HomeMy WebLinkAbout13070084. Electrical Plan1 ELECTRICAL LOCATION PLAN 1/8" = 1'-0" NORTH GENERAL NOTES - ELECTRICAL A. Refer to Project general Notes and Reference Specifications on sheet A001 for information regarding new construction and electrical lighting. B. All dimensions are from finished wall surface or column centerline to centerline of outlets or centerline of pairs of outlets. C. All wall mounted wiring devices and receptacles shown back-to-back shall be offset a minimum of 8" and acoustically sealed. D. Where direct connection to prewired furniture panels occurs, provide power and telecommunication feeds to indicated panel locations from wall, column or floor source directly adjacent to this location. E. All existing floor mounted electrical/telecommunication locations which are not reused are to be removed. Remove all associated cable, wire and conduit back to the source. Properly patch and repair affected wall, floor and/or ceiling construction. F. Unless otherwise noted, all device elevations refer to centerline. G. All outlets that are in the vicinity of any wet areas (kitchens, break rooms, restrooms, janitorial rooms with floor sinks, laundry rooms, stand alone wall mounted sinks, electrical water fountains, etc.) ground fault circuit interrupt (G.F.C.I.) type. See Electrical Legend. H. Furniture will be provided by tenant and is shown for reference only. J. Floor poke-thru devices in hard surface floors shall be provided with completely flush closure plate. Floor poke-thru devices in carpet floor shall have an ADA compliant bezel trim unless noted otherwise. Floor penetrations & Devices shall be fire rated as required to match existing construction. K. Contractor to coordinate with tenant on workstation furniture specifications to obtain circuitry requirements prior to running electrical and conduits, to junction boxes. Coordinate any floor penetrations required with furniture layout and specifications prior to install of floor or wall penetrations. L. Where multiple switches are shown, provide 1 gang box with a single cover plate. M. Provide alarm notification appliances, (horns/ strobes) emergency speakers, smoke detectors, fire pulls and any other required alarm and detection system as necessary to meet all applicable codes or jurisdiction having authority requirements. NOTE: Electrical and Data shown for general reference only. Design by others. Conctractor shall field verify all existing conditions prior to bid and/or start of construction. 2 3 4�. 5. E�. 7. 8'�. MECH, ELEC, & PLUMBING DESIGN REQ. Contractor is responsible for the design required to obtain approvals and permits for complete installation of all associated assembies including but not limited to Mechanical, Electrical, Smoke, Fire Alarm, Sprinkler and Plumbing systems. Design Shall be certified by a licensed Engineer and Submitted to jurisdictions having authority as required. All work shall be completed per code and jurisdiction having authority requirements. No Exceptions. The design and installation of Mechanical, Electrical and Plumbing systems shall comply with all requirements and standards of all applicable codes, governmental regulations, ordinances, state and local requirements. There are no engineered HVAC drawings provided for this project. Contractor shall be responsible for providing appropriate heating, cooling, and humidity control as applicable in all spaces, including existing spaces outside the scope of this project that are re-configured by the new construction. Coordinate any conflicts that may arise in the field with architect or owner. Provide HVAC and balance report at the project completion for all areas affected by construction. Verify heat load of any special equipment or densities of occupants and revise supply, zoning and thermostat location as required. Do not design any single space to be on a split zone unless otherwise approved by landlord or tenant in writing. There are no engineered plumbing/sprinkler drawings provided for this project. Contractor to field verify existing systems including piping, valves, fixture locations and sizes. Sprinkler contractor will be responsible for providing adequate sprinkler layout in all spaces reconfigured by new construction. All work is to match existing. Coordinate with architect and owner on any conflicts that may arise in the field. There are no engineered electrical drawings provided for this project. Architectural drawings have been provided to show intended use of the space. Contractor shall be responsible for re-wiring existing light fixtures, switches, outlets and miscellaneous devices outside the scope of this project that are re- configured by the new construction. All circuits are to be labeled at the panel in a clear/legible manor. Coordinate with architect any additional required work not shown here, or any conflicts that may arise in the field. Architectural drawings shall take precedence over other trades' drawings when conflicts arise. Bring conflicts or inconsistencies between architectural drawings and other disciplines to the attention of the architect prior to bid, order and installation. Existing hard duct to remain as is. No new ductwork required. Re-work flexible duct to new diffuser locations. Carson Design Associates Inc. does not have charge or responsibility for the design or installation of systems executed as design build or otherwise executed with others. Note: E.C. and/or design build contractor is to verify that project meets Indiana ��SHRAE 90.1 energy codes. Design intent is to be within watts per square foot. Provide energy managment controls, such as sensor controls <ultrasonic and motion detection) and/or relay time clocks, as required by the code. Indiana required energy compliance report (ComCheck) is the responsibility of the awner or owner's representative. Drawings, specifications and energy control devices are shown with the intent of ineeting current state energy codes. Submitting party is to alert designer and owner of any additional devices or load changes necessary to adhere to the code prior to submission of ComCheck. ELECTRICAL LEGEND Wall mounted duplex outlet at �' standard height. P Wall mounted telephone and data shared outlet. N Indicates new or relocated item � `�y�'., �' �� Indicates area not in project � ,. . / scope. Indicates no electrical work in this area. 0 ELECTRICAL LOCATION PLAN KEYED NOTES Install a duplex outlet and data outlet at 60" AFF for TenanYs TV. GC to coordinate exact location with Tenant. Anchor to building structure and brace structure as required for structural integrity of all assemblies. , ,,,� � � i!% /Oqy�� % � � , � G� � ..... G/// . � , .., � �°d �°°, � � �� �,� , ; ,4 � -z � , , ,� ,: ' , ""�` �� �„%� � � � � „� �. . , .., . � O � � � ■� V � �' Z � _ � � � � O v_i = i' � N O ■� � , � � LL s w �' � � �+ � � � � � J � � � � ■� � s � STAMP: � � � �,, , . , � � , � � ..,,,. .�' ��NY..:�< �'�. ',,���P�����G � S 7 ER�o ��2 ��,' ' No. ' . . _ _ : :11200176: : i STATE OF � ,,���,,���•. �ND:AN � .� � ,,,��,, ���'RcH �� ��G ��, � , t,C��Q1n� _ 05/01/13 ISSUE: 0 Tenant Review 05/01/13 DRAWING TITLE: Electrical Location Plan JOB NO. 11227707 DATE: 05/01/13 SHEET NUMBER: A203 COPYRIGHT 2013 CARSON DESIGN ASSOCIATES