HomeMy WebLinkAbout13070095 Electrical Plan First Floor� w a � 0 z S � z � � x � � ;-� � 0 � _ U L �V tL w > 0 N in � � � J 0 � � m � a M N ;-� M � 0 N � M � � � � a TELEC�M R��M UP T❑' 4TH � .:: .. FL❑❑R ELECTRICAL R❑❑M PARTIAL FIRST FLOOR ELECTRICAL PLAN SCALE� 1/8' = 1'-0' EXISTING PANEL SCHEDULE PANEL NAME: 4PE LOCATION: 4TH FLOOR TELECOM RM PROJECT INFQ VOLTAGE: 120/208 VOLT, 3 PH, 4 WIRE MOUNTING: SURFACE PROJECT NAME: BLACKBAUD RATING: 250 AMP, MAIN LUGS FED FROM: PANEL 4PA 200A CIRCUIT BREAKER PROJECT NO: 13-068 ENCLOSURE: NEMA 1 5/31/2013 BREAKE LOAD IN KVA LOAD IN KVA BREAKE CKT DESCRIPTION P TRIP LTS RECP MOTO HEAT MISC "A" "B" "C" LTS RECP OTO HEAT MISC P TRIP DESCR{PTION CKT 1 WORKSTATION RECP 1 20 0.4 0.7 0.4 1 20 TRAINING ROOM RECP 2 3 WORKSTATION RECP 1 20 0.4 0.7 0.4 1 20 TRAINING ROOM RECP 4 5 WORKSTATION RECP 1 20 0.4 0.7 0.4 1 20 TRAINING ROOM RECP 6 7 WORKSTATION RECP 1 20 0.4 0.7 0.4 1 20 TRAINING ROOM RECP 8 9 SPARE 1 20 0.0 1 20 SPARE 10 11 SERVER ROOM RECP 1 20 0.5 0.5 1 20 SPARE 12 13 SERVER/RACK-UPS 2 30 3.0 3.0 1 20 SPARE 14 15 3.0 3.0 1 20 SPARE 16 17 SERVER/RACK-UPS 2 30 3.0 3.0 1 20 SPARE 18 �g 3.0 3.0 1 20 SPARE 20 21 SERVER/RACK-UPS 2 30 3.0 3.0 1 20 SPARE 22 2g 3.0 3.0 1 20 SPARE 24 25 SERVER/RACK-UPS 2 30 3.0 3.0 1 20 SPARE 26 2� 3.0 3.0 1 20 SPARE 28 29 SERVER/RACK-UPS 2 30 3.0 3.0 1 20 SPARE 30 31 3.0 3.0 1 20 SPARE 32 33 SERVER/RACK-UPS 2 30 3.0 3.0 1 20 SPARE 34 35 3.0 3.0 1 20 SPARE 36 g7 5.0 5.0 1 20 SPARE 38 39 15KVA TRANSFORMER FOR 3 50 5.0 5.0 1 20 SPARE 40 41 LIEBERT UNIT 5.0 5.0 1 20 SPARE 42 18 18 18 TOTAL CONNECTED LIGHIING LOAD (KVA) 0 TOTAL DEMAND LIGHTING LOAD (KVA) 1.0 0 NOTFS: EMERGENCY POWER FEED: 57KW TOTAL CONNECTED RECP LOAD (KVA) 3 TOTAL DEMAND RECEPTACLE LOAD (KVA) 1 3 GENERATOR TOTAL CONNECTED MOTOR LOAD (KVA) 0 TOTAL DEMAND MOTOR LOAD (KVA) 1 0 TOTAL CONNECTED HEATING LOAD (KVA} 0 TOTAL DEMAND HEATING LOAD (KVA) 1 0 TOTAL CONNECTED MISC. LOAD (KVA) 51 TOTAL DEMAND MISC. LOAD (KVA) 1. 51 TOTAL CONNECTED LOAD (KVA) 54 TOTAL DEMAND LOAD (KVA) DF 54 EXISTING �ANDSCAP AREA i I � i i I � i � 1� : I� �� � �i �i I�i � i� 3 __ _ EXISTING LANDSCAPE AREA C�NTROLS TD ATS �7 P�WER T❑ ATS 7O .�,°"„'",,,""""",",,,,,,,,,,, ELECTRICA� SCOPE ❑F W❑RK ��.��� ��SN A P,y �. �ii,,�� ��-Q:.�'��STfR••:F� '� . ADDED NEW C�NDUIT AND FEEDER C❑NDUCTORS FR�M REL�CATED :��.ti <``p••: , 57kw GENERATOR T❑ F�URTH �L��R TELEC�M ROOM. : No. PE10100899`_ ' � NOTED L�CATI❑N ❑F RELOCATED AUT�MATIC TRANSFER SWITCH '' ��� IN F�URTH FLDOR TELEC�M RODM AND ADDED NEW SAFETY � sTarE oF :' ��` � ' �N�lANP.'' : SWITCH, °''%i,,, 0 A E�°° . ADDED NEW 208V - 200A BREAKER IN EXISTING PANEL 4PA F❑R � �� THE ATS NORMAL POWER FEED, 5� ���3 • NOTED UTILIZING EXISTING PANEL 4PE F�R EMERGENCY P�WER ❑NLY, ADDED A NEW 208V - SOA BREAKER FOR NEW 15KVA TRANSFORMER FEED. • ADDED A NEW 15KVA 208V - 480V STEP UP TRANSFORMER AND 480V - 20A BREAKERS THAT FEED EXISTING S T�N, 480V LIEBERT CO�LING UNIT T� BE ON EMERGENCY P�WER, • ADDED NEW 277V NORMAL P❑WER CIRCUITS F�R NINE C9) NEW HEAT PUMPS THAT SUPPORT AREAS ❑N THE F�URTH FLDOR. -ENCE �HER ING RELOCATED 'AT�R *�- GENERAL N�TES� 1. CONTRACTOR SHALL EXCAVATE ENTIRE RACEWAY LENGTH BEF�RE BEGINNING INSTALLATI�N. FIELD VERIFY ALL INTERFERENCE WITH BURIED UTILITIES. 2. C�NTRACTOR SHALL FIELD VERIFY EXACT L�CATIONS ❑F EXISTING UTILITIES (TYPICAL), IMMEDIATELY REP❑RT ANY DISCREPANCIES T❑ THE ENGINEER THAT MAY INTERFERE WITH THE INSTALLATIDN ❑F NEW WORK. 3, C�NTRACTOR SHALL VERIFY ALL DIMENSIDNS CVERTICAL AND H�RIZONTAL) IN THE FIELD PRI�R T� STARTING CONSTRUCTIDN, C❑NTRACT�R SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS, IF ANY DISCREPANCIES ARE F❑UND IN THESE PLANS FR�M THE ACTUAL FIELD CONDITIONS, CONTRACT�R SHALL N❑TIFY THE ENGINEER IMMEDIATELY, 4, ALL W�RK SHALL CONF❑RM T� STATE AND L❑CAL REGULATIDNS. 5, EXCAVATING CONTRACT�R SHALL TAKE PARTICULAR CARE WHEN EXCAVATING IN AND AROUND EXISTING UTILITY LINES, EQUIPMENT AND EXISTING STRUCTURES, VERIFY C�VER REQUIREMENTS BY UTILITY C�NTRACT❑RS AND UTILITY C�MPANIES S❑ AS NOT T� CAUSE DAMAGE. CONTRACT❑R MAY NEED T❑ HAND DIG IN AREAS CLOSE T❑ UTILITIES AND THE BUILDING STRUCTURE. 6. C❑NTRACT❑R SHALL N�TIFY ❑WNER AND ALL UTILITY C❑MPANIES A MINIMUM �F 72 H�URS BEF�RE C❑NSTRUCTION IS T� START, T❑ VERIFY IF ANY UTILITIES ARE PRESENT ❑N SITE, ALL VERIFICATIONS (LOCATI�N, SIZE, AND DEPTH> SHALL BE MADE BY THE APPROPRIATE UTILITY COMPANIES. WHEN EXCAVATING IS AROUND ❑R ❑VER EXISTING UTILITIES, THE CONTRACT❑R SHALL N❑TIFY THE UTI�ITY COMPANY S❑ A REPRESENTATIVE ❑F THAT UTILITY COMPANY MAY BE PRESENT T❑ INSTRUCT AND ❑BSERVE DURING C�NSTRUCTION, 7, C�NTRACT❑R SHALL SUPPORT ALL PIPING, DUCTBANK, AND C�NDUITS SPANNING THE TRENCH EXCAVATI�N. 8. CONTRACT�R SHAL� MAINTAIN A MINIMUM COVER ❑F 3'-0' FOR ALL ELECTRICAL RACEWAYS UNLESS �THERWISE N❑TED, 9, ALL CUTTING, PATCHING, TRENCHING, �R SITE W�RK REQUIRED SHALL BE PAID FOR BY THIS C�NTRACT�R AND PERF�RMED BY THE APPROPRIATE TRADE, AT PROJECT C�MPLETION SITE WHERE BURIED C�NDUIT T❑OK PLACE SHALL MATCH EXISTING C❑NDITI�NS, 10. PLACEMENT �F GENERAT�R AND GENERAT❑R PAD SHALL BE BY ❑THERS, 11, LANDSCAPING PLAN AND NEW PRIVACY FENCE SHALL BE BY OTHERS, MINIMUM DISTANCES SHALL BE MAINTAINED F�R CLEAR W�RKING SPACE AND AIR FL�W AR�UND GENERAT�R, 12. USE EMT C�NDUIT(S) INSIDE THE BUILDING. 13. STRAP/SUPP�RT VERTICAL C�NDUITCS) USING UNISTRUT AND 'C' CLAMPS. 14, USE PVC-40 C❑NDUITCS) F❑R UNDER GR�UND C�NDUIT. STUB-UP ELBOW WILL BE 'GRC', � / ' • C / ` � PLAN N�TES� O1 C�NTRACTOR SHALL SHALL COORDINATE WITH UTILITY C�MPANY T❑ PR❑VIDE NATURAL GAS CONNECTI❑N T� THE GENERAT❑R AND C�NNECTI❑N T❑ THE NEW GAS METER. O2 CONTRACTOR SHALL TRENCH NEW RACEWAY FROM GENERATOR T❑ � BUILDING. C�ORDINATE STUB UP LOCATION WITH SH�P DRAWINGS ❑N EXISTING GENERATpR, � F- O3 C�NTRACT�R SHALL R�UTE RACEWAY ABOVE LAY-IN CEILING T❑ J W FIRST FL��R ELECTRICAL RO�M. Q Q W 4 O C�NTRACTOR SHALL INSTALL 3/4" DIAM E T E R B Y 8'- 0' L O N G C O P P E R V/ a O, CLAD GR�UND R❑D DRIVEN INT� GR�UND. C�NNECT T❑ GENERAT�R � � I G R O UND WITH #1/ 0 C OPPER CABLE. J W a F- � 5O C❑NTRACTOR SHALL C�RE DRILL EXTERI�R WALL AT FIRST FL❑OR � I FINISH FLO�R LEVEL, PENETRATI�N SHALL BE SEALED WATER TIGHT, � O Z' PR❑VIDE LB AT EXTERI�R WALL PENETRATI�N, � � z� O6 CONTRACT�R SHALL C❑RE DRIL� FL❑ORS AND FIRE ST�P AS Q V� REQUIRED UP TO F�URTH F�O�R ELECTRICAL RD❑M. � Z Q � U7 REFER T❑ P❑WER SCHEMA7IC ❑N SHEET E-302 FOR ADDITI�NAL p Q SC❑PE, � � Y W 8O C�NTRACT�R SHAL� PROVIDE PULL BOX. SIZE ❑F PULL B❑X SHALL � Q COMPLY WITH NATIpNAL ELECTRIC CODE. Z -� O m � I • / / • I�t10W W�'tat'8 ��OW. Cetll be�ore you d�g. b KEYPLAN SCALE� NONE PROJECT NO.: DWG FILE: 13-0� DATE DWG SCALE: 1 /� PLOT SCALE: DRAWN BY: DRAWING NO. �