HomeMy WebLinkAbout0448.98.reflected ceiling plan;�
�'
�
/
�,
�
i'
�
�.
\,
�
� ii .
��.
, �
�-� �7
�
FIRST FLOOR KEY PLAN
�Ca�E tiOr�E
NORTH
REFLECTED CEILING PLAN
SCALE: t; 8" = 1'-0"
REFLECTED CEILING PLAN
GENERAL NOTES
1. EXISTING CEILING SYSTEM TO REMAIN. REPLACE ANY DAMAGED OR
MISSlNG TILES TO MATCH EXiSTiNG. CONTRACTOR TO VERIFY EXISTING
GRID LAYOUT AND CONDITION.
2 ELEC?RICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD
OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO UERIFY
QUANTITY ANC FLACEMENT OF INDICATED SAFETY DEV�CES
(EXIT SIGNS, ALARMS, etc.) AND VERIFY CONFORMANCE
WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR
IS RESPONSIBLE FOR SUBMITTING NECESSARY GRAWINGS FOR
REVIEW AND GBTAINING PERMITS.
3. ALL ROOM WALLS TO UNDERSIDE OF SUSPENDED CE!LING TYPICAL
UN�ESS OTNERWISE ►vOTEO, SEE WALL TAGS AND WALL LEGEND ON
SHEET ?A201 FOR MORE INFORMATION.
4. PATCH, REPAIR, ANO/OR REPLACE CEILING GRID SYSTEM WHERE WALLS,
LIGHT FIXTURES OR PARTITIONS HAVE BEEN REMOVED. MATCH EXISTING.
5. RE-USE EXISTING LIGHT FIXTURES, CLEAN SALVAGED FIXTURES,
RE-LAMP AND REPLACE ANY DAMAGED LENSES. EXISTING LAMPS ARE
C00! WHITE. ANY NEW FLUORESCENT F�XTUR.ES ARE TO MATCH EXISTING.
6. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD
CONTRACTOR TO VERIfY EXISTING CONDITIONS AND COORDINATE
DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER
NEADS, FIRE PROTECTIUN DEVICES, EXIT UGHTS, EMERGENCY
NIGHT �IGHTS, AND THERMOSTAT;. DESIGN-BUI�D CONTRACTOR
TO COORDINATE HIS WORK WITH THE LIGHTING PLAN.
ALL �UESTIONS ARE TO BE BROUGHT TO THE ATTENTION
OF TNE DESIGNER BEFORE PROCEEDING. ,
? PE+NE E^�GiNEERING iS TO BE Hvar SUB-CONTRACTOR, PER BUi�DiNG
MANAGEMENT'S REQUEST
REFLECTED CEILING LEGEND
��� NEW OR RELOCATED 2 X 4 FLUORESCENT
L_.�- FIXTURE WITH PRISMATIC ACRYUC LENS
�NEW OR RELOCATED 2 X 4 FLUORESCENT
P FLUORESCENT FIXTURE W�TH PARACUBE LEN;
UGHT FIXTURE TO BE
�.t NIGHT I.iGHT (ALL LAMPS
- NON-SWITCHED)
--- CEILING MTD. EXIT
�8ft ^ LIGHT W/DIRECTION
----- - - INDICATION DUAL-LITE
'-`-- ' 2 X 2 lAY-IN GRID
SUSPENSION SYSTEM -
' - EXIST�NG TO REMAIN
�
.�
e
EX!ST�NG SPRINKLER HEAO TO RE�AAIN
Exi;TiNG RECESSED DOwNUGHT TO BE RE�OCaTED �S SHOwN
EXISTING WALL WASHER FIXTURE TO BE RELOCATED AS SHOWN.
• NEW INCANDESCENT DOWNUGHT
MFG: UTHONIA
SERIES: GOTHAM
TYPE: R6t�8 90W PAR/CAP
DESCRIPTION: 6" APERTURE, BIACK BAFFLE
O N
$
�a
$D
DOWNUGHT TO BE NIGHT UGHT (NON-SWITCHED}
SWITCH
4-WAY SWITCH
DIMMER SWITCH
REFLECTED CEILING PLAN NOTES
Ri RELOCATE SPRINKLER AS REQUIRE� TO ACCOMGDATE NEW CONSTRUCTION.
R2 PENDANT fIXTURE (BY TENANT) TO BE INSiALLED BY G C.
R3 EXISTING EXIT SIGN TO REMAIN
R4 INSTALLL NEW SPRINKLER AS SHOWN