HomeMy WebLinkAbout13070084. Electrical Plan1 ELECTRICAL LOCATION PLAN
1/8" = 1'-0"
NORTH
GENERAL NOTES - ELECTRICAL
A. Refer to Project general Notes and Reference Specifications on sheet A001 for
information regarding new construction and electrical lighting.
B. All dimensions are from finished wall surface or column centerline to centerline of
outlets or centerline of pairs of outlets.
C. All wall mounted wiring devices and receptacles shown back-to-back shall be offset
a minimum of 8" and acoustically sealed.
D. Where direct connection to prewired furniture panels occurs, provide power and
telecommunication feeds to indicated panel locations from wall, column or floor
source directly adjacent to this location.
E. All existing floor mounted electrical/telecommunication locations which are not
reused are to be removed. Remove all associated cable, wire and conduit back to
the source. Properly patch and repair affected wall, floor and/or ceiling
construction.
F. Unless otherwise noted, all device elevations refer to centerline.
G. All outlets that are in the vicinity of any wet areas (kitchens, break rooms, restrooms,
janitorial rooms with floor sinks, laundry rooms, stand alone wall mounted sinks,
electrical water fountains, etc.) ground fault circuit interrupt (G.F.C.I.) type. See
Electrical Legend.
H. Furniture will be provided by tenant and is shown for reference only.
J. Floor poke-thru devices in hard surface floors shall be provided with completely
flush closure plate. Floor poke-thru devices in carpet floor shall have an ADA
compliant bezel trim unless noted otherwise. Floor penetrations & Devices shall be
fire rated as required to match existing construction.
K. Contractor to coordinate with tenant on workstation furniture specifications to
obtain circuitry requirements prior to running electrical and conduits, to junction
boxes. Coordinate any floor penetrations required with furniture layout and
specifications prior to install of floor or wall penetrations.
L. Where multiple switches are shown, provide 1 gang box with a single cover plate.
M. Provide alarm notification appliances, (horns/ strobes) emergency speakers, smoke
detectors, fire pulls and any other required alarm and detection system as necessary
to meet all applicable codes or jurisdiction having authority requirements.
NOTE: Electrical and Data shown for general reference only. Design by others. Conctractor
shall field verify all existing conditions prior to bid and/or start of construction.
2
3
4�.
5.
E�.
7.
8'�.
MECH, ELEC, & PLUMBING DESIGN REQ.
Contractor is responsible for the design required to obtain approvals and
permits for complete installation of all associated assembies including but not
limited to Mechanical, Electrical, Smoke, Fire Alarm, Sprinkler and Plumbing
systems. Design Shall be certified by a licensed Engineer and Submitted to
jurisdictions having authority as required. All work shall be completed per code
and jurisdiction having authority requirements. No Exceptions.
The design and installation of Mechanical, Electrical and Plumbing systems shall
comply with all requirements and standards of all applicable codes,
governmental regulations, ordinances, state and local requirements.
There are no engineered HVAC drawings provided for this project. Contractor
shall be responsible for providing appropriate heating, cooling, and humidity
control as applicable in all spaces, including existing spaces outside the scope
of this project that are re-configured by the new construction. Coordinate any
conflicts that may arise in the field with architect or owner. Provide HVAC and
balance report at the project completion for all areas affected by construction.
Verify heat load of any special equipment or densities of occupants and revise
supply, zoning and thermostat location as required. Do not design any single
space to be on a split zone unless otherwise approved by landlord or tenant in
writing.
There are no engineered plumbing/sprinkler drawings provided for this project.
Contractor to field verify existing systems including piping, valves, fixture
locations and sizes. Sprinkler contractor will be responsible for providing
adequate sprinkler layout in all spaces reconfigured by new construction. All
work is to match existing. Coordinate with architect and owner on any conflicts
that may arise in the field.
There are no engineered electrical drawings provided for this project.
Architectural drawings have been provided to show intended use of the space.
Contractor shall be responsible for re-wiring existing light fixtures, switches,
outlets and miscellaneous devices outside the scope of this project that are re-
configured by the new construction. All circuits are to be labeled at the panel
in a clear/legible manor. Coordinate with architect any additional required work
not shown here, or any conflicts that may arise in the field.
Architectural drawings shall take precedence over other trades' drawings when
conflicts arise. Bring conflicts or inconsistencies between architectural
drawings and other disciplines to the attention of the architect prior to bid,
order and installation.
Existing hard duct to remain as is. No new ductwork required. Re-work flexible
duct to new diffuser locations.
Carson Design Associates Inc. does not have charge or responsibility for the
design or installation of systems executed as design build or otherwise
executed with others.
Note: E.C. and/or design build contractor is to verify that project meets Indiana
��SHRAE 90.1 energy codes. Design intent is to be within watts per square foot. Provide
energy managment controls, such as sensor controls <ultrasonic and motion detection)
and/or relay time clocks, as required by the code.
Indiana required energy compliance report (ComCheck) is the responsibility of the
awner or owner's representative. Drawings, specifications and energy control devices
are shown with the intent of ineeting current state energy codes. Submitting party is to
alert designer and owner of any additional devices or load changes necessary to
adhere to the code prior to submission of ComCheck.
ELECTRICAL LEGEND
Wall mounted duplex outlet at
�' standard height.
P Wall mounted telephone and data
shared outlet.
N Indicates new or relocated item
� `�y�'.,
�' �� Indicates area not in project
� ,. . / scope.
Indicates no electrical work
in this area.
0 ELECTRICAL LOCATION PLAN KEYED
NOTES
Install a duplex outlet and data outlet at 60" AFF for TenanYs TV. GC to coordinate
exact location with Tenant. Anchor to building structure and brace structure as
required for structural integrity of all assemblies.
, ,,,�
� �
i!%
/Oqy�� %
�
�
, �
G�
� ..... G/// . � , ..,
� �°d �°°, � � �� �,� ,
;
,4
� -z
� , , ,�
,: ' ,
""�` �� �„%� � � � � „�
�. .
, .., .
�
O
�
�
�
■�
V � �' Z
� _ �
� � � O v_i
= i' � N O
■� � , � �
LL s w �' �
�
�+ � � � �
� J � �
�
�
■�
�
s
�
STAMP:
� � � �,, , . , � � , � � ..,,,.
.�' ��NY..:�< �'�.
',,���P�����G � S 7 ER�o ��2 ��,'
' No. '
. .
_ _
: :11200176: :
i STATE OF �
,,���,,���•. �ND:AN � .� � ,,,��,,
���'RcH �� ��G ��,
� , t,C��Q1n� _
05/01/13
ISSUE: 0
Tenant Review 05/01/13
DRAWING TITLE:
Electrical Location
Plan
JOB NO. 11227707
DATE: 05/01/13
SHEET NUMBER:
A203
COPYRIGHT 2013 CARSON DESIGN ASSOCIATES