Loading...
HomeMy WebLinkAboutMechanical Plan M1� ��...._..,. _ _ � ' �/ � � � L� , // '' ' ' RTU 2 ���� �� ( ��� ���� I/4��� ��_��� 2 H � O z EGONOMI Z�R RAINHOOD WP GFI REG�PT�tGL� �I ELD-SUPPLI � DISGONNEGT SWITGi-f GONTROL WIRING THROUGH GURB. GOND�NS,'4T� TRAP - SPL/4SH BLOGK EQUIPMENT SCHEDIJLE RTU I 8 2= 120,000 BTU NATURP�L GAS HEf4TING WITI-I 5 TON ft/G E EGONOMIZ�RS. O.A. @ 20% MAX. ROOPTOP UNITS. INSTALL SUPi�LY E RETURN DUGT DROPS INTO SPftGE FOR FUTURE TENANT. LI N� SUPPLY DRIP POGKET z z � F f in � .0 r MANUAL SHUT O� VALVE WITi-f I/8" N.P.T. PLUGGED TltPPING, AGGESSIBLE �OR TEST GAUG� GONNEGTION MUST BE INSTALLED I MM�DI ATELY UPSTREftM OF Tt�tE GAS SUPPLY GONN�GTION TO THE APPLI ftNGE. GROUND JOINT UNION PIP� TO GONTROLS PLUGGED I/8" N.P.T. T�ST GAG� GONNEGTION GAS PIPING CONTROLS NOT TO SCALE / ROOFTOP UNIT � � I � [3i7�7�r!�:�� 7 / ISUPPL7 AIR DUGT Q�-( 5� �� .�0� ����� > ���;� / 5 I � �DRIP LEG � RETURN AIR � SYST�M SENSOi2 MODEL #DH400AGDG SMOIC� D�TEGTOR �T SHRLL BE FURNISfi�D WITH UNIT /4S SHOWN ON DETAIL. DETEGTOR HEAD St-tALL BE # 1451 DH I ONI ZATI ON TYPE, � Si°tMPLING TUB�S, REPLftG�MENT PILT�RS AND R�LAY TO SHUTDOWN FAN P�S PER UL 268h. TO POWER SUPPLY GONTROL WIRING TO INDOOf2 TtiERMOSTAT MAJOR INSTALLATION REQUIREMENTS NOT TO SCALE M�GHANIGAL GENERAL NOTES: I. MEGHftNIGAL GONTRftGTOR TO �URNISH ALL LASOR, MAT�IRL, AND EQUlPMENT REQUIRED �OR THE GOMPLETION E OP�RftTION O� ALL SYSTEMS IN THIS SEGTION O� WORK. ALL MEGiiANIGAL WORK SHALL B� IN STRIGT AGGORDANGE WITH INDII�NA MEGHANIGAL GODE ({.M.G.), LAT�ST EDITION lNGLUDING ADOPT�D INDIANA AMENDMENTS, ASHRA�, SMAGNA, NFPA AND �PA. THE APPLIGftBL� PORTiONS O� Tti� SPEUFIGl4TIONS ARE INGLUDED AS Pf4f?T O� THIS SP�GI�IGATION. ALL INSTALLRTIONS SHALL B� PER�ORMED IN A GOOD WORKMANLIK� M/4NNER. 2. INSTftLL l4LL GAS FIRED FURNAC�S IN STRICT AGGORDANCE WITH MANUPAGTURER'S WRITTEN INSTALLATION INSTRUGTIONS At�D NFPA 54. 3. GAS PIPING SHALL B� O� BLAGK STEEL PIP�, ASTM A53, A105, OR f�l2p. PIPING SHALL BE SGHEDULE 40. I P ALLOWED BY LOG,°tL. GOD� GONTRAGTOR M1�7 US� GQRRUGrqTED STl41NL�SS ST��L TUBING (GSST). GAS PIPING IN GONTAGT WITH THE GROUND SHALL B� GOItTED WIThi F/4GTOR7 INSTALLED POLYETf-f7LENE TAPEOF 20 MI� THBGKNESS. GhS GOGKS, 2" AND SMALLER, SIiALL �E 150 PSI W.O.G. Bi20NZE BODY. US� THREAD�D JC�INTS AND �ITTINGS FOR 2" ,4R1D SMALLER PIP�, UNIONS TO B� GROUND JOINT �! i TINGS, W�LD�D JOiNTS FOR L/4RGER PIPE. INST,hLL GA5 �'IPING IN STRIGT AGGORDANG� Wii�f N�P,'t-54, NftTIONAL �L GfrS GOD�. Dt� NOT iNSTAL� GAS PIPING IN GONGEALED SP/4GES, WITHOUT AP,-''RQVAL O� GOVERNING AUTHORITI`. 1►vSTALL SHUTOF� GOGKS SEDIMENT TRAPS, ftiND UNlONS AT A�LL �QUI PMENT I TEMS. BOND SYSTEM TO A GROUNDI NG ELEGTRODE i N,�GGORDANG� W I TH N�PA-�O. PIPING SIZEQ AS SHOWN, HANGERS ShiALL B� MINIMUM O� !/4" THi?�AD�D ROD WIThi SADDL�S @ 6'-O" APART. GAS Nf�TER LOG,�tTION IS ASSUMEp ANU Sf-fALL B� GOORDINATED W;TH LOGl�I.. UT!UT'�. 4. ALL PIPING, DUGTS, V�IVTS, �TG., EXi�NDING THROU6H WALLS AND ROO� SHALL S� �LASHED, GOUNT�R �LASHED IN A f�IftT�RPROOF MANNER. 5. ALL DUGTWOilK INSULATIC�N SF1AL� BE RUN GONT!NUOUSLY THRUUG�! �LOORS, PA�`vTiTIONS, ROOF STRUGTURE AND U�GK. 6. ALL PIPING AND DUGTWORK LOGATIONS Sf°fALL BE GOORDINATED W/WORK UNDER OTH�i? DIVISIONS O� Ti-fE SP�GIPIGATIONS, TD AVOID INTER�RENGE. GOORDi1�fAT� WITH ftLL OT�1ER TRAD�S PR10R TO PURG1-fA51NG OR INST,�LLING �QUIPMENT AND MAT�RI,�LS. 7. METAL DUGTWORK SHALL GOMPLY WITFi SMAGMA, "tiVAG DUGT GONSTRUGTlON STANDA�ZDS, METAL /4ND �LEXIBLE." GOMPLY WITH ASHRAE HRNDBOOK �OR INr-a'TALLPcTION OF METRL DUGTWORK. ALSO GOMPLY WITH N�rPA 90A. ALL TRUtvK M�TAL DUGTWORK SHALL BE WRftPPED WITH II/2" �OIL BAGK INSULATION OR PROVID� I" FIBERGLASS DUGT BORRD WiTH PROPER SIJPPORTS OR INT�RNAL LINING WIT1-f I" PIB�RGLASS DUGT INSULATION. ftLL GOVERING AND LIiV�RS INGLUDIIvG ADH�SIVES SHftLL HAVE A�LAM� SPREAD RA71NG NOT MORE THAN TW�NTY-�IVE {25) AND SMOKE-DEVELOPED RATING NOT MOR� THAN FIFT7 (50) WHEN TESTED IN AGGORDRNG� WITti ASTM-E-B4. /4LL SQUAR� ELBOWS SHALL HAV� AI��OIL TYPE TURNING VANES. PROVIDE VOLUM� GONTROL DAMPEi2S AT ALL BRftNGI-f DUGTS TO DI�IJSERS AND A MAXIMUM OF 5 PEET ABOVE THE G�ILING. ALL DUGTWORK SHRLL BE GALV. SH�T MET,'4L E SHALL B� GONSTRUGTED E INSTALLED IN AGGORDANG� WITH SMAGMft T D STANDARDS. DUGT SIZFS SHOWN Ai2E PI�T �REE AR�A. INGR�RSE R�GT�kNGULRR Sfi��T METAL DUGT SlZES SY TWO TIMES Tf� THIGKPIESS OF INSUL1tTION. 8. MftXIMUM �L�CISLE DUGT L�TIGTI-I SHALL BE 10'-O". ALL FLEXIBLE DUGT SHALL GONPORM TO THE REQUIREM�NTS O� UL 181 �OR GLASS I PLEXIBL.� AIR DUGTS. SIJPPORT TO �LIMINATE SAGGING E KINKING. 9. SUPPORT DUGTS RIGIDL7 PrT INTERVALS NOT EXGEFDING T�N (10) PEET WITH SUITABL� G,'4LVANIZ�D TI�S AND PAST�TIERS �OR Ti�i� SIZ� O� DUGT, AND RUN IN N�AT, STRAIG�iT LINES, TIGHT TO STRUGTUR�S OR WALLS. DO NOT OBSTRUGT USABLE SPAGE. WH�RE DUGTS PRSS THROUGH WALLS, �LOORS, G�ILINGS, �TG., PROVIDE FLANGES AND ftPPROPRIAT� S�ALING NfETHODS TO MRINT1hIN INT�GRIT7 O� SURFAGE P�NETRATED AND PROVID� R �INISH�D APPERRANGE. PROVIDE PROTEGTION B/4RRIERS TO �XPOSED DUGTS T�tftT Mh7 B� MEGHl4NIGAL DftMAGE B7 VEHIGLES, OR �ROM OTHER GAUSES. PROVIDE FIRE STOPP►NG A�S REQUIRED FOR PIRE RAT�D PENETRATIONS. 10. ,'4LL HVAG EQUIPM�NT TO B� INST,�4LLED P�R MFG. REQUIREMENTS AS SHOWN. UTILIZE �,�4GTOR7 �ILTERS DIJRING GONSTRUGTION E REPLftGE W/ R�PLAGEftSLE MEDIA IN METAL �ILTER FRtlME JUS7 PRIO� TO T�ST E BALANGE E AT TIM� BUILDING IS TURNED OVER TO Tf�i� OWNER. GOORDIPfAT� WITH Tti� OW1�R. II. PROVIDE PLE?CiBLE GONNEGTIONS hT ,�LL EQUIPMENT FOR SOUND ftND VIBR,hTION lSOVtTION. 12. I NSTALL MFTAB�STOS DDUBL� LI N�D FLIJ�, SI Z� AS REGOMMENDED BY MANIJ�,AGTURER, UP THROUGH ROO�. UNLESS A{30� ��FIGIENT FURNftGE IS USED, i i�i�N PVC PIPfNG WfLL BE RUN AS R�GOMMENf?�D B7 TI-fE MANIJFRGTUR�i'.. 13. M/41NTAIN MIN. IC' BETWE�hi OUTDOOR AIR INTAlGES RND �XHAUST F�N afSGHARGE, PLUMBiNG, V�NT, ETG. 14. INSTALL AGG�SSORY ITEMS, SUGN AS THROUGH TH� WALL UNITS, hliZ GLEANERS, HUMIDI�IERS, ETG. IN STi�IGT AGGORDANGE WITH MANUFAGTURER'S PRINTED IN5TRUGTIONS. 15. PROVIDE AND IMSiftLL ALIs GG'ND�NS,�TE DRAIN LIAIES �ROM HUMIpIFIERS AND GOOLING GOILS AS R�QUIi2ED. TT�fiMINAT� ALL DRAIN LINES OVER OPEN SIGHT DRAINS, �LOOR DRAINS OR ROOF DRAINS WITi-t A MIN. OF 6" AIR GAP. 16. THERMOSTAT WIRING AND LOGATION: THERMOSTAT MUST BE MOUNTED ON R V�RTIGAL VIBRATION-�R�E SI�FAG� �R� �ROM AIR GURRENTS AND IN AGGORDANGE WITH TH� RJRNISHED INSTRUGTION. MOUNT THE THERMOSTAT APPROXIM�,TELY 5�EET (1.5M) RBOV� THE �LOOR AREA WHERE IT WILL B� EXPOSED TO A PREE GIRGULATION O� AVERi4GE T�MPERl�TUR� AIR, ALWA7S REFER TO THE THERMOSTAT INSTRUGTIONS AS WELL AS UNIT W I RI N6 DI AGRAM AND W I R� AGGORDI NGLY. AVOI D MOUNTI NG TH� TI-{ERMOSTAT I N Tf-fE �OLLOWING LOGATIONS: GOLD AR��tS - OUTSID� WALLS OR ARE,�4S WHERE DR,4PTS MAY AFFEGT T1-fE OP�RATION O� TI-!� GONTROL. f-fOT AREAS -/4REJtS WI-f�RE Tf�i� SUN'S i2AYS, RADIATION OR WARM AIiZ GURRENTS MA7 A�GT GONTROL OPERATION. DEAD AR�AS - /4REAS WHERE AIR GANNOT GIRGULATE �REELY, SUGI-f hS B�HIND DOORS OR IN GORNERS. 17. GONTRAGTOR StiALL VISIT ThfE JOB SITE ,4cND �E �AMILIAR WITH ALL PR0.IEGT GONDITIONS PRIOR TO FABRIGATING ftN7 EQUIPMENT, DUGTWORK, ETG. NO ALLOWI�NGES WlLL B� MADE FOR GONTRAGTOR UNPAMlLIARITY WITH PRD.�GT GONDITIONS. 18. MEGI-IANIGftL GONTR/lGTOR SHALL BRLANG� 57STEM TO WITHIN IOX D� AIR G2U,'tNTITI�S INDIGATED ON PLANS RND PROVID� OWIVERS iZ�PR�SENTATIVE A CAMPL� �f4LANG� R�PORT. 19. ALL �QUIPMENT S�iALL HAV� I-YEAR WARi2l4NTY E GOMPRESSORS SHALL �i/4VE ADDITIONAL 4-7EAR EXTEND�D WARRANT7. 20. ALL GONTROL WIRING E GONDUIT SHALL GOMPLY WITH NEG. 21. PIPE E DUGT ROUTING SHOWN IS SGf-I�MftTIG. f�VAG GONTRAGTOR SHALL PROVID� ftNY ADDITIONAL OFPSETS AND FITTING, iNGLUDING DIVIDED DUGTS, REQUIRED POR PROPER INSTALLATION AND TO MAINTAIN GLEARANGES AS �NGOUNT�RED IN TH� Pi�LD. 22. LIGHT �IXTUR� LOGl4TIONS TAICE PR�GEDENGE OVER DUGT RUNS, DIPFUSER AND GRILLE LOGATIONS. LOGA'fE DI�US�RS AND GRILLES TO AGGOMMODAT� LlGHTING L/4YOUT. 23. DO NOT SGAL� D�tAWiNGS. S� ARGHIT�GTUR�41. DR/EWINGS E REFLEGTED GElLING PVtNS FOR �XAGT LOGATION Or DOORS, WINDOWS, GEILING DI�fIJSERS, ETG. 24. M.G. SHRLL GOORDiNATE THE WORK WITH ALL TRADES INVOLVID IN TH� GEILING WORK TO INSURE GL�ARANGES �OR �lXTUR�S, DUGTS, PIPING GEILING SUSPENSION SYSTEMS, ETG., NEG�SSARY TO MAINT,41N TI-fE �INISi-I�D G�ILING i-fEIGHTS INDIGATED ON ARGHIT�GTURAL DRP�WINGS. 25. ALL NEW PEN�TiZATIONS THRaUGH rLOOR, GEILiNG OR ROO� WILL IiAtY� THE ANNULAR ARi1t B�TWEEN TH� IT�M ,°cND ThtE OPENING SEAL�D AROUND TH� OPENIIJC,-� TL? i�R�VENT TI-kE T'ASSAGE O� �iRE AND SMOiG�. H0�'FIVl�i�l �NClPLE��iS P.C. 8261 BASELINE ROAD PARAGON, iN�Il�i�iA 46165 765-537-29�1 FAX 537-2�92 > steve�hoffma�angine€rs.�m � 0 0 „ � Hoffman Enc�ineers inc. S4ate of Ind'aana�ertificaie af Authori#y # 16188 "{aLOBAL �O�tII�1�ME�iT HViTH A MA@� S7'RE�i A s TiitiDE�� i k i. �, � t � � � N � � � � O W � �� � � � � � � � � � . � � � � � "� � � S�, � CON�T � �'ION �� ��� PR� ��C�,� �� �_ ``�`!`y`1NIi�f f INPO/ ��o Q��� C �OF�`'���i `�� �� ���,1 STE/��� �9 �� . r.� ' No, PE��JC16188 ,� � ° _ - � • � � � � STATE OF �� ` �'oo'C�F.� %NDf AN������� �si `S�ONAL �� �°`� fi N,�� Step e� �a Hof�ma .�ngineer E3V # te�1�8 ',,� ' _ _ �_`,'� J1. �T` _'� -=��=_- � � � � � � �h� _-� � �VI E� I��►t� I �AL � IY r-��'..._�- N:. � � �__�� � �� � LY �_ I.