HomeMy WebLinkAbout13070002 Generator Enclosure ASH� � a C� � 0 � � ui � Q z m � U J J � � a � � � � � � 0 M � ti � � O � � � -� � � ,, � _ � � �: � w� _ �u 23'-1" � U U i C.J. �` � � � c.�. � � _ � M N C.J. � �` ��� ����� �k� , 7'-0" 3�-6" 5'-0° I 0 ' ^ � ( ' ;°,, ! � I � � � � i , o � % � � � I __. I 3'-6" ( � � I 9" 20'-6" -' � � �T _ _ � '/ i / � , � - // / //I 1'-2" __/1 L _ � � 1 � ( N _^ °p ZV _^ 23,-8�� 25'-T' 6" THICK CONCRETE PAD (17'-0" x 21'-8") (COORDINATE WITH UNITS) CONDENSING UNITS ZV � (V 1'-2" � (V _^ 1'-2" PLAN VIEW — GENERATOR LOCATION 1 /8" =1'-0" CONTINUOUS SAWCUT CONTROL JOINT (SEE NOTES 1 AND 2) � U , \ �--� 1/4" MAXIMUM 1 1/4" MINIMUM �� , � ARCHITECTURAL PRECAST PANEL WALL �o 0 N 8" THICK GENERATOR PAD GRAVEL BED AT PERIMETER SLAB ON GRADE: SEE GENERAL NOTES DRAWING FOR CONCRETE MIX REQUIREMENTS PROVIDE SYNTHETIC FIBERS IN SLAB ON GRADE MIX �. � '�F`` �� �— WWF 4x4 W4.0 x W4.0 ' ' (ALTERNATE #4 BARS AT 9" O.C. EACH WAY) 6" COMPACTED FREE DRAINING GRANULAR MATERIAL NOTES: 1. SAWCUT JOINT AS SOON AS POSSIBLE AFTER THE CONCRETE HARDENS. THE CONCRETE IS HARD ENOUGH WHEN THE BLADE DOES NOT DISLODGE AGGREGATE, AND WHEN THE EDGES OF THE CUT DO NOT RAVEL. COMPLETE SAWCUTTING BEFORE SHRINKAGE STRESSES BECOME SUFFICIENT TO PRODUCE CRACKING. 2. PREPARE AND SEAL JOINT . TYPICAL SLAB ON GRADE JOINT DETAIL AND CONSTRUCTION 2 1 1 /2" =1'-0" 4 � CV M SHIM AS REQUIRED GROUT FOOTING CONTINUOUS AFTER ERECTION GRADE EL. 0'-0" � ; � : #4 AT 36" O.C. (4�-#4 x CONT. 3'-0" SECTION 1/2" =1'-0" ARCHITECTURAL PRECAST CONCRETE PANEL, TO MATCH RED PRECAST ON BUILDING 1 GRAVEL BED o �. ,,1 . 1 REINFORCE WITH W WF 4x4 W4.0 x W4.0 CONCRETE SLAB v \ �� `� �. � 1 �-0" _ #b DOWELS AT 2'-0" O.C. PROJECT 1'-0" GENERAL NOTES FOUNDATIONS 1. PREPARE AREAS OF THE SITE SUPPORTING STRUCTURE BY REMOVING TOPSOIL, EXISTING FILL, ORGANIC MATERIAL, OR FROZEN, WET, SOFT, LOOSE OR OTHERWISE UNSUITABLE MATERIALS REPLACE WITH WELL-GRADED GRANULAR FILL. 2. PROOFROLL THE EXPOSED SUBGRADE WITH A MEDIUM-WEIGHT ROLLER TO DETERMINE IF ANY POCKETS OF SOFT, UNSUITABLE MATERIAL EXIST BENEATH THE EXPOSED SUBGRADE. REMOVE ANY UNSUITABLE MATERIAL ENCOUNTERED AND REPLACE WITH A WELL COMPACTED GRANULAR MATERIAL. 3. PROPER PLACEMENT AND COMPACTION OF ENGINEERED FILL IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PLACE FILL MATERIAL IN LAYERS NOT EXCEEDING 8 INCHES IN LOOSE THICKNESS. MECHANICALLY COMPACT EACH LAYER. 4. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED MATERIAL. IF UNSUITABLE MATERIAL IS ENCOUNTERED, REESTABLISH THE BEARING ELEVATION OF THE FOOTING BY LOCALIZED UNDERCUTTING, AND FILLING WITH SUITABLE GRANULAR MATERIAL OR CONCRETE. 5. PLACE FOOTINGS THE SAME DAY EXCAVATIONS ARE OPENED. IF THIS IS NOT POSSIBLE, ADEQUATELY PROTECT THE EXPOSED MATERIAL IN THE BASES OF THE FOOTING EXCAVATIONS FROM ANY DETRIMENTAL CHANGE IN CONDITION SUCH AS FROM DISTURBANCE, RAIN OR FREEZING. SURFACE RUNOFF SHALL NOT BE ALLOWED TO ENTER THE EXCAVATIONS. OVEREXCAVATE THE EXISTING EXCAVATIONS TO A MINIMUM DEPTH OF ONE FOOT BELOW THE FOUNDATION ELEVATION AND BACKFILL WITH ENGINEERED FILL CONSISTING OF COARSE AGGREGATE IN ORDER TO PROVIDE A MORE UNIFORM BEARING. 6. THE OWNER SHALL RETAIN A LICENSED TESTING AGENCY TO DETERMINE THE MINIMUM ALLOWABLE NET BEARING PRESSURE AT THE COLUMN FOOTING LOCATIONS IS 2000 PSF. THE MINIMUM ALLOWABLE NET BEARING PRESSURE BENEATH THE SLAB ON GRADE WILL BE 1000 PSF. REINFORCING STEEL FOR CAST-IN-PLACE CONCRETE 1. PROVIDE MINIMUM CONCRETE COVER FOR REINFORCING STEEL IN ACCORDANCE WITH THE ACI "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-05), UNLESS OTHERWISE INDICATED. 2. REINFORCING STEEL SHALL BE SUPPORTED AND SECURED AGAINST DISPLACEMENT IN ACCORDANCE WITH THE CONCRETE REINFORCING STEEL INSTITUTE'S "MANUAL OF STANDARD PRACTICE". 3. DETAILS OF REINFORCING STEEL FABRICATION AND PLACEMENT SHALL CONFORM TO ACI "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" (ACI 315) AND "MANUAL OF ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES" (ACI 315R) UNLESS OTHERWISE INDICATED. 4. REINFORCING STEEL BENDS, HOOKS AND LAP SPLICES SHALL CONFORM TO THE ACI "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-05) UNLESS OTHERWISE INDICATED. 5. PROVIDE STANDEES FOR THE SUPPORT OF TOP REINFORCEMENT FOR FOOTINGS AND MATS. 6. FIELD BENDING OF REINFORCING STEEL IS PROHIBITED. CAST-IN-PLACE CONCRETE 1. THE MIXING, HANDLING, PLACING AND CURING OF CONCRETE SHALL BE IN ACCORDANCE WITH THE ACI "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-05). 2. CURING OF SLABS: CURE SLABS WITH CURING COMPOUNDS OR MOISTURE RETENTION COVERS. CONCRETE SCHEDULE 28 DAY AIR CONCRETE CLASS COMPRESSIVE CONTENT PLACEMENT REMARKS STRENGTH A 3000 PSI OPTIONAL FOOTINGS WATER REDUCING ADMIXTURE REQUIRED B 4000 PSI 6+/- 1% EXTERIOR SLABS ON GRADE W/C RATIO .45 MAX CONCRETE SCHEDULE NOTES: 1. CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS FOR EACH MIX USED TO ENGINEER FOR APPROVAL. 2. ANY CONCRETE NOT INDICATED IN THE SCHEDULE SHALL BE CLASS B. 3. INCLUDE AN AIR-ENTRAINING ADMIXTURE IN MIX DESIGNS FOR CONCRETE EXPOSED TO FREEZING AND THAWING DURING SERVICE AND FOR CONCRETE EXPOSED TO COLD WEATHER DURING CONSTRUCTION BEFORE ATTAINING ITS REQUIRED 28 DAY COMPRESSIVE STRENGTH. �� ti L m °o � � �N w� �� � � ci � W C) C � ,cb U� � yc a� � � �� � � O U Q � �ro y �c � o ,N � �a � � O � � � � W � � ~ � � � � �/ I � � � Z U -� w � Z � �� w = Z U %�� � Vi � • � ~ Q � oZ � � Q Vo � � � z �..�..� o� w �- z z J O O w � � Q N � !$VE DATE DESCRIPTION 07.15.13 REVIEW SET EVISONS ARI DATE DB D G�0 RGE'+►,� ���G� � T�9� D 1 � ���Q No, o'�t9.� � � ` AR19���0118 ,':: z � t�y �STA?'E OF r � 'f•'�D i ANPr} �RCHITEG� ruwNu � r *: f �, �......._. � �;.a' �>e+�+ , : :: ,,- ` e. PROJECT NUMBER 1 PROJ. MGR DRAWN BY W H A� GENERATOR ENCLOSURE