HomeMy WebLinkAbout13070095 Life Safety PlanCODE SUMMARY
1 I SCOPE OF WORK
2
3
4
5
6
7
8
9
10
11
12
OCCUPANCY CLASSIFICATION
CHANGE OF OCCUPANCY CLASS�
TOTAL BUILDING AREA
TOTAL PROJECT AREA
OCCUPANCY CALCULATIONS
NUMBER OF REQUIREQ EXITS
SPRINKLER SYSTEM {YES/NO)
TOTAL AREA OF ACCESSORY USES
TOTAL AREA ON THE FLOOR
ACCESSORY AREA EXCEEDS 10%
FiRE WALLS, AND/OR OCCUPANCY
SEPARATIONS fIF REQUIRED)
LEGEND
OFFICE SPACE BUILD-OUT REMODEL TO PREVIpUSLY
BUILT-0UT OFFICE
B(USINESS)
NCl
33,83Q SF/FLOOR
34,555 SF
SPACETYPE
GEN.OFFICE ,
4 STORIES �_ � 135,319 SF
AREA SF PER OCCUPANT OCCUP LOAD
1,555 SF 100 346
TOTAL OCCUPANTS IN PROJECT AREA
2
YES - EXISIING TO REMAIN
a SF
33,830 SF
NO
NJA
Ep EXISTING ELECTRICAL PANEI �OCATION
EX Ex�snNG exrr
FE PIRE EXflNGUISHER
� EXIT SIGNAGE
�' EMERGENCY L�GHTING
NLEL NIGHT LIGHT/EMERCsENCY LIGHTING
_ _ __ .
_ __ __. _ _ _
_ _.
346
LIFE SAFETY NOTES
l. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATfERY PACKS OR LIGHTS CONNECTED
Tp AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE
CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR
REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES {HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER
REQUIRED ALARM & DEfEC110N SYSTEMS AS NECESSARY TO MEET All
APPLICABLE CODES (INTERNATIONAL BUILbING CODE, INTERNATIONAL
FIRE CODE, NFPAj.
3. FIRE PROTECTION WORK IS TO BE PROVIdED 8Y DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTf DESIGN, INC., IS NOT RESPONSIBLE FOR THE
DESIGN, INSTALLATION, OR RENOVATION OF THE flRE SPRINKLER SYSTEM.
4. THE FIRE PROTECTION CONTRACTi?R SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORIIIES HAVING
JURISDICTION OVER THE PROJECT.
5. FlRE EXTINGUISHERS: CONTRACTOR TD ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10.
COORDINATE WITH OWNERJLANDLORD ON EXTINGUISHER TYPE AND
HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEEf FROM ANY POINT TO
A VISIBLE EXTINGUISHER.
f
GENERAL NOTES
U. REFER TO SHEET A11 1 FOR WALL TYPE AND CONSTRUCTION DEfAILS
L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS,
FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES FO
REMAIN. ADJUST EXISTING DEVICES TO MEET CURRENT CODFS IF THEY
ARE NOT IN COMPLIANCE.
❑ AREA NOT IN CONTRACT
� AREA OF WORK
__ _ ._._.
__ _ _ _ _ ..
LIFE SAFETY PLAN
o �' a' te• N
u
3/32" = 1'-0"
�
�
; �
.'^ .��OO O
vJ
W �vl�� C?
� ��'� �
� a ���•�,
� � � � �
� M��-
= O
� � �
� � � � N
� � � �
N �
I� S Q �i-
' THIS DRAWWG, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
' HEREIN, ARE THE EXCLUSIVE
; INTELLECTUAL PROPERTY OF SCHOTf
' DESIGN, WC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR '
IN PART, WITHOUT THE WRITTEN
CONSENT OF $CHOTf DESIGN.
�
, � !
' N
' �O ;
I � '
Z
' W -
W t/'3
� J '
_ �
1� �
'. N �
� Q z
� � �
a. �
aW �z
ma� �
�°��Q
o��
�
���
Q°`��
J V �
m Q Q
o z
_ Q
W �
G J
�
t�
z '
W '
�
r---
O
�
ISSUE
DATE DESCRIPTION
5.6.13 REVIEW SET '
' 6J.13 PERMff/BID SET
REVISONS
MARI DATE DB DESCRIPTION '
PROJECT NUMBER
2013.010
' PROJ. MGR DRAWN BY
' ACM ACM/TMK
LIFE SAFETY PLAN