Loading...
HomeMy WebLinkAbout13070084. Construction Plan� Attach slip track to underside of deck. Provide acoustical sealant. D Framed to deck above U.L. Listed fire rated sealant (1/4 bead) @ fire rated wall types. Sound batt insulation above ceiling. E�end 2'-0" min. each side of wall. Suspended acoustical ceiling tile - refer to room finish schedule. Refer to wall type schedule for wall construction. TOP OF WALL CONDITION DETAILS � i��� _ � �_�„ Single Door Frame Tempered Glass Single Door Frame and sidelight FRAME TYPE LEGEND HARDWARE LEGEND Hardware Set #1 3 Hinges 1 Passage Latch 1 Wall Stop 3 Mutes Finish: Bldg. Std. Hardware Set #2 3 Hinges 1 Office Lock 1 Door Stop 3 M utes 1 Coat Hook Finish: Bldg. Std. Hardware Set #3 3 Hinges 1 Storeroom Lockset 1 Door Stop 3 Mutes 1 Closer 1 Door Holder Finish: Bldg. Std. Sound batt insulation above ceiling. E�end 2'- 0" min. each side of wall. Suspended acoustical ceiling tile - refer to room finish schedule. Spacer as required, typ Continuous acoustical tape, typ Casing bead floated, typ Metal runner channel fasteners at 2'-0" o.c., max Refer to wall type schedule for wall construction. GI Framed to ceiling grid. Insulate ceiling 2'-0" (min.) each side of wall c� Flush Full Light DOOR TYPE LEGEND � oor Frame (Typ.) lall Construction - Refer Floor Plan for Wall Type Door Frame (Typ.) Wall Construction - Refer to Floor Plan for Wall Type Note: Unless othervvise noted or dimensioned on plans, provide 6" of space at hinge side of door frames. TYP. DOOR JAMB DETAIL �„ _ ��_��� G Framed to ceiling grid Suspended acoustical ceiling tile - refer to room finish schedule. Spacer as required, typ Continuous acoustical tape, typ Casing bead floated, typ Metal runner channel fasteners at 2'-0" o.c., max Refer to wall type schedule for wall construction. SCHEDULE - WALL TYPES Wall Construction Top of Wall Construction Wall Type Stud Size Insulation Fire Rating U.L. or G.A. # Description Code Description M2 0' - 2 1/2" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board G Framed to ceiling grid each side M3 0' - 3 5/8" No -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board G Framed to ceiling grid each side M3S 0' - 3 5/8" Yes -- Metal studs @ 16" O.C. with (1) layer 5/8" gypsum board each side �pp�" ' �OOP Pkn'�ber' T�me W H T Ma�berial Finish - �1���. _� 1.=.� , �. .i��. Finish ! Har�dvvare ._ , ` 206 � Full Light 3' - 0" 8' - 0" 1 3/4" Wood Match Existing Single Wood Match Existing 1 Salvaged Door. Install Full Light Kit. 212 '� Flush 3' - 0" 8' - 0" 1 3/4" Wood Match Existing Single door and sidelt. Wood Match Existing 2 24" sidelight ' 214 Flush 3' - 0" 8' - 0" 1 3/4" Wood Match Existing Single Wood Match F�cisting 3 215 I Full Light 3' - 0" 8' - 0" 1 3/4" Wood Match Existing Single Wood Match Existing 2 ' 217 I Flush 3' - 0" 8' - 0" 1 3/4" Wood Match Existing Single door and sidelt. Wood Match Existing 2 24" sidelight 218 I Full Light 3' - 0" 8' - 0" 1 3/4" Wood Match Existing Single Wood Match Existing 2 '� CONSTRUCTION PLAN vs° _ , ,-o,. NORTH GENERAL NOTES - CONSTRUCTION A. Refer to Project General Notes and Reference Specifications on sheet A001 regarding new construction, finishes and additional associated project requriements. B. Wall construction and/or patching of walls, where existing doors are demolished, is to match existing adjacent wall construction conditions, unless noted otherwise. C. Provide air-tight acoustical and/or fire-rated sealant around perimeter of all wall types with acoustical insulation. D. All joints and penetrations of fire rated assemblies to be sealed with approved U.L. listed "F" and "T" systems. Submit product data and installation information prior to installation for Architect's approval. Label/identify fire rated partitions for future reterence on each side of wall above ceiling, concealed from view. Note the UL assembly designation with 6" red stenciled letters E. Dimensions are taken from the face of masonry walls, column centerlines, finish face of existing walls and/or stud face of new walls unless otherwise indicated. F. Verify all critical dimensions within and/or related to the existing building. Dimensions and conditions indicated were determined by visual survey and/or information from existing drawings. G. +/- Dimension is equal to verify in field. H. Plans are not to be scaled for finish or wall information. Contractor to contact Carson Design Associates for any questions or clarifications on plan dimensions. J. Smooth, patch, repair and install new construction surfaces as rqeuired to receive new finishes. Reference finish drawings for additional information. GENERAL NOTES - DOOR & HARDWARE 1 Door stops to be floor mounted unless othervvise noted in door schedule remarks. Provide blocking inside wall for all wall mounted stops. 2 All new and existing doors to receive building standard lever style accessible handles. 3 All existing doors to be repaired for any damaged, scratched or wom areas. 4 All office doors to receive (1) coat hook. All coat hooks to be mounted on center of door at 5'-0" a.f.f. 5 Egress doors shall be readily openable from the egress side without the use of a key, special knowledge or effort. In group A occupancies having an occupant load less than 300, and group B,M & S occupancies, the main exterior door(s) are permitted to be equipped with key operated locking devices or deadbolt from the egress side provided that the locking device is readily distinguishable as locked and a readily visible durable sign is posted on the egress side on or adjacent to the door stating "This door to remain unlocked when building is occupied". The sign shall be 1" high letters on a contrasting background. Refer to 2009 International Building Code Section 1008.1.8.3,2.,2.2 (Veriiy with local building code requirements). 6 Hardware Specifications given communicate perFormace and design intent. Contractor shall coordinate hardware submittal to comply with all building standard styles, finishes and specifications. Substitutions may be allowed unless noted othervvise. 7 Contractor shall coordinate scope for all security devices, conduit, power and junction box requirements with security vendor. 8 All access-controlled egress doors shall comply with IBC Seciton 1008.1.4.4. Door hardware supplier shall verify compliance and recommend to Architect any modifications to the door hardware group as required. PLAN LEGEND � F�cisting Partition to Remain � New Partition - Non-Insulated � New Partition Insulated Door - Refer to Door Schedule 101 � Existing Door to Remain - Type of Wall Stud M = Metal Stud Framing - Wall Stud Size / Tvpe 2 = 2 1/2" Stud Size 3 = 3 5/8" Stud Size 6 = 6" Stud Size M3 S = Sound Insulation o F = Fire Rated - Top of Wall Conditions (See Standard Top of Wall Condition Details) G = Grid GI = Grid / Insulation +6 = +6 Above Grid D= Framed to Deck Above R = Fire Rated OConstruction Key Note(s) Indicates area not in project scope. O CONSTRUCTION PLAN KEYED NOTES 1 Prep entry doors for electric strikes. 2 Install finro new waterlines in Breakroom. GC to confirm exact locations with Tenant. 3 Install 3 new full height panes of glass (equal in width) in wood framing along entire wall � j� , '. i � �� � . ��.�1 , ��y�Wq�' ��� � �. g��� , _ � , � qy, ���� . �y��„ � � ,� � � � �, ,�� � � . y� � O � — � .� V � -� Z � _ � - :� � �O�•`n _ � �N� ■� � , � � LL .� w �' � ,�^ � � � v' � _ � O � � J M � ■� � � � STAM P ���.,��„�,,,�� . . �`��'���NY ••.9 ��,���i �STE ',��� � • � ��G RFp'• �2 ,,,i : No. = _ :11200176: : i STATE OF � ,��j,,,� '.� �ND:AN P .� � ,,,��,, ���'�cH �� .�``°,� � . �� 05/01/13 ISSUE: � Tenant Review 05/01/13 DRAWING TITLE: Construction Plan JOB NO. 11227707 DATE: 05/Ol/13 SHEET NUMBER: A201 COPYRIGHT 2013 CARSON DESIGN ASSOCIATES