEILING.
PAINT PROPOSED SANITARY LINE TO MATCH EXISTING
PLUMBING SCHEMATIC
CERTIFICATION