Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A310 WALL SECTIONS (CONT)
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: Ca r m e l C i t y C e n t e r Bu i l d i n g D Ca r m e l , IN 46 0 3 2 85 0 S o u t h R a n g e l i n e R o a d COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date EJD, JLS, JAW, AJR JAW PEDCOR DESIGN GROUP LLC NASH BUILDING A310 WALL SECTIONS (CONT) Bid Set 05.15.2012 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013 JAMES R. STUTZMAN, AIA, Carmel, Indiana. Construction Documents OF 140SHEET 69 5 1 F E D C B A 5 4 3 2 1 4 3 2 F E D C B A • Construction Bid Set 02.20.13 • Parcel 9-54 Bid Package Parking Garage and Ramp 02.20.13 E R 282216 H 11 SCALE: NTS PLAN NORTH KEY PLAN BLDG D alldata:MS:DESIGN:PROJECTS:CARMEL CITY CENTER:CCC Drawings:CCC Construction Doc:Building D:D.CAD:D.Shell:Bldg D Nonseparated.pln, Date printed: 8/12/13 State Release Set 02.20.13 PR - CCC.D-BLD.PR.001 08.12.13 STATE RELEASE SET E2 A503 E5 A505 F5 A505 C2 A501 4' 2' 30 ' 2' - 1 " 9" GUARDRAILING ASSEMBLY 6 BEYOND, SEE A512. 1-1/2" AIR SPACE. BRICK VENEER REINFORCED CONCRETE WALL W/ RUBBED CONCRETE FINISH, REF. S-SERIES DRAWINGS. TRENCH DRAIN. SEE CIVIL DWGS. 6" REINFORCED CONCRETE SLAB OVER 9" MIN. GRANULAR FILL , REFERENCE S- SERIES DWG & SOIL REPORT . REINFORCED CONCRETE FOOTING, REFERENCE S-SERIES DRAWINGS. OVERHEAD COILING DOOR LIQUID APPLIED MOISTURE MEMBRANE, TYP. 6" REINFORCED CONCRETE RAMP OVER 12" MIN. GRANULAR FILL , REFERENCE C- SERIES DRAWINGS. J-BOX FOR DOOR CONTROL. COOR. SIDE LOCATION WITH DOOR SUPPLIER.3x3 PAINTED STEEL TUBE PEDESTAL W/ 12"x12" BASE BOLTED TO CONCRETE BASE FOR CARD READER BOLLARDS 3/4" CONDUIT UP THROUGH PEDESTAL TO SENSOR DIMENSIONAL FIBERGLASS ROOF SHINGLES ON 15 # FELT. ROOF SHEATHING, REFERENCE S-SERIES DRAWINGS PREFINISHED METAL DRIP EDGE WOOD ROOF TRUSSES, REF. S-SERIES DWGS. STUD WALL W / 5/8" EXT. SHEATHING PER S- SERIES DWGS., TYP. R25HD BATT INSUL. W / KRAFT FACE, TYP. 5/8" DRYWALL R-11 BATT INSUL., TYP. (1) LAYER 5/8” GYP. TYPE C, AND RESILENT FURRING CHANNELS ON BOTTOM OF TRUSSES. SEE UL DESIGN P522 R-11 BATT INSULATION 5/8" DRYWALL R21HD BATT INSUL. W / KRAFT FACE, TYP. 1 1/2" LT. WT. AGG. CONC. TOPPING ON KRAFT PAPER OVER T&G SUB- FLOOR ON WOOD FLOOR TRUSSES. 5/8" DRYWALL R21HD BATT INSUL. W / KRAFT FACE, TYP. 1 1/2" LT. WT. AGG. CONC. TOPPING ON KRAFT PAPER OVER T&G SUB- FLOOR ON WOOD FLOOR TRUSSES. GUARDRAILING ASSEMBLY 6 BEYOND, SEE A512. COPPER FOUNDATION FLASHING. BRICK BASE OVER 8" CMU, GROUT SOLID BETWEEN TRENCH DRAIN AND THICKENED SLAB, REF. CIVIL DWGS. CORNICE 1: EIFS CORNICE 2: INCLUDES 2X WD FRAMING, PLYWD, SOFFIT, VENTS, PREFIN MTL CAP/TRIM/4x6 GUTTER INSUL., SEE ATTIC PLAN RATED CEILING PER U.L. ASSEMBLY #L516, REF. C5/A501 & E5/A501 RATED CEILING PER U.L. ASSEMBLY #L516, SEE SHT. A401 -12'-3" -1 PARKING LEVEL ±0" 1 FIRST FLOOR +14' 2 SECOND FLOOR +25'-1" 3 THIRD FLOOR +34'-1" 4 B.O. TRUSS +43'-1" 5 ROOF 3 1/2" CONC. TOPPING OVER 2 1/2" EXTRUDED POLY- STYRENE BOARD OVER 10" PRECAST PLANKS A2 A501 E2 A503 B2 A504 B2 A504 B1 A604 C5 A604 C4 A604 1-1/2" AIR SPACE. BRICK VENEER REINFORCED CONCRETE WALL, REFERENCE S-SERIES DRAWINGS. 6" REINFORCED CONCRETE SLAB OVER 9" MIN. GRANULAR FILL , REFERENCE S- SERIES DWG & SOIL REPORT . REINFORCED CONCRETE FOOTING, REFERENCE S-SERIES DRAWINGS. VOLCAY WATERPROOFING CONT. TO BTM. OF FOOTING LIQUID APPLIED MOISTURE MEMBRANE GUARDRAILING ASSEMBLY 6, SEE A512. S.H. WINDOW. LIMESTONE SILL PANELPART OF LIMESTONE WINDOW SURROUND 1, SEE E5/A511 EIFS WINDOW HEAD 1 OVER MASONRY VENEER. DO NOT CONCEAL WEEPS. SEE F1/A511 GUARDRAILING ASSEMBLY 6, SEE A512. S.H. WINDOW. LIMESTONE SILL PANEL, PART OF LIMESTONE WINDOW SURROUND 1B, SEE E5/A511 YORK THRU WALL FLASHING. LOOSE LAID STEEL LINTEL, PAINTED. STOREFRONT SYSTEM. YORK HEAD FLASHING. SELF SUPPORTING LIMESTONE HEAD, PART OF LIMESTONE WINDOW SURROUND 1, SEE E5/A511 DIMENSIONAL FIBERGLASS ROOF SHINGLES ON 15 # FELT. ROOF SHEATHING, REFERENCE S-SERIES DRAWINGS PREFINISHED METAL DRIP EDGE AND EIFS CAPPING. REFER TO EIFS DETAILS AND PROFILE SHEET FOR TYPICAL REQUIREMENTS. PREFINISH METAL LEDGE CAP AND FLASHING OVER ENTIRE BALCONY ASSEMBLEY DIRECT APPLIED FINISH SYSTEM SOFFIT 4" CMU BEHIND BALCONY ASSEM. BALCONY FRAMING ATTACHED TO MASONRY, REF. S-SERIES DRAWINGS DIRECT APPLIED FINISH SYSTEM SOFFIT 4" CMU BEHIND BALCONY ASSEM. BALCONY FRAMING ATTACHED TO MASONRY, REF. S-SERIES DRAWINGS WOOD ROOF TRUSSES, REF. S-SERIES DWGS. WOOD WINDOW HEADER, REF. S-SERIES DWGS., TYP. R25HD BATT INSUL. W / KRAFT FACE, TYP. 5/8" DRYWALL R-11 BATT INSUL., TYP. 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS @ 12" oc PER U.L. ASSEMBLY #L563. (1) LAYER 5/8” GYP. TYPE C, AND RESILENT FURRING CHANNELS ON BOTTOM OF TRUSSES. SEE UL DESIGN P522 R-11 BATT INSULATION 5/8" DRYWALL R21HD BATT INSUL. W / KRAFT FACE, TYP. 1 1/2" LT. WT. AGG. CONC. TOPPING ON KRAFT PAPER OVER T&G SUB- FLOOR ON WOOD FLOOR TRUSSES. WOOD WINDOW HEADER, REF. S-SERIES DWGS., TYP. 5/8" DRYWALL R21HD BATT INSUL. W / KRAFT FACE, TYP. 1 1/2" LT. WT. AGG. CONC. TOPPING ON KRAFT PAPER OVER T&G SUB-FLOOR ON WOOD FLOOR TRUSSES. COPPER FOUNDATION FLASHING. WATERPROOF MEMBRANE. YORK THRU WALL FLASHING AND PREFIN. MTL. COUNTER FLASHING CONT. ACROSS BALCONY. YORK THRU WALL FLASHING AND PREFIN. MTL. COUNTER FLASHING CONT. ACROSS BALCONY. SIM. PREFINISH METAL LEDGE CAP AND FLASHING OVER ENTIRE BALCONY ASSEMBLEY WOOD WINDOW HEADER, REF. S-SERIES DWGS., TYP. CORNICE 1: EIFS, INCLUDES EIFS DENTIL 1 CORNICE 2: INCLUDES 2X WD FRAMING, PLYWD, SOFFIT, VENTS, PREFIN MTL CAP/ TRIM/4x6 GUTTER TRIM 5: INCLUDING EIFS, AND PLYWD CAP SUBSTRATE TRIM 4B: INCLUDING EIFS, AND PLYWD CAP SUBSTRATE 3 1/2" CONC. TOPPING OVER 2 1/2" EXTRUDED POLY-STYRENE BOARD OVER 10" PRECAST PLANKS INSUL., SEE ATTIC PLAN -12'-3" -1 PARKING LEVEL ±0" 1 FIRST FLOOR +14' 2 SECOND FLOOR +25'-1" 3 THIRD FLOOR +34'-1" 4 B.O. TRUSS +43'-1" 5 ROOF 5/8" F.R. GYP. BD. TYPE 'C' ON RESILIENT CHANNELS @ 12" O.C. PER U.L. TEST #L563 F2 A503 6" SOCKED DRAINAGE TILE SURROUNDED BY 6" OF CLEAN GRANULAR FILL. SEE DETAILS A2/A501 & C1/A95. A2 A501 E2 A503 F5 A505 B4 A604 B5 A604 F5 A604 B4 A604 2' 30 ' 2' - 1 " REINFORCED CONCRETE WALL, REFERENCE S-SERIES DRAWINGS.6" REINFORCED CONCRETE SLAB OVER 9" MIN. GRANULAR FILL , REFERENCE S-SERIES DWG & SOIL REPORT . REINFORCED CONCRETE FOOTING, REFERENCE S-SERIES DRAWINGS. VOLCAY WATERPROOFING CONT. TO BTM. OF FOOTING DIMENSIONAL FIBERGLASS ROOF SHINGLES ON 15 # FELT. ROOF SHEATHING, REFERENCE S-SERIES DRAWINGS PREFINISHED METAL DRIP EDGE AND EIFS CAPPING. REFER TO EIFS DETAILS AND PROFILE SHEET FOR TYPICAL REQUIREMENTS. 1-1/2" AIR SPACE. BRICK VENEER LIQUID APPLIED MOISTURE MEMBRANE, TYP. S.H. WINDOW. LIMESTONE WINDOW SILL, SEE F3/A511. YORK HEAD FLASHING. LOOSE LAID STEEL LINTEL, PAINTED. S.H. WINDOW. BRICK BASE AND SILL OVER 8" CMU, GROUT SOLID BETWEEN BRICK AND LIMESTONE JACK ARCH 1, SEE D1/A511 YORK HEAD FLASHING. LOOSE LAID STEEL LINTEL, PAINTED. S.H. WINDOW. LIMESTONE WINDOW SILL, SEE F3/A511. WOOD ROOF TRUSSES, REF. S-SERIES DWGS. WOOD WINDOW HEADER, REF. S-SERIES DWGS., TYP. STUD WALL W / 5/8" EXT. SHEATHING PER S- SERIES DWGS., TYP. R25HD BATT INSUL. W / KRAFT FACE, TYP. 5/8" DRYWALL R-11 BATT INSUL., TYP. 5/8" FIRE RESISTANT GYP. BD. ON RESILIENT CHANNELS @ 12" oc PER U.L. ASSEMBLY #L563. (1) LAYER 5/8” GYP. TYPE C, AND RESILENT FURRING CHANNELS ON BOTTOM OF TRUSSES. SEE UL DESIGN P522 R-11 BATT INSULATION 5/8" DRYWALL R21HD BATT INSUL. W / KRAFT FACE, TYP. 1 1/2" LT. WT. AGG. CONC. TOPPING ON KRAFT PAPER OVER T&G SUB- FLOOR ON WOOD FLOOR TRUSSES. WOOD WINDOW HEADER, REF. S-SERIES DWGS., TYP. 5/8" DRYWALL R21HD BATT INSUL. W / KRAFT FACE, TYP. 1 1/2" LT. WT. AGG. CONC. TOPPING ON KRAFT PAPER OVER T&G SUB- FLOOR ON WOOD FLOOR TRUSSES. SIM CORNICE 1: EIFS CORNICE 2: INCLUDES 2X WD FRAMING, PLYWD, SOFFIT, VENTS, PREFIN MTL CAP/ TRIM/4x6 GUTTER 3 1/2" CONC. TOPPING OVER 2 1/2" EXTRUDED POLY- STYRENE BOARD OVER 10" PRECAST PLANKS INSUL., SEE ATTIC PLAN RATED CEILING PER U.L. ASSEMBLY #L529. COPPER FOUNDATION FLASHING BRICK AND LIMESTONE JACK ARCH 1, SEE D1/A511 -12'-3" -1 PARKING LEVEL ±0" 1 FIRST FLOOR +14' 2 SECOND FLOOR +25'-1" 3 THIRD FLOOR +34'-1" 4 B.O. TRUSS +43'-1" 5 ROOF 6" SOCKED DRAINAGE TILE SURROUNDED BY 6" OF CLEAN GRANULAR FILL. SEE DETAILS A2/A501 & C1/A95. SCALE: 3/8" = 1'-0"2 WALL SECTION SCALE: 3/8" = 1'-0"3 WALL SECTION 4 PERSPECTIVE SCALE: 3/8" = 1'-0"1 WALL SECTION