HomeMy WebLinkAboutMechanical and Plumbing MP101; O WH-1 MS-1 LAV-1 LAV-1 U-1 FD-1 O WGl WC-2 E.T.R. �\ �� EWC-1 � E.T.R. E.T.R. LAV-1 LAV-1 WC-1 WG2 FD-1 � Z PLUMBING PLAN MP101 SCALE:1/4" =1'-0" PLUMBING FIXTURE SCHEDULE MARK FIXTURE MANUFACTURER ACCESSORIES/TRIM WAST'E PIPE VENT PIPE SUPP. PIPE WATER CLOSET �MERICAN STANDARD "CADET 3", WC-1 RIGHT HEIGHT, ELOI�TGACTED 3" 2" 1/2" BOWL, & TANK, SEAT, LID, WC-2 CHROME S7'OP VALVE f1ND PIP1NCi. WC-2 SHALL BE ADA COMPLIANT. 1.28 GPF. LAV-1 I�AVATORY SIMILAR OR EQUIVALENT TO FAUCET WITH WRIST BLADES, PROVIDE THE SHROUD/ KNEE 1�2n � AMERICAN STANDARD, ADA 1 1/2" 1 1/2" 1�2„ CW TYPE, SELF RIMMING CONTACT UUARD FOR AROUND WHITE THE DRAIN MS-1 MOP SINK SIMILAR OR GQUIVALENT TO FIAT, MOP BASI N, SQUARE 32"X32", g30 AA SERVICE SINK FAUCET 3�� 2�� 1�2� HW STOCKTON TF?RRAZ0,12" DEEP 1�2 CW WITH b" SS. DROP FRONT EWGl ELEC"TRIC OASIS WATER COOLER OR APPROVED EQUAL �A TYPE, BI-LEVEL 1 1/2" 1 1/2" i/2" CW (HI-LOV� ADA TYPE cWSAL.7L+�-,M�OUNT �Y 111 1 G ADA URINAL SIMILAR OR LQUNALENT TO U-1 AMERICAN STANDt1RD FLUSH VALVE SIMILAR OR "MAYBROOK" l.0 GPF. FLUSHING EQUIVALENT TO SLOAN, URINAL 1 1/2" 1 1/2" 3/4" CW R1M, INTEGRAL STRAINER, �" FLUSH VALVE, 1.0 GPF. INLF�.T SPUD. FLOOR DRIAN SIMILAR OR EQUIVALENT TO FD-1 ZURN, "FD2202", FLOOR DRAIN, 3" INCLUDE "P-TRAP" 3�� OLJTLET ELEC.'TRIC SIMILAR OR EOUIVALENT TO A.O. PRESSURE AND TEMPERATURE WATER 2„ 1/2" CW HEATER SMITH, "DEL", ] 5 GAL.,1 ELEMENT, RELIEF VALVE PIPED TO MOP 2500W, 208V 1QS SINK. WH-1 BAR SINK SIMILAR OR GQUIVALENT TO COLONY SOFT TWO HANDLE BAR 1�2„ HW AMERICAN STANUARD PREVIOR FAUCET, ADJUSTABLE SINK 1 1/2" 1 1/2" 1�2„ CW SS DROP IN; 1'7 4"�c22", SINGLE BOWL STRAINER, CHROME TRAP AND KS-1 STOP VALVES. NOTES: 1. PLUMBING CONTRAC'I'OR SHAI_L SUPPLY AI_I. NECESSARY MATERIAL TO COMPLETE INSTALLATION OF FIXTURES ACCORI)ING TO ALL LOCAL AND STATE CODES_ - � � _ c� v N � Op W � 'aM,� OO � 0 � FlNISHED fL00R SOAP DISPENSER X Q � 0 � PAPER TOWEL DISPENSER O Q �� V � �U� � O�j m w tn a� � MIRROR wa�t aos� FRONT M OO � M MS-1 NOTE: FIXTURES A AI_I. I.INES A EXISTNIG EXISTTNG SA.�IITARY L F1ELD VERIFY SIZE, LOCATION AND FIAW AS REQUIRED ❑ G100 � A-100 :. _._� __8� t_...._ . ___ EF-1 EXHUAST FAN SHALL BE SIMILAR TO GREENHECK, SIXl CFM, FTELD VERIFY EXACT LOCATION. RTU-1 ROOFTOP UNIT. NEW CURB MOUNTED ROOFT GAS-FIRED/ ELECTRIC COOLED. SIMILAR TO TRANE. PROGRAMMABLE ELECTONIC THERMOSTAT, 400CFM OUTSIDE AIR, 1800 CFM TOTAL. PROFICE Z" NATURAL WITH BLACK STEEL PIPING AND AGA APPROVEU STC GASS PRESSURE REDUCING VALUE. EER/ SEER:11.0/ ' CAPACITY: 58,000 BTU. 48 MBH HEATING AT 78% EFFI( �� _� 00 EF-1 UNIT. AS CONIVECTION VALVE. PROVIDE Q. NET COOLING MECHANICAL SCALE: l�4" =1'-0" 5 WASTE AND VENT RISER M101 SCALE: NONE u�an' TOILET ROOM ACCESSORY 4 MOUNTING HEIGHTS IvIP101 SCALE: NONE wA� aos�r SIUE �� i�_1n• LAVATQRY A-100 FD-1 3" SAN WC-2 A-100 Q _.� _ . _ �.1._�, ____. � __ .. _ ___.__...,__�__.,, r-� % i � A-200 "`� r � F ._,��'.r`� �".�"..,��, _TM _ . m _._ H..�� c � �� > A-ZOO �' ` ��....-:� �-.;�.w..-�- � � �. .�__.�.. �_.._ ___ _ ___. __ ; ; . __�_.�_. _ ..:RTU-� 's �TED ELBOW � � � � � ; �. _;; �x` :; � _.___' � A-200 �; � ��"� �T --.°-�_.�� �___-�_�. � ' � � � �i y t1-200 � . A-200 A-200 A-200 r�►z�.�� INSULATED SHEET METAL, SEALED B GENERAL N(JTES AND SPECIFICATIONS C-100 � 0 1. ENGAGE A TAB ENTITY CERTIFIED BY AABC, NEBB OR TABB TO PERFORM TESTING ADJUSTING AND BALANCING REPORT ON TNF. ROOF TOP AIR CONDITIONERS. 2. CONCEALED AIR DUCT EXTERNAL INSULATION AND PLENUM LINER: MINERAL-FIBER BLANKET WITH AN R-VALUE OF b. APPLIES TO STUD10 # I . 3. GAS PIPING SHALL BE CORRUGATED, STAINLESS-STEEL TUBING: COMPLY WITH ANSI/IAS LC 1 OR BLACK STEEL, ASTM A 53/A 53M, BLACK STEEL, SCHEDULE 40, TYPE E OR S, GRADE B. 3.1. TUBING - ASTMA 240lA 240M, SERIES 300 STAINLESS STEEL. 3.2. COATING PE WITH FLAME RETARDANT ACCORDING ASTM E R�. 4. DUCT SEAL SCHEDULE: 4.1 SUPPLY-AIR DUCTS IN PRESSURE CLASSES 2-INCH WG (500 PA) AND LOWER: SEAL CLASS B. 4.2 SUPPLY-AIR DUCTS IN PRESSURE CLASSES HIGHER THAN 2-INCH WG (500 PA): SEAL CLASS A. 43 EXHAUST DUCTS: SEAL CLASS C. 4.4 RETURN-A1R DUCTS: SEAL CLASS B. 5. COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION 5TANDARDS - METAL AND FLEXIBLE" BASED ON INDICATED STATIC-PRESSURE CLASS [INLESS OTHERWISE INDICATED. 6. GALVAMZED SHEET STEEL_ COMPLY WITH ASTM A 653/A 653M. USE G60 GALVAIVIZED COATING. 7. FIBROUS-GLASS DUCT LINER SHALL COMPLY WITH ASTM C 1071, NFPA 90A, OR NFPA 90B; AND WITH NAIMA AH 124, "FIBROUS GLASS DUCT LINER STANDARD." IT SHALL HAVE AN ANTIMICROBIAL EROSION-RESISTANT COATING. 8. EXHAUST FAN SHALL HAVE AMCA-CERTIFIED RATINGS SEAL. 9. CLOSE OU"I' 9.1. AS-BUILTS 9.2. BALANCING REPORT 93. O & M MANUALS 9.4. OPERATIONAL/COMMISSIONING REPORT COORDINATE FLASHING REQUIREMENTS WITH HVAC UNIT SUPPLIER PRE-FORMED ROOF CURB BY HVAC CONTR. ROOF MEMBRANE ROOF INSUL. METAL DECK \ 3 1/2"X3 1/2"Xl/4" ANGLE FItAME 3 1/2"X3 1/2"X1/4" ANGLES WELD TO JOISTS FIELD VERIFY JOIST LOCATIONS MEMBRANE FLASHING PRE-FORMED carrT sT�r ROOFT�P L1NIT SUPP�RT FRAMES SCALE:NONE NO'I'E: FTELD VERiFY EXTENT OF EXTSTTNG ELEMENTS AT UNIT OPENING. ADD NEW ITEMS AS REQUIRED PER DETAIL. FINAL CONFIGURATION OF OPENING AND MEMBER SIZES TO BE CONFIRMED BY A REGISTERFD ENGINEER. MECHANICAL NOTES 1. THIS WORK SI�AI,L INCLUDE ALL HEATING, VENTII.ATIING AND AIR CONDITIONING SYSTEMS REQUIRED AS INDICATED ON THE DRAWINGS, AND INCLUDES BUT IS NOT LIMI'TED TO HEAT'ERS, FANS, FILTERS, CONTROLS, DUCTS, DAMPERS, GRILLES, REGISTERS, DIFFUSF,RS, DUCT INSULATION, AND ALL ITEMS REQUIRED FOR COMPLETE AND OPERABLE SYSTEMS. 2. EQUIPMENT SUPPLIED AI�TD INSTALLED TO THE PROJECT SHALL BE �F THE M�NUFACTURER AND CAPACITY AS NOTED ON THE PLANS (OR EQUAL SUBSTITUTIONS WITH PRIOR WRITTEN APPROVAL ONLY). THE MECHANICAL SYSTEM HAS BEEN DESIGNED AS A COMPI.ETE PACKAGE; MECHANICAL CONTRACTOR SHAI..L VERIFY THAT ALL EQUIPMENT, CONTROLS, AND MISC. IT'EMS BE SUPPLIED TO PROVIDE A COMPLETE AND OPERABLE SYSTEM. 3. SUPPLY DUCTWORK TRUNKS SHAI.L BE OF SHEET METAL OF SIZE A1VD CONFIGURATION AS DESIGNED BY THE MECHANICAL CONTRACTOR FOR THE SPACE AREA AND AIR VOLUME HANDLED. 4. RETURN AIR DUCTWORK TRUNKS SHALL BE SHEET METAL OF THE PROPER GAGE FOR THE DUCT SIZE AND AIR VOLUIvIE HANDLED WITH 1/2" INTERIOR INSULATION BRACED AS REQUIRF_D FOR THE DUCT SIZE AND AIR VOLUME HANDLED. RETURN AIR TRUNK TO EXTEND MINIMUM OF 10' FROM UNIT CURB CONNECI'ION AS INDICA'ITD. NOTE: ALL SYSTEMS ABOVE 2000 CFM SHAI.L HAVE RETURN AIR FIRESTATS AS REQUIRED PER STATE AND LOCAL CODES COMPLETELY INSTALLED AS A PART OF THIS WORK AT "i , SYSTEMS SHALL BE COMPLETE WITH AI.L FIRE DAMPERS AS REQUIRED PER STATE AND LOCAL CODES. 5. ALL DUCTWORK SHALL BE SECURELY HUNG AND FASTENED TO PRIMARY OR SECONDARY STRUCTLJRAL MEMBERS ONLY. 6. PROVIDE ALL NECESSARY ISOLATORS, CONNECTORS, DAMPERS AND VOLUME CONTROLS FOR A COMPLETE AND CONTROLLABLE MECHA.NICAL SYSTEM. 7. DIFFUSERS AND EXHAUST GRILLES SHALI., BE I.ANDLORD'S STANDARD PRODUCTS FOR LAY-IN CEILING USE. PROVIDE ALL 1VECESSARY SPIN-INS, TAKE-0FFS, DAMPERS SUPPORTS, COIVI�iECI'ORS AND MISC. ITEMS FOR A COMPLETE INSTAI.I.ATION. 8. EXHAUST FAN SHAI.L BE TENANTS STANDARD PRODUCT. PROVIDE ALL NECESSARY HOODS, FLASHING, DAMPERS, CONTROIS, DUCTING, SUPPORTS, AND MISC. ITEMS FOR A COMPLETE INSTALLATION. 9. MECHAIVICAL CONTRACTOR SHAI,I, BE FAMILIAR WITH THE WORK OF ALL TRADES AND VERIFYlCOORDINATE HIS WORK WITH OTI-(ER TR�DES PRIOR TO TI-� BEGINNING OF WORK. 10. START-UP AND BAI�ANCING SHAI,L BE COMPLETED IMMEDIATELY BEFORE OCCUPANCY OF THE FACILITY BY THE OWNER. A SIGNED COPY OF THE BALANCIIVG REPORT SHALL BE DELIVERED TO THE OWNER UPON OCCUPAI�ICY. 11. ALL ROOF TOP UNI'I'S SHALL HAVE ECONOMIZERS SET TO 15'70 MIIVIMUM FRESH AIR INTAKE. 12. MECHANICAL CONTRACT'OR SHAI.,L INCLUDE ALL CONTROLS, CONDUIT AND CONTROL WIRING FOR ALL HVAC CONTOL SYSTEMS. 13. ALL REQUIRED PERMITS, LICENSES, INSPECTTON AND TEST CODES SHALL BE A PART OF THIS WORK. 14. ALL HEATING & COOLING SYSTEMS TO HAVE PROGRAMMABLE MICROELEC'TRONIC THERMOSTATS WITH ACCESS CODE AND FAN CONTROL FEATURE. 15. MECHANICAL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ITS UNDERWRITERS LABORATORY LABEI., THE MANLJFACT'UItERS' RECOMMENDATIONS, SPECIFICATIONS, AND GOOD ENGINEERING PRACTICES. 16. ALL MECHANICAL EQUIPMENT SHALL BE OF AN APPROVED TYPE AND SHALI, BE LABELED FOR USE IN THE AREAS PROPOSED FOR INSTALLATION. 17. CONTRACTOR TO VERIFY SIZE AND LOCATION OF ROOF CUTOUT FOR HVAC EQUIPMENT WITH Lt1NDLORD. LANDLORD'S ROOFER SHALL MAKE CUTOUT , INSTALL CURB AND FLASHING IN ORDER TO MAINTAIN LANDLORD'S ROOF WARRANTY. CONTRACTOR TO PROVIDE NLW STEEL SUBFRAME AT ROOF OPEIVING FOR ROOFTOP UNIT. REFER TO DETAIL 3/M101 FOR T`YPICAL FRAME CONSTRUC'TION. PROVIDE JOIST STIFFENERS AND/OR BRACING AS REQUIRED TO STABILIZE ROOF STRUCTLIRE AT OPENING. CONTRAC'TOR SHALL ENGAGE THE SERVICES OF A REGISTERED ENGINEER TO DETERMINE REINFORCING REQUIREMENTS FOR EXISTING ROOF STRUCTURE IN OREDR TO ACCOMODATE HVAC LINIT WEIGHT. SPRINKLER NOTES EXISTING FIRE SPRINKI,ER SYSTEM TO REMAIN INTACT AND FUNCTIOMNG. VARIES CONFIRM OPE1VIi SIZE WITH HVAC UNIT SUPPLIER 3 1/2"X3 1/2"Xl/4" ANGLE FRAME 3 1/2"X3 1/2"Xl/4" ANGLES WELD TO JOISTS PLAN VIEW v � � � � � � .x O� U � � Q � Q ��� �� � � ! Li , � � 0 .� .� a� � � � � o zo 0 - O --� � N � � W m - � ~ F- � m � N � Q���o � z���cD F-�-���� � � � � � Q g �'�WZ N ���z0 .� QQO�Z N W ��U�w � w � �~W�Q U � Z � U � � O � W �q (n C� �- O Z �i- � � � � o � � �� � � � � 4�; �� uf: �`� ! ,w, .;,�:�, ��•, �;* � �:; r� �, .�-� � � � �.- =� � � � � ;� �-,.- � � ,�� �a � � t'�° ; �-, a.�,; �. ,��.. � � � �x �, � �. � � �<; ":;> �k_y {"y�s. y;>.�,. � � �. � � � � � � a � � � � ��`�....�(' � � �9 • � O ,� � � ���dJ � � � Q - - - -, � � W`� � � � � �� � � � • � Stamp: ......��� ==-�P�. � �''��, '� •��T� ,/�; � 3 N0. , ' 17006 = "s ; ; STATE OF � .:� ; '',,� � . I� I A�'�P�\ - '� _ '' ��(AL �� ���`" Issue: STATE ISSUE Date: 3-19 -13 Project No.: A13329 File No.: Sheet: MP1�1