Loading...
HomeMy WebLinkAbout13070095 Cover SheetMECHANICAL & ELECTRICAL NOTES l. ALL MECHANICAL. ELECTRICAL, PLUMBWG, FIRE SUPPRESSIC3N, AND FIRE ALARM SYSTEMS SHALL BE QESIGNED AND INSTAILED BY THE RESPECTIVE DESIGN/BUIlO CONTRACTORS PER AGREEMENT WITH THE OWNER. ALL TRADES $HALL DESIGN AND WSTALL THEIR RESPECTIVE SYS7EM5 IN ACCORDANCE WITH ALL APPUCABLE STATE AND LOCAL BU{LDING C�DES. COORDINAiE WITH iHE ARCHITECi IF ADDITIONAL INFORMATION IS REQUIRED IN ORdER TO DO iHE WORK iN THE FIELD. SCHOTT DESIGN, INC. D�ES NOT HAVE CHARGE OR RESPONSIBILITY FOR THE DESIGN OR INSTALLATION OF SY$TEMS EXECUTED AS DESIGN/BUILD WITH THE OWNER. 2. H.V.A.C. WORK INDICATED BY THIS DRAWING IS PROVIDED BY THE MECHANICAL ENGINEER. COMPLY WITH THE INDIANA MECHANICAL CODE ANd ALL OTHER APPLICABLE CODES. 3. VERIFY HEAT LOAdS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND PR�VIDE ADDITIONAL AIR FLOW If REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE t�FFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING OWNERILANDLORD. 4. RELOCATE AIR-SUPPLY DIFFUSERS AND RETURN-AIR GRILLES PER MECHANICAL DRAWINGS. CONTRACTQR IS TO PLACE LbCATION OF DIFFUSERS AND REfURN AIR GRILLES AS REQUIRED BY CODE. 5. POSITION LOCATION OF ALL THERMOSTATS AS INDICATED ON MECHANICAL DESIGN. COORdINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR OTHER CONFLICTS. 6. ELECTRIC POWER WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. 7. C�MPLY WffH THE (NDIANA ELECTRICAL AND MECHANICAL COpE AND ALL OTHER APPLICABLE CODES. 8. SIZE AND CIRCUIT ELECTRICAI POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS A$ REQUIREC�. 9. ALL ELECTRICAL OUTLETS WITHW 6'-tY' OF WATER ARE TO BE G.F.C.I. 10. AT EACH PHONE AND DATA JACK, PR�VIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA CONTRACiOR IS RESPONSIBLE FOR PULLING CQNDUCTORS AND PROVIDING APPRQPRIATE TERMINALS AT FACE PLATE. 11. PROVIDE COLORED FACEPLATES FOR ELECTRICAI_ pUTLETS & SWITCHPLATES TO MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE. 12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSiAT10NS WHERE SHOWN. REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS. 13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE SPECIFICATIONS TO OBTAW CIRCUffRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL CONDUITS TO JUNCTION BQXES. 14. ELECTRIC LIGHTING WORK GENERALLY INDICATEq BY THIS DRAWING IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDEk THE GENERAL CONTRACT. PROVIDE A COMPLETE, FUNCTIONAL SYSTEM. 15. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISIING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. 16_ ENSURE THAT ALL MOUNTiNG HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A. REQUIREMENTS. 17. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE {i) GANG BOX WfTH A SINGLE CC3VERPLATE. 18. CENTER CEILING ELEMENTS W CEIUNG TILES, INCLUDING RECESSED DOWNLIGHTS, SMOKE DEfECTORS, SPRINKLER HEADS, AND EXtT SIGNS UNLESS OTHERWISE NOTED. 19. PROViDE EMERGENCY LIGHTING IN TENAN7 SPaCE AS REQUIRED PER NEMA AND IBC. EMERGENCY 6ATfERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 20. PROVIDE ALARM NOTIFICATtON APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS. SMOKE DEfECTORS, FIRE PULI_S, AND ANY OTHER REQUIRED ALARM & DEfECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDWG CODE, INTERNATIONAL FIRE CODE, NFPA). 21. COORDINATE WITH THE OWNER/TENANT PRIOR TC) INSTALLATION OF FIRE DETECTION DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE WALtS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT-INSTALLED ITEMS (I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS). 22. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS W EXISTING SPACES. CONSULT W(TH LANDL�RD. FIRE PROTE�TION NOTES THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 1. FIRE PROTECTION WORK IS TO BE PR�VIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WpRKING SYSTEM. SCHOTf DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 2. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDWG CODE, THE INDIANA FIRE CODE, AND ALL QTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/fIRE SUPPRESSI�N SYSTEMS. 3. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIt;$ HAVING JURISDICTION OVER THE PROJECT. 4. PROVIDE NEW OR RELOCATE EXISTiNG SPRINKLER NEADS AS REQUIRED. PROVIDE MISSWG COVER/ESCUTCHEON PLATES FOR SPRINKLER HERDS WHERE APPIJCABLE. FIELD VERIFY EXISTiNG CONDI110NS PRI�R TO THE START OF W�RK. S. FIRE EXTINGUiSHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE W(fH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FRpM ANY POINT TO A VISIBLE EXTINGUISHER. DOCUMENT APPROVAL GENERAL PROJECT NOTES l. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS �F THE EXISTING BUILDING CONSTRUCT}ON TYPE AS DEHNED BY SECTION 601 OF THE INDIANA BUILDING CODE . 2. ALL WORK SHALL COMPLY WfTH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAI BUILDING CODES. CONTRAC70RS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING C�DE(S) fOR THEIR RESPECTIVE SCOPE Of WORK. 3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSNE OF EXISTING CONDI110NS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES fAMILJAR WITH THE WORK S(TE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENT$ OF THE SCOPE OF WORK. 4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTtON IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR $PECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE. S. VERIFY EXISIING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTf DESIGN, INC. 6. THE GENERAL CONTRACTOR SHALL COORDINATE WfTH iHE OWNER REGARDING ALL ON-SITE ACTIVITIES; SUCH AS. BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDIJNG, DELIVERIES, ACCESS T� THE W�RK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO CQORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERAII PROJECT SCOPE. 7. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER i0 CONDUCT BUSINESS IN A$AFE ANb CLEAN ENVIRONMENT. 8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE PROIECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SCHOTf DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACiOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT RE5PON318LE FOR DELAYS RESULTING FROM THE C�NTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. 9. SUBSTffUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPftOVAL FROM THE DESIGNER. SUBMfT REQUESTS FOR SUB5TITUTIONS WItH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISI�N. iQ. SCHOTf DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, ANd SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFEfY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTNNING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES. 1 1. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTf DESIGN, INC. FOR APPR�VAL ON ALL MATERIALS OR ITEMS WHERE THE C�NTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. 12_ THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOMS FACILITIES $HALL BE APPROVED BY iHE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. 13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITION$ TO MINIMIZE DISTURBANCES OF DA1LY TENANi OPERATIONS DURING DEMOLITIDN AND CONSTRUCII�N WORK. DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS � 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH SIDE. 14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICT$ ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF iHOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTW�RK MAY PREVENT THE INSTALLATION OF LIGHTING flXTURES AS INDICATED ON THE CEILING PLAN). 15. SCHOTf DESIGN, INC., IS NOT RESPONSIBIE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE. 16. PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, EfC. FINISH NOTES 1. ALL FINISHES SHALL COMPLY WITH CHAPTER $(INTERIOR FINISHES) �F THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. 2. FOR ALL NEW DRYWAIL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. fSUCH AS, CONTROL JOINTS, FINISH LEVEIS, FASTENERS, TAPING DETAILS, CORNER BEADS, EfC.) 3. ALL NEW PLATES AND SWITCHES ARE TO MATCH EXISTING COLOR, UNLESS OTHERWISE NOTED. REMOVE ALL PLATES BEFORE PAINTING AND REATfACH AFfERWARDS. CONTRACTOR TO CONHRM EXISTING COLOR PRIOR TO PURCHASING NEW. 4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FlNISH COATS. 5. FOR CHANGE IN FLOOR HNISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS TO MATCH VINYL BASE COLOR (IE.: WHERE VCT MEEfS CARPET). b. WHERE LIMffS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLEfS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. 7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLfTION HAS OCCURRED. 8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WfTH FIRE RETARDANT PAINT TO MATCH ADIACENT WALL FINISH. 9. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIRED) TO SCHOTf DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FiNISHING PROCESS OF ALL MILLWORK. 10. REFERENCE INTERIOR ELEVATION 8 SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION. 1 l. ALL PAINTS AND ADHESIVES/SEALANTS SHAII HAVE LOW VOC CONTENT. 12. ALL ADHESIYES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS. 18. EXPEDtTE PREPARATION AND SUBMITfAL OF ALL SHOP DRAWINGS TO ALLOW SUFflCIENT TIME FOR CHECKING. APPROVAL, ORDERiNG, FABRICAiION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 19. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORQANCE WITH THE BE5T QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL W�RK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAI BUILDING COQES, AND STANDARDS FflR GENERAL, MECHANICAL, AND ELECTRICAL C�NSTRUCTI�N. 20. ALL DEfAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FlNAL APPROVAL BY THE OWNER. 21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. HELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPRdVED FOR ANY CONDI110NS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. 22. FURNRURE, OFFICE EQUIPMENT, OFRCE PART1T10N SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR fTEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PR�VIDED AS PART OF THE W�RK UNLESS SPECIHCALLY STATED TO BE PROVIDED. 23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD OAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 24. PATCH ALL GYPSUM WALIBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWAIL, TAPE, SPACKIE AND PREPARE FOR FINISH. 25. ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE SUPPRESSION, ANd FIRE ALARM SYSTEMS SHALL BE DESIGNED AND INSTALLED BY THE CONTRACTORS PER AGREEMENT WITH THE OWNER. ALL TRADES SHALL DESIGN AND INSTALL THEIR RESPECTIVE SYSTEMS IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. COORDiNATE WfTH THE ARCHITECT IF ADDITIONAL INFORMATION IS REQUIRED IN ORDER TO DO THE WORK IN THE FIELD. SCHOTf DESIGN, INC. DOES NOT HAVE CHARGE OR RESPONSIBILfTY FOR THE DESIGN OR INSTALLATION OF SYSTEMS EXECUTED AS DESIGN/BUILD WITH THE OWNER. 26. WHEN REQUIRED BY STATE BUILDING CODE. THE CONTRACTOR(S) SHALL PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL, OR FIRE SUPPRESSION. DRAWINGS SHALL BE CERTIHED BY A LICENSED ENGINEER AND SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW. 27. ALL EQUIPMENT AND/OR FlXTURE$ SHALL BE WSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 28. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLEfION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER i0 THE pWNER IN A CONDITION THAi REPRESENTS THE HIGHEST LEVEL Of CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCE S WORK & DO NOT LEAK. 29. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE CO1v1PlET10N QF THE PROJECT. 30. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, �R FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WR(TTEN DIMENSIONS GOVERN. 31. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING �MINDOW BLINDS. REPLACE ANY DAMAGED OR MI$$ING WINDOW BLiNDS WITH NEW TO MATCH BUILDING STANDARD. 32. THE GENERAL CONTRACiOR SHALL BE RESPONSIBLE FpR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMIITING ALL REQUIRED DRAWINGS AND SUPPORIING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMR DEPARTMENT. ALL REQUIRED LOCAL PERMR FEES SHALL BE PAID BY THE GENERAL CONiRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. 33. FlRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE-RATED CAULK AS DIRECTED 6Y LOCAL JURISDICTIONS. 34. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTRIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED T� FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 35. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIREd TO RECENE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED. MILL/CASEWORK NOTES 1. CASEWORK AND MILLW�RK GENERALLY INDICATED ON THESE DRAWINGS ARE T� BE PROVIDED UNDER THE GENERAL CONTRACT. 2. UNLESS INDICATED OTHERWlSE, COMPLY WfTH ARCHiTECTURAL WOODWORK INST�TUTE (A.W.I.J CURRENTSTANDARDS fOR CUSTOM GRADE WOODWORK. 3. FURN�SH SHOP DRAWMGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION. 4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED. VERIFY ALL DiMENSIONS ON PLANS AGAINST DIMENSIONS OF fiS-BUILT COND(TIONS IN FIELD. REPORT ANY DISCREPANCIFS TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FiT RELD CONDITIONS UNLESS DOING SO WILL SIGNIRCANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. 5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION DRAWINGS WfTH RNISHES INDICATED ON THE pNISH PLAN/SCHEDULES. IMMEDIATELY REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. b. REFER TO MILLWORK SECTIONS 8 ELEVATIONS . UNLE$S OTHERWISE SHOWN, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPL�.SHES WHERE INDICATED. BACKSPLASHES TO BE FlELD APPIIED. 7. REFER TO NULLWORK SECTIONS & ELEVATIONS FOR CABINEfRY SPECIFICATIONS (CUSTOM PLASTIC LAMINATE OR PRE-MANUFACTURED STOCK CABINEfRY�. 8. TO PROVIDE BLOCKING iN WALL$ FOR ALL nnILLWORK, WALI STOPS, HARDWARE, AND CABINETRY WHERE SPECIRED. ALL WOOD BLOCKING TO BE HRE RATED. TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN-OFF OF THESE DOCUMENTS SHALL BE THE fULI RESPONSIBILfTY OF THE TENANT/CLIENT. THESE DRAWINGS, AND THE IDEAS, DESIGNS AND C�NCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY Of SCHOTf DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRIITEN CONSENT Of $CHO7T DESIGN. DEMOLITION NOTES 1. CQQRDINATE DEMOLITION WITH NEW WORK C�NSTRUCTION DRAWINGS IN ORDER TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. 2. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED. OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTEd OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS DURING DEMOLIitON/CONSTRUC110N. THE CONTRACTOR SHALL VERIFY IN THE FIELD, PRIOR TO DEMOLI110N, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL. CONTACT SCHOTf DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE FIELD SUSPECT THAT AN IiEM NOTED FOR DEMOIITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE CAUTION WHEN DEMOIISNING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE Td THE BUILDING STRUCTURAL SYSTEM. 3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE IiEMS OF WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE O�NNER'S REQUESTS. 4. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDWG TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 5. REMOVE ALL EXISTING WALLS AND DOORS WNERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOL(fION PLAN. VI$ff AREA OF WORK T� ASSURE EXTENT OF DEMOLITION. b. REMOVE ALL CARPEf, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. REFER TO fINiSH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN. 7. REMOVE ALL ELECTRICAL OUTLEfS AND CONDUCTORS AS REQUIRED OR INDICATED. SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION. 8. REFER TO DEMOLI110N PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID INSTRUCTIONS. 9. USE CARE TO PROTECT EXISTINC, BUIIDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH AS, @UT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND flNl$HES. THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, Ai THE CONTRACTOR'S COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE BEEN REASONABLY PRbTECTED AND MAINTAINED IN GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT. 10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION) REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING 6UT NOT LIMITED TO: DATA WIRING, CQMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES. REFER TO SECTION 300.21. 11. WHERE FIXTURFS OR EpUIPMENT RRE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFEiY REGUTATiONS OR PROCEDURES. MARK, LABEL. OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE_ CONTRACTOR i0 PROVIDE AN "AS-BUILT' SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEM$. 12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDWG OWNER/IANDIORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS. METAI STUDS, DRYWALL, CARPEi, CEILING T1LES, DOORS,GLASS, AND CABINETRY. _ _ E'..��n5� _ ... , ` �` :- :� � ; � _ M :. . ., . _ °-' ; z '- _ � • a.�_, •� � ,;� ti: _� � � � aennsyN�ua �`t�, t:�', ; 6 ,_� �.: �� �. 4: � � � � � 8 b < � . � �s��� Af z � 'o VICINITY MAP � �.�,�..� ��.�.�,���N NOT TO SCALE KEY PLAN - 4th FLOOR NOT TO SCALE R�b;�qSFa F �tf°��� �R�O C� p�CprOFofsfat a��d�o� �fh�s �Rf/�'r��/V ��FCAR/yjMM�NIa� d�s latro�s /Np����Ay �R�ICFS ANA wNSH/p �� � INDEX OF DRAWINGS T11 1 COVER $HEET AND GENERAL PROJECT NOTE$ LiQO t1FE SAFEfY PLAN Dl 11 DEMOLtT10N PLAN A111 ARCHRECTURAL FL��R PLAN A121 REFLECTED CEWNG PLAN: HVAC / L1GHTiNG A131 fINISH PLAN A141 RESTROOM dETAILS A211 DOOR SCHEDULE A212 INTERIOR DETAiIS El 1 1 ELECTRICAL PLAN E301 GENERATOR - ELECTRICAL PLAN (BY OTHERS) E302 GENERAiOR - ELECTRICAL PLAN (BY OTHERS) M301 MECHANICAL PLAN jBY OTHERS) �T T � � � � � � � � 'L��� �°, � �v��� � � � ^ r � a���� ��M�� � _ � � Q� � U � p" N a0 ��(� N a � � � Q� � THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE WTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WfiHOUTTHE WRITiEN CONSENT OF SCHOTT DESIGN. � � N � � Z W � W � � J � O � N Z �a = J Q d. Q QW � z � � O � � O � �Cp„Q � � � � Q � � � J V � ma Q - � � � Q W � � J � Z w � � o RF �"E G'/aE/a%" � / /'y�. t! IE 0.TE DESCRIPTION �.13 REVIEW SET �.13 PERMR/BID SET ISONS DATE DB DESCRIPTION PROJECT NUMBER 2013.010 PROJ. MGR DRAWN BY ACM ACM/TMK ' COVER SHEET AND GENERAL NOTES �` 't� `�J� ��g�� ��� t��( f7 �y�1� I ' 4` a�� � �'� A �'�f��!���j r.� e=`l `�� t"^ 8 �3t�� � ' �� � �� ;iif/ �b`�`'+�(�i;� � �j�1��� �, � � - � � c ���t`j ���1. � �����°I^��+ �����'� � � �`���`���P a4�