HomeMy WebLinkAbout13070084. Reflected Ceiling Plan2 1REF,ELECTED CEILING DEMOLITION PLAN
NORTH
1 �REFLECTED CEILING PLAN
NORTH
Reflected Ceilinq Plan Demolition Legend
Refer to general demolition notes for additional information.
Oj
�-�
i i
i � � i
i � i
i i
�_�
�r ��
�� y�
-�--�-
� �
-�—�-
;�
Indicates existing 2x4 fixture to remain.
Indicates existing 2x4 fixture to be removed.
Indicates existing diffuser to be removed.
Indicates existing ceiling grid
to be removed.
Indicates existing ceiling grid to
remain.
Indicates area not in contract.
No ceiling construction
in this area.
LEGEND - REFLECTED CEILING
Wall mounted light switch.
Coverplate color to match
p Building Standard 2x4 parabolic existing.
fluorescent light fixture
�
Building Standard 2x4 parabolic
fluorescent light fixture on night
lighbemergency circuit
O Recessed Downlight Fixture
� Recessed Wallwash Downlight
Fi�ure
:
�
N
Building Standard illuminated exit
light. Solid area denotes direction
of face plate.
Existing ceiling grid to
remain.
Indicates new ceiling grid to be
installed to match existing grid.
Indicates relocated item
Indicates new item.
Note: All items shown will be existing to
remain unless noted otherwise.
� 3-Way switch
� Dimmer switch
oC� Occupancy Sensor
� Diffuser - Supply (existing
unless otherwise noted)
� Diffuser - Return (existing
unless othervvise noted)
� Recessed Linear Diffuser
Emergency light fixture with
� emergency exit lighting
pack and battery back up.
Coordinate exact locations
with engineer�urisdiction
having authority
requirements.
Indicates area not in
contract.
No ceiling construction
in this area.
I GENERAL NOTES - REFLECTED CEILING
A. Refer to Project General Notes and Reference Specifications on Sheet A001 for
specifications regarding new construction and finishes and additional associated
project requirements.
B. The architectural reflected ceiling plan shall govern the layout of all ceiling elements
and/or penetrations. If applicable, coordinate any field verified or as-built conditions
that differ from what is shown on these plans with the Architect.
C. Sizes of inechanicaf equipment (if shown) are for reference only. If applicable,
coordinate actual sizes with the Mechanical Engineer.
D. Sizes and shapes of lighting and other miscellaneous electrical equipment (if shown)
are for reference only. If applicable, coordinate actual sizes with the Electrical
Engineer.
E. Install suspended ceiling grid with equal size panels at each side or end of the
individual spaces unless otherwise indicated. No panel shall be less than 4" wide.
F. All ceiling mounted items (sprinkler heads, mounting mechanisms, etc.) shall be
centered in the ceiling panels unless otherwise indicated.
G. Where existing ceiling grid is remodeled to meet new construction, the contractor
shall:
A. Replace all damaged or un-repairable portions of the existing grid with new
grid to match the existing building standards.
B. Remove portions of the existing grid or provide new grid as required by new
construction. All new grid must match existing grid to remain or match the existing
building standards.
C. Replace all damaged ceiling tiles with new tiles to match the existing to remain
or that match the existing building standards.
H. Provide night light circuits as required by the Building Code.
J. Contractor to provide an allowance for replacement of all damaged ceiling tiles in
areas of project scope.
K. Repair areas of damaged ceiling grid and suspension system as required for
structural integrity of ceiling and all associated assemblies.
NOTE: Electrical and Data shown for general reference only. Design by others. Conctractor
shall field verify all existing conditions prior to bid and/or start of construction.
MECH, ELEC, & PLUMBING DESIGN REQ.
1. Contractor is responsible for the design required to obtain approvals and
permits for complete installation of all associated assembies including but not
limited to Mechanical, Electrical, Smoke, Fire Alarm, Sprinkler and Plumbing
systems. Design Shall be certified by a licensed Engineer and Submitted to
jurisdictions having authority as required. All work shall be completed per code
and jurisdiction having authority requirements. No Exceptions.
2. The design and installation of Mechanical, Electrical and Plumbing systems shall
comply with all requirements and standards of all applicable codes,
governmental regulations, ordinances, state and local requirements.
?�. There are no engineered HVAC drawings provided for this project. Contractor
shall be responsible for providing appropriate heating, cooling, and humidity
control as applicable in all spaces, including existing spaces outside the scope
of this project that are re-configured by the new construction. Coordinate any
conflicts that may arise in the field with architect or owner. Provide HVAC and
balance report at the project completion for all areas affected by construction.
Verify heat load of any special equipment or densities of occupants and revise
supply, zoning and thermostat location as required. Do not design any single
space to be on a split zone unless otherwise approved by landlord or tenant in
writing.
��. There are no engineered plumbing/sprinkler drawings provided for this project.
Contractor to field verify existing systems including piping, valves, fixture
locations and sizes. Sprinkler contractor will be responsible for providing
adequate sprinkler layout in all spaces reconfigured by new construction. All
work is to match existing. Coordinate with architect and owner on any conflicts
that may arise in the field.
5. There are no engineered electrical drawings provided for this project.
Architectural drawings have been provided to show intended use of the space.
Contractor shall be responsible for re-wiring existing light fixtures, switches,
outlets and miscellaneous devices outside the scope of this project that are re-
configured by the new construction. All circuits are to be labeled at the panel
in a clear/legible manor. Coordinate with architect any additional required work
not shown here, or any conflicts that may arise in the field.
E�. Architectural drawings shall take precedence over other trades' drawings when
conflicts arise. Bring conflicts or inconsistencies between architectural
drawings and other disciplines to the attention of the architect prior to bid,
order and installation.
7. Existing hard duct to remain as is. No new ductwork required. Re-work flexible
duct to new diffuser locations.
8. Carson Design Associates Inc. does not have charge or responsibility for the
design or installation of systems executed as design build or otherwise
executed with others.
Note: E.C. and/or design build contractor is to verify that project meets Indiana
ASHRAE 90.1 energy codes. Design intent is to be within watts per square foot. Provide
e�nergy managment controls, such as sensor controls (ultrasonic and motion detection)
�nd/or relay time clocks, as required by the code.
Indiana required energy compliance report (ComCheck) is the responsibility of the
c>wner or owner's representative. Drawings, specifications and energy control devices
a�re shown with the intent of ineeting current state energy codes. Submitting party is to
a�lert designer and owner of any additional devices or load changes necessary to
z�dhere to the code prior to submission of ComCheck.
�� REFLECTED CEILING PLAN KEYED NOTES
1 Align new 2x2 ceiling grid to match exsiting with existing 2x2 ceiling grid.
2 Span ceiling grid as shown or as required to accomodate one full tile.
3 Demolish existing ceiling grid, tiles, and lighting devices in expansion area.
4 Patch/repair existing ceiling construction to return to like new condition.
;
,.
�
.,
;i
, � ��
, �;
'/��' , ,"':..-
� �
�
��� � ���
� � �
yie,�
�y �, ;� �� �` ,y � �
�"'�"`�� �,� � ��� � � � , � ,,,�
�
O
�
�
�
■�
V � �-' z
� _ �
� � � O v_i
= i � c� o
■� � , � �
LL= w�'�
� �
� � � �
_ � O �
� � M
�
■�
L
�
�
STAM P ���,.�,�,�.,, .
• N '•
.�'�'C`��• Y••:9<�,�'�.
.,,���. ���G�STERFO,����,,:
: No. :
: :11200176: :
i STATE OF �
,��i�,,���•. �ND �AN P .� � ,,,���,
•,���4�H �� ��G ��.
�� t \ • t����
05/01/13
ISSUE: 0
Tenant Review 05/01/13
DRAWING TITLE:
Reflected Ceiling Plan
JOB NO. 11227707
DATE: 05/01/13
SHEET NUMBER:
A202
COPYRIGHT 2013 CARSON DESIGN ASSOCIATES