1/16" = 1'-0"
FE = Fire extinguisher NORTH
CODE INFORMATION
1. Applicable Codes
Indiana Administrative Rules
2008 Indiana Building Code (2006 International Building Code with Indiana Amendments)
2008 Indiana Fire Code (2006 Intemational Fire Code with Indiana Amendments)
Americans with Disabilities Act Accessible Guidelines (ADAAG) for Buildings and Facilities
American National Standards Institute Accessible and Usable Buildings and Facilities Standard (ICC/ANSI 117.1-2003)
2009 Indiana Electrical Code (2008 NEC with amendments)
2008 Indiana Mechanical Code (2006 IMC with state amendments)
2012 Indiana Plumbing Code 2006 IPC with State Amendments
2. Summary Notes
This project does not involve a change of Use or Occupancy Classification for the existing building
Any existing construction inside the designated scope of work area shall remain as is unless otherwise noted.
Total building area = 53,725 SF
Total scope of work = 3,023 SF
Total building height (stories) = 1 stories
CODE - OCCUPANCY CLASSIFICATION � LOADS
Level Occupant Classifications Occupancy Classification Description Function of Space Area Floor Area Per Occupant Occupant Load Number of Required Exits
B
Level 1 B Business Business Areas 3,023 SF 100 31 1
Construction Type
IIB
CODE - CONSTRUCTION TYPE
Sprinklered Allowable Travel Distance Maximum Dead End
5�rinklered 300' - 0" � 50' - 0"
Maximum Common Path of Travel
100' - 0"
SYMBOL LEGEND
O- Keyed Note. Refer to Keyed Note Schedule on same sheet.
101 - Door number
Room Name_ Room Name, Size and Number
���
3 TYP. ALIGNMENTS
3/4" = 1'-0"
Existing construction
(wall, column wrap, etc.)
to remain (typ.)
Align face of any new
construction w/ face of
adjacent existing
construction to remain
unless otherwise indicated.
�/- Elevation Number
1
A101
Sheet Number
Section Number
SIM
1
A101 Sheet Number
Detail Number
SIM
1
A101 Sheet Number
, Enlarged Plan or �
Detail
�-------�
QRevision
� Elevation Target
Fire strobe (where applicable)
Thermostat (where applicable)
Door and hardware as scheduled
Switch(es) - Multiple switches shall be ganged
together under a single faceplate unless
otherwise indicated.
Notes:
1. Provide blocking on studs to align centers of
back boxes.
2. All dev�ces and coverplates shall have no
visible manufacturer names or identification. If
applicable, refer to electrical drawings and
specifications for receptacle device colors.
Outlets - If within 1'-6" horizontally
of door jamb, align with switch
and/or other devices
Existing construction
(wall, column wrap, etc.)
to remain (typ.)
Align face of any new
construction w/ face of adjacent
existing construction to remain
unless otherwise indicated.
Proposed interior wall
construction. Refer to floor
plans for wall type.
2 TYP. WALL ALIGNMENT DETAIL
�:�
Refer to floor plan for wall types.
Metal stud blocking between
vertical studs
Semi-recessed fire extinguisher
cabinet. Refer to floor or code
plans for locations. Anchor cabinet
to double studs at jambs.
Wood blocking as required
Wood shims as required at
sill and jambs.
Note: Coordinate minimum required wall thickness with fire
extinguisher cabinet manufacturer prior to purchase. Size and type of
extinguisher must meet all applicable code requirements.
1 SEMI-RECESSED FEC
1" = 1'-0"
Note: Contractor shall ensure all
new and existing fire extinguishers
are installed according to NFPA
standards. Coordinate with
owner/landlord regarding
extinguisher type and housing
required.
ABBREVIATIONS
A.F.F./AFF Above Finished Floor
ACT Acoustical Ceiling Tile
APP/APPR Approximate
OX.
AWT Acoustical Wall Treatment
B.O. Bottom of
BLKG Blocking
BOT Bottom
CAB Cabinet
CJ Control Joint
CL Center Line
CMU Concrete Masonry Unit
COL Column
CONC Concrete
CONST Construction
CPT Carpet
CT Ceramic Tile
CW Cold Water
DET Detail
DF Drinking Fountain
DIM Dimension
DP Deep/Depth
DWG Drawing
E.T.R. Existing to Remain
EA Each
EIFS Exterior Insulation Finish System
EJ Expansion Joint
EL Elevation
ELEV Elevation
EWC Electric Water Cooler
EXIST Existing
EXIST'G F�cisting
EXP Expansion or Exposed
EXT Exterior
F Fabric/Textile
FD Floor Drain
FE Fire Extinguisher
FEC Fire Extinguisher Cabinet
FIN Finish
FLR Floor
FT Feet
GA Gauge
GB Grab Bar
GL Architectural Glass (Art Glass)
GWB Gypsum Wall Board
H. High/Height
HDWR Hardware
HM Hollow Metal
HORIZ Horizontal
HVAC Heating, Ventilation and Air Conditioning
HW Hot Water
JST Joist
JT Joint
KIT Kitchen
LAM Laminate
LAV Lavatory
LF Laminate Flooring
LLH Long Leg Horizontal
LLV Long Leg Vertical
M Metal
M.O. Masonry Opening
MANUF Manufacturer
MAS Masonry
MAX Maximum
MB Marker Board
MECH Mechanical
MEZZ Meuanine
MFG Manufacturer
MIN Minimum
N.I.C. Not in Contract
O TO O Out to Out
O.H. Opposite Hand
OD Outside Diameter
OPNG Opening
OPP Opposite
PL Plastic Laminate
PLAM Plastic Laminate
PLWD PlyHrood
PS Projection Screen
PT Paint
R Riser
RA Retum Air
REF Reference
REFR Refigerator
REQD/RE Required
Q'D
RF Rubber Flooring
RO Rough Opening
SA Supply Air
SC Sealed Concrete
SCHED Schedule
SEC Section
SF Square Foot
SIM Similar
SPECS Specifications
ss sona s���
ST Stone
STD Standard
STL Steel
SUSP Suspended
T Tread
T.O. Top Of
TB Tack Board
TEL Telephone
TMPR Tempered
TR Trim (Includes stair treads, nosings,
transition strips, comer guards, etc.)
N Television
TYP Typical
TZ Terrazzo
UNO Unless Noted Othervvise
UR Urinal
V.I.F. Verify in Field
VCT Vinyl Composition Tile
VERT Vertical
VT Vinyl Tile
VWC Wallcovering
W. Wid�dth
W/ With
W/O Without
WB Wall Base
WD Wood
WF Wood Flooring
WH Water Heater
WKP Working Point
WP Wall Protection
XXX-D Indicates finish to be determined
XXX-E Indicates existing finish to remain
� %; ,
��� �,//
% i
� � '
��i,y
�' �
����i/ , � �
��� , � �� /,
��.�����n� � � g ,. �
�
O
�
�
�
■�
V
�
�
_
■�
�
�
�
�
�
■�
�
�
�"
�
�
�
�
�
�
�
�
J
� z
in —
� O .N
�N �
w � �
�
���
� �
STA M P ���..�„��,,,��
♦ ♦
�O�'���Nl'•••9 ��,���i
� •����5 T • ♦
',,� P�� ��G � ER�O �� �A ��,'
r�
? No. :
: :11200176: :
i STATE OF �
,��i�,,���•. �ND�ANP .�,� ,,,���,
.,��RcH;; ,�G� .
�~�� � �
� 05/01/13
ISSUE: �
Tenant Review 05/01/13
DRAWING TITLE:
General and Code
Information
JOB NO. 11227707
DATE: 05/Ol/13
SHEET NUMBER:
A002
COPYRIGHT 2013 CARSON DESIGN ASSOCIATES