HomeMy WebLinkAboutLighting and Power EP1010 0 0 n 0 0 / 0 0 � 0 LIGHTING PLAN EP101 SCALE: l(8" =1'-0" POWER PLAN EP101 SCALE:1/8" =1'-0" GENERAL NOTES 1. ALL ELEC,"TRICAL WORK SHALL COMPLY WITH LATEST VERSION OF NATIONAL ELECT'RICAL CODE (N.E.C.) 2. INSTALL �" C AT EACH TELElDATA OIITLET AND STUB UP ABOVE WALLS. 3. MINIMUM CONDUIT SIZE SHAI.L BE �". 4. PROVIDE SHOP DRAWINGS FOR APPROVAL OF THE FOLLOWING" 4.1. LIGHT FIXTURES 4.2. WIRING DEVICFS 4.3. OCCUPANCY SENSORS 4.4. FIRF. Ai.,ARM DEVICES f:l �' , — O `Ob � 0 � EXHAUST FAN 241c24 AIR SUPPLY DIFFUSER 24�4 AIR RETURN GRII "T "F" 24x48 3-TiJBE RECESSED FLUORESCENT FIX'I'URE 8' 2-TUBE SUSPENDED FLUORESCENT FIXTURE cr 12' A.F.F. RECESSED CAN LIGHT (EXISTING) EXIT LIGHT W/ EMERGENCY LIGHTS & BATTERY PACK EXTERIOR EMERGENCY EXIT LIGHT JUNC'I'ION BOX SPRINKLER HEAD OCCUPANCY SENSOR SCHEDULE . RS SHOWN BY "SCHNEIDER ELECI'RIC" Vi� � `�i� �S D/T WALL MOUNTED PIR #SLSPWS1277AW CEILING MOUNTED PIR #SLSCPS1000 (SENSOR) #SLSPPl27? (POWER PACK) CEILING MOUNTED ULTR�SONIC PIR #SLSCUS2000 (SENSOR} #SLSPPl277 (POWER PACK) CEILING MOUNTED DUAL-TECHNOLOGY #SLSCDS2(�0 (SENSOR) #SLSPP1277 (POWER PACK) LIGHT FI�TURE SCHEDULE FA FB FC FD FE X EM NUI..TTE #F2-328T5-UNV-PSN NULITE #WA-228T5-UNV-PSN NULIT'E #BW-228T5-UNV-PSN-WH-UP JUNO #CV6-126Q-600C NULITE #I-12-228T5-LJNGPSN EXITRONIX #VLED-U-WH-EL40 EXITRONIX #LED-9(} POWER PLAN LEGEND q �U EXISTING PANEL (SEE NOTE) 120VAC DUPLEX OUTLET (18" A.F.F. UNLESS NOTED) a TELEPHONE STUB-IN (FIELD VERIFY EXACT LOCATION) O JUNCTION BOX �- DISCONNECT � L'(;� ��GL�'^iC �°�(,'u� �C7�,�E;kt ELECTRICAL SPECIFICATION N�TES 1. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) AS ADOP'TED BY THE INDIANA STATE BUILDING COMMISION. 2. USE GROUND FAULT INTERRUPT'ER RECEPTACI�FS IN AI,I, I.00ATIONS REQUIRED BY THE NEC, TOILET ROOMS, AND WHERE INDICATED ON DRAWINGS. 3. FURNISH DISCONNECT SWITCHES AT ALL HVAC & PLUMBING EQUIPMENT AND AS INDICATED ON DRAWINGS. 4. GROUND ELECTRICAL EQUIPMENT AS REQUIRED BY NEC. 5. TEST ALL CIRCUITS FOR CONTINUITY, SHORTS & GROUNDS. REPLACE ANY CIRCUITS FOUND DEFECTIVE. 6. PANELBOARD LOADS SHALL BE BALANCED WITHI1�110 PERCENT FOR ALL PHA3ES. 7. INSTALL UNDERGROUND CONDUIT A MINIMUM OF 18" BELOW FINISHED GRADE_ 8. ELECTRICAL CONTRACTOR SHALL PAY FOR ALL PERMI'TS AI�TD INSPECTIONS AND PROVIDE CERTIFICATE OF INSPECTION. 9. ELECTRICAL CONTRACTOR SHALL VERIFY UTILITY CO. REQUIREMENTS AND CHARGES PRIOR TO BIDDING AND INCLUDE COST OF SAME IN BID. 10. ELECI'RICAL CONTRACTOR SHAI.L PROPERLY WIRE Ai "i " EQUIPMENT INCLUDING TENANT SUPPLIED EQUIPMENT AND EQUIPMENT SUPPLTED BY OTHER TRADES. 11. CIRCUIT NUMBERS SHOWN ARE FOR GROUPING ONLY AND NOT ACTL7AL CIRCUIT NUMBERS. CONNECT TO CIRCUITS IN EXISTII�IG PANEL. 12. CONNECT NEW FIRE AI_ARM DEVICES TO EXISTING BUII.DING FIRF AI.,ARM SYSTEM. ELECTRICAL EQUIPMENT CONDUIT: DISCONNECT SWITCHES: IIVSIDE BUILDING - EMT SQUARE'D' GENERAI, DUTY OUTSIDE BUILDING - PVC TYPE WITH NEMA I OR NEMA 3R ENCLOSURE AS REQUIRED FOR CONDUCTORS: �rrLicaTTOrr COPPER THHN OR THWN SWITCHES: HUBBEL NO. SINGLE POL,E -1221 3-WAY -1223 4-WAY - 1224 RECEPTACLES: HUBBEL NO. SINGLE - 5351 DUPLEX - 5352 PANELBOARDS: SQUA.RE'D' NQOD WITH BOLT ON CIRCUIT BREAKERS MIN INTERRUPTING CAP. 10,OOOA BASEBOARD HEATER: BERKO 2514W (4F'T.,120V) W/ SINGLE PULL STAT #TAlAW FIRE PROTECTION NOTES THE EXISTING SPRINKI.,ER SYSTEM MAIN LINES ARE TO STAY INTACT. THE I..ANDLORD'S CONTRACTOR SHALL MODIFY THE EXISTING DROPS AS REQUIRED� � ��� TO SUTT TI-iE NEW LAYOUT. THE LANDLORD'S CONTRACTOR SHAI.I, SUBMIT FOR TI-IE PERMTI'. j � � ��v✓� l � „� � � i er^y K. '�-0 KEYED PL�T NOTES 1. INSTALL ONE (1) 30A-3P C.B. AND OIVE (1) 20A-2P C.B. IN EXISTING PANEL FOR ROOFTOP UNIT AND ELECTRIC WATER HEATER. NEW BREAKERS SH 1I.I.. BE COMPATIBLE WITH EXISTING PANEL. 2. 30A, 208V-3f� CONNECTION FOR ROOF TOP UMT. CONNECT TO 30A-3P C.B. IIv EXISTTNG PANEL. INSTALL 3-#10,1-#10 GND IN A�" C. 3. 20A,, 208V-19S CONNECT'ION FOR ELECTRIC WAT'ER HEAT'ER. CONNECT TO 20A-2P C.B. IN EXISTING PANEL. IIVSTALL 2-#12, i-#12 G1VD IN A�" C. 4. INSTALL 2-COMPARTMENT TELE-POWER POLE FOR POWER AND I)ATA FEEDS TO MODUI.AR FURNITURE. PROVIDE ONE (1) 20A CIRCUIT PER WORKSTATION. TELE-POWER POLE SHALL BE SIMILAR TO'WIREMOLD' #25DTC-4. PROVIDE AI.L NECESSARY COMPONENTS FOR A COMPLETE SYSTEM. 5. POWER CONNECTION FOR MODULAR FURNITURE. PROVIDE ONE (1) 20A CIRCUIT PER WORKSTATION. 6. TELE/DATA CONNEC'I'ION FOR MODUI.AR FURNITURE. FINAL CONNECI'ION AND CABLE BY OWNER_ INSTALL 1" CONDUIT IN WALL AND STUB-UP ABOVE CEILING. 7_ DEDICATED CIRCUIT FOR MICROWAVE OVEN. 8. DEDICATED CIRCLTIT FOR COFFEE MAKER. 9. 20A, 120V-1� MOTOR CONNECTION FOR EXHAUST FAN. EXISTING METER BASE AT EXISTING � CT WIREWAY METER SET � a BY UTILITY � X3 W EXISTING PANEL 1201208V, 3-PH, 4-W, 200A,, 24 CIRCUITS NOTE: EXISTING PANEL VERIFY THAT PANEL IS 200A; IF NOT, INSTAi •T" NEW 200A PANEL 4-#3/0, 1#4, 2"C. � � GROUNDING — PER NEC ELECTRICAL RISER DIAGRAM SC: NONE � a� � � ��� � � � E A � Q �� �. �� � � � 8 �i , ` � 0 .� 'S v � H � � o z°o J (� N m ---I W � ~ Q�m�� � Zp�p� � ���o� � � ��Q S w}-Zwz � l—�ZQ �� JQ .%� <C'QO�Z N Q �� Z ����w � ��z�Q �_�U � � O � W � O z� � O � � Q � a�, � � � � rn CD O v� o� � w � ►�n � � � W � � � A `'' zz � � �' E� o o a ° z d i rn � � A � �z � � � � �� r � y � �-,i ^ � � � � �� � .� � O �--�t �— � � Q F � � =- � � C� � � � � � f� Stamp: .......... ��� ��. �� _'- � �' �, = � fi� ', = v�. : 2w�' ''',� = 3 No. - , � � 17006 ' . = . "s STATE OF .,��, ; � , �� �; •�!�?lAN�` '� � - ,, ' �avAi.. �-_- ,, �`��. �• . Issue: STATE ISSUE Date: 3 —19 —13 Project No.: A13329 File No.. Sheet: EP 101