HomeMy WebLinkAbout13090093 Building PlansDALLAS, TEXAS 75201-1511INTERIOR DESIGN PHONE: 214.747.2511
SHEET INDEX
SHEET. NO.DESCRIPTION
GENERAL NOTES
A0.00
A1.10
A1.20
A1.30
COVER SHEET
DEMOLITION PLAN
CONSTRUCTION PLAN
KEYPLAN
REFLECTED CEILING PLANA1.40
A1.50
A6.10
POWER/COMMUNICATIONS PLAN
FINISH PLAN
A4.10
MARCUS & MILLICHAP
A6.11
FLOOR 5
A0.00
COVER SHEET
PLAN
NORTH
TRUE
NORTH
AREA OF WORK
DOOR & FRAME TYPES, DOOR SCHEDULE, HARDWARE SCHEDULE
A0.01 SPECIFICATIONS AND SYMBOLS
STAFFELBACH
AREA MAP
A1.21 DIMENSION PLAN
2525 MCKINNON ST., SUITE 800
A1.60 FURNITURE PLAN
CONTACT: MONICA WILSON/ADAM ANDREASEN
A1.51 CARPET SEAMING PLAN
06/25/2013
TRUE NORTH
JURISDICTION
BUILDING CODE
STRUCTURAL CODE
PLUMBING CODE
MECHANICAL CODE
ACCESSIBILITY
ELECTRICAL CODE
SQUARE FOOTAGE
OCCUPANT LOAD
OCCUPANCY GROUP
OCCUPANCY FACTOR
NUMBER OF EXITS
FIRE PROTECTION
MAXIMUM TRAVEL DISTANCE ALLOWED
MAXIMUM DEAD END
EXIT SEPARATION
CORRIDOR RATING
DOOR RATING
WINDOW
UNSPRINKLEDSPRINKLED
300 FEET
50 FEET
ONE THIRD
NONE
NONE
NONE
200 FEET
20 FEET
ONE HALF
1 HOUR
20 MINUTE
45 MINUTE
THIS BUILDING IS
B
SPRINKLED
BUILDING TYPE IIB
2
48
OFFICE AREA 100 S.F./PERSON
CODE CHECKLIST FLOOR 5
ALTERNATES
ALT#2
ALT#3
ALT#4
ALT#5
ALT#1
ALT#6
CEILING AND LIGHTING AT RECEPTION AS INDICATED ON 02/A2.10
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING FOR GYP BOARD
ISSUE SCHEDULE
DESCRIPTIONDATE RECIPIENT
FILL IN NAMELANDLORD - BID
FILL IN NAMECONTRACTOR - PERMIT
REVIEW SCHEDULE
6.19
RECEIVED
COMMENTS
FOR REVIEW
ISSUE DATE
REVIEWER
ISSUED
REVISIONS
6.196.18
DATE DATE DATE
6.25
6.19 6.25 6.25
DATE DATE DATE
MARCUS & MILLICHAP
LANDLORD
A2.11 ALTERNATES
ALL PLAN SHEETS FOR ALTERNATE LOCATIONS**
**GENERAL CONTRACTOR TO REFER TO SHEET A2.10 FOR ALTERNATE DETAILS, REFER TO
ISSUED
A1.31 POWER/COMMUNICATIONS FLOOR CORE LOCATION PLAN
A0.02 MARCUS & MILLICHAP SPECIFICATIONS & REQUIREMENTS
ALT#7
GENERAL NOTE TO THE CONTRACTOR:
TO BEGINNING THEIR WORK.
ARCHITECTURAL AND ENGINEERING DRAWINGS PRIOR
SUBCONTRACTORS HAVE REVIEWED BOTH
GENERAL CONTRACTOR SHALL VERIFY THAT ALL
MARCUS & MILLICHAP DEEMS APPROPRIATE.
CONTRACTORS EXPENSE TO CORRECT THE WORK AS
RESULT IN REJECTION OF WORK AT THE GENERAL
FAILURE TO COMPLY WITH THIS REQUIREMENT MAY
REQUIREMENTS.
ADDITIONAL MARCUS & MILLICHAP SPECIFIC
GENERAL CONTRACTOR TO REFER TO A0.02 FOR
CONSTRUCTION DOCUMENTS IS UNCLEAR.
THE EVENT THAT THE DESIGN INTENT OF THESE
GENERAL CONTRACTOR TO SUBMIT WRITTEN RFI'S IN
ALT#8
RESOLUTION.
IMMEDIATELY NOTIFY STAFFELBACH (IN WRITING) FOR A
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO
ARCHITECTURAL DRAWINGS ARE IN CONFLICT IT IS THE
IN THE EVENT THAT THE ENGINEERING AND
WITH DESIGN INTENT.
CONSTRUCTION DOCUMENTS TO INSURE COMPLIANCE
SUBCONTRACTORS WITH A COMPLETE SET OF
GENERAL CONTRACTOR WILL PROVIDE ALL
BREAK ROOM ELEVATIONS, SECTIONS & DETAILS
PARTITION TYPES & DETAILS
THEIR TRADE.
DRAWINGS FOR DESIGN INTENT AS IT PERTAINS TO
REVIEWING ARCHITECTURAL AND ENGINEERING
EACH SUBCONTRACTOR IS RESPONSIBLE FOR
ENGINEERING DRAWINGS.
DRAWINGS SUPERCEDE LOCATIONS SHOW ON
SPECIFIC LOCATIONS OF DEVICES ON ARCHITECTURAL
#501). REFER TO 10/A2.10
INSTALL WOOD AND GLASS DOOR ENTRANCE TO SMALL CONFERENCE ROOM (DOOR
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND
A1.41 REFLECTED CEILING ENLARGED PLANS
A1.32
M. WILSON/STAFFELBACH
A. ANDREASEN/STAFFELBACH
A. PERRIN/STAFFELBACH
(FOR CLIENT USE ONLY)
CONTRACT IS AWARDED
LIGHTING, STONE FLOORING, ETC.) AS SOON AS
LONG LEAD ITEMS (I.E. ALUMINUM FRAMING, DOORS,
GENERAL CONTRACTOR TO IDENTIFY AND ORDER ALL
(DOOR #506). REFER TO 16/A2.10
INSTALL WOOD AND GLASS DOOR AT DOOR BETWEEN RECEPTION AND OPEN OFFICE
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND
POWER/COMMUNICATIONS ENLARGED PLANS
WARRANTIES AND OPERATING INSTRUCTIONS
G17
G20
CLARIFICATIONS
G18 CLAIMS FOR ADDITIONAL COSTS
G19 DOCUMENTATION AT SITE
WORK.
TO STAFFELBACH FOR SUBMITTAL TO THE OWNER UPON COMPLETION OF THE
CONSTRUCTION. THREE COPIES OF THESE RECORD DRAWINGS ARE TO BE DELIVERED
CURRENTLY TO RECORD FIELD CHANGES AND SELECTIONS MADE DURING
SPECIFICATIONS, ADDENDA, CHANGE ORDERS AND OTHER MODIFICATIONS, AND MARKED
CONTRACTOR SHALL MAINTAIN, ON THE SITE, ONE RECORD COPY OF THE DRAWINGS/ G19.1
G16.7 THE CONTRACTOR SHALL REVIEW AND STAMP, WITH HIS APPROVAL , ALL
SUBMITTALS. ANY SUBMITTALS WHICH DO NOT BEAR CONTRACTOR'S APPROVAL
STAMP SHALL BE RETURNED WITHOUT REVIEW. WHERE PRINTED MATERIALS
DESCRIBE MORE THAN ONE PRODUCT OR MODEL, CLEARLY IDENTIFY WHICH IS TO
BE FURNISHED. SHOP DRAWINGS SHALL NOT BE REPRODUCTIONS OF
CONSTRUCTION DOCUMENTS. EACH SHOP DRAWING, SAMPLE AND PRODUCT DATA
SUBMITTAL SHALL BE PROPERLY IDENTIFIED BEARING THE NAME AND QUALITY OF
THE MATERIAL, THE MANUFACTURER'S NAME, THE CONTRACTOR'S NAME, THE
SUBCONTRACTOR'S NAME, THE NAME OF THE PROJECT AND THE DATE OF
SUBMISSION.
G16.8 REJECTED SHOP DRAWINGS AND SAMPLES SHALL BE RESUBMITTED AS SOON AS
POSSIBLE AND SHALL BE IDENTIFIED AS "RESUBMITTALS".
G16.9 THE CONTRACTOR SHALL IDENTIFY SPECIFIC ATTENTION, IN WRITING, ON
RESUBMITTED SHOP DRAWINGS, PRODUCT DATA OR SAMPLES TO REVISIONS,
OTHER THAN THOSE REQUESTED BY STAFFELBACH.
CORRESPONDENCE.
STAFFELBACH IN THE FORM OF CLARIFICATION DRAWINGS AND/OR WRITTEN
DIRECTED TO STAFFELBACH. ALL RESPONSES SHALL BE ISSUED THROUGH
ALL REQUESTS FOR CLARIFICATION OF THE CONSTRUCTION DRAWINGS SHALL BE G17.1
SHALL BE AUTHORIZED BY A WRITTEN CHANGE ORDER APPROVED BY OWNER.
PROPERTY. ANY CHANGE IN THE CONTRACT SUM RESULTING FROM SUCH CLAIM
TO EXECUTE THE WORK, EXCEPT IN AN EMERGENCY ENDANGERING LIFE OR
CLAIM. THIS NOTICE SHALL BE GIVEN BY THE CONTRACTOR BEFORE PROCEEDING
SEVEN (7) DAYS AFTER THE OCCURRENCE OF THE EVENT GIVING RISE TO SUCH
CONTRACT SUM, HE SHALL GIVE STAFFELBACH WRITTEN NOTICE THEREOF WITHIN
IF THE CONTRACTOR WISHES TO MAKE A CLAIM FOR AN INCREASE IN THE G18.1
COMPLETIONG21
SECURITY
PROTECTION OF PERSONS AND PROPERTY
DEBRIS CONTROL AND CLEANING
G2
G3
G4
G5
G1
G15
G16
G13
G10
G12
SUPPLEMENTAL INSTRUCTIONS
CONSTRUCTION DOCUMENTS
CONTRACTUAL RELATIONSHIPS
BIDDING
SUBSTITUTIONS
CONSTRUCTION PROGRESS SCHEDULEG6
USE OF PREMISESG7
INTERRUPTION OF SERVICESG11
PROJECT MEETINGSG14
WORKMANSHIP AND MATERIALS
SUBMITTALS
OR NOT.
INSTALLATION, REGARDLESS OF WHETHER SHOWN ON THE DRAWINGS
MAKE A COMPLETE, IN PLACE, PROPERLY WORKING AND FINISHED
AND FINISH WORK WITH ALL PARTS AND MATERIALS NECESSARY TO
DEFINITIONS, 1.1.10 - "WORK" SHALL INCLUDE ALL LABOR, ASSEMBLIES
ADD THE FOLLOWING DEFINITION TO AIA A201, PARAGRAPH 1.1 - BASIC G1.3
LABOR, INSTALLATION, ETC. PER BUILDING OWNER'S CRITERIA.
DRAWINGS AND AS SPECIFIED HEREIN, REFERS TO ALL MATERIALS,
DEFINITIONS, 1.1.9 - THE TERM "BUILDING STANDARD" AS NOTED ON
ADD THE FOLLOWING DEFINITION TO AIA A201, PARAGRAPH 1.1 - BASIC G1.2
EXCEPT AS OTHERWISE NOTED.
BE FURNISHED, INSTALLED AND CONNECTED, WHERE SO REQUIRED,
WITH ANY ITEM SPECIFIED IS INTENDED TO MEAN THAT SUCH SHALL
DEFINITIONS, 1.1.8 - THE USE OF THE WORD "PROVIDE" IN CONNECTION
ADD THE FOLLOWING DEFINITION TO AIA A201, PARAGRAPH 1.1 - BASIC G1.1
DRAWINGS TO ASCERTAIN ANY DIMENSION.
SCALE, CONTRACTOR SHALL NOT DIRECTLY MEASURE OR "SCALE" SAID
UNLESS NOTED OTHERWISE, ALL DRAWINGS HAVE BEEN PRODUCED TO G2.3
STAFFELBACH PRIOR TO CONSTRUCTION.
DRAWINGS ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF
ANY CONFLICTS BETWEEN THE MEP DRAWINGS AND THE ARCHITECTURAL G2.2
RELATED DOCUMENTS.
CONSTRUCTION DOCUMENT SHALL BE PROVIDED AS THOUGH ON ALL
COMPLEMENTARY. ANY WORK SHOWN OR REFERRED TO ON ANY
ALL DIMENSIONS AND DESCRIPTIONS ON CONSTRUCTION DRAWINGS ARE G2.1
BETWEEN THE CONTRACTOR AND STAFFELBACH.
CONTRACT DOCUMENTS, SHALL CREATE ANY CONTRACTUAL RELATIONSHIP
NOTHING CONTAINED IN THESE DRAWINGS, OR IN ANY ACCOMPANYING G3.1
SHEET.
THEIR ENTIRETY, INCLUDING ALL INFORMATION CONTAINED IN THIS COVER
THAT HE HAS READ AND REVIEWED THESE CONSTRUCTION DOCUMENTS IN
THE CONTRACTOR SHALL EXPRESSLY ACKNOWLEDGE, IN WRITING, IN HIS BID, G4.4
SUBCONTRACTORS.
NOTIFY STAFFELBACH IN WRITING AS TO THE NAMES OF ALL
WITHIN FIVE (5) DAYS FROM AWARD OF THE CONTRACT, CONTRACTOR SHALL G4.3
RECOGNIZED.
HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE, WILL NOT BE
OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD
EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT AND/
SUBMISSION OF A BID WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN
DISCREPANCIES FROM THE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. THE
CONTRACTOR SHALL NOTIFY STAFFELBACH IN WRITING OF ANY VARIATIONS OR G4.2
CHECK LOCATIONS OF THE EXISTING STRUCTURE AND EQUIPMENT.
TO BE PERFORMED. THE CONTRACTOR SHALL AT SUCH TIME ASCERTAIN AND
DRAWINGS AND BE SATISFIED AS TO THE CONDITIONS UNDER WHICH WORK IS
THEREOF WHICH WILL AFFECT THIS WORK AND SHALL COMPARE IT WITH THE
PRIOR TO THE BID, THE CONTRACTOR SHALL EXAMINE THE SITE AND PORTIONS G4.1
ANY "OR EQUAL" NOTED IN THE SPECIFICATIONS.
SUPERIOR TO THE SPECIFIED PRODUCT SHALL BE FINAL. THIS SECTION APPLIES TO
UNIT COST. STAFFELBACH'S DECISION AS TO WHETHER A PRODUCT IS EQUAL OR
STAFFELBACH WITH ALL APPROPRIATE MANUFACTURER'S DATA AND LITERATURE AND
CONSIDERED. ANY SUCH PROPOSED SUBSTITUTION SHALL BE SUBMITTED TO
REVIEW BE OBTAINED PRIOR TO BIDDING, OR THE SUBSTITUTION WILL NOT BE
REVIEW AND WRITTEN ACCEPTANCE BY STAFFELBACH IT IS MANDATORY THAT SUCH
OR BETTER PRODUCT OF ANOTHER MANUFACTURER MAY BE ACCEPTED ONLY UPON
WHERE A PARTICULAR MANUFACTURER OR ITEM HAS BEEN SPECIFIED, AN EQUAL TO, G5.1
COORDINATE THIS WITH BUILDING LANDLORD.
THOSE ALLOWED FOR IN THE BUILDING'S STRUCTURAL DESIGN. CONTRACTOR TO
CONSTRUCTION IN A MANNER THAT PREVENTS LIVE LOADS FROM EXCEEDING
CONTRACTOR IS RESPONSIBLE FOR STACKING OF ALL MATERIALS DURING G7.4
SCHEDULED WITH OWNER'S AND BUILDING LANDLORD'S APPROVAL.
CORING AND OTHER WORK WHICH MIGHT AFFECT OTHER TENANTS SHALL BE G7.3
CONTRACTOR SHALL MINIMIZE NOISE DISTURBANCE TO ADJACENT OCCUPANTS.G7.2
OPERATION.
THE INCONVENIENCE OF THE TENANTS AND OWNER'S PERSONNEL AND
OWNER. CONTRACTOR SHALL NOT UNREASONABLY ENCUMBER THE PREMISES TO
MATERIALS, AND THE OPERATION OF HIS WORKMEN TO LIMITS DEFINED BY THE
CONTRACTOR SHALL CONFINE HIS APPARATUS, DELIVERY AND STORAGE OF G7.1
TENANCIES.
OWNER AND/OR BUILDING'S LANDLORD, TO PROTECT ADJACENT CORRIDORS AND
CONTRACTOR SHALL ERECT DUST-PROOF BARRIERS, AT THE DIRECTION OF THE G10.2
SATISFACTION OF THE OWNER AT THE EXPENSE OF THE CONTRACTOR.
STRUCTURES, AND EQUIPMENT SHALL BE REPAIRED OR REPLACED TO THE
OF CONSTRUCTION. DAMAGE TO NEW AND EXISTING MATERIAL, FINISHES,
CLOSURE WALLS, ETC., AS REQUIRED TO PROTECT THE PUBLIC DURING THE PERIOD
DUST, WATER, ETC., AND SHALL PROVIDE AND MAINTAIN TEMPORARY BARRICADES,
FINISHES FROM DAMAGE WHICH MAY OCCUR FROM CONSTRUCTION, DEMOLITION,
CONTRACTOR SHALL PROTECT AREAS AND NEW OR EXISTING MATERIALS AND G10.1
SHUTDOWN OCCURS.
BE NOTIFIED AS REQUIRED BUT NOT LESS THAN 48 HOURS IN ADVANCE BEFORE
PLUMBING, OR TELEPHONE SERVICE. OWNER AND/ OR BUILDING'S LANDLORD SHALL
REGARD TO ANY INTERRUPTIONS OR SHUTDOWN OF ELECTRICAL, MECHANICAL,
CONTRACTOR SHALL COOPERATE WITH OWNER AND/OR BUILDING'S LANDLORD IN G11.1
LIMITED ACCESS.
WITH THE OWNER AND/OR BUILDING'S LANDLORD IN REGARD TO ANY AREAS OF
REQUIRE ACCESS TO THE FACILITY DURING CONSTRUCTION, AND SHALL COOPERATE
NECESSARY FOR ALL HIS WORKMEN, SUBCONTRACTORS, AND SUPPLIERS WHO MAY
REQUIRED SECURITY CLEARANCES, ACCESS ARRANGEMENTS, PASSES, OR BADGES
CONTRACTOR SHALL OBTAIN THROUGH OWNER AND/OR BUILDING'S LANDLORD, THE G12.1
AS INDICATED.
USE ONLY NEW, HIGHEST QUALITY MATERIALS CONSISTENT WITH SPECIFICATIONS
FABRICATION AND INSTALLATION FOR EACH TRADE. UNLESS OTHERWISE NOTED,
MANNER, IN ACCORDANCE WITH THE INDUSTRY STANDARD FOR CONSTRUCTION,
ALL WORK SHALL BE DONE IN THE FINEST QUALITY/WORKMANSHIP - LIKE G15.1
G16.1 WITHIN FIVE (5) DAYS FROM AWARD OF THE CONTRACT, CONTRACTOR SHALL
SUBMIT TO STAFFELBACH, A DETAILED SHOP DRAWING SUBMITTAL AND SAMPLE
SCHEDULE.
CHECKED AND COORDINATED WITH THE REQUIREMENTS OF THE CONTRACT.
CATALOG NUMBERS AND SIMILAR DATA, THAT EACH SUBMITTAL HAS BEEN
VERIFIED FIELD MEASUREMENTS, FIELD CONSTRUCTION CRITERIA, MATERIALS,
STAFFELBACH, THE CONTRACTOR REPRESENTS THAT HE HAS DETERMINED AND
BY APPROVING AND SUBMITTING SHOP DRAWINGS AND SAMPLES TO G16.6
COMPONENT.
SHALL NOT INDICATE APPROVAL OF AN ASSEMBLY OF WHICH THE ITEM IS A
SEQUENCES OR PROCEDURES. STAFFELBACH'S APPROVAL OF A SPECIFIC ITEM
STATED BY STAFFELBACH, OF ANY CONSTRUCTION MEANS, METHODS, TECHNIQUES,
APPROVAL OF SAFETY PRECAUTIONS, OR UNLESS OTHERWISE SPECIFICALLY
BY THE CONTRACT DOCUMENTS. STAFFELBACH'S REVIEW SHALL NOT CONSTITUTE
ALL OF WHICH REMAIN THE RESPONSIBILITY OF THE CONTRACTOR AS REQUIRED
INSTRUCTIONS FOR INSTALLATION OR PERFORMANCE OF EQUIPMENT OR SYSTEMS,
OTHER DETAILS SUCH AS DIMENSIONS AND QUANTITIES, OR FOR SUBSTANTIATING
FOR THE PURPOSE OF DETERMINING THE ACCURACY AND COMPLETENESS OF
PERMIT ADEQUATE REVIEW. REVIEW OF SUCH SUBMITTALS IS NOT CONDUCTED
ALLOWING SUFFICIENT TIME IN STAFFELBACH'S PROFESSIONAL JUDGMENT TO
THE ACTIVITIES OF THE OWNER, CONTRACTOR OR SEPARATE CONTRACTORS, WHILE
SUCH REASONABLE PROMPTNESS AS TO CAUSE NO DELAY IN THE WORK OR IN
IN THE CONTRACT DOCUMENTS. STAFFELBACH'S ACTION WILL BE TAKEN WITH
CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED
SAMPLES, BUT ONLY FOR THE LIMITED PURPOSE OF CHECKING FOR
CONTRACTOR'S SUBMITTALS SUCH AS SHOP DRAWINGS, PRODUCT DATA AND
STAFFELBACH WILL REVIEW OR TAKE OTHER APPROPRIATE ACTION UPON THE G16.5
ACCEPTANCE THEREOF.
DRAWINGS, PRODUCT DATA, SAMPLES OR SIMILAR SUBMITTALS BY STAFFELBACH'S
BE RELIEVED OF RESPONSIBILITY FOR ERRORS OR OMISSIONS OF SHOP
WRITTEN ACCEPTANCE TO THE SPECIFIC DEVIATION. THE CONTRACTOR SHALL NOT
SUCH DEVIATION AT THE TIME OF SUBMITTAL AND STAFFELBACH HAS GIVEN
THE CONTRACTOR HAS SPECIFICALLY INFORMED STAFFELBACH, IN WRITING, OF
OF SHOP DRAWINGS, PRODUCT DATA, SAMPLES OR SIMILAR SUBMITTALS UNLESS
FROM REQUIREMENTS OF THE CONTRACT DOCUMENTS BY STAFFELBACH'S REVIEW
THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITIES FOR DEVIATIONS G16.4
SUBMITTALS.
STAFFELBACH. SUCH WORK SHALL BE IN ACCORDANCE WITH ACCEPTED
SIMILAR SUBMITTALS UNTIL THE RESPECTIVE SUBMITTAL HAS BEEN REVIEWED BY
SUBMITTAL AND REVIEW OF SHOP DRAWINGS, PRODUCT DATA, SAMPLES OR
THE CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK REQUIRING G16.3
TOILET FACILITIES AND DRINKING WATER
CONSTRUCTION OFFICEG8
G9
CHARGED TO THOSE INCURRING SUCH COSTS.
DISTANCE CHARGES SHALL BE PAID BY THE CONTRACTOR AND MAY BE
USE OF ALL SUBCONTRACTORS, SUPPLIERS, DESIGNERS, AND INSPECTORS. LONG
CONTRACTOR SHALL PROVIDE UNLIMITED LOCAL TELEPHONE SERVICE FOR THE G8.4
SIMILAR REQUIRED SUBMITTALS FOR REFERENCE.
RECORD DRAWINGS, RECORD SHOP DRAWINGS, PRODUCT DATA, SAMPLES AND
CONTRACTOR SHALL MAINTAIN, ON THE SITE, ONE RECORD COPY OF THE G8.3
CONSTRUCTION OR OPERATIONS OF THE TENANT'S OWN FORCES.
DELAY, OR INTERFERENCE WITH THE WORK OF OTHER VENDORS OR THE
SCHEDULING AND PERFORMING THE CONTRACTOR'S WORK TO AVOID CONFLICT,
OWN FORCES. CONTRACTOR SHALL COOPERATE WITH THE TENANT ON
CONTRACTOR SHALL ALLOW FOR ACCESS BY OTHER VENDORS AND TENANT'S G8.2
LOCATED AS DIRECTED BY THE OWNER AND/OR LANDLORD.
CONTRACTOR SHALL PROVIDE AND MAINTAIN A FIELD CONSTRUCTION OFFICE, G8.1
COST OF CLEANUP OR REPAIR.
FOUNTAINS, THE OWNER MAY HOLD THE CONTRACTOR RESPONSIBLE FOR THE
CAUSING ANY DAMAGE TO EXISTING TOILET FACILITIES OR DRINKING
DRINKING FOUNTAIN UNNECESSARILY DIRTY, OR ARE RESPONSIBLE FOR
OF THE WORKMEN ARE RESPONSIBLE FOR LEAVING A TOILET ROOM OR
DURATION OF THE PROJECT. IF, AT ANY TIME, THE OWNER FEELS THAT ANY
BUILDING SHALL BE AVAILABLE FOR THE USE OF ALL WORKMEN FOR THE
DESIGNATED TOILET FACILITIES AND DRINKING FOUNTAINS WITHIN THE
UPON THE APPROVAL OF THE BUILDING'S LANDLORD, THE USE OF G9.1
AND FIXTURES FINISHED, CLEANED, ORDERLY, AND READY FOR MOVE-IN.
AT COMPLETION, THE CONTRACTOR SHALL LEAVE PREMISES AND ALL SURFACES G13.2
BE USED FOR THIS PURPOSE.
AREAS INSIDE OR OUTSIDE JOB SITE. THE BUILDING REFUSE FACILITIES SHALL NOT
PREVENT ANY DIRT, DEBRIS, OR DUST FROM AFFECTING, IN ANY WAY, FINISHED
REGULAR BASIS, AND SHALL EXERCISE STRICT CONTROL OVER JOB CLEANING TO
THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIAL ON A G13.1
OPERATING INSTRUCTIONS HAVE BEEN RECEIVED BY STAFFELBACH/TENANT.
LIST HAVE BEEN RESOLVED AND ALL RECORD DRAWINGS, WARRANTIES AND
PROJECT WILL NOT BE CONSIDERED COMPLETE UNTIL ALL ITEMS ON THE PUNCH
PUNCH LIST ITEMS WITHIN TWO (2) WEEKS OF RECEIPT OF PUNCH LIST. THE
INCOMPLETE OR UNACCEPTABLE WORK. CONTRACTOR SHALL COMPLETE ALL
STAFFELBACH/TENANT SHALL PREPARE A FINAL PUNCH LIST OUTLINING
STAFFELBACH/TENANT ACCORDINGLY IN WRITING. UPON INSPECTION,
WHEN CONTRACTOR IS NEARING COMPLETION, HE SHALL NOTIFY G21.1
CERTIFICATES OF INSURANCE FOR PRODUCTS AND COMPLETED OPERATIONS.
CONSENT OF SURETY AND FINAL PAYMENT
EVIDENCE OF PAYMENT AND RELEASE OF LIENS
KEY AND KEYING SCHEDULE
SPARE PARTS AND MAINTENANCE MATERIALS
WARRANTIES AND BONDS
OPERATIONS AND MAINTENANCE DATA
PROJECT RECORD DOCUMENTS
EVIDENCE OF COMPLIANCE WITH REQUIREMENTS OF GOVERNING AUTHORITIES.
FOLLOWING:
STAFFELBACH, IN TRIPLICATE, CLOSEOUT DOCUMENTATION CONSISTING OF THE
PRIOR TO FINAL APPLICATION FOR PAYMENT, CONTRACTOR SHALL SUBMIT TO G20.2
BY PRODUCT MANUFACTURERS, SUPPLIERS, ETC.
ADDITION TO (NOT IN LIEU OF) ANY WARRANTIES AND/OR GUARANTEES PROVIDED
RESPECTIVE WORKMANSHIP AND/OR MATERIALS. THIS GUARANTEE SHALL BE IN
SUBCONTRACTORS: A ONE (1) YEAR WRITTEN GUARANTEE AGAINST DEFECTIVE
SHALL SUBMIT TO STAFFELBACH, IN TRIPLICATE, ON BEHALF OF HIMSELF AND HIS
PRIOR TO FINAL APPLICATION FOR PAYMENT OF THE PROJECT, THE CONTRACTOR G20.1
USED BY OTHERS IN WHOLE OR IN PART FOR ADDITIONS TO THIS PROJECT OR FOR OTHER PROJECTS.
OF STAFFELBACH'S DESIGN SERVICE FOR USE SOLELY WITH RESPECT TO THIS PROJECT. THESE DOCUMENTS SHALL NOT BE
THE CONSTRUCTION DOCUMENTS PREPARED BY STAFFELBACH DESIGN ASSOCIATES FOR THIS PROJECT ARE INSTRUMENTS
AIA DOCUMENT A201- 2007 GENERAL CONDITIONS SHALL BE INCORPORATED INTO THESE DOCUMENTS.
PRODUCT DATA, OR SAMPLES FOR SUCH PORTIONS OF THE WORK.
WORK AT ANY TIME WITHOUT CONSTRUCTION DOCUMENTS, OR WHERE REQUIRED, APPROVED SHOP DRAWINGS,
OMISSIONS TO STAFFELBACH DESIGN ASSOCIATES (STAFFELBACH). CONTRACTOR SHALL PERFORM NO PORTION OF THE
CONSULTANT'S DRAWINGS AND SHALL IMMEDIATELY REPORT ANY NOTED DISCREPANCIES, INCONSISTENCIES, OR
THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONSTRUCTION DOCUMENTS INCLUDING
PHOTOS
G14.4 CONTRACTOR TO SEND UPDATED PROJECT SCHEDULE AND WEEKLY PROGRESS
PARTICIPANTS.
SHALL BE DISTRIBUTED WITHIN FOUR DAYS AFTER EACH MEETING TO ALL
INCLUDING SIGNIFICANT PROCEDURES AND DECISIONS. COPIES OF THESE MINUTES
THE CONTRACTOR SHALL RECORD MINUTES OF THE PROJECT MEETINGS G14.3
TO THE AGENDA, AND OTHERS.
STAFFELBACH, THE SUBCONTRACTORS OR SUPPLIERS AS MAY BE APPROPRIATE
ATTENDED BY: THE CONTRACTOR, THE OWNER OR OWNER'S REPRESENTATIVE,
COPIES TO PARTIES IN ATTENDANCE. IN GENERAL, THESE MEETINGS SHOULD BE
THE CONTRACTOR SHALL PREPARE AGENDAS OF THE MEETING AND DISTRIBUTE G14.2
PERIODIC MEETINGS TO REVIEW THE PROJECT.
AT THE OWNERS REQUEST, THE CONTRACTOR SHALL SCHEDULE REGULAR AND G14.1
REFER 12/A2.10. INCLUDE ALTERNATE HARDWARE SHOWN ON 08/A2.10
COMPLETE WOOD AND GLASS DOOR(S) AT LARGE CONFERENCE ROOM (DOOR #503).
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND INSTALL
REFER TO 05/A2.10. INCLUDE ALTERNATE HARDWARE SHOWN ON 08/A2.10
COMPLETE WOOD AND GLASS DOOR(S) AT TENANT MAIN ENTRY / RECEPTION (DOOR #500).
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND INSTALL
INDIANAPOLIS, INDIANA
E. 96TH ST.
N
. C
O
LLEG
E AVE.
USS INDIANAPOLIS MEMORIAL HWY
BRO
AD
W
AY ST.
N
. PARK AVE.
C
EN
TRAL AVE.
465
465
A1.00 LIFE SAFETY PLAN
A7.10 PLUMBING DIAGRAM & HVAC PLAN
4,631 USF
CITY OF INDIANAPOLIS
2008 INDIANA BUILDING CODE
2008 INDIANA BUILDING CODE
1999 INDIANA PLUMBING CODE
2008 INDIANA MECHANICAL CODE
2009 INDIANA ELECTRICAL CODE
ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE
2008 INDIANA BUILDING CODE - CH. 11 ACCESSIBILITY
DATE.
FOR SYSTEMS FURNITURE INSTALLATION PRIOR TO FINAL COMPLETION
STEMS FURNITURE INSTALLATION AND CONSIDER A MINIMUM OF 5 DAYS
G6.3 CONTRACTOR MUST SCHEDULE CARPET INSTALLATION FINISH PRIOR TO SY
AND MUNICIPAL LAW.
ALL PHASES OF THE WORK AS REQUIRED BY FEDERAL, STATE, COUNTY
THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING PERMITS FOR G6.2
SCHEDULE OF THE WORK IN BAR CHART FORM.
PREPARE AND SUBMIT TO STAFFELBACH A PRELIMINARY PROGRESS
THE CONTRACTOR, PRIOR TO BEING GIVEN NOTICE TO PROCEED, SHALL G6.1
6.24 6.25
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
06/25/2013
NOT USED
NOT USED
INSTALL CLEARSTORY WINDOW AS INDICATED ON 12/A2.10 (FOR ALT #5 ONLY)
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
3
7
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
0
_
0
0
c
v
r
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
AND SYMBOLS
SPECIFICATIONS
A0.01•" = 1'-0"
HEIGHT OF FURNITURE WHIPS
17
"
14
"
NO LOWER THAN 15" @ BOTTOM
NORMAL OUTLET HEIGHT
3
9
"
(
4
8
"
M
A
X
)
4
4
"
@
C
O
U
N
T
E
R
T
O
P
S
4
8
"
M
A
X
(
S
W
IT
C
H
&
P
H
O
N
E
)
8
0
"
M
IN
4
8
"
M
A
X
WHERE APPLICABLE
ABOVE OUTLET
CABINET - CENTER
FIRE EXTINGUISHER
O
R
6
"
B
E
L
O
W
C
E
IL
IN
G
-
W
H
IC
H
E
V
E
R
IS
L
O
W
E
R
9"
REFER MEP
ALIGN ABOVE LIGHT SWITCH
FOR WALL MOUNTED FIRE STROBES
ELECTRICAL/DOOR HARDWARE
TYPICAL MOUNTING HEIGHTS01
T
O
H
IG
H
E
S
T
O
P
E
R
A
B
L
E
P
A
R
T
SPECIFICATIONS
REFER SHEET(S) A1.50, FOR FINISH SPECIFICATIONS.
REFER THIS SHEET FOR MISCELLANEOUS PRODUCT SPECIFICATIONS.
SPECIFICATION GENERAL NOTES
CONTRACTOR HAS ACCEPTED ALL NOTES AS PART OF THE CONTRACT.
WITH WHICH HE CANNOT COMPLY. FAILURE TO DO SO SHALL INDICATE THAT THE
CONTRACTOR SHALL QUALIFY IN HIS BID ANY NOTES WITHIN THE GENERAL SPECIFICATIONS 3.
SUBMITTED TO ARCHITECT FOR REVIEW AND APPROVAL.
PRODUCTS / FINISHES NOT IDENTIFIED IN GENERAL SPECIFICATIONS ABOVE SHALL BE 2
CONSTRUCTION DETAILS.
PRODUCT SPECIFICATIONS TAKE PRECEDENCE OVER INFORMATION CONTAINED IN 1.
AND LAVATORIES.
COMPLY WITH MARBLE INSTITUTE OF AMERICA RECOMMENDATIONS FOR STONE COUNTER TOPS F.
UNLESS INDICATED OTHERWISE, PROVIDE TIGHT, HAIRLINE JOINTS BETWEEN STONE SECTIONS.E.
CONTRACTION OF MATERIALS.
DESIGN CONSTRUCTION AND INSTALLATION DETAILS TO ALLOW FOR EXPANSION AND D.
COLORS.
COLOR AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE OF STANDARD b.
SILICONE, TESTED AND PROVEN NOT TO STAIN SELECTED STONE.a.
JOINT SEALERS:3.
WATERPROOF, PERMANENT MATERIAL.b.
NON-STAINING - TYPE AS RECOMMENDED BY STONE MANUFACTURER.a.
2. STONE SEALERS:
REFER FINISH SCHEDULE FOR SPECIFIC STONE TYPES, FINISHES, ETC.1.
MATERIALSC.
SUBMIT PRODUCT DATA FOR MANUFACTURER RECOMMENDED.4.
INCLUDE STONE SAMPLES INDICATING JOINING AND EDGING.3.
2. INDICATE MAXIMUM RANGE OF STONE VARIATION.
SUBMIT 12" X 12" SAMPLES WITH APPROPRIATE FINISH.1.
SUBMIT THE FOLLOWING:B.
FASTENING, CUTOUTS, SINKS, ACCESSORIES, SUPPORTING ELEMENTS AND RELATED ITEMS.
PROVIDE SHOP DRAWINGS AT HALF OR FULL SCALE INDICATING PROFILES OF MEMBERS, JOINTING, A.
SECTION 04 40 00 - STONE COUNTERTOP & VANITIES
SECTION 08 71 00 - HARDWARE
PROVIDE TWO (2) YEAR WARRANTY.G.
KEYING WILL BE COORDINATED BETWEEN TENANT AND LANDLORD.F.
MARKING ON DOOR UL LABEL ON EXIT DEVICE INDICATING "FIRE EXIT HARDWARE."
WHERE PANIC EXIT DEVICES ARE REQUIRED ON FIRE-RATED DOORS, PROVIDE SUPPLEMENTARY 1.
SEALS ARE REQUIRED WHETHER OR NOT LISTED IN THE HARDWARE SCHEDULE.
AND THE DOOR FRAME LABELS. LATCHING HARDWARE, DOOR CLOSERS, BALL BEARING HINGES, AND
THE TYPE AND SIZE OF DOOR REQUIRED, AND COMPLIES WITH THE REQUIREMENTS OF THE DOOR
HARDWARE. PROVIDE ONLY SUCH HARDWARE WHICH HAS BEEN TESTED AND LISTED BY UL FOR
NFPA 80. THIS REQUIREMENT TAKES PRECEDENCE OVER OTHER REQUIREMENTS FOR SUCH
FIRE-RATED OPENINGS: PROVIDE HARDWARE FOR FIRE-RATED OPENINGS IN COMPLIANCE WITH E.
MOST STRINGENT).
STATE OF TEXAS, ELIMINATION OF ARCHITECTURAL BARRIERS ACT, ARTICLE 115.62 (WHICHEVER IS
HARDWARE SHALL COMPLY WITH ALL LOCAL CODES AND ORDINANCES, AS WELL AS ANSI 117.1 AND D.
PRODUCT DATA.2.
HARDWARE SCHEDULE.1.
SUBMIT THE FOLLOWING:C.
REFER TO HARDWARE SPECIFICATIONS FOR HARDWARE PRODUCTS / SCHEDULE.B.
REFER ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
SECTION 08 80 00 - GLAZING
COMPLY WITH MANUFACTURER"S RECOMMENDED PREPARATION AND INSTALLATION PROCEDURES.E.
SPANS ENCOUNTERED.
GLASS UNIT THICKNESSES ARE INDICATED AS MINIMUMS, TO BE INCREASED AS REQUIRED BY D.
ENTER DATA.TYPE 4:4.
ENTER DATA.TYPE 3:3.
ORDINANCES).
3/8" CLEAR FLOAT GLASS (TEMPERED AS REQUIRED BY ANSI, LOCAL CODES AND TYPE 2:2.
ORDINANCES).
1/4" CLEAR FLOAT GLASS (TEMPERED AS REQUIRED BY ANSI, LOCAL CODES AND TYPE 1:1.
PRODUCT SPECIFICATIONS ARE AS FOLLOWS:C
SHOP DRAWINGS SHOWING SIZE AND LOCATION OF EACH INSTALLATION.3.
PRODUCT DATA.2.
THREE (3) SAMPLES OF EACH TYPE OF GLASS WITH SPECIFIED FINISH WHERE INDICATED.1.
SUBMIT THE FOLLOWING:B.
REFER ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
SECTION 09 21 00 - GYPSUM BOARD SYSTEMS
PROVIDE CONTROL JOINTS; COORDINATE FINAL LOCATIONS IN THE FIELD WITH ARCHITECT.K.
MAXIMUM VARIATION FROM TRUE FLATNESS TO BE 1/8" IN 10'-0" IN ANY DIRECTION.J.
FINISHES AS SPECIFIED IN FINISH SCHEDULE.
WALL TEXTURE TO HAVE SMOOTH SURFACE AFTER TAPE & BED AND READY TO RECEIVE NEW I.
JOINTS OR ANGLES.
AND BOTTOM, WITH STUDS AT 16' O.C. IN ORDER TO ACHIEVE A SMOOTH RADIUS WITHOUT VISIBLE
CURVED OR RADIUSED PARTITIONS ARE TO BE FABRICATED WITH FLEXIBLE STUD RUNNERS, TOP H.
ASTM C754.
INSTALL SYSTEM IN ACCORDANCE WITH ASTM C840, ASTM C1396, ASTM C645, ASTM A653, AND G.
PROVIDE CEMENTITIOUS BACKER BOARD IN ALL AREAS TO RECEIVE TILE IN WET AREAS.F.
PERPENDICULAR TO THE UNDERLYING LAYER.
AT WORK TO RECEIVE MULTIPLE LAYERS OF GYPSUM BOARD, EACH LAYER IS TO BE INSTALLED E.
PROVIDE TAPERED GYPSUM BOARD, UNLESS INDICATED OTHERWISE.D.
BREAK METAL AS INDICATED.EXPANSION JOINTS:3.
USG DURABEAD REINFORCED.CORNER BEADS:2.
USG 200-B METAL TRIM OR EQUAL.CASING BEADS:1.
TRIM ACCESSORIES:C.
MANUFACTURER"S INSTALLATION INSTRUCTIONS FOR EACH PRODUCT PROPOSED FOR USE.3.
TWO (2) 12" X 12" OF EACH GYPSUM BOARD FINISH TEXTURE.2.
PRODUCT DATA ON METAL FRAMING, GYPSUM BOARD, JOINT TAPE.1.
SUBMIT THE FOLLOWING:B.
REFER ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
SECTION 09 65 00 - RESILIENT FLOORING
[DESIGNER NOTE: DEFINE ORIENTATION OF TILE ON FINISH PLAN.]
PROVIDE 5% ATTIC STOCK OF EACH SCHEDULED FINISH.H.
MANUFACTURER'S PRINTED INSTRUCTIONS.
WAX, NUMBER OF COATS AND BUFFING PROCEDURES IN COMPLIANCE WITH THE FLOORING
THOROUGHLY CLEAN FLOORS AND ACCESSORIES. APPLY WAX AND BUFF WITH THE TYPE OF
AFTER COMPLETION OF PROJECT AND JUST PRIOR TO THE FINAL INSPECTION OF THE WORK, G.
PROVIDE RESILIENT REDUCER STRIPS AT FLOORING MATERIAL JUNCTURES.F.
JOINTS, FREE OF GAPS, BUBBLES, AND TEARS.
APPLY ALL FLOOR COVERINGS PER MANUFACTURER'S RECOMMENDATIONS, WITH TIGHT BUTTED E.
PROVIDE FLOOR FILL AS REQUIRED PER MANUFACTURER'S RECOMMENDATIONS.D.
MSDS DATA OF MANUFACTUER'S RECOMMENDED ADHESIVES.4.
MAINTENANCE DATA (TO BE INCLUDED IN OPERATING AND MAINTENANCE MANUAL).3.
THREE (3) SAMPLES OF EACH SCHEDULED TILE.2.
PRODUCT DATA FOR EACH TYPE OF PRODUCT SPECIFIED.1.
SUBMIT THE FOLLOWING:C.
REFER TO FINISH SCHEDULE FOR PRODUCT SPECIFICATIONS.B.
REFER ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
SECTION 09 90 00 - PAINTING
PROVIDE ATTIC STOCK OF ONE (1) GALLON, EACH OF SPECIFIED PAINT.K.
RETOUCH OR REFINISH PAINTED FINISHES DAMAGED BY SUBSEQUENT WORK.J.
COLOR.
UNDERCOATER AND TWO (2) COATS OF ALKYD SEMI-GLOSS ENAMEL TO MATCH SPECIFIED
INTERIOR WOOD TO RECEIVE PAINTED FINISH TO BE FINISHED WITH ONE (1) COAT OF ENAMEL I.
(2) COATS OF SEMI-GLOSS ENAMEL AS SPECIFIED / SCHEDULED UNLESS OTHERWISE NOTED.
INTERIOR FERROUS METALS ARE TO RECEIVE ONE COAT OF PRIMER (SPRAY FINISH) AND TWO H.
BETWEEN COATS TO ACHIEVE REQUIRED FINISH.
APPLYING FOLLOWING COAT UNLESS OTHERWISE DIRECTED BY MANUFACTURER. SAND LIGHTLY
TEXTURE. PAINT IS TO BE ROLLED FLAT, NOT STIPPLED. ALLOW EACH COAT TO DRY BEFORE
COATS OF FINISH PAINT AS SPECIFIED / SCHEDULED. ALL SURFACES ARE TO BE SMOOTH, NO
ALL DRYWALL SURFACES ARE TO RECEIVE ONE (1) COAT OF PRIMER / SEALER AND TWO (2) G.
ALL PAINT IS TO BE APPLIED PER MANUFACTURER’S RECOMMENDATIONS.F.
CODE REQUIRED LABELS, OR EQUIPMENT IDENTIFICATION.
AND SIMILAR ITEMS BEFORE PAINTING. DO NOT PAINT ANY MOVING PARTS OF OPERATING UNITS,
REMOVE OR OTHERWISE PROTECT FINISH HARDWARE, ACCESSORIES, PLATES, LIGHTING FIXTURES E.
SAND SMOOTH AND FLUSH WITH SURFACE.
FILL NICKS, GOUGES, AND OTHER MINOR IMPERFECTIONS IN SURFACES WITH LATEX FILLER, AND D.
SUBSTRATE.
THREE (3) 18" X 18" SAMPLES OF EACH SCHEDULED FINISH / COLOR ON SCHEDULED 2.
PRODUCT DATA.1.
SUBMIT THE FOLLOWING:C.
REFER TO FINISH SCHEDULE FOR PRODUCT SPECIFICATIONS.B.
REFER ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
SECTION 07 84 00 - FIRE STOPPING
CODES.
MATERIALS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND ALL APPLICABLE E.
(NATIONAL ELECTRIC CODE)
MATERIALS SHALL MEET THE REQUIREMENTS OF NFPA 101 (LIFE SAFETY CODE) AND NFPA 70 D.
CONSTRUCTION IN WHICH THE JOINT OCCURS.
E-119, BUT NOT LESS THAN THAT EQUALING THE FIRE-RESISTANCE RATING OF THE
PROVIDE JOINT SEALANTS WITH FIRE-RESISTANCE RATINGS INDICATED, AS DETERMINED BY ASMT C.
DIRECTORY.
CONSTRUCTIONS PENETRATED. MATERIALS ARE TO BE CLASSIFIED IN U.L.'S BUILDING MATERIALS
E-814 (UL 1479), BUT NOT LESS THAN THAT EQUALING THE FIRE-RESISTANCE RATING OF THE
MATERIAL OR COMBINATION OF MATERIALS SHALL MEET THE REQUIREMENTS SPECIFIED IN ASTM B.
INSTRUCTIONS.
SUBMIT PRODUCT DATA, SAMPLES, CERTIFICATES AND MANUFACTURER'S INSTALLATION A.
SECTION 07 90 00 - JOINT SEALERS
PROVIDE TWO (2) YEAR WARRANTY.C.
ASTM C-834.
GENERAL CAULKING AS PART OF INTERIOR PAINTING COMPLY WITH ACRYLIC LATEX4.
(PAINTABLE) SUBJECT TO MOVEMENT.
GENERAL CAULKING AS PART OF INTERIOR PAINTING IN JOINTS SILICONE3.
ADJACENT TOPS & WALLS. COMPLY WITH ASTM C-920.
SEALING OF JOINTS BETWEEN COUNTER SPLASHES AND (GEN. PURPOSE) SILICONE2.
MATERIALS. COMPLY WITH ASTM C-920.
AT JUNCTURES BETWEEN THIS MATERIAL AND ADJACENT LEVELING)
HORIZONTAL CONTROL JOINTS IN CONCRETE FLOORING AND (SELF POLYURETHANE1.
APPLICATIONSEALANT TYPE
MATERIALS:B.
LINE OF COLOR SELECTIONS.
SUBMIT TWO SAMPLES 1/4" IN DIAMETER X 4" IN SIZE ILLUSTRATING MANUFACTURER'S FULL 2.
LIMITATIONS, COLOR AVAILABILITY AND APPLICATION INSTRUCTIONS.
PRODUCT DATA INDICATING SEALANT CHEMICAL CHARACTERISTICS, PERFORMANCE CRITERIA, 1.
SUBMIT THE FOLLOWING PRODUCT INFORMATION.A.
SECTION 08 11 16 - ALUMINUM DOORS AND FRAMES
WARRANT FINISH, OTHER THAN NORMAL WARRANTY, FOR A PERIOD OF 5 YEARS.G.
WARRANT AGAINST DEFECTS IN MANUFACTURING OF MATERIALS FOR A PERIOD OF 2 YEARS.F.
AND APPROVED SHOP DRAWINGS.
INSTALLATION SHALL COMPLY WITH FRAME AND DOOR MANUFACTURER'S PRINTED INSTRUCTIONS E.
REFER TO DOOR SCHEDULE FOR FINISH.D.
[ ] OTHER OR EQUAL, AT ALL NON-RATED / 20 MINUTE RATED ASSEMBLIES.
[ ] FRAMEWORKS SERIES 1
PRODUCT IS TO BE EQUAL TO BE:C.
FOR ARCHITECT'S SELECTION.
SUBMIT SAMPLES OF MANUFACTURER'S FULL COLOR RANGE OF GASKETS / FELT STRIPS 4.
MANUFACTURERS INSTALLATION INSTRUCTIONS.3.
HARDWARE REQUIREMENTS.
SUBMIT FRAME SCHEDULE INDICATING FRAME TYPES, DIMENSIONS, SWING, LABEL AND 2.
PRODUCT DATA FOR DOOR, SIDELIGHT AND STOREFRONT FRAMES.1.
SUBMIT THE FOLLOWING:B.
SEE ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
SECTION 09 51 00 - ACCOUSTICAL CEILINGS
PROVIDE TWO YEAR GUARANTEE OF PRODUCT / INSTALLATION.H.
PROVIDE ATTIC STOCK OF ONE CARTON OF ACOUSTIC TILE PER 10,000 SF.G.
LEVEL SURFACE SHALL BE 1/8" IN 10'-0" MAX.
INSTALL ACOUSTICAL TILE PER MANUFACTURER'S INSTRUCTIONS. VARIATION FROM FLAT AND F.
INSTALL GRID SYSTEM IN ACCORDANCE WITH ASTM C635.E.
SMOKE DEVELOPED: 50 OR LESS.b.
FLAME SPREAD: 25 OR LESS.a.
WITH ASTM E1264 FOR CLASS A PRODUCTS.
SURFACE BURNING CHARACTERISTICS: AS FOLLOWS, TESTED PER ASTM E84 AND COMPLYING 1.
WITH APPROPRIATE MARKINGS OF APPLICABLE TESTING AND INSPECTING ORGANIZATION.
ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. IDENTIFY ACOUSTICAL CEILING COMPONENTS
METHOD INDICATED BELOW, BY UL OR OTHER TESTING AND INSPECTING ORGANIZATIONS
THOSE TESTED FOR THE FOLLOWING FIRE-PERFORMANCE CHARACTERISTICS, PER ASTM TEST
FIRE-PERFORMANCE CHARACTERISTICS: PROVIDE ACOUSTICAL CEILINGS THAT ARE IDENTICAL TO D.
SUBMIT MANUFACTURER'S CERTIFICATION AND INSTALLATION INSTRUCTIONS.3.
EDGE TRIM.
SUBMIT THREE (3) SAMPLES OF SUSPENSION SYSTEM MAIN AND CROSS RUNNER AS WELL AS 2.
AND FINISH.
SUBMIT THREE (3) SAMPLES OF EACH ACOUSTICAL CEILING TYPE ILLUSTRATING MATERIAL 1.
SUBMIT THE FOLLOWING:C.
SPECIFICATIONS OF SUSPENDED ACOUSTIC TILE, GRID AND ASSOCIATED ACCESSORIES.
REFER TO REFLECTED CEILING PLAN AND/OR FINISH SPECIFICATIONS FOR PRODUCT(S) B.
REFER ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
SECTION 09 65 13 - RESILIENT WALL BASE AND ACCESSORIES
PROVIDE 5% ATTIC STOCK OF EACH SCHEDULED BASE.J.
FLOOR COVERINGS THAT WOULD OTHERWISE BE EXPOSED.
SUBSTRATES THROUGHOUT LENGTH OF EACH PIECE. INSTALL REDUCER STRIPS AT EDGES OF
RESILIENT MOLDING ACCESSORIES: BUTT TO ADJACENT MATERIALS AND TIGHTLY ADHERE TO 2.
FLUSH JOINT BETWEEN UNITS.
FOR TREADS INSTALLED AS SEPARATE, EQUAL-LENGTH UNITS, INSTALL TO PRODUCE A c.
TIGHTLY ADHERE SUBSTRATES THROUGHOUT LENGTH OF EACH PIECE.b.
TO TREAD CONTOURS.
USE STAIR-TREAD-NOSE FILLER TO FILL NOSING SUBSTRATES THAT DO NOT CONFORM a.
RESILIENT STAIR ACCESSORIES:1.
RESILIENT ACCESSORY INSTALLATION:I.
SUBSTRATE.
FORMED. SHAVE BACK OF BASE WHERE NECESSARY TO PRODUCE A SNUG FIT TO
AN INVERTED V-SHAPED NOTCH IN TOE OF WALL BASE AT THE POINT WHERE CORNER IS
INSIDE CORNERS: USE STRAIGHT PIECES OF MAXIMUM LENGTHS POSSIBLE. FORM BY CUTTING 3.
BASE THICKNESS.
DEEP ENOUGH TO PRODUCE A SNUG FIT WITHOUT REMOVING MORE THAN HALF THE WALL
BENDS OCCUR AND REMOVE STRIPS PERPENDICULAR TO LENGTH OF BASE THAT ARE ONLY
PRODUCING DISCOLORATION (WHITENING) AT BENDS. SHAVE BACK OF BASE AT POINTS WHERE
OUTSIDE CORNERS: USE STRAIGHT PIECES OF MAXIMUM LENGTHS POSSIBLE. FORM WITHOUT 2.
RECOMMENDATIONS FOR FORMING MITERED CORNERS.
FOR CONTOURED MILLWORK STYLE RESILIENT BASE, REFER TO MANUFACTURER'S 1.
JOB-FORMED CORNERS:H.
BEFORE INSTALLING STRAIGHT PIECES.
WHERE POSSIBLE PROVIDE AND INSTALL PRE-MOLDED CORNERS. INSTALL PRE-MOLDED CORNERS G.
CONTINUOUS CONTACT AT HORIZONTAL AND VERTICAL FINISHES.
TIGHTLY BOND BASE TO BACKING THROUGHOUT THE LENGTH AND HEIGHT OF EACH PIECE WITH F.
OF GAPS, BUBBLES, AND TEARS.
INSTALL BASE IN AS LONG OF LENGTHS AS IS PRACTICABLE WITH TIGHT, BUTTED JOINTS, FREE E.
ROOMS OR AREAS WHERE BASE IS SCHEDULED.
APPLY RESILIENT BASE TO WALLS, COLUMNS, CASEWORK AND OTHER PERMANENT FIXTURES IN D.
LENGTHS.
THREE (3) SAMPLES OF EACH BASE INDICATING STYLE, COLOR AND SIZE IN MINIMUM 12" 2.
PRODUCT DATA.1.
SUBMIT THE FOLLOWING:C.
REFER TO FINISH SCHEDULE FOR PRODUCT SPECIFICATIONS.B.
REFER ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
SECTION 08 31 00 - ACCESS DOORS
RECOMMENDATIONS.
PANELS SHALL BE FINISHED TO MATCH ADJACENT FINISH SURFACE, OR PER ARCHITECT'S D.
ASTM E-119 OR UL 263 FOR HORIZONTAL ACCESS DOORS AND FRAMES.2
NFPA 252 OR UL 10B FOR VERTICAL ACCESS DOORS AND FRAMES.1.
AUTHORITIES HAVING JURISDICTION:
LISTED AND LABELED BY UL OR ANOTHER TESTING AND INSPECTING AGENCY ACCEPTABLE TO
FIRE-TEST-RESPONSE CHARACTERISTICS PER THE FOLLOWING TEST METHOD, AND THAT ARE
COMPLYING WITH NFPA 80 THAT ARE IDENTICAL TO ASSEMBLIES TESTED FOR
WHERE ACCESS DOORS ARE REQUIRED IN FIRE-RATED CONSTRUCTION, PROVIDE ASSEMBLIES C.
INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS AND ATTACHMENTS TO OTHER WORK.
PANEL LOCATIONS / SIZES AND PRODUCT DATA TO ARCHITECT FOR REVIEW AND APPROVAL.
UPON AWARD OF PROJECT AND PRIOR TO BEGINNING WORK, SUBMIT DRAWING OF ALL ACCESS B.
TRADES ALL REQUIRED ACCESS PANEL LOCATIONS, SIZES AND FIRE RATINGS.
PRIOR TO BID, GENERAL CONTRACTOR SHALL COORDINATE WITH HVAC, PLUMBING AND ELECTRICAL A.
SECTION 09 30 00 - TILING
PROVIDE 5% ATTIC STOCK OF ALL STONE TYPES.J.
ON PRE-SEALED SURFACES.
MANUFACTURER'S APPLICATION INSTRUCTIONS. DO NOT ALLOW SEALER TO PUDDLE OR DRY
INCLUDING THE TILE OR STONE SURFACE AND GROUT A SECOND TIME AS INDICATED IN THE
HOURS BEFORE CONTINUING PROCEDURE. AFTER GROUTING, RETREAT THE ENTIRE AREA
MANUFACTURER'S APPLICATION INSTRUCTIONS. ALLOW SEALER TO CURE FOR 12 TO 24
PRIOR TO GROUTING, APPLY PENETRATING SEALER TO ALL SURFACES AND AS INDICATED IN 2.
511 POROUS PLUS:GRANITE (HONED & TEXTURED), MARBLE (HONED), LIMESTONE, CANTERA.b.
SLATE, CERAMIC TILE, QUARRY TILE, PORCELAIN TILE, GRANITE (POLISHED).
511 IMPREGNATOR:MARBLE (POLISHED & TEXTURED), GRANITE (POLISHED), TRAVERTINE, a.
PENETRATING SEALER TYPE AS INDICATED BELOW TO BE LATICRETE OR MIRACLE SEAL 1.
PROVIDE PENETRATING SEALER.I.
USE / APPLICATION.
TYPE TO BE PER THE TILE COUNCIL OF NORTH AMERICA'S RECOMMENDATIONS FOR SPECIFIC
PROVIDE GROUT COLOR(S) AS INDICATED IN FINISH PLANS AND NOTED IN SUBMITTALS. GROUT H.
AND COVED AT CERAMIC TILE.
EDGE OF STONE BASE WITH 1/8" CHAMFER. PROVIDE SQUARE BASE / COVE JOINT AT STONE
SIZE TILE, HEIGHT AS INDICATED ON PLANS AND ELEVATIONS. GRIND & POLISH EXPOSED TOP
PIECES ARE UNAVAILABLE FROM ORIGINAL MANUFACTURER, TILE BASE IS TO BE CUT FROM FULL
CUT TILE AND STONE AS RECOMMENDED BY THE MANUFACTURER. WHEN MANUFACTURED TRIM G.
APPLICATIONS WHERE TILE IS USED.
USE SETTING MATERIALS AS RECOMMENDED BY THE TILE COUNCIL OF NORTH AMERICA FOR F.
AMERICA.
PROVIDE CONTROL JOINTS PER THE RECOMMENDATIONS OF THE TILE COUNCIL OF NORTH
LAY OUT TILE BEFORE SETTING TO ENSURE PROPER SPACING AND ALIGNMENT OF JOINTS. E.
PLANS. INSTALL OVER LEVEL AND PLUMB WALL.
INSTALL OVER MAXIMUM SLOPE IN FLOOR OF 1/8" OVER 10'-0", UNLESS OTHERWISE NOTED IN D.
DIRT, AND WAX, AND MUST BE DRY.
SURFACES TO RECEIVE STONE AND TILE MUST BE FREE OF SEALERS, CURING COMPOUNDS, OIL, C
REQUIRMENTS. (REFER TO A0.00, GENERAL NOTES G16.2.)
DEMONSTRATE EACH CONDITION. COORDINATE WITH ARCHITECT ACTUAL MOCK-UP
GROUT WIDTH. IF MORE THAN ONE GROUT CONDITION IS SPECIFIED, MOCK-UP(S) SHOULD
PROVIDE GROUTED TILE MOCK-UP(S) DEMONSTRATING SPECIFIED GROUT COLOR(S) AND d.
MANUFACTUERS : CUSTOM BUILDING PRODUCTS, INC; TEXRITE; LATICRETE.
[ ]SUBMIT MANUFACTURER'S FULL RANGE OF STANDARD GROUT SAMPLES. ACCEPTABLE
[ ]SUBMIT THREE (3) SAMPLES OF ALL GROUT COLORS AS INDICATED ON FINISH PLANS.c.
SEALER AS SPECIFIED REFER PARAGRAPH J.1.
THREE (3) FULL SIZE TILES OF EACH CERAMIC / PORCELAIN TILE WITH TWO COATS OF b.
OF EACH STONE WITH TWO COATS OF SEALER AS SPECIFIED REFER PARAGRAPH J.1.
TWO (2) SETS OF THREE (3) FULL SIZE TILES INDICATING ACCEPTABLE COLOR RANGE a.
SUBMIT PRODUCT DATA.1.
SUBMIT THE FOLLOWING:B.
REFER ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
5.SUPPORTS:
a.DRYWALL SHELF SUPPORT
1.KNAPE & VOGT #85 ANO STANDARD
2.KNAPE & VOGT #185 ANO BRACKET
b.COAT ROD SHELF SUPPORT
1.KNAPE & VOGT #255 WH STANDARD (RECESSED)
2.KNAPE & VOGT #256S WH CLIPS
c.CABINET SHELF SUPPORT:
1.HAFELE #282.10.700 PINS
2.HAFELE #282.50.704 GROMMETS (1"O.C.)
6.COAT ROD:
a.KNAPE & VOGT #770 1 HEAVY DUTY 1-1/16" O.D. ROD
b.FLANGE: KNAPE & VOGT #757 ANO FOR 1-1/16" O.D. ROD
7.HINGES:
a.FULL OVERLAY: BLUM 125° #91M2650 SC
8.SLIDES:
a.REFER TO SHEET A0.00 FOR SPECIFICATIONS
9.CABINET & DRAWER PULLS:
a.TYPE 1 (TYP. UNO)
1.
10.CABINET LOCKS- TYPICAL AT ALL CABINETS (KEYED ALIKE):
a.DOOR LOCKS
1.
11.GROMMETS (REFER PLANS /ELEVATIONS/ DETAILS FOR LOCATION
a.
F.CABINET DOORS AND DRAWERS:
1.PLASTIC LAMINATE - MINIMUM 3/4" THICK MDFB WITH PLASTIC LAMINATE BOTH FACES OF
DOORS (OUTER FACE OF DRAWERS WITH 3 MM PVC EDGE BANDING ON ALL EDGES.
2.WOOD VENEER- MINIMUM 3/4" THICK MDF CORE PLYWOOD WITH WOOD VENEER ON BOTH
FACES AND ALL EDGES.
G.VENEER PANEL FINISHES TO MATCH APPROVED SAMPLE. FACTORY FINISH ALL PANELS AND
ASSOCIATED TRIM. REFER TO FINISH PLANS AND SPECIFICATIONS FOR VENEER MATCHING CRITERIA.
H.PROTECT MATERIALS DURING HANDLING, DELIVERY AND STORAGE TO PREVENT DAMAGE, SOILAGE
OR DETERIORATION. DO NOT INSTALL DAMAGED MATERIALS. PROTECT MATERIALS AFTER
INSTALLATION TO PRESERVE "LIKE-NEW" APPEARANCE.
I.INSTALLATION: INSTALL PLUMB, LEVEL AND TRUE WITH NO DISTORTIONS. SHIM AS REQUIRED WITH
CONCEALED SHIMS. TOLERANCE TO BE 1/8" PER 8'-0" WITH NO VARIATION IN ADJOINING
SURFACES. CUT TO FIT AND CAREFULLY SCRIBE. NO OVERLAY TRIM TO COVER JOINTS.
J.WHERE APPLICABLE, PREPARE COUNTERTOPS FOR ALL RELATED APPLIANCES AND PLUMBING WORK.
CUT HOLES TO FIT TEMPLATES OF APPLIANCES, FIXTURES, AND ELECTRICAL DEVICES. TRIM
OPENINGS SO ALL CORE MATERIALS ARE COVERED.
REFER TO SHEET A0.00 FOR SPECIFICATIONS
REFER TO SHEET A0.00 FOR SPECIFICATION
SECTION 11 40 00 - FOOD SERVICE EQUIPMENT
REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS.C.
AND SIZES.
SUBMIT PRODUCT DATA LISTING MODEL NUMBERS, COLORS AND ALL PERTINENT PERFORMANCE B.
REFER TO PRODUCT SPECIFICATIONS ON SHEET A0.00.A.
SECTION 12 21 00 - WINDOW TREATMENT
THREE SAMPLES, INDICATING SIZE AND COLOR.2.
MANUFACTURER'S FULL RANGE OF STANDARD COLORS FOR SELECTION BY ARCHITECT.1.
SUBMIT THE FOLLOWING:B.
[ ] PRODUCT TO BE EQUAL TO: ENTER DATA
[ ] PER BUILDING STANDARD REFER TO BUILDING STANDARD SPECIFICATIONS.
COMPLETION.
PROTECT DURING CONSTRUCTION CLEAN, REWORK AND REPAIR PRIOR TO SUBSTANTIAL
TREATMENT TO REMAIN FOR DAMAGED OR MISSING ELEMENTS TO BE REPAIRED OR REPLACED.
[X] EXISTING TO REMAIN. GENERAL CONTRACTOR TO DOCUMENT EXISTING CONDITION OF WINDOW A.
SECTION 08 14 16 - FLUSH WOOD DOORS
PROVIDE TWO (2) YEAR WARRANTY.F.
OTHERWISE. TOUCH-UP DOOR FINISH AFTER UNDERCUTTING.
UNDERCUT DOORS 1/2" (3/4" AT RESTROOMS) MAX. TO FINISHED FLOOR UNLESS NOTED E.
MATCH TENANT SAMPLE. UNLESS NOTED ON DOOR SCHEDULE[X]
FINISH TO BE, REFER TO DOOR SCHEDULE:D.
FABRICATE DOORS IN ACCORDANCE WITH AWI QUALITY STANDARD REQUIREMENTS.C.
THREE (3) 8" X 8" SAMPLES OF DOOR FINISH.3.
PRODUCT DATA.2.
UNDERCUTS REQUIRED, SPECIAL BEVELING ETC.
SHOP DRAWINGS ILLUSTRATING DOOR OPENING CRITERIA ELEVATIONS, SIZES, TYPES, SWINGS, 1.
SUBMIT THE FOLLOWING:B.
SEE ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
LIBERTY - LIB-23909 (ALLOWANCE $4.00)
SECTION 11 52 13 - PROJECTION SCREENS
[X] PROVIDED BY OWNER AND INSTALLED BY CONTRACTOR. PROVIDE BRACING AS REQUIREDB.
REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION(S).A.
SECTION 10 44 00 - FIRE PROTECTION SPECIALTIES
FIRE EXTINGUISHERS TO BE LARSEN'S MANUFACTURING CO. MODEL #MP10.D.
2409-RM.
ALL SEMI-RECESSED FIRE EXTINGUISHER CABINETS TO BE VERTICAL DUO DOOR MODEL #SS 1.
ARCHITECTURAL SERIES:
FIRE EXTINGUISHER CABINETS TO BE EQUAL TO LARSEN'S MANUFACTURING CO.C.
[ ] LOCATIONS AND QUANTITIES AS PER NFPA AND LOCAL CODES AND ORDINANCES.
[ ] REFER TO ARCHITECTURAL FLOOR PLAN FOR LOCATIONS.B.
SUBMIT PRODUCT DATA FOR EACH TYPE OF PRODUCT SPECIFIED.A.
SECTION 10 11 00 - VISUAL DISPLAY UNITS
ENTER DATAMB-2
ENTER DATAMB-1
PRODUCT TO BE AS MANUFACTURED BY:D.
SHOP / FABRICATION DRAWINGS.3.
SAMPLES OF FINISH SURFACES.2.
PRODUCT DATA.1.
SUBMIT THE FOLLOWING:C.
[ ] PROVIDED UNDER THIS SCOPE OF WORK.
[X] FURNISHED BY TENANT AND INSTALLED UNDER THIS SCOPE OF WORK.B.
REFER ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK.A.
SECTION 26 00 00 - ELECTRICAL
AND LEVEL WITH EACH OTHER.
ALL ADJACENT ELECTRICAL / DATA DEVICES SHALL BE INSTALLED HORIZONTALLY CENTERED D.
INSTALLATION PLANS FROM FURNITURE DEALER AND COORDINATE EXACT LOCATION IN FIELD.
FURNITURE WHIPS ARE SHOWN IN APPROXIMATE LOCATIONS, REFER TO FURNITURE C.
ALL ADJACENT SWITCHES SHALL BE CONSTRUCTED IN A SINGLE MULTI-GANG SWITCH BOX.B.
"DECORA" SCREWLESS. IF NO EXISTING ELECTRICAL OUTLETS EXIST, FINISH TO BE WHITE.
ORANGE WITH COVERS TO MATCH ALL OTHER COVERS. DEVICE/COVER STYLE TO BE
OTHERWISE AS SUPPLIED BY THE MANUFACTURER. DEDICATED OUTLET DEVICES ARE TO BE
ALL ELECTRICAL, DATA, AND SWITCH DEVICES AND COVERS TO BE WHITE, UNLESS NOTED A.
SECTION 06 40 00 - INTERIOR ARCHITECTURAL WOODWORK
ADHESIVES AS RECOMMENDED BY MANUFACTURER.4.
COLORS, TEXTURES AND PATTERNS AS INDICATED ON FINISH PLAN.3.
SMOKE DEVELOPED: 450 OR LESS b.
FLAME SPREAD 75 OR LESS a.
WOOD VENEER ONE SIDE WITH TRANSPARENT FINISH. FIRE RESISTANCE TO BE:
WOOD VENEER/ SUBSTRATE: 3/4" THICK WOOD SUBSTRATE OR MDF CORE PLYWOOD WITH 2.
PRODUCT CLASS MD.
ALTERNATE SHALL BE MEDIUM DENSITY FIREBOARD (MDFB) COMPLYING WITH ANSI A208.2,
SOFTWOOD PLYWOOD: PSI GRADED IN ACCORDANCE WITH AWI FOR USE AS A SUBSTRATE. 1.
PRODUCTS / MATERIALS ARE AS FOLLOWS:E.
REQUIREMENTS OF AWI STANDARDS SECTIONS 500 FOR FLUSH WOOD PANELING.
PROVISIONS FOR GRADING AND WORKMANSHIP. IN ADDITION, VENEER PANELING SHALL COMPLY WITH
QUALITY SHALL COMPLY WITH AMERICAN WOODWORKING INSTITUTE (AWI) "PREMIUM GRADE WORK" D.
FLOOR PREPARATION - FLOOR SHALL VARY 1/8" IN 10'-0" MAX BENEATH ALL BASE CABINETS.C.
SUBMIT DATA FOR EACH TYPE OF PRODUCT SPECIFIED.3.
EXPOSED CABINET HARDWARE (ONE UNIT OF EACH TYPE AND FINISH).2.
SUBMIT THREE 12" X 12" FINISHED SAMPLES OF ALL VENEER PANELING/MILLWORK. b.
OF EDGE BAND CONDITION AT DOOR/DRAWER.
SUBMIT THREE SAMPLES OF ALL PLASTIC LAMINATES AS SCHEDULED, AND TWO MOCK-UPS a.
PLASTIC LAMINATE AND OTHER FINISHES AS SCHEDULED.1.
SUBMIT THE FOLLOWING:B.
ELEVATIONS, LARGE-SCALE DETAILS, ATTACHMENT DEVICES AND OTHER COMPONENTS.
PROVIDE SHOP DRAWINGS SHOWING LOCATION OF EACH ITEM, DIMENSIONED PLANS AND A.
SECTION 09 68 00 - CARPET
AND ALCOVES OF ROOMS INDICATED TO BE CARPETED UNLESS ANOTHER FLOOR FINISH.
UNDER OPEN-BOTTOMED AND RAISED-BOTTOM OBSTRUCTIONS. EXTEND CARPET INTO CLOSETS
TO BE DIRECT-GLUED TO FLOOR AS PER MANUFACTURERS RECOMMENDATION. EXTEND CARPET
CARPET, WHERE SCHEDULED, TO BE STRETCHED AS RECOMMENDED BY MANUFACTURER. CARPET I.
DIRECTION FOR PATTERN AND TEXTURE, INCLUDING LAY OF PILE.
COMPLY WITH MANUFACTURER'S PRINTED INSTRUCTIONS AND RECOMMENDATIONS. MAINTAIN H.
BIND OR SEAL CUT EDGES AS RECOMMENDED BY CARPET MANUFACTURER.
BUILT-IN FURNITURE INCLUDING CABINETS, PIPES, OUTLETS, EDGINGS, THRESHOLDS, AND NOSINGS.
CUT AND FIT CARPET TO BUTT TIGHTLY TO VERTICAL SURFACES, PERMANENT FIXTURES, AND G.
CRACKS, AND INDENTIONS, ETC. WITH LEVELING AND PATCHING COMPOUNDS.
RESIDUAL ADHESIVES, ETC. REMOVE RIDGES AND BUMPS, AND FILL DEPRESSIONS, LOW SPOTS,
CLEAN FLOOR OF ALL RESIDUES, INCLUDING, BUT NOT LIMITED TO PAINT, DIRT, OIL, GREASE, F.
RECOMMENDATIONS.
INSTALLATION SHALL COMPLY WITH CRI 104, AND PER MANUFACTURER'S WRITTEN E.
TOXICITY, FLAME SPREAD, SMOKE DEVELOPMENT INDICES, AS WELL AS ACCESSIBILITY.
ENSURE PRODUCT COMPLIES WITH ALL LOCAL STATE AND FEDERAL LAWS AND ORDINANCES FOR D.
AT THE CENTERLINE OF THE DOORS.
SEAMING DIAGRAM. SEAMS PARALLEL TO DOORS (IN CLOSED POSITION) SHALL BE LOCATED 1.
SUBMIT THE FOLLOWING:C.
REFER TO FINISH SCHEDULE FOR PRODUCT SPECIFICATIONS.B.
OF WORK.
TENANT VENDOR TO PROVIDE ALL CARPET. REFER TO ARCHITECTURAL DRAWINGS FOR EXTENT A.
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
4
0
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
0
_
0
1
s
p
e
c
_
n
o
n
c
a
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
A0.02
PERFORMED THAT DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS
MARCUS & MILLICHAP AND STAFFELBACH RESERVE THE RIGHT TO REJECT ANY WORK
2
3
STAFFELBACH WITH AN UPDATED COPY.
CONTRACTOR TO UPDATE ACCORDINGLY AND PROVIDE MARCUS & MILLICHAP AND
CONTRACTOR TO PROVIDE CONSTRUCTION SCHEDULE PRIOR TO DEMOLITION.
1
VENDOR COORDINATION
TENANT CARPET DELIVERY
CARD ACCESS VENDOR INSTALLATION
APPLIANCE/PRODUCT SPECIFICATIONS
BREAK ROOM
MISCELLANEOUS
LOBBY/CONFERENCE AREA/OPEN OFFICE
OF STAFFELBACH.
SUBSTITUTIONS WILL NOT BE ACCEPTABLE WITHOUT WRITTEN CONSENT
NOTE: CONTRACTOR RESPONSIBLE FOR ORDERING ITEMS AS NOTED.
REQUIREMENTS
SPECIFICATIONS &
MARCUS & MILLICHAP
GENERAL CONTRACTOR RESPONSIBILITIES
CONSTRUCTION. CONTRACTOR IS TO NOTIFY STAFFELBACH OF ANY OF THE FOLLOWING:
GENERAL CONTRACTOR IS REQUIRED TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO
BUILDING SYSTEMS.
LIGHTING CONFLICTS WITH MECHANICAL SYSTEMS, SPRINKLERS OR OTHER
FLOOR OUTLET LOCATIONS
DOCUMENTS.
ANY ADDITIONAL CONFLICTS WHICH AFFECT THE DESIGN INTENT OF THESE
BUILDING STANDARD LIGHTING
MULTI-TENANT CORRIDOR FINISHES
DOCUMENTS
BUILDING STANDARD CONDITIONS SPECIFICALLY CALLED OUT IN THESE
BUILDING STANDARD CEILING GRID AND TILE
FOLLOWING EXISTING CONDITIONS:
GENERAL CONTRACTOR IS TO COORDINATE WITH THE BUILDING LANDLORD FOR THE
AS INDICATED ON A4.10
PROVIDE COPPER WATER LINE WITH SHUT-OFF VALVE
TENANT SUPPLIED COFFEE MAKER.
NOTES:
MODEL/DESCRIPTION:
MANUFACTURER:
MODEL/DESCRIPTION:
MANUFACTURER:
MODEL/DESCRIPTION:
MANUFACTURER:
SCGB-1KT GROUNDING BAR KIT
STORM COPPER COMPONENTS
MODEL/DESCRIPTION:
MANUFACTURER:
NOTE:
MODEL:
MANUFACTURER:
SPECIFY THIS AERATOR WHEN ORDERING F-1.
RP19754 (FINISH TO MATCH F-1)
DELTA
91M2650; PARTIAL OVERLAY/TWIN OVERLAY AS APPLICABLE
BLUM
SILVER
DUTY
#85 STANDARDS & #185 BRACKETS, ANACHROME 16" HEAVY
KNAPE & VOGT
COLOR:
MODEL/DESCRIPTION:
MANUFACTURER:
230E SERIES - SINGLE EXTENSION WITH STAY-CLOSED DETENTS; WHITE
BLUM
STAINLESS STEEL
4100 SERIES - LOW PROFILE DRAWER SLIDE; 80 LB. LOAD RATING
KNAPE & VOGT
NOTE:
INDICATED ON A4.10
PROVIDE COPPER WATER LINE WITH SHUT OFF VALVE AS
TOP
G.C. TO ENSURE 1" CLEAR ON EACH SIDE AND 1 „" CLEAR ON
GSHS6KGZSS, STAINLESS STEEL, 69 •" H X 35" D X 35 ƒ" W
GE (GENERAL ELECTRIC) ENERGY STAR
TO BE MOUNTED UNDER COUNTER
INSTA-HOT OR EQUAL REFER TO MEP
NOTE:
MANUFACTURER:
MODEL/DESCRIPTION:
MANUFACTURER:
MODEL/DESCRIPTION:
MANUFACTURER:
NOTE:
NOTE:
MODEL/SIZE:
MANUFACTURER:
FINISH:
SIZE:
MODEL
MANUFACTURER:
STAINLESS STEEL
12 9/32" (D) X 11 3/16" (H) X 23 25/23" (W)
PEM31SMSS
GE COUNTER TOP MICROWAVE OVEN
11 …" HIGH, 6" DIAMETER
BADGER ONE ( 1/3 HORSEPOWER)
IN-SINK-ERATOR
SIZE:
MODEL:
MANUFACTURER:
FINISH:
MODEL/DESCRIPTION:
MANUFACTURER:
CHROME FINISH
441-DST - 2 HOLE APPLICATION
DELTA - COLLINS SERIES
STAINLESS STEEL
32 11/32"H X 24"D X 25‚"W
GLDT696DSS
GE (GENERAL ELECTRIC) ENERGY STAR
FINISH:
SIZE:
MODEL:
MANUFACTURER:
FINISH:
SIZE:
MODEL:
MANUFACTURER:
STAINLESS STEEL
25"L x 21 ‚"W x 5 …"D INSIDE BOWL
#GECR2521 (MR2)
ELKAY - SINGLE BOWL
PS-1: MANUAL PROJECTION SCREEN AND PULL ROD:
PTD-1: FLUSH POKE-THRU DEVICE: RECEPTION DESK
PTD-2: FLUSH POKE-THRU DEVICE: COPIER
WH-1: WATER HEATER:
SK-1: SINK:
RF-1: REFRIGERATOR:
MW-1: MICROWAVE:
H-1: CABINET HINGES:
GD-1: GARBAGE DISPOSAL:
AR-1: AERATOR - 1.5 GPM:
FC-1: FAUCET:
DW-1: DISHWASHER:
CM-1: COFFEE MAKER:
DG-1: DRAWER GLIDES:
DG-2: DRAWER GLIDES
CH-1: DOOR COAT HOOK - PRIVATE OFFICES
B-1: BRACKETS & STANDARDS - STORAGE ROOMS
GB-1: SERVER ROOM GROUNDING BAR
FINISH:
MODEL/DESCRIPTION:
MANUFACTURER:
CP-1: CABINET PULLS
PTD-3: FLUSH POKE-THRU DEVICE: MULTIPLE WORKSTATIONS
PTD-4: FLUSH POKE-THRU DEVICE: MULTIPLE WORKSTATIONS
NOTE:
NOTE:
FINISH:
MODEL:
MANUFACTURER:
PTD-5: FLUSH POKE-THRU DEVICE: SINGLE WORKSTATION
REFER A1.31 FOR LOCATION AND DETAILS
COMBINATION DEVICE FOR POWER AND DATA
BLACK
4FFATC
WIREMOLD
DOOR AS INDICATED ON SHEET A1.20
COAT HOOK TO BE CENTERED HORIZONTALLY AT 72" AFF ON BACK OF
POLISHED CHROME
MODEL #2038
PETER PEPPER
NOTE:
FINISH:
MODEL/DESCRIPTION:
MANUFACTURER:
FINALIZATION OF THE PUNCH LIST.
RESCHEDULED IN A TIMELY MANNER. CONFERENCE CALLS SHALL BE CONDUCTED UNTIL
CONFERENCE CALLS. IF CONTRACTOR CANNOT BE PRESENT THE MEETING SHALL BE
CONTRACTOR TO COORDINATE WITH MARCUS & MILLICHAP AND STAFFELBACH FOR WEEKLY
REQUIRED PROJECT CORRESPONDENCE
4
REQUIRED PROJECT DOCUMENTATION
1
2
3
REQUIRED PROJECT COORDINATION
1
2
3
FOLLOWING:
GENERAL CONTRACTOR IS TO COORDINATE WITH MARCUS & MILLICHAP FOR THE
TENANT CARPET DELIVERY
CARD ACCESS VENDOR INSTALLATION
TENANT CABLE COMPANY (ROUGH CABLING)
4
SYSTEMS FURNITURE POWER FEED DELIVERY
SYSTEMS FURNITURE DELIVERY
NOTES:
FINISH:
MODEL:
MANUFACTURER:
" ACTUAL HOLE DIAMETER)16
1REQUIRED 3" CORE HOLE (3
ASSEMBLY PLATE TO MAINTAIN FIRE CLASSIFCATION
WITH A CONDUIT CONNECTOR (NOT INCLUDED) AT THE ADAPTER
THREADED CONDUIT OPENINGS AND CLOSURE PLUGS. MUST BE USED
UNIT IS COMPLETE WITH COMBINATION 1‚" AND 2" TRADE SIZE
REFER A1.31 FOR LOCATION AND DETAILS
DEVICE FOR DATA
BLACK
RC9AM2TC
WIREMOLD
NOTES:
FINISH:
MODEL:
MANUFACTURER:
" ACTUAL HOLE DIAMETER)16
1REQUIRED 3" CORE HOLE (3
ASSEMBLY PLATE TO MAINTAIN FIRE CLASSIFCATION
WITH A CONDUIT CONNECTOR (NOT INCLUDED) AT THE ADAPTER
THREADED CONDUIT OPENINGS AND CLOSURE PLUGS. MUST BE USED
UNIT IS COMPLETE WITH COMBINATION 1‚" AND 2" TRADE SIZE
REFER A1.31 FOR LOCATION AND DETAILS
DEVICE FOR POWER
BLACK
RC9AM2TC
WIREMOLD
2 DUPLEX OUTLETS AND 1 DATA OUTLET (6ACT8A)
6" DIAMENTER CORE
WIREMOLD 6AT - 6ATCBK
LEGRAND
4" DIAMETER CORE WITH NEMA 5-20R AND DATA
WIREMOLD RC4
LEGRAND
COORDINATION CHECKLIST
TENANT/ARCHITECT
RCP AND POWER PLANS FOR TENANT A/V VENDOR
CABLING PLANS FOR CABLING VENDOR
CARD READER PLAN
ARCHITECT/FURNITURE VENDOR
CAD BACKGROUNDS
APPROVAL OF SYSTEMS FURNITURE LAYOUT
DATE
DATE
DATE
DATE
DATE
DATE
APPROVAL OF CABLING PLANS
CAD BACKGROUNDS
ARCHITECT/GENERAL CONTRACTOR
DATE
(SUBMITTALS ON A0.02)
REQUIRED DOCUMENTATION
CARPET SEAMING PLAN (PROVIDE YARDAGE REQUIRED FOR CARPET/CARPET BASE)
G.C. TO PROVIDE TENANT A FORMAL WARRANTY FOR ALL WORKMANSHIP.
DIGITAL PROGRESS PHOTOS PRIOR TO WEEKLY CONSTRUCTION CALLS
INFORMATION FOR EQUIPMENT (TO INCLUDE WORKMANSHIP) AT TIME OF PUNCH-LIST
G.C. TO PROVIDE TENANT WITH CLOSE OUT BINDER TO INCLUDE ALL MANUALS AND WARRANTY
SUBMITTALS
DISCLAIMER
TENANT FURNITURE DELIVERY
PROJECT SCHEDULE
REQUIRED SUBMITTALS
PRIOR TO TIMELY ORDERING. A SUMMARY OF (BUT NOT LIMITED TO) SUBMITTALS
INCLUDING MECHANICAL AND ELECTRICAL EQUIPMENT, CUT SHEETS FOR ALL
FIXTURES AND EQUIPMENT AND SAMPLES OF ALL FINISHES TO STAFFELBACH
THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL FABRICATED ITEMS
REQUIRED UNDER THE ARCHITECTURAL SCOPE OF WORK ARE AS FOLLOWS.
DRAWINGS SAMPLE DATA
ARCHITECTURAL WOODWORK
WOOD DOORS
SPECIALTY DOORS & FRAMES
DOOR HARDWARE
TILING
RESILIENT FLOORING
RESILIENT BASE
WALL COVERING
PAINTING AND COATING
APPLIANCES
LIGHTING
GLAZING
CARPET SEAMING DIAGRAM
COMPLETED WORK.**
**NON-COMPLIANCE TO THE SUBMITTAL PROCESS MAY RESULT IN THE REJECTION OF
FIRE STROBE LOCATIONS
WOOD DOOR STAIN (WD-1)
PLUMBING FIXTURES
GROUT
**CONTRACTOR IS TO SUBMIT APPLIANCE SUBMITTAL PRIOR TO MILLWORK SUBMITTALS.**
SUBMITTAL CHECKLIST
ARCHITECTURAL WOODWORK
WOOD DOORS
SPECIALTY DOORS & FRAMES
DOOR HARDWARE
TILING
RESILIENT FLOORING
RESILIENT BASE
WALL COVERING
PAINTING AND COATING
APPLIANCES
LIGHTING
GLAZING
CARPET SEAMING DIAGRAM
WOOD DOOR STAIN (WD-1)
PLUMBING FIXTURES
GROUT
BY G.C.
DATE SUBMITTED
ACTION
RETURNED/
RFI LOG
TO BE COMPLETED ON HARD COPY CD'S
TO BE COMPLETED ON HARD COPY CD'S
TO BE COMPLETED ON HARD COPY CD'S
SUBJECT RETURNED
DATE
SUBMITTED
DATE
RFI#
1 SUBJECT xx.xx.xx xx.xx.xx
FEC-1: SEMI-RECESSED FIRE EXTINGUISHER CABINET
MODEL:
DESCRIPTION:
MANUFACTURER:
SS 2409-RM
VERTICAL DUO DOOR WITH CLEAR ACRYLIC GLASS
LARSENS
GENERAL PRICING NOTES
A CASE-BY-CASE BASIS.
SUBSTITUTIONS. SUBSTITUTIONS BASED ON PRODUCT AVAILABILITY WILL BE CONSIDERED ON
CONTRACTOR IS TO BID CONSTRUCTION DOCUMENTS AS NOTED IN THESE DRAWINGS. NO
CEILING TILE
FIRE STROBE LOCATIONS
CEILING TILE
MEETING MINUTES
NOT BE ACCEPTED UNLESS REQUESTED BY MARCUS & MILLICHAP.
BETWEEN CONSTRUCTION DOCUMENTS AND EXISTING CONDITIONS. CHANGE ORDERS WILL
CONTRACTOR TO NOTIFY THE ARCHITECT IMMEDIATELY SHOULD DISCREPANCIES BE FOUND
INTENT OF THESE DRAWINGS.
THE SPACE TO CONFIRM THAT EXISTING CONDITIONS ARE NOT IN CONFLICT WITH THE DESIGN
PRIOR TO BEGINNING OF CONSTRUCTION, THE GENERAL CONTRACTOR IS REQUIRED TO WALK
TENANT CABLE COMPANY (ROUGH & FINISH CABLING)
TENANT FURNITURE
TENANT FURNITURE TO BE PROVIDED BY M3
PRIMARY CONTACT AT M3:
PHONE: 626.441.0300
GEORGIA ALTMAYER
TENANT FREESTANDING RECEPTION DESK TO BE PROVIDED BY M3
NO COST TO THE TENANT.
COMPLY WITH THE SUBMITTAL PROCESS MAY RESULT IN REJECTION OF COMPLETED WORK. AT
DESIMINATE REQUIRED SHOP DRAWINGS/SUBMITTALS FOR MEP APPROVAL. FAILURE TO
ENGINEERING SUBMITTALS WILL BE TRANSMITTED TO STAFFELBACH - STAFFELBACH WILL
CONTRACTOR TO SUBMIT ALL REQUIRED SHOP DRAWINGS/SUBMITTALS TO STAFFELBACH. ALL
FOLLOWING:
GENERAL CONTRACTOR IS TO COORDINATE WITH MARCUS & MILLICHAP FOR THE
5
(M3) FOR THE FOLLOWING:
GENERAL CONTRACTOR IS TO COORDINATE WITH MARCUS & MILLICHAP'S FURNITURE VENDOR
TO BE PROVIDED BY TENANT AND INSTALLED BY G.C.
TO BACK OF SCREEN. USE WHITE TRIM KIT.
REFER TO SHEET A1.40 FOR LOCATION. MOUNT 7" FROM FACE OF WALL
54" H x 96" W HDTV FORMAT, MATTE WHITE
DA-LITE, ADVANTAGE MANUAL WITH CSR
CABINETS, BREAK ROOM, COPY ROOM, & STORAGE ROOM SHELVING) AS SHOWN ON CDS.
CONTRACTOR BASE QUOTE TO INCLUDE THE FOLLOWING MILLWORK (ALL BASE/UPPER
CONFERENCE CALLS (MEETING MINUTES) WITHIN 48 HOURS AFTER CONSTRUCTION MEETINGS
CONTRACTOR TO PROVIDE ARCHITECT/TENANT A SUMMARY OF ALL CONSTRUCTION
CONSTRUCTION KICK-OFF CONFERENCE CALL WITH ARCHITECT/MARCUS & MILLICHAP.
PRIOR TO CONSTRUCTION COMMENCING GENERAL CONTRACTOR IS TO COORDINATE A
LONG AS RESOLUTION IS DOCUMENTED IN MEETING MINUTES
CONTRACTOR MAY SUBMIT VERBAL QUESTIONS DURING WEEKLY CONSTRUCTION CALLS. AS
INFORMAL VIA EMAIL FOR STAFFELBACH'S DOCUMENTATION PURPOSES. EXCEPTION -
GENERAL CONTRACTOR IS REQUIRED TO SUBMIT ALL QUESTIONS BOTH FORMAL (RFI'S) AND
NOTE:
FINISH:
MODEL:
MANUFACTURER:
REQUIRED PROJECT SCHEDULE
PRIOR TO EVERY WEEKLY CONSTRUCTION MEETING.
CONTRACTOR IS REQUIRED TO MAINTAIN AN UPDATED PROJECT SCHEDULE AND SUBMIT
CONTRACTOR IS TO RESUBMIT THE REVISED PROJECT SCHEDULE WITHIN 2 BUSINESS DAYS.
CORRECTIONS BE MADE TO THE PROJECT SCHEDULE BY MARCUS & MILLICHAP THE
MARCUS & MILLICHAP MUST APPROVE OF THE PROPOSED PROJECT SCHEUDLE. SHOULD ANY
MILLICHAP'S REVIEW WITHIN ONE WEEK OF PROJECT AWARD.
CONTRACTOR TO SUBMIT A CONSTRUCTION PROJECT SCHEDULE FOR MARCUS &
USE COUNTERSUNK FLAT HEAD SCREWS
CHROME
LIB-23909
LIBERTY
SERVER ROOM
CONFERENCE ROOM CORES
SEVERAL OPEN OFFICE PHOTOS
RECEPTION
BREAK/COPY
LARGE CONFERENCE
TYPICAL PRIVATE OFFICE FRONT SHOWING INTERIOR
DESIGN INTENT. CONSTRUCTION PHOTOS TO INCLUDE:
WILL BE REJECTED IF QUALITY OF PROVIDED PHOTOS IS NOT CLEAR ENOUGH TO VERIFY
CONFERENCE CALL (WITHIN 2 HOURS PRIOR TO SCHEDULED CONFERENCE CALL). PHOTOS
CONTRACTOR TO PROVIDE CONSTRUCTION PHOTOS PRIOR TO EACH WEEKLY SCHEDULED
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
4
3
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
0
_
0
2
s
p
e
c
_
M
M
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
GENERAL NOTE TO THE CONTRACTOR:
TO BEGINNING THEIR WORK.
ARCHITECTURAL AND ENGINEERING DRAWINGS PRIOR
SUBCONTRACTORS HAVE REVIEWED BOTH
GENERAL CONTRACTOR SHALL VERIFY THAT ALL
MARCUS & MILLICHAP DEEMS APPROPRIATE.
CONTRACTORS EXPENSE TO CORRECT THE WORK AS
RESULT IN REJECTION OF WORK AT THE GENERAL
FAILURE TO COMPLY WITH THIS REQUIREMENT MAY
REQUIREMENTS.
ADDITIONAL MARCUS & MILLICHAP SPECIFIC
GENERAL CONTRACTOR TO REFER TO A0.02 FOR
CONSTRUCTION DOCUMENTS IS UNCLEAR.
THE EVENT THAT THE DESIGN INTENT OF THESE
GENERAL CONTRACTOR TO SUBMIT WRITTEN RFI'S IN
RESOLUTION.
IMMEDIATELY NOTIFY STAFFELBACH (IN WRITING) FOR A
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO
ARCHITECTURAL DRAWINGS ARE IN CONFLICT IT IS THE
IN THE EVENT THAT THE ENGINEERING AND
WITH DESIGN INTENT.
CONSTRUCTION DOCUMENTS TO INSURE COMPLIANCE
SUBCONTRACTORS WITH A COMPLETE SET OF
GENERAL CONTRACTOR WILL PROVIDE ALL
THEIR TRADE.
DRAWINGS FOR DESIGN INTENT AS IT PERTAINS TO
REVIEWING ARCHITECTURAL AND ENGINEERING
EACH SUBCONTRACTOR IS RESPONSIBLE FOR
ENGINEERING DRAWINGS.
DRAWINGS SUPERCEDE LOCATIONS SHOW ON
SPECIFIC LOCATIONS OF DEVICES ON ARCHITECTURAL
CONTRACT IS AWARDED
LIGHTING, STONE FLOORING, ETC.) AS SOON AS
LONG LEAD ITEMS (I.E. ALUMINUM FRAMING, DOORS,
GENERAL CONTRACTOR TO IDENTIFY AND ORDER ALL
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
4
5
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
.
0
0
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
10 floor 5
" = 1'-0"8
1
NORTH
PLAN
OFFICEOFFICEOFFICERM OFFICE
OFFICE OFFICE OFFICEBREAK/COPY STORAGE
OFFICE
SERVER RECEPTION
COAT
CONFERENCE
SMALL
OFFICEOFFICE
CONFERENCE
LARGE
514 515 516 517 518
501 500
513 512 511 510 509 508 507 503
502
505 504
STOR.
FEC
OFFICE
OPEN
506
OFFICE
OPEN
519
FEC
0 4 8 16 32
A1.00
1.
2.
0204
LIFE SAFETY PLAN
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY
PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND
LIFE SAFETY PLAN
LIFE SAFETY NOTES
INTERNATIONAL FIRE CODE, NFPA).
DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (IBC,
SPEAKERS, SMOKE DETECTORS, FIRE PULLS AND ANY OTHER REQUIRED ALARM &
PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY
3.
RENOVATION OF THE FIRE SPRIKLER SYSTEM.
STAFFELBACH IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION OR
THE GENERAL CONTRACT PROVIDE A COMPLETE WORKING SYSTEM.
FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER
4.
LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
AND SHALL FILE THOSE DRAWINGS AND RELATED DOCUMENTS WITH STATE AND
THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS
5.
ANY POINT TO A VISIBLE FIRE EXTINGUISHER.
NEW AS SPECIFIED ON SHEET A0.02. MAXIMUM TRAVEL DISTANCE OF 75' FROM
FIRE EXTINGUISHER CABINETS. ALL FIRE EXTINGUISHER CABINETS ARE TO BE
KEYED NOTES
01
WITH LANDLORD.
EXTINGUISHERS, ALARM NOTIFICATION SYSTEMS ARE TO REMAIN. COORDINATE
EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE PULLS, FIRE
01
01
01
01
02 REFER TO A7.10 FOR EMERGENCY LIGHTING
02
02
CODE SUMMARY
THIS BUILDING IS SPRINKLED
SCOPE OF WORK TENANT FINISH OUT
OCCUPANCY CLASSIFICATION B
TOTAL BUILDING AREA ?
4,631 USFTOTAL PROJECT AREA
NUMBER OF REQUIRED EXITS 2
TOTAL AREA OF ACCESSORY USES 0
EX
EX
EXEX
EX
EP
EP
EX EXISTING EXIT
EXISTING ELECTRICAL PANEL
EXIT SIGNAGE
FEC
FIRE EXTINGUISHER
SYMBOLS LEGEND
123'-†" LONGEST DIAGONAL
70'-1‚" BETWEEN EXITS
41' MINIMUM
42
LOAD
OCCUPANCY 39 OCCUPANTS 21 OCCUPANTS
CAPACITY 240
EXIT WIDTH: 36"
CAPACITY 240
EXIT WIDTH: 36"
OFFICE AREA:4,109
CONFERENCE ROOMS:522
OCCUPANCY CALCULATIONS
SQUARE FOOTAGE
OFFICE AREA:
CONFERENCE ROOMS:A-1
OCCUPANCY GROUP B
OFFICE AREA:
CONFERENCE ROOMS:
OCCUPANCY FACTOR 100 SF/PERSON
15 SF/PERSON
OFFICE AREA:
CONFERENCE ROOMS:
OCCUPANCY LOAD
42
35
77TOTAL:
38 OCCUPANTS
35
LOAD
OCCUPANCY
CONFERENCE
35
LOAD
OCCUPANCY
CONFERENCE
18 OCCUPANTS
CAPACITY 180
EXIT WIDTH: 36"
CAPACITY 360
EXIT WIDTH 72"
S
S
S
S
0 4 8 16 32
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
RK
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
4
7
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
_
1
0
d
e
m
o
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
CONTRACTOR TO PROVIDE PROTECTION TO ALL SURFACES THAT ARE TO REMAIN.
COORDINATE TRASH REMOVAL AND DUMPSTER LOCATION WITH BUILDING MANAGER.
CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL TRASH FROM SITE.
EXISTING CONSTRUCTION TO REMAIN
EXISTING DOOR TO REMAIN
EXISTING GLASS PARTITION TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
EXISTING MILLWORK TO BE REMOVED
EXISTING DOOR TO BE REMOVED/REUSED
EXISTING GLASS PARTITION TO BE REMOVED/REUSED
WHENEVER POSSIBLE.
CONTRACTOR TO SALVAGE ALL EXISTING CEILING TILE AND GRID FOR RE-USE
SOURCE OF ORIGIN.
DEMOLITION OF ALL UNUSED HVAC AND PLUMBING SHOULD GO BACK TO THE
ONTO EXISTING FLOORING.
ENTRANCE DOORS TO DEMOLITION AREA TO PREVENT TRACKING OF DIRT/DEBRIS
CONTRACTOR SHALL PROVIDE WALK-OFF CARPET MATS (48'X48") AT ALL
ADJUSTMENT DEVICES FOR REPLACEMENT.
PROTECT FROM DUST OR DAMAGE; DOCUMENT MISSING PULL STRINGS AND
PULL WINDOW COVERINGS TO TOP OF WINDOW AND WRAP IN PLASTIC TO
PARTITION LAYOUT.
ARE TO BE DETERMINED BY THE HVAC CONTRACTOR AS REQUIRED FOR NEW
RELOCATION AND/OR REMOVAL OF DUCTWORK, TERMINAL BOXES, AND AIR DEVICES
EXISTING DUCTWORK TO REMAIN DURING DEMOLITION UNLESS NOTED OTHERWISE.
AND/OR COMMON AREAS.
DEMOLITION FROM ENTERING ADJACENT LEASE SPACE AND THE OTHER FLOORS
CONTRACTOR SHALL TAKE REQUIRED MEASURES TO KEEP DUST CAUSED BY SHOW LIMITS AND EXTENT OF DEMOLITION WORK ONLY.
OF ALL WORK TO BE DEMOLISHED. DEMOLITION DRAWINGS ARE INTENDED TO
CONTRACTOR TO FIELD VERIFY THE EXACT QUANTITY, SIZE AND LOCATIONS
ON THE DRAWINGS.
MECHANICAL OR ELECTRICAL SYSTEMS UNLESS SPECIFICALLY CALLED OUT
NO DEMOLITION SHALL OCCUR AT ANY BASE BUILDING WALLS, PLUMBING,
FURRING CAUSED BY DEMOLITION.
MATCHING CONSTRUCTION TO CLOSE ANY OPENINGS IN THE EXISTING COLUMN
SHOULD BE REMOVED DOWN TO THE LIMITS OF THE COLUMN WRAP. PROVIDE
ON THE PLANS. ALL DEMOLITION TO WALLS COMMON WITH COLUMN FURRING
COLUMN FURRINGS ARE NOT TO BE DEMOLISHED UNLESS NOTED SPECIFICALLY
UNLESS SPECIFICALLY CALLED OUT.
NO DEMOLITION IS TO TAKE PLACE OUTSIDE THE LIMITS OF THESE DRAWINGS
AFFECTED BY DEMOLITION INCLUDED IN THIS SCOPE OF WORK.
EXISTING WALLS, FLOORS, CEILINGS AND UTILITIES THAT ARE TO REMAIN AND
NECESSARY AND REQUIRED FOR THE PROPER SUPPORT AND SAFETY OF ALL
THE CONTRACTOR SHALL FURNISH ALL SHORING, BRACING, AND PATCHING
PROJECT DEMOLITION NOTES FOR ADDITIONAL SALVAGE ITEMS.
DISPOSITION OF BALANCE OF DOORS/FRAMES WITH LANDLORD. REFER TO
REUSED IN MEETING REQUIREMENTS OF THE DOOR SCHEDULE. VERIFY
SCHEDULE. VERIFY QUANTITY AND DOOR SWINGS OF EXISTING DOORS TO BE
SALVAGE DOORS AND FRAMES FOR RE-USE AS INDICATED ON DOOR
BY THE CONTRACTOR AT NO COST TO THE TENANT OR LANDLORD.
CAUSED BY THE DEMOLITION PROCESS WILL BE REPAIRED AND/OR REPLACED
ANY DAMAGE TO REMAINING CONSTRUCTION AND/OR BASE BUILDING ITEMS
WITH BUILDING MANAGEMENT.
TO BUILDING STOCK. COORDINATE ALL SALVAGE AND STORAGE OF THESE ITEMS
FRAMES,HARDWARE, MILLWORK, AND OTHER RE-USABLE ITEMS ARE TO BE RETURNED
ALL SALVAGEABLE MATERIALS SCHEDULED TO BE DEMOLISHED, SUCH AS DOORS,
ALL REMOVED CORE DRILLS.
CAP/SEAL ANY UNUSED PLUMBING AND PROVIDE FLOOR FILL AND FIRE SEAL AT
SPECIFIED ON FINISH PLAN.
FASTENERS, REVEALS, NAILS, ETC. AT AREAS TO RECEIVE NEW FINISHES AS
REMOVE EXISTING WALL COVERING, FLOORING AND BASE AS WELL AS WALL
DEMOLISH WALLS, DOOR FRAMES, MILLWORK AND SOFFITS AS INDICATED ON PLAN.
DEMOLITION PLAN
PLAN
DEMOLITION
A1.10
KEYED NOTESDEMOLITION GENERAL NOTESDEMOLITION SYMBOLS
1.
2.
3.
4.
5.
8.
10.
6.
7.
9.
11.
12.
13.
14.
15.
16.
18.
19.
17.
20.
01
02
03
04
05
06
TYPICAL THROUGHOUT LIMIT OF WORK.
REPAIR FLOOR TO CREATE A LEVEL SURFACE FOR NEW FLOOR FINISH.
CONTRACTOR TO REMOVE EXISTING FLOOR AND BASE FINISHES. PATCH AND
07
08
09
TAKE ANY RESIDUAL WIRING BACK TO SOURCE.
EXISTING POWER/BLANK PLATES TO BE REMOVED.
TAKE ANY RESIDUAL WIRING BACK TO SOURCE.
EXISTING DATA TO BE REMOVED.
OTHERWISE, COORDINATE WITH LANDLORD.
BUILDING STOCK. TYPICAL THROUGHOUT LIMIT OF WORK UNLESS NOTED
CONTRACTOR TO SALVAGE ALL BUILDING STANDARD DOORS AND RETURN TO
BUILDING STOCK. COORDINATE WITH LANDLORD
AND SALVAGE FOR REUSE AS INDICATED ON A1.40. RETURN UNUSED TO
CONTRACTOR TO REMOVE EXISTING LIGHT FIXTURES THROUGHOUT SPACE
LAYOUT PRIOR TO DEMOLITION.
REFER TO A1.21 FOR EXTENT OF DEMOLITION. REFER TO NEW PARTITION
BE IN TENANT SPACE UNLESS SPECIFIED OTHERWISE.
COORDINATE FINAL REMOVAL LOCATIONS WITH A1.30. NO BLANK PLATES TO
PATCH AND REPAIR WALL AS REQUIRED FOR "LIKE-NEW" APPEARANCE.
JUNCTION BOXES, DEVICES AND ASSOCIATED WIRING BACK TO SOURCE.
CONTRACTOR TO REMOVE ALL UNUSED POWER, DATA, BLANK PLATES,
21.
BY THE GENERAL CONTRACTOR AT CONTRACTOR'S EXPENSE.
ANY ITEMS NOT WANTED BY BUILDING MANAGEMENT ARE TO BE DISPOSED OF
POKE-THRU'S AS REQUIRED.
CAP/FILL AND PROVIDE FIRE SEAL FOR CORE DRILLS AT FLOOR
& RCP FOR LOCATIONS. PREPARE WALLS TO RECEIVE NEW FINISHES.
AND SWITCHES ARE TO BE REMOVED. REFER POWER/COMMUNICATIONS PLAN
OF PLENUM SPACE. PATCH/REPAIR WALLS AT LOCATIONS WHERE OUTLETS
HAVE CABLING/CONDUIT/BOXES TAKEN BACK TO ORIGINAL PANELS AND OUT
ELECTRICAL AND DATA/COMMUNICATIONS OUTLETS TO BE REMOVED ARE TO EXISTING FINISHES/SURFACES TO REMAIN.
EXISTING WALLS, CORNERS, AND DOOR/JAMBS TO PREVENT DAMAGE TO ALL
CONTRACTOR SHALL PROVIDE PROTECTIVE MATERIAL TEMPORARILY SECURED TO COST TO MARCUS & MILLICHAP.
COORDINATE FINISHES IN MULTI-TENANT CORRIDOR WITH LANDLORD AT NO
FOR NEW PARTITION LAYOUT. PRIOR TO DEMOLITION CONTRACTOR TO
TENANT EGRESS. COORDINATE DEMOLITION WITH LANDLORD. REFER TO A1.20
CONTRACTOR TO REMOVE SECTION OF BUILDING CORRIDOR WALL FOR NEW
MARCUS &
MILLICHAP
MARCUS &
MILLICHAP
FUTURE
TENANT
01
0101
01 01
01
01 01
01010101
01
01
02 03 04
05
07
08
09 09
TYPICAL THOUGHOUT LIMIT OF WORK
01
ARE EXISTING TO REMAIN.
MILLICHAP SIDE TO RECEIVE NO WORK AND ALL CONSTRUCTION/FINISHES
LINE INDICATES LOCATION OF NEW DEMISING WALL. NON MARCUS &
05 05 05
05
05
REPLACE STAINED/DAMAGED TILES THROUGHOUT SUITE.
CEILING TILE FOR REUSE UNLESS NOTED OTHERWISE ON SHEET A1.40.
CONTRACTOR TO REMOVE EXISTING CEILING GRID AND SALVAGE EXISTING
10
WALLS AS REQUIRED.
CONTRACTOR TO REMOVE EXISTING FURNITURE OVERHEADS, PATCH & REPAIR
11
12
EXISTING PLUMBING AND CAP BACK TO SOURCE.
CONTRACTOR TO REMOVE EXISTING MILLWORK, SINK AND APPLIANCES, REMOVE
OTHER EQUIPMENT TO BRING SPACE TO "VANILLA BOX"
CONTRACTOR TO REMOVE EXISTING SERVER EQUIPMENT, PLYWOOD AND ANY
NOT USED.
10
11 11
11
12
11
EXISTING
TENANT
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
4
8
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
_
2
0
c
o
n
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
10 floor 5
" = 1'-0"8
1
NORTH
PLAN
OFFICEOFFICEOFFICERM OFFICE
OFFICE OFFICE OFFICEBREAK/COPY STORAGE
OFFICE
SERVER RECEPTION
COAT
CONFERENCE
SMALL
OFFICEOFFICE
CONFERENCE
LARGE
514 515 516 517 518
501 500
513 512 511 510 509 508 507 503
502
505 504
STOR.
FEC
500
502
501
504505
506
503
518517516
507508509510511512513
514
515
519
OFFICE
OPEN
506
OFFICE
OPEN
519
FEC
0 4 8 16 32
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
RK
CONSTRUCTION PLAN
PLAN
CONSTRUCTION
KEYED NOTES
A1.20
1.
2.
3.
4.
5.
6.
7.
8.
10.
11.
12.
15.
14.
16.
17.
18.
19.
20.
DOOR OPENINGS, ETC.
CONTRACTOR IS RESPONSIBLE FOR FIELD DIMENSIONS OF ALL MILLWORK, GLASS,
9.
NEW FLOOR TO CEILING PARTITIONEXISTING PARTITION TO REMAIN
DOOR TYPE/FRAME/HARDWARE SYMBOL
PARTITION SYMBOLS XX
5'-0"DIMENSIONS / LEADERS
LIMIT OF WORK LINE
LIMIT OF WORK
NOTE
DETAIL SYMBOL
DETAIL NUMBER
SHEET NUMBER
EXISTING PARTITION TO BE REMOVED
ROOM NAME SYMBOL
ELEVATION SYMBOL
DETAIL NUMBER DETAIL NUMBER
SECTION SYMBOL
KEYNOTE SYMBOL
SHEET NUMBER
100
ROOM NAME
00/A0.00 00/A0.00
SHEET NUMBER
00
ROOM NUMBER
EQUIPMENT SYMBOL
00-0
ARCHITECTURAL SYMBOLS
(DOORS WITHOUT A SYMBOL ARE EXISTING TO REMAIN)
NEW FLOOR TO DECK PARTITION
00/A0.00 00/A0.00
IN THE SAME PLANE SHALL BE FLUSH WITH NO VISIBLE JOINTS SHOWING.
NEW DRYWALL CONSTRUCTION MEETING EXISTING DRYWALL CONSTRUCTION
STUD PARTITIONS. ALL WOOD/BLOCKING SHALL BE FIRE-TREATED AS REQUIRED.
PROVIDE ADDITIONAL BRACING, ANCHORING, AND/ OR DELETE SPACE BLOCKING IN
WHERE IT IS DEEMED NECESSARY TO ENSURE STABILITY, CONTRACTOR SHALL
WOODWORK INSTITUTE CUSTOM STANDARDS, UNLESS NOTED OTHERWISE.
ALL MILLWORK/WOODWORK IS TO FABRICATED IN ACCORDANCE WITH ARCHITECTURAL
TELEPHONE OR PLUMBING OCCUR ( AS REQUIRED). REFER TO PLANS FOR LOCATIONS.
FURR-OUT CORE WALLS AND COLUMNS AT ALL LOCATIONS WHERE ELECTRICAL,
21.
LOCATIONS WHERE PARTITIONS ADJOIN EXTERIOR WALL
CONTRACTOR TO ENSURE CLEAR ACCESS TO MECHANICAL EQUIPMENT AT
22.
VISUAL & AUDIBLE DEVICES COMPLY WITH APPLICABLE LOCAL CODES.
THE CONTRACTOR SHALL HAVE THE FIRE PROTECTION ENGINEER VERIFY THAT
23.
24.
CONDITION, WORKING ORDER AND STRUCTURAL INTEGRITY.
CONTRACTOR TO REVIEW ANY ITEMS INTENDED FOR RELOCATION/REUSE FOR
FIXTURES AND ABOVE CEILING CONDITIONS. REFER REFLECTED CEILING PLAN.
PROVIDE/RELOCATE FIRE SPRINKLER HEADS AS REQUIRED. COORDINATE WITH LIGHTING
25.
26.
000
MATERIALS, ADHESIVES, OR PRODUCTS CONTAINING ASBESTOS.
UNDER NO CIRCUMSTANCES IS THE CONTRACTOR TO FURNISH OR INSTALL ANY
SPECIFICATIONS. COORDINATE FINISH WITH SHEET A0.001 UNLESS NOTED OTHERWISE.
SHEETS/DETAILS AND LOCATIONS FOR APPROVAL IN ACCORDANCE WITH ARCHITECTS
MOUNTING HEIGHT SCHEDULE SHEET A0.01 . CONTRACTOR TO PROVIDE CUT
WITH FIRE MARSHALL. FIRE EXTINGUISHER TO BE MOUNTED AS INDICATED ON
PROVIDE NEW FIRE EXTINGUISHERS IN CABINETS (FE) PER CODE. VERIFY LOCATIONS
STORAGE OF THESE ITEMS WITH BUILDING MANAGEMENT.
TO BUILDING STOCK, UNLESS NOTED OTHERWISE. COORDINATE ALL SALVAGE AND
FRAMES, HARDWARE, MILLWORK, AND OTHER RE-USABLE ITEMS ARE TO BE RETURNED
ALL SALVAGEABLE MATERIALS SCHEDULED TO BE DEMOLISHED, SUCH AS DOORS,
ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
ERRORS, OR OTHER SIMILAR CONDITIONS, ARE TO BE IMMEDIATELY BROUGHT TO THE
ANY CONFLICTS IN DIMENSIONS DUE TO FIELD CONDITIONS, TYPOGRAPHICAL
STANDARDS.
TO MATCH THE CONSTRUCTION TYPE, MEETING THE REQUIREMENTS OF BUILDING
WITH SOUND INSULATION IN ENTIRE WALL CAVITY. ALL NEW DEMISING WALLS ARE
LEASE SPACE PRIOR TO BID. ENSURE ALL DEMISING WALLS ARE EXTENDED TO DECK
VERIFY CONSTRUCTION TYPE OF ALL EXISTING DEMISING WALLS AT PERIMETER OF
AT GC KICKOFF CONFERENCE CALL.
FROM THE BEGINNING OF CONSTRUCTION. LONG-LEAD TIME ITEMS TO BE IDENTIFIED
THE CONTRACTOR TO TRACK LONG-LEAD TIME ITEMS (AS NOTED ON A0.00) WEEKLY
EXTERNAL WINDOW SYSTEM WITH SCREWS, AND OR MECHANICAL FASTENERS, ETC.
STRIP/ SOUND SEAL AT THESE LOCATIONS. DO NOT PENETRATE CURTAIN WALL OR
BE ALIGN WITH CENTERLINE OF WALL UNLESS NOTED OTHERWISE. PROVIDE CLOSURE
AT LOCATIONS WHERE PARTITIONS ADJOIN MULLIONS, CENTERLINE OF PARTITION IS TO
PRIOR TO INSTALLATION. ALL PENETRATIONS TO BE SEALED PER APPLICABLE CODE.
VERIFY FLOOR PENETRATIONS WITH ARCHITECT, STRUCTURAL ENGINEER & LANDLORD
ALL WALL ANGLES ARE 90 DEGREES OR 45 DEGREES UNLESS NOTED OTHERWISE.
13.
ARCHITECT.
CONTRACTOR SHALL NOT BEGIN FRAMING WITHOUT APPROVAL OF WALL LAYOUT BY
ANY DISCREPANCIES IN THE DRYWALL LAYOUT FROM THE CONSTRUCTION PLAN.
OF PARTITION CONSTRUCTION. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF
CONTRACTOR IS TO CHALK WALL LAYOUT ON CONCRETE FLOOR PRIOR TO BEGINNING
WINDOWS WHERE MISSING TO MATCH ADJACENT EXISTING TYPE, STYLE & COLOR.
PROVIDE AND INSTALL NEW BUILDING STANDARD WINDOW COVERINGS AT ALL EXTERIOR
COMPONENTS ARE IN PLACE AND CONSISTENT IN APPEARANCE AND OPERATION. G.C. IS TO
EXTERIOR WINDOWS, REPAIR CORDS, WANDS, SLATS IN BLINDS, ETC. TO INSURE THAT ALL
REPAIRS OR SUPPLEMENTAL PARTS TO ALL EXISTING WINDOW TREATMENTS AT ALL
G.C. SHALL PERFORM FIELD SURVEY OF EXISTING WINDOW TREATMENTS AND PROVIDE
SOUND TRANSMISSION.
TO EXTERIOR GLASS TERMINATION POINTS. PROVIDE INSULATION AS REQUIRED FOR
PROVIDE WALL END CAP DETAILS TO MATCH BUILDING STANDARD AT ALL DRYWALL
CONSTRUCTION GENERAL NOTES
PATCH EXISTING FIRE-PROOFING WHERE DISTURBED BY NEW CONSTRUCTION.
ON PLAN. CONTRACTOR TO REFER TO 16/A6.10 FOR DETAILS.
CONTRACTOR TO PROVIDE AND INSTALL COAT ROD AND SHELF WHERE INDICATED
01
02
03
04
05
06
07
08
12
09
10
11
BED ONLY. NO PAINT.
VACANT SIDE OF DEMISING WALL TO RECEIVE GYP BOARD WITH TAPE AND
SPECIFICATION.
B-1/A0.02 UNDER APPLIANCE/PRODUCT SPECIFICATION FOR BRACKET
ARE SECURED TO BRACKETS. REFER TO 15/A6.10 FOR SHELVING DETAILS AND
IN WALL TO BOLT STANDARDS AS REQUIRED. CONTRACTOR TO ENSURE SHELVES
SHELVES. STANDARDS SPACED EQUALLY AT 24" O.C. MAX. PROVIDE BLOCKING
BOTTOM SHELF AT 24" A.F.F. & ALLOW CLEAR DISTANCE OF 15" BETWEEN
SHELVES ON KV BRACKETS & STANDARDS WHERE INDICATED ON PLAN. MOUNT
PROVIDE AND SECURE (5) 16" D PLASTIC LAMINATE CLAD (PL-1) ADJUSTABLE
SMOOTH AND PAINT PLYWOOD AS SCHEDULED. REFER 12/A1.32.
IN SERVER ROOM. MOUNT PLYWOOD AS CLOSE TO CEILING AS POSSIBLE.
MOUNTED VERTICALLY FOR TENANT'S TELEPHONE EQUIPMENT ON ALL WALLS
PROVIDE 8' (H) X ƒ" A.C. GRADE NON COMBUSTABLE PLYWOOD BACKBOARD
WORK. COORDINATE WITH LANDLORD AS REQUIRED.
BLINDS AND REINSTALL/REPLACE AS REQUIRED. TYPICAL THOUGHOUT LIMIT OF
CONTRACTOR TO VERIFY WORKING CONDITION OF ALL BUILDING STANDARD
CABINETS AS INDICATED ON A0.02 (FEC-1)
CONTRACTOR TO PROVIDE AND INSTALL SEMI-RECESSED FIRE EXTINGUISHER
AND DOOR HARDWARE
DOOR TYPE - REFER A6.11 FOR DOOR SCHEDULE
REFER TO SECTIONS SHEET A6.10
PARTITION TYPE INDICATOR
PARTITION SCHEDULE AND CONSTRUCTION PLAN FOR WALL TYPE LOCATIONS.
ALL PARTITIONS TO BE TYPE "P2" UNLESS NOTED OTHERWISE. REFER TO
LOCAL ACCESSABILITY STANDARDS.
ALL DOORS SHALL HAVE MANEUVERING CLEARANCES AS REQUIRED BY ADA AND
FIXTURES UNLESS EXISTING PLUMBING IS WITHIN 24" OF NEW SINK OR FIXTURE.
CONTRACTOR MAY NOT RE-USE EXISTING ROUGH PLUMBING AT NEW SINKS AND
WALL. REFER 03/A2.10 FOR EXACT LOCATION
INDICATED ON PLAN BLOCKING AND VISUAL AID BOARD TO BE CENTERED ON
DIRECTLY TO BLOCKING AND FINISHED AS SPECIFIED ON SHEET A1.50. WHERE
OF PLYWOOD TO BE MOUNTED AT 2'-10" AFF. DRYWALL TO BE APPLIED
HORIZONTALLY IN PARTITION FOR TENANT PROVIDED VISUAL AID BOARD. BOTTOM
CONTRACTOR TO PROVIDE 4' X 8' X ƒ" PLYWOOD BLOCKING MOUNTED
FOR LOCATIONS.
EXISTING PARTITIONS; BLOWN IN INSULATION WILL NOT BE ACCEPTED. REFER TO A1.20
PARTITION TYPE 'P2'. CONTRACTOR TO UTILIZE BATT ROLLS ONLY TO RETROFIT
CONTRACTOR IS RESPONSIBLE FOR RETROFITTING EXISTING PARTITION TO MEET
'P2'/SHEET A6.10. IF EXISTING PARTITIONS DO NOT MATCH PARTITION TYPE 'P2' THEN
CONTRACTOR TO VERIFY ALL EXISTING OFFICE PARTITIONS MATCH PARTITION TYPE
INSULATION WHERE REQUIRED BY CODE.
ROOM WALLS. (TYPICAL U.N.O.) CONTRACTOR TO PROVIDE FULLY ENAPSULATED
TILES, EXTENDING 3' ON EACH SIDE OF ALL PRIVATE OFFICES AND CONFERENCE
CONTRACTOR TO INSTALL PLENUM-RATED CEILING INSULATION ON TOP OF CEILING
AT NO COST TO MARCUS & MILLICHAP. COORDINATE FINISHES WITH LANDLORD.
CONTRACTOR TO MATCH ADJACENT CORRIDOR PARTITION CONSTRUCTION/RATING
CH-1 ON SHEET A0.02 FOR SPECIFICATION.
BACK (OFFICE SIDE) OF DOOR CENTERED HORIZONTALLY AT 72" AFF. REFER TO
PROVIDE COAT HOOK IN EACH PRIVATE OFFICE. COAT HOOKS TO BE MOUNTED ON
POWER/DATA.
REQUIREMENTS. CONTRACTOR TO PROVIDE CUT OUT IN BLOCKING FOR
BE PROVIDED BY MARCUS & MILLICHAP. REFER TO 13/A1.32 FOR ADDITIONAL
TENANT PROVIDED PLASMA SCREEN. PLASMA SCREEN AND MOUNTING BRACKET TO
CONTRACTOR TO PROVIDE 4' X 4' ƒ" BLOCKING CENTERED AT 66" AFF, FOR
FULLY ENAPSULATED INSULATION WHERE REQUIRED BY CODE.
TOP OF CEILING TILES, EXTENDING 3' ON EACH SIDE. CONTRACTOR TO PROVIDE
EXISTING DRYWALL AS REQUIRED. INSTALL PLENUM-RATED CEILING INSULATION ON
INSIDE EXISTING PARTITION TO MATCH WALL TYPE 'P2' ON SHEET A6.10. PATCH
THE EXISTING WALLS. CONTRACTOR IS TO INSTALL NEW ROLL BATT INSULATION
CONTRACTOR TO VERIFY IF SOUND INSULATION EXISTS INSIDE THE CAVITY OF
P2 P2
P2
P2 P2
P
2
P
2
P
2
01
02
02
03
04 04 04 04 04 04 04
04 04 04
06 06 07
06
06
06
06 06 06
07
07 07 07 0707
0606060606
08
09
10
11
12
OF WORK
THOUGHOUT LIMIT
TYPICAL
P
6
12
ALT#3
ALT#5 ALT#6
ALT#7
ALT#8
0
1/
A
4
.
10
03/A4.100
4
/
A
4
.
10 07/A4.10
07 07 07
07
P3
P2
P
2
P2
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
5
0
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
_
2
1
d
im
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
10 floor 5
" = 1'-0"8
1
NORTH
PLAN
OFFICEOFFICEOFFICERM OFFICE
OFFICE OFFICE OFFICEBREAK/COPY STORAGE
OFFICE
SERVER RECEPTION
COAT
CONFERENCE
SMALL
OFFICEOFFICE
CONFERENCE
LARGE
514 515 516 517 518
501 500
513 512 511 510 509 508 507 503
502
505 504
STOR.
FEC
OFFICE
OPEN
506
OFFICE
OPEN
519
FEC
0 4 8 16 32
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
RK
OFFICE
512
KEYED NOTES
1.
2.
3.
4.
5.
6.
DOOR OPENINGS, ETC.
CONTRACTOR IS RESPONSIBLE FOR FIELD DIMENSIONS OF ALL MILLWORK, GLASS,
APPROVAL OF WALL LAYOUT BY ARCHITECT.
CONSTRUCTION PLAN. CONTRACTOR SHALL NOT BEGIN FRAMING WITHOUT
IMMEDIATELY OF ANY DISCREPANCIES IN THE DRYWALL LAYOUT FROM THE
BEGINNING OF PARTITION CONSTRUCTION. CONTRACTOR SHALL NOTIFY ARCHITECT
CONTRACTOR IS TO CHALK WALL LAYOUT ON CONCRETE FLOOR PRIOR TO
MECHANICAL FASTENERS, ETC.
CURTAIN WALL OR EXTERNAL WINDOW SYSTEM WITH SCREWS, AND OR
CLOSURE STRIP/ SOUND SEAL AT THESE LOCATIONS. DO NOT PENETRATE
TO BE ALIGN WITH CENTERLINE OF WALL UNLESS NOTED OTHERWISE. PROVIDE
AT LOCATIONS WHERE PARTITIONS ADJOIN MULLIONS, CENTERLINE OF PARTITION IS
IN THE SAME PLANE SHALL BE FLUSH WITH NO VISIBLE JOINTS SHOWING.
NEW DRYWALL CONSTRUCTION MEETING EXISTING DRYWALL CONSTRUCTION
THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
ERRORS, OR OTHER SIMILAR CONDITIONS, ARE TO BE IMMEDIATELY BROUGHT TO
ANY CONFLICTS IN DIMENSIONS DUE TO FIELD CONDITIONS, TYPOGRAPHICAL
TELEPHONE OR PLUMBING OCCUR ( AS REQUIRED). REFER TO PLANS FOR LOCATIONS.
FURR-OUT CORE WALLS AND COLUMNS AT ALL LOCATIONS WHERE ELECTRICAL,
OTHERWISE.
ALL WALL ANGLES ARE EITHER 90 DEGREES OR 45 DEGREES UNLESS NOTED
DIMENSION PLAN
A1.21
DIMENSION PLAN
7.
8.
DIMENSION GENERAL NOTES
02
TO 14/A6.10 FOR PARTITION AND MULLION CONNECTION.
ALIGN CENTERLINE OF PARTITION WITH CENTERLINE OF MULLION/COLUMN. REFER
03
01
LOCAL ACCESSABILITY CODES.
ALL DOORS SHALL HAVE MANEUVERING CLEARANCES AS REQUIRED BY ADA AND
BETWEEN DIMENSIONS SHOWN AND FIELD CONDITIONS
CONTRACTOR TO NOTIFY STAFFELBACH IMMEDIATELY OF ANY DISCREPANCIES
01 " = 1'-0"4
1
SIZE). REFER TO A6.11 FOR FRAME ELEVATIONS. FIELD VERIFY.
DIMENSION OF SIDELIGHT INDICATES INTERIOR OF FRAME ONLY (VISIBLE GLASS
10
'
-
6
"
12
'
-
3
ƒ
"
2
'
-
3
ƒ
"
5
'
-
10
"
4
'
-
4
"
5
‚
"
12'-4•"12'-3ƒ"4'-9ƒ"6'-9ƒ"5'-3ƒ"19'-8ƒ"
01
02 02
03
WORK
LIMIT OF
THOUGHOUT
TYPICAL
9'-4ƒ"5'-9ƒ"5'-9ƒ"5'-11‚"10'-11‚"5'-11‚"6'-0"5'-11‚"
7'-6ƒ"7'-8‚"9'-0"
5
'
-
10
ƒ
"
1'
-
9
"
PANELS
2 GLASS
PANELS
2 GLASS
PANELS
2 GLASS
PANELS
2 GLASS
PANELS
2 GLASS
PANELS
2 GLASS
PANELS
4 GLASS
PANELS
3 GLASS
P
A
N
E
L
)
(
1
G
L
A
S
S
PANELS
3 GLASS
P
A
N
E
L
S
2
G
L
A
S
S
HOLD
2'-2•"
13'-7•"
8
"
1'-6"
1'-6"
HOLD
10'-4‚"
16
'
-
3
•
"
8'-0"
PANELS
3 GLASS
PANELS
3 GLASS
6'-0"
12
'
-
0
"
2 GLASS PANELS
AT PRIVATE OFFICE #512
ENLARGED DIMENSION PLAN
01/A1.21
6'-9"
7
'
-
6
•
"
FEC FEC
OM
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
5
1
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
_
3
0
e
le
c
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
10 floor 5
" = 1'-0"8
1
NORTH
PLAN
OFFICEOFFICEOFFICERM OFFICE
OFFICE OFFICE OFFICEBREAK/COPY STORAGE
OFFICE
+48
+17
SERVER RECEPTION
COAT
CONFERENCE
SMALL
OFFICEOFFICE
CONFERENCE
LARGE
PD
P
D
+44+44+44
+44 +44 +44
+44
+17
+17+17
S
CR
C
R
T
V
+66
+36
5-20 R
NEMA
5-20 R
NEMA
+17
C
R
J
514 515 516 517 518
501 500
513 512 511 510 509 508 507 503
502
505 504
STOR.
OFFICE
OPEN
506
OFFICE
OPEN
519
E EEEEEEE
E
E
E
E
E
E
E
E E
E
E
E
+48
WH
0 4 8 16 32
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
RK
PLAN
POWER/COMMUNICATIONS
POWER/COMMUNICATIONS PLAN
A1.30
POWER & COMMUNICATIONS GENERAL NOTES
ALL OUTLETS LOCATED WITHIN 6'-0" OF PLUMBING SHALL BE G.F.I. OUTLETS.
01.
02.
03.
04.
05.
06.
07.
08.
09.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
KEYED NOTES
CR
J
P
D
MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED DUPLEX ELECTRICAL OUTLET, 120 VOLT (SUBSCRIPT INDICATES
(SUBSCRIPT INDICATES MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED DUPLEX ELECTRICAL OUTLET ON SEPARATE CIRCUIT
INDICATES MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED QUADRAPLEX ELECTRICAL OUTLET, 120 VOLT (SUBSCRIPT
(SUBSCRIPT INDICATES MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED QUADRAPLEX ELECTRICAL OUTLET ON SEPARATE CIRCUIT
SYMBOLS LEGEND
NEMA L5-30R DEDICATED RECEPTACLE - TWIST LOCK
FIRE-DROP RELAY.
PROVIDE FIRE RATED J-BOX CEILING TIE-IN TO BUILDING FIRE PANEL. ELECTRICIAN TO PROVIDE
THROUGHOUT LIMIT OF WORK.
CONTRACTOR TO PROVIDE AND INSTALL CONDUIT, RING AND STRING FOR ALL DATA OUTLETS, TYPICAL
PANELS.
ARE TO BE REMOVED INCLUDING ALL CONDUIT AND WIRING BACK TO THEIR RESPECTIVE ELECTRICAL
ALL EXISTING ELECTRICAL OUTLETS LOCATED ON PARTITIONS TO BE DEMOLISHED ARE NOT SHOWN AND
EACH ELECTRICAL CIRCUIT SHALL NOT EXCEED SIX (6) GENERAL USE ELECTRICAL OUTLETS.
ALL NEW WALL OUTLETS ARE TO BE MOUNTED AT 17" A.F.F TO CENTERLINE, UNLESS NOTED OTHERWISE.
AND CODES/ORDINANCES.
ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF THE MANUFACTURER
AND LIGHT SWITCH LOCATIONS WITH FURNITURE AND EQUIPMENT SHOWN ON ARCHITECTS POWER PLAN.
EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY FROM PLAN. COORDINATE ELECTRICAL/DATA
CONTRACTOR TO FIELD COORDINATE LOCATIONS OF ALL NEW POWER AND COMMUNICATIONS OUTLETS WITH
PENETRATIONS. INSTALL FIRE PROOFING AT ALL PENETRATIONS PER LOCAL CODES AND ORDINANCES.
REQUIRED BY ENGINEER INCLUDING, BUT NOT LIMITED TO SLAB X-RAY, PRIOR TO CONDUCTING ANY SLAB
VERIFY TYPE OF FLOOR SLAB WITH BUILDING'S STRUCTURAL ENGINEER. PROVIDE ALL SAFEGUARDS AS
OUTLETS ARE TO BE LABELED ORANGE AS DEDICATED.
UNLESS NOTED OTHERWISE IN ENGINEERED DRAWINGS (IF PROVIDED), ALL "DEDICATED CIRCUIT" ELECTRICAL
AS REQUIRED FOR COMPLIANCE WITH APPLICABLE UL LISTING, (WHICHEVER MAY BE THE MOST RESTRICTIVE).
(2'-0") FEET O.C. AND NOT MORE THAN ONE (1) HOLE PER 65 SQUARE FEET OF AREA OF FLOOR SPAN OR
"POKE-THRU" ELECTRICAL DEVICES, WHEN PLACED IN MULTIPLES, MUST HAVE A MINIMUM SEPARATION OF TWO
LOCATION ONLY. REFER TO ELECTRICAL ENGINEERING DOCUMENTS FOR CODE COMPLIANCE.
THIS DRAWING HAS BEEN PREPARED TO ASSIST THE OWNER. ARCHITECT'S POWER PLAN INDICATES
SHOWN OR IMPLIED ON ALL PLANS.
CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL DEVICES AND PERFORM ALL ELECTRICAL WORK AS
JURISDICTION.
BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES AND TELEPHONE COMPANIES, AND OTHER AUTHORITIES HAVING
ALL WORK IS TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER, NATIONAL
INSTALLATION INDICATED.
LABORATORIES INC. IN EVERY CASE WHERE SUCH A STANDARD HAS BEEN ESTABLISHED FOR THE
ALL MATERIALS REQUIRED SHALL CONFORM WITH THE STANDARDS SET BY THE UNDERWRITERS
TELEPHONE/COMMUNICATION CABLING AS REQUIRED.
TENANT'S CABLING VENDOR TO REWORK ANY EXISTING OUTLETS AND SUPPLY AND INSTALL
CONTRACTOR TO PROVIDE AND INSTALL ALL LOW VOLTAGE CONDUIT AS REQUIRED BY CODE.
PROVIDE FIRE SEAL FOR CORE DRILL & MONUMENT OUTLETS AS REQUIRED.
BACK TO ORIGINAL PANEL. PATCH/REPAIR WALL AND PREPARE FOR SCHEDULED FINISH. CAP/FILL AND
ELECTRICAL OUTLETS TO BE REMOVED ARE TO HAVE CABLING/CONDUIT TAKEN OUT OF PLENUM AND
MEP DRAWINGS AND REPORT ANY DISCREPANCIES IMMEDIATELY TO STAFFELBACH.
CONTRACTOR IS TO COMPARE ARCHITECTURAL POWER/COMMUNICATIONS PLAN WITH ASSOCIATED
RELAY, TENANT VENDOR TO TIE CARD READER TIE CARD READER INTO FIRE-DROP RELAY.
@ 48" AFF ELECTRICIAN TO PROVIDE TIE-IN FOR CARD READER ACCESS TO BUILDING FIRE-DROP
CARD READER BY TENANT VENDOR- CONTRACTOR TO PROVIDE CONDUIT, RING AND STRING - MOUNT
PROVIDE CONDUIT, RING AND STRING -- COORDINATE WITH COMMUNICATIONS VENDOR.
INDICATES MOUNTING HEIGHT AFF - 14" UNLESS HEIGHT DIMENSION IS INDICATED) - CONTRACTOR TO
WALL-MOUNTED JUNCTION BOX FOR DATA/COMMUNICATIONS TO SYSTEMS FURNITURE (SUBSCRIPT
INDICATES MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
CABLE WITH ORANGE JACKS, CONTRACTOR TO PROVIDE CONDUIT RING AND STRING (SUBSCRIPT
WALL-MOUNTED DATA OUTLET, DUAL PRIMARY NETWORK LOCATION (2 DATA JACKS) BLUE CAT 5E
CEILING MOUNTED J-BOX POWER OUTLET
01
02
03
04
07
08
09
10 FURNITURE VENDOR.
POWER AND DATA FOR PRINT STATION IS TO BE FURNITURE PANEL BASED, OUTLETS PROVIDED BY
11 CONTRACTOR IS REQUIRED TO CONNECT FURNITURE WHIPS TO BUILDING POWER
12
13
AFF - 17" UNLESS HEIGHT IS INDICATED)
CONTRACTOR TO PROVIDE CONDUIT RING AND STRING (SUBSCRIPT INDICATES MOUNTING HEIGHT
WALL-MOUNTED DATA OUTLET, PRIMARY NETWORK CABLE BLUE CAT 5E CABLE WITH ORANGE JACK,
WALL-MOUNTED PHONE AT 48" AFF CONTRACTOR TO PROVIDE CONDUIT RING AND STRING
WH
FLUSH POKE-THRU FOR POWER FOR MODULAR WORKSTATIONS. REFER TO A1.31.
FLUSH POKE-THRU FOR DATA/COMMUNICATIONS FOR MODULAR WORKSTATIONS REFER TO A1.31.
FLUSH POKE-THRU FOR DATA/COMMUNICATIONS FOR RECEPTION DESK REFER TO A1.31.
A1.31 FOR POKE-THRU SPECIFICATIONS
PENETRATIONS, CONTRACTOR TO X-RAY ALL CORE LOCATIONS. FIRESAFE ALL OPENINGS. REFER TO
FLOOR CORE LOCATIONS TO BE VERIFIED BY STAFFELBACH/MARCUS & MILLICHAP PRIOR TO FLOOR
06 REFER 02/A1.32 FOR BREAK/COPY ROOM POWER REQUIREMENTS.
REFER TO SHEET A1.31 AND 04/A1.32 FOR CONFERENCE ROOM POWER REQUIREMENTS.
REFER TO SHEET A1.31 AND 14/A1.32 FOR RECEPTION POWER REQUIREMENTS.
MOVABLE ADA COMPLIANT RECEPTION DESK BY FURNITURE VENDOR
05 REFER TO SHEET A1.31 AND 12/A1.32 FOR SERVER ROOM POWER REQUIREMENTS.
14
"E" = EXISTING OUTLET TO REMAIN
"R" = EXISTING OUTLET TO BE RELOCATED (PATCH WALL)
SUBSCRIPTS BY OUTLETS INDICATE:
ELECTRICAL SHOWN ON PLAN IS NEW, UNLESS NOTED OTHERWISE.
NON-STANDARD DEVICES AND COVER PLATES TO MATCH NEW SPECIFIED DEVICES AND COVER PLATES.
SECTION 16900 SWITCHES AND COVERS UNLESS NOTED OTHERWISE. RETROFIT ALL EXISTING
ALL NEW OUTLET RECEPTACLES AND COVER PLATES SHALL BE AS SPECIFIED ON SHEET A0.01 UNDER
DEVICES AND COVER PLATES THAT ARE NON-STANDARD WITH NEW WHITE DEVICES.
AND DOCUMENT NEW OR EXISTING CIRCUIT NUMBERS IN AS-BUILT DRAWINGS. RETROFIT ALL EXISTING
CONTRACTOR TO ENSURE THAT ALL "EXISTING TO REMAIN" DUPLEX OUTLETS ARE IN WORKING ORDER,
POWER FOR TENANT PROVIDED PLASMA SCREEN. REFER 14/A1.32 FOR REQUIREMENTS.
CARD READER TO FIRE SYSTEM.
FROM DOOR FRAME. SHOULD LOCAL CODE REQUIRE CONDUIT PROVIDE AS REQUIRED. CONTRACTOR TO TIE
PROVIDE RING AND STRING FOR SECURITY VENDOR SUPPLIED CARD READER . OFFSET CARD READER 6"
FIRE-DROP RELAY. SECURITY VENDOR TO TIE CARD READER INTO FIRE-DROP RELAY. CONTRACTOR TO
CONTRACTOR TO PROVIDE FIRE RATED J-BOX AND TIE-IN FOR CARD READER ACCESS TO BUILDING
12/A2.10 FOR EXACT LOCATION
FROM BUS BAR TO TENANTS DATA RACKS. REFER TO A0.02 FOR SPECIFICATIONS FOR GB-1. REFER TO
BE MOUNTED AT 82" A.F.F. TENANTS CABLING VENDOR TO PROVIDE AND INSTALL #6 AWG GROUND WIRE
AND CONNECT TO BUS BAR. LOCATE GROUNDING BAR WITHIN 4' OF TENANT'S DATA RACKS. BUS BAR TO
GC TO PROVIDE AND INSTALL #6 AWG GROUND WIRE FROM NEAREST APPROPRIATE SOURCE IN CEILING
COORDINATION.
CONTRACTOR TO PROVIDE STAFFELBACH WITH FIELD DIMENSIONS AS REQUIRED FOR FURNITURE
15
PROJECTOR. REFER TO 02/A1.41 FOR EXACT LOCATION OF OUTLET.
PLENUM MOUNTED JUNCTION BOX FOR CEILING MOUNTED DUPLEX OUTLET FOR TENANT PROVIDED
DIMENSION IS INDICATED)
(SUBSCRIPT INDICATES MOUNTING HEIGHT AFF - 14" UNLESS HEIGHT
WALL-MOUNTED JUNCTION BOX FOR POWER TO SYSTEMS FURNITURE
01
02
02
02
02
02
02
02
03
04
05
06
07
08
08
08
09
10
11 12
13
14
15
R
F
-
1
C
M-
1
D
W
-
1
G
D-
1
MW
-
1
WH
-
1
PROVIDE AND INSTALL ALL ELECTRIFIED STRIKES. PROVIDE CONDUIT AS REQ'D BY CODE
ELECTRICAL DETAILS. CONTRACTOR TO PROVIDE RING AND STRING FOR ALL LOW VOLTAGE CABLING,
TENANT IS TO HAVE CARD READERS AT DOOR(S) 500, 502 AND 519 REFER TO MEP DRAWINGS FOR
12
'
-
4
•
"
7
'
-
8
ƒ
"
TYPICAL THROUGHOUT LIMIT OF WORK
MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED BLANK PLATE FOR TENANT A/V VENDOR (SUBSCRIPT INDICATES
FEC FEC
OM
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
5
4
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
_
3
1
flo
o
r
c
o
r
e
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
MODEL/DESCRIPTION:
MANUFACTURER:
MODEL/DESCRIPTION:
MANUFACTURER:
PTD-1: FLUSH POKE-THRU DEVICE: RECEPTION DESK
PTD-2: FLUSH POKE-THRU DEVICE: COPIER
PTD-3: FLUSH POKE-THRU DEVICE: MULTIPLE WORKSTATIONS
PTD-4: FLUSH POKE-THRU DEVICE: MULTIPLE WORKSTATIONS
NOTE:
NOTE:
FINISH:
MODEL:
MANUFACTURER:
PTD-5: FLUSH POKE-THRU DEVICE: SINGLE WORKSTATION
REFER A1.31 FOR LOCATION AND DETAILS
COMBINATION DEVICE FOR POWER AND DATA
BLACK
4FFATC
WIREMOLD
NOTES:
FINISH:
MODEL:
MANUFACTURER:
" ACTUAL HOLE DIAMETER)16
1REQUIRED 3" CORE HOLE (3
ASSEMBLY PLATE TO MAINTAIN FIRE CLASSIFCATION
WITH A CONDUIT CONNECTOR (NOT INCLUDED) AT THE ADAPTER
THREADED CONDUIT OPENINGS AND CLOSURE PLUGS. MUST BE USED
UNIT IS COMPLETE WITH COMBINATION 1‚" AND 2" TRADE SIZE
REFER A1.31 FOR LOCATION AND DETAILS
DEVICE FOR DATA
BLACK
RC9AM2TC
WIREMOLD
NOTES:
FINISH:
MODEL:
MANUFACTURER:
" ACTUAL HOLE DIAMETER)16
1REQUIRED 3" CORE HOLE (3
ASSEMBLY PLATE TO MAINTAIN FIRE CLASSIFCATION
WITH A CONDUIT CONNECTOR (NOT INCLUDED) AT THE ADAPTER
THREADED CONDUIT OPENINGS AND CLOSURE PLUGS. MUST BE USED
UNIT IS COMPLETE WITH COMBINATION 1‚" AND 2" TRADE SIZE
REFER A1.31 FOR LOCATION AND DETAILS
DEVICE FOR POWER
BLACK
RC9AM2TC
WIREMOLD
2 DUPLEX OUTLETS AND 1 DATA OUTLET (6ACT8A)
6" DIAMENTER CORE
WIREMOLD 6AT - 6ATCBK
LEGRAND
4" DIAMETER CORE WITH NEMA 5-20R AND DATA
WIREMOLD RC4
LEGRAND
OFFICEOFFICEOFFICERM OFFICE
OFFICE OFFICE OFFICEBREAK/COPY STORAGE
OFFICE
+48
+17
SERVER RECEPTION
COAT
CONFERENCE
SMALL
OFFICEOFFICE
CONFERENCE
LARGE
PD
P
D
+44+44+44
+44 +44 +44
+44
+17
+17+17
S
CR
C
R
T
V
+66
+36
5-20 R
NEMA
5-20 R
NEMA
+17
C
R
J
514 515 516 517 518
501 500
513 512 511 510 509 508 507 503
502
505 504
STOR.
OFFICE
OPEN
506
OFFICE
OPEN
519
E EEEEEEE
E
E
E
E
E
E
E
E E
E
E
E
+48
WH
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
RK
„" = 1'-0"
A1.31
KEYED NOTES
NOT TO SCALESYMBOLS LEGEND 02
THROUGHOUT LIMIT OF WORK.
CONTRACTOR TO PROVIDE AND INSTALL CONDUIT, RING AND STRING FOR ALL DATA OUTLETS, TYPICAL 05
PLAN
FLOOR CORE LOCATION
POWER/COMMUNICATIONS
FLOOR CORE GENERAL NOTES
01.
02.
03.
AND CODES/ORDINANCES.
ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF THE MANUFACTURER
PENETRATIONS. INSTALL FIRE PROOFING AT ALL PENETRATIONS PER LOCAL CODES AND ORDINANCES.
REQUIRED BY ENGINEER INCLUDING, BUT NOT LIMITED TO SLAB X-RAY, PRIOR TO CONDUCTING ANY SLAB
VERIFY TYPE OF FLOOR SLAB WITH BUILDING'S STRUCTURAL ENGINEER. PROVIDE ALL SAFEGUARDS AS
04.
05.
06.
LOCATION ONLY. REFER TO ELECTRICAL ENGINEERING DOCUMENTS FOR CODE COMPLIANCE.
THIS DRAWING HAS BEEN PREPARED TO ASSIST THE OWNER. ARCHITECT'S POWER PLAN INDICATES
07.
08.
09.
INSTALLATION INDICATED.
LABORATORIES INC. IN EVERY CASE WHERE SUCH A STANDARD HAS BEEN ESTABLISHED FOR THE
ALL MATERIALS REQUIRED SHALL CONFORM WITH THE STANDARDS SET BY THE UNDERWRITERS
MEP DRAWINGS AND REPORT ANY DISCREPANCIES IMMEDIATELY TO STAFFELBACH.
CONTRACTOR IS TO COMPARE ARCHITECTURAL POWER/COMMUNICATIONS PLAN WITH ASSOCIATED
AUTHORITIES HAVING JURISDICTION.
NATIONAL BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES AND TELEPHONE COMPANIES, AND OTHER
ALL WORK IS TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER,
WORK AS SHOWN OR IMPLIED ON ALL PLANS.
CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL DEVICES AND PERFORM ALL ELECTRICAL
RESTRICTIVE).
SPAN OR AS REQUIRED FOR COMPLIANCE WITH APPLICABLE UL LISTING, (WHICHEVER MAY BE THE MOST
TWO (2'-0") FEET O.C. AND NOT MORE THAN ONE (1) HOLE PER 65 SQUARE FEET OF AREA OF FLOOR
"POKE-THRU" ELECTRICAL DEVICES, WHEN PLACED IN MULTIPLES, MUST HAVE A MINIMUM SEPARATION OF
ARCHITECTS POWER PLAN.
ELECTRICAL/DATA AND LIGHT SWITCH LOCATIONS WITH FURNITURE AND EQUIPMENT SHOWN ON
WITH EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY FROM PLAN. COORDINATE
CONTRACTOR TO FIELD COORDINATE LOCATIONS OF ALL NEW POWER AND COMMUNICATIONS OUTLETS
FLOOR CORE SPECIFICATIONS
01
PENETRATIONS, CONTRACTOR TO X-RAY ALL CORE LOCATIONS. FIRESAFE ALL OPENINGS.
FLOOR CORE LOCATIONS TO BE VERIFIED BY STAFFELBACH/MARCUS & MILLICHAP PRIOR TO FLOOR
02
03
04 CONTRACTOR IS REQUIRED TO CONNECT FURNITURE WHIPS TO BUILDING POWER
CORE DIAGRAM
CONFERENCE ROOM
NOT TO SCALE12
REFER TO PTD-3 FOR SPECIFICATION
FLUSH POKE-THRU FOR POWER FOR MODULAR WORKSTATIONS
REFER TO PTD-4 FOR SPECIFICATION
FLUSH POKE-THRU FOR DATA/COMMUNICATIONS FOR MODULAR WORKSTATIONS
REFER TO PLAN FOR POKE THRU DESIGNATION
REFER PTD-1/PTD-2 OR PTD-5 FOR SPECIFICATION
FLUSH POKE-THRU FOR DATA/COMMUNICATIONS FOR RECEPTION DESK
POKE-THRU CONFIGURATIONS
WORKSTATION
PTD-5 - POWER/DATA FOR SINGLE
WORKSTATIONS
PTD-4 - DATA FOR MULTIPLE
CONTRACTOR)
FURNITURE WHIP (BY
FOR CONNECTION TO
2" CONDUIT OPENING
FOR ADDITIONAL NOTES
REFER TO FLOOR CORE SPECIFICATIONS
1•" CONDUIT FOR VOICE/DATA
2" CONDUIT FOR FUTURE TENANT EQUIPMENT
LEGEND
FINISHED CEILING
NO 90° BENDS
SHOWN FOR REFERENCE ONLY
TABLE BY OTHERS
PROJECTOR BY OTHERS
COILED 10'COILED 10'
S
C
R
E
E
N
W
A
L
L
E
L
E
V
A
T
IO
N
A
T
LEG 'A'
TABLE
LEG 'B'
TABLE
FLOOR
FINISHED
LINE OF
1" CONDUIT FOR ELECTRICAL
INSTALLED BY CONTRACTOR
PROJECTION SCREEN BY OTHERS,
OTHERS
CREDENZA BY
**ALL CONDUITS TO BE ROUTED TO WALL NEAREST PROJECTION
SCREEN PROVIDE INSULLATED BUSHING AND PULL STRING ABOVE
CEILING.**
**CONTRACTOR TO FIELD VERIFY CORE DIMENSIONS PRIOR TO
CORING, REPORT ANY DISCREPANCIES TO STAFFELBACH IMMEDIATELY**
**NO 90 DEGREE CONDUIT BENDS WILL BE ACCEPTED**
LARGE CONFERENCE ROOM FLOOR OUTLET DIAGRAM
TYPICAL POWER
TYPICAL DATA OUTLETFUTURE USE
FOR TENANT
PROJECTION
SCREEN PROVIDED
BY TENANT,
INSTALLED BY
GENERAL
CONTRACTOR.
LINE OF CONDUIT TERMINATION
(2-3" ABOVE FINISHED CEILING)
CONDUIT TERMINATION
2
-
3
"
**CONDUIT SHOWN FOR M&M REQUIREMENTS AND GENERAL LOCATION
ONLY, CONTRACTOR TO CONFIRM FINAL LOCATIONS WITH EXISTING
CONDITIONS**
**CONTRACTOR TO ENSURE CORE FOR ALL CONDUITS TO BE 4"
MAXIMUM, ALL DIMENSIONS ARE TO CENTER OF CORE/OPENING AT
TABLE LEG**
4•" CONDUIT
4
"
2" CONDUIT FOR FUTURE TENANT USE.
1" CONDUIT FOR POWER TO TERMINATE IN TIGHT WHIP
TO A STANDARD DUPLEX OUTLET
CONTRACTOR TO PROVIDE AND INSTALL CEILING MOUNTED
DUPLEX FOR TENANT PROVIDED PROJECTOR AS INDICATED ON
A1.40.
ELEVATION AT SCREEN WALL CONFERENCE ROOM
CORE DIAGRAM
CONF. ROOM DIAGRAM KEYED NOTES
O
F
C
O
N
D
U
IT
T
O
T
O
P
SPECIFICATION.
FLUSH POKE-THRU DEVICE AS DESIGNATED. REFER TO FLOOR CORE SPECIFICATIONS FOR DEVICE
CAP AS REQUIRED
FURNITURE WHIP FOR POWER
1‚" CONDUIT OPENING FOR
FOR CABLING VENDOR
TO PROVIDE RING AND STRING
FOR DATA. CONTRACTOR
1‚" CONDUIT OPENING
20 AMP DUPLEX
68REC RECEPTACLE
CABLING VENDOR
RING AND STRING FOR
FOR DATA. PROVIDE
6ACT8A RECEPTACLE
AND STRING FOR CABLING VENDOR
FOR DATA. PROVIDE RING
ƒ" CONDUIT OPENING
PTD-1 - POWER/DATA FOR RECEPTION DESK PTD-2 - POWER/DATA FOR OPEN OFFICE COPIER
NEMA 5-20R OUTLET
2" CONDUIT OPENING (NOT USED)
CABLING VENDOR
STRING FOR
PROVIDE RING AND
CONTRACTOR TO
DATA OUTLET.
06 REFER TO 02/A1.31 FOR CONFERENCE ROOM POWER AND DATA REQUIREMENTS.
07
REFER TO 03/A1.32 FOR CONFERENCE ROOM POWER/DATA DIMENSIONS & REQUIREMENTS.
2" CONDUIT FOR FUTURE EQUIPMENT
1" CONDUIT FOR ELECTRICAL
1•" CONDUIT FOR VOICE/DATA
FLOOR LINE
DATA CONDUITS TO
CONTINUE TO PLENUM
CONTRACTOR TO PROVIDE SINGLE 4•" CONDUIT SLEAVE TO
ACCOMMODATE CONDUITS FOR POWER/DATA/AUDIO VISUAL
EQUIPMENT IN TABLE LEG WHERE INDICATED ON PLAN. PROVIDE
FLOOR FILL AND FIRE SEAL AS REQUIRED BY CODE. FIELD
VERIFY EXACT LOCATION OF POKE-THRU DEVICE AND VERIFY
CONDITIONS OF SPACE BELOW. COORDINATE ACCESS OF BELOW
TENANT SPACE WITH LANDLORD.
WORKSTATIONS
PTD-3 - POWER FOR MULTIPLE
10 FURNITURE WHIP LOCATION PLAN
FLOOR CORE LOCATION PLAN
ENTERS THE FLOOR CORE.
CONTRACTOR TO PROVIDE AND INSTALL LIQUID TIGHT 90 DEGREE CONNECTION WHERE FURNITURE WHIP
SLEEVE (INTERIOR DIMENSION)
A1
A2
A3
A4
A5
A6
A6
A1
A2
A4A5 A5 A4
A3
A1
PTD-1
PTD-3 PTD-3
PTD-4 PTD-4
1'-3•"
7
'
-
•
"
2
'
-
3
"
11'
-
11"
25'-•"17'-10•"
01
02
02
02
02
02
8
'
-
0
"
8
'
-
0
"
8'-2"9'-0"
03
04 05
06
07
07
07
07
TYPICAL THROUGHOUT LIMIT OF WORK
1•" CONDUIT FOR VOICE/DATA. CONTRACTOR TO PROVIDE
CONDUIT, RING AND STRING. RING AND STRING TO BE LABELED
'AA' AT TABLE LEG AND IN PLENUM.
1 •" CONDUIT FOR VOICE/DATA. CONTRACTOR TO PROVIDE
CONDUIT, RING AND STRING. RING AND STRING TO BE LABELED
'BB' AT TABLE LEG AND IN PLENUM.
2
'
-
3
"
11'
-
11"
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
2
3
:
4
3
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
il
l
i
c
h
a
p
\In
d
ia
n
a
p
o
li
s
\
In
d
ia
n
a
p
o
li
s
2
0
1
3
\
C
A
D
D
fil
e
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
ti
o
n
D
o
c
u
m
e
n
t
s
\
a
1
_
3
2
_
p
o
w
e
r
e
n
la
r
g
e
d
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
0204AT CONFERENCE ROOM
ENLARGED POWER PLAN
12AT SERVER ROOM
ENLARGED POWER PLAN14AT RECEPTION
ENLARGED POWER PLAN
AT BREAK/COPY
ENLARGED POWER PLAN
CR
RECEPTION DESK BY FURNITURE VENDOR
CR
‚" = 1'-0"
•" = 1'-0"1" = 1'-0"
ALL OUTLETS ARE TO BE DEDICATED AS INDICATED ON PLAN.
05KEYED NOTES & SYMBOLS
POWER PLAN AT BREAK/COPY
CONTRACTOR TO PROVIDE POWER FOR WATER HEATER AT 17" AFF AS INDICATED ON PLAN.
CONTRACTOR TO PROVIDE POWER FOR DISHWASHER AT 17" AFF AS INDICATED ON PLAN.
ELEVATIONS/SHEET A4.10 FOR EXACT LOCATIONS.
CONTRACTOR TO MOUNT ALL OUTLETS ABOVE COUNTERTOP HORIZONTALLY AT 44" AFF. SEE
BREAK/COPY KEYED NOTES
HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED DUPLEX ELECTRICAL OUTLET, 120 VOLT (SUBSCRIPT INDICATES MOUNTING
MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED DUPLEX ELECTRICAL OUTLET ON SEPARATE CIRCUIT (SUBSCRIPT INDICATES
HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
JACK, CONTRACTOR TO PROVIDE CONDUIT RING AND STRING (SUBSCRIPT INDICATES MOUNTING
WALL-MOUNTED DATA OUTLET, PRIMARY NETWORK CABLE BLUE CAT 5E CABLE WITH ORANGE
BREAK/COPY SYMBOLS
10KEYED NOTES & SYMBOLS
POWER PLAN AT CONFERENCE ROOM
FLOOR PENETRATIONS, CONTRACTOR TO X-RAY ALL CORE LOCATIONS. FIRESAFE ALL OPENINGS.
FLOOR CORE LOCATIONS TO BE VERIFIED BY STAFFELBACH/MARCUS & MILLICHAP PRIOR TO
REFER TO 02/A1.31 FOR CONFERENCE ROOM POWER AND DATA REQUIREMENTS.
CENTERED ON WALL.
ON SHEET A1.50. WHERE INDICATED ON PLAN BLOCKING AND VISUAL AID BOARD TO BE
AT 2'-10" AFF. DRYWALL TO BE APPLIED DIRECTLY TO BLOCKING AND FINISHED AS SPECIFIED
PARTITION FOR TENANT PROVIDED VISUAL AID BOARD. BOTTOM OF PLYWOOD TO BE MOUNTED
CONTRACTOR TO PROVIDE 4' (W) X 8' (H) PLYWOOD BLOCKING MOUNTED HORIZONTALLY IN
CONFERENCE ROOM KEYED NOTES
CONFERENCE ROOM SYMBOLS
HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED DUPLEX ELECTRICAL OUTLET, 120 VOLT (SUBSCRIPT INDICATES MOUNTING
HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED QUADRAPLEX ELECTRICAL OUTLET, 120 VOLT (SUBSCRIPT INDICATES MOUNTING
MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
JACK, CONTRACTOR TO PROVIDE CONDUIT RING AND STRING (SUBSCRIPT INDICATES
WALL-MOUNTED DATA OUTLET, PRIMARY NETWORK CABLE BLUE CAT 5E CABLE WITH ORANGE
(SUBSCRIPT INDICATES MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
CAT 5E CABLE WITH ORANGE JACKS, CONTRACTOR TO PROVIDE CONDUIT RING AND STRING
WALL-MOUNTED DATA OUTLET, DUAL PRIMARY NETWORK LOCATION (2 DATA JACKS) BLUE
15KEYED NOTES & SYMBOLS
POWER PLAN AT SERVER ROOM
SERVER ROOM SYMBOLS
SERVER ROOM KEYED NOTES
FOR SPECIFICATION
INSTALL #6 AWG GROUND WIRE FROM BUS BAR TO TENANTS DATA RACKS. REFER TO SHEET A0.00
DATA RACKS. BUS BAR TO BE MOUNTED AT 82" A.F.F. TENANTS CABLING VENDOR TO PROVIDE AND
SOURCE IN CEILING AND CONNECT TO BUS BAR. LOCATE GROUNDING BAR WITHIN 4' OF TENANT'S
CONTRACTOR TO PROVIDE AND INSTALL #6 AWG GROUND WIRE FROM NEAREST APPROPRIATE
READER 6" FROM DOOR FRAME. SHOULD LOCAL CODE REQUIRE CONDUIT PROVIDE AS REQUIRED.
TO PROVIDE RING AND STRING FOR SECURITY VENDOR SUPPLIED CARD READER . OFFSET CARD
FIRE-DROP RELAY. SECURITY VENDOR TO TIE CARD READER INTO FIRE-DROP RELAY. CONTRACTOR
CONTRACTOR TO PROVIDE FIRE RATED J-BOX AND TIE-IN FOR CARD READER ACCESS TO BUILDING
NEMA L5-30 AMP TO BE TWIST LOCK AND 125V
CONTRACTOR TO PROVIDE AND INSTALL NEMA L5-30 AMP AT 17" AFF AS INDICATED ON PLAN.
TYPICAL THROUGHOUT LIMIT OF WORK.
CONTRACTOR TO PROVIDE AND INSTALL CONDUIT, RING AND STRING FOR ALL DATA OUTLETS,
TO CEILING AS POSSIBLE. SMOOTH AND PAINT PLYWOOD AS SCHEDULED.
FOR TENANT'S TELEPHONE EQUIPMENT ON ALL WALLS IN SERVER ROOM. MOUNT PLYWOOD AS CLOSE
PROVIDE 8' (H) X ƒ" A.C. GRADE NON COMBUSTABLE PLYWOOD BACKBOARD MOUNTED VERTICALLY
MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED QUADRAPLEX ELECTRICAL OUTLET ON SEPARATE CIRCUIT (SUBSCRIPT INDICATES
RELAY.
FIRE-DROP RELAY, TENANT VENDOR TO TIE CARD READER TIE CARD READER INTO FIRE-DROP
MOUNT @ 48" AFF ELECTRICIAN TO PROVIDE TIE-IN FOR CARD READER ACCESS TO BUILDING
CARD READER BY TENANT VENDOR- CONTRACTOR TO PROVIDE CONDUIT, RING AND STRING -
RECEPTION KEYED NOTES
RECEPTION ROOM SYMBOLS
TO BE INSTALLED BY CONTRACTOR. REFER TO PLAN FOR POWER REQUIREMENTS.
49.1" W. TOP OF PLASMA TO BE MOUNTED AT 74" AFF (BOTTOM OF MONITOR AT 46" AFF). PLASMA
AND MOUNTING BRACKET TO BE PROVIDED BY MARCUS & MILLICHAP. PLASMA SCREEN IS 28•" H X
POWER FOR TENANT PROVIDED PLASMA SCREEN. PROVIDE BLOCKING AT 66" AFF. PLASMA SCREEN
PENETRATIONS, CONTRACTOR TO X-RAY ALL CORE LOCATIONS. FIRESAFE ALL OPENINGS.
FLOOR CORE LOCATIONS TO BE VERIFIED BY STAFFELBACH/MARCUS & MILLICHAP PRIOR TO FLOOR
READER 6" FROM DOOR FRAME. SHOULD LOCAL CODE REQUIRE CONDUIT PROVIDE AS REQUIRED.
TO PROVIDE RING AND STRING FOR SECURITY VENDOR SUPPLIED CARD READER . OFFSET CARD
FIRE-DROP RELAY. SECURITY VENDOR TO TIE CARD READER INTO FIRE-DROP RELAY. CONTRACTOR
CONTRACTOR TO PROVIDE FIRE RATED J-BOX AND TIE-IN FOR CARD READER ACCESS TO BUILDING
HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
WALL-MOUNTED DUPLEX ELECTRICAL OUTLET, 120 VOLT (SUBSCRIPT INDICATES MOUNTING
RELAY.
FIRE-DROP RELAY, TENANT VENDOR TO TIE CARD READER TIE CARD READER INTO FIRE-DROP
MOUNT @ 48" AFF ELECTRICIAN TO PROVIDE TIE-IN FOR CARD READER ACCESS TO BUILDING
CARD READER BY TENANT VENDOR- CONTRACTOR TO PROVIDE CONDUIT, RING AND STRING -
MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
ORANGE JACK, CONTRACTOR TO PROVIDE CONDUIT RING AND STRING (SUBSCRIPT INDICATES
WALL-MOUNTED DATA OUTLET, PRIMARY NETWORK CABLE BLUE CAT 5E CABLE WITH
(SUBSCRIPT INDICATES MOUNTING HEIGHT AFF - 17" UNLESS HEIGHT IS INDICATED)
5E CABLE WITH ORANGE JACKS, CONTRACTOR TO PROVIDE CONDUIT RING AND STRING
WALL-MOUNTED DATA OUTLET, DUAL PRIMARY NETWORK LOCATION (2 DATA JACKS) BLUE CAT
•" = 1'-0"
20KEYED NOTES & SYMBOLS
POWER PLAN AT RECEPTION
NEMA L5-30 DEDICATED RECEPTACLE - TWIST LOCK
02/A1.31 FOR ADDITIONAL DETAILS
CONDUIT SLEVE - 4 1/2" CONDUIT SLEVE (INTERIOR CLEAR DIMENSION IS 4 1/2") REFER TO
SWITCH FOR GARBAGE DISPOSAL TO BE MOUNTED HORIZONTALLY.
A1
A2
A3
A4
A5
A6
A7
REFER TO 05/A1.32 FOR KEYED NOTESREFER TO 10/A1.32 FOR KEYED NOTES
B1
B2
B3
B4
B5
REFER TO 20/A1.32 FOR KEYED NOTES REFER TO 15/A1.32 FOR KEYED NOTES
C1
C2
C3
C4
C5
D1
D2
D3
D4
D5
FOR POKE-THRU DEVICE AT RECEPTION DESK.
CONTRACTOR TO REFER TO PTD-1/SHEET 12/A1.31 UNDER APPLIANCE/PRODUCT SPECIFICATIONS
PROVIDED, CEILING MOUNTED PROJECTOR. REFER 02/A1.41 FOR LOCATION.
CONTRACTOR TO PROVIDE AND INSTALL CEILING MOUNTED DUPLEX OUTLET FOR TENANT
BOX. REFER TO ELEVATION (SHEET A4.10) FOR EXACT LOCATION.
WATER LINE FOR TENANT COFFEE MAKER TO BE ROUTED THROUGH TENANT MILLWORK. NO WATER
ELEVATION (SHEET A4.10) FOR EXACT LOCATION.
WATER LINE FOR TENANT REFRIGERATOR TO BE ROUTED THROUGH TENANT MILLWORK. REFER TO
C
R
+48
C1
C4
C2
C5
C5
C5
D1
D2
D3
D4
D5
CONFERENCING EQUIPMENT WHERE INDICATED ON PLAN.
CONTRACTOR TO PROVIDE DUPLEX AND RING AND STRING FOR BLANK PLATE FOR TENANT VIDEO
ROOM
LIMIT OF SERVER
TYPICAL THOUGHOUT
1'-3•"
7
'
-
•
"
A1
A5
A2
A3 A4
B2
B1
B3
CONFERENCE ROOM
LIMIT OF
TYPICAL THOUGHOUT
B1
B5
B4
A6A7
COPY/BREAK ROOM
LIMIT OF
TYPICAL THOUGHOUT
C3
8"1'-4"
+17
NEMA L5-30NEMA 5-20R
+17
C
R
T
V
+66
+44+44+44
+44 +44 +44
+44
+17
+17+17
S+36
5-20 R
NEMA
5-20 R
NEMA
+48
WH
CONFERENCE
LARGE
J
OFFICE
OPEN
LIM
IT
O
F
W
O
R
K
ENLARGED POWER PLAN
A1.32
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
5
7
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
_
4
0
r
c
p
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
10 floor 5
" = 1'-0"8
1
NORTH
PLAN
OFFICEOFFICEOFFICERM OFFICE
OFFICE OFFICE OFFICEBREAK/COPY STORAGE
OFFICE
SERVER RECEPTION
COAT
CONFERENCE
SMALL
OFFICEOFFICE
CONFERENCE
LARGE
B
B B
B
B
B1 B1
B1B1
B
C1 C1
C1C1
C1C1
D
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B1
B1
B BBBBB
BBBBBB
BBBBBB
B B B B B
B1
S
D
D
D
DD
S
S
S S S
S S S S S S S
S
S
S
3
EE EE
C1 C1 C1
C1C1C1
E
E
514 515 516 517 518
501 500
513 512 511 510 509 508 507 503
502
505 504
STOR.
OFFICE
OPEN
506
OFFICE
OPEN
519
9'-0"
9'-0"
9'-0"
9'-0"
3S
3
S
3
B
B
B
C1C1
B1
E
E
E
0 4 8 16 32
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
RK
REFLECTED CEILING PLAN
PLAN
REFLECTED CEILING
SYMBOLS LEGENDKEYED NOTES A1.40
UNLESS NOTED OTHERWISE.
ALL NEW OR RELOCATED LIGHT FIXTURES ARE TO BE CENTERED IN CEILING TILE,
AS REQUIRED TO MATCH ALL NEW DEVICES IN CEILING.
ANY RE-USED CEILING DIFFUSER/RETURN AIR GRILL(S) SHALL BE CLEANED, PAINTED
MOUNTED.
AND VISUAL ALARM DEVICES SHALL BE WHITE WITH RED LETTERING AND CEILING
COMPLY WITH ALL STATE REGULATIONS. UNLESS NOTED OTHERWISE, ALL AUDIBLE
ROOMS, BREAK ROOMS, MEETING ROOMS, CONFERENCE ROOMS, ETC AND SHALL
EMPLOYEE WORK AREAS, INCLUDING BUT NOT LIMITED TO STORAGE ROOMS, WORK
AUDIBLE AND VISUAL ALARM DEVICES SHALL BE INSTALLED IN ALL COMMON USE
DUCTS WITH INSULATION.
LOCAL, STATE AND FEDERAL CODES (INCLUDING, BUT NOT LIMITED TO) WRAPPING
ALL EXISTING HVAC SHALL BE BROUGHT INTO COMPLIANCE WITH ALL APPLICABLE
REQUIRED. ALL LAMPS SHALL BE CONSISTENT IN COLOR THROUGHOUT.
OPERABLE CONDITION. CLEAN LENSES AND REPLACE LAMPS, BALLASTS, AND LENSES AS
CONTRACTOR TO VERIFY ALL EXISTING FIXTURES, BALLASTS, AND LIGHTS ARE IN
AND COVER PLATES.
RECEPTACLES AND COVER PLATES TO MATCH NEW SPECIFIED RECEPTACLES
UNLESS NOTED OTHERWISE. RETROFIT ALL EXISTING NON-STANDARD
LOCATION. ALL NEW COVER PLATES SHALL BE AS SPECIFIED ON SHEET A0.01
TO COMPLY WITH ADA TITLE III REQUIREMENTS. REFER TO SHEET A0.01 FOR
ALL NEW SWITCHES TO BE MOUNTED AT 48" A.F.F. TO CENTERLINE OF SWITCH
PROVIDE AND INSTALL ADDITIONAL SWITCHES AS REQUIRED.
OF LIGHT FIXTURES PER CIRCUIT AND QUANTITY OF SWITCHES REQUIRED.
LIGHT SWITCH INDICATES LOCATION ONLY. CONTRACTOR TO VERIFY QUANTITY
TYPES FOR WALL TO CEILING CONDITIONS.
REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. REFERENCE TO WALL
IMPLIED ON ALL PLANS. ALL FIXTURES ARE NEW UNLESS INDICATED OTHERWISE.
DEVICES AND HVAC EQUIPMENT AND SHALL PERFORM ALL WORK AS SHOWN ON OR
CONTRACTOR SHALL FURNISH AND INSTALL ALL LIGHTS, SWITCHES, EMERGENCY
COMPLY WITH ADA TITLE III AND TEXAS ACCESSIBILITY STANDARDS.
WARNING SYSTEMS SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARM DEVICES THAT
APPLICABLE FEDERAL, STATE, AND LOCAL CODE REQUIREMENTS. ALL EMERGENCY
CONTRACTOR TO PROVIDE AND INSTALL ALL EMERGENCY WARNING SYSTEMS PER ALL
I.E.: FIRE ALARMS, DETECTORS, SPEAKERS, STROBES, 24 HOUR EMERGENCY LIGHTS, ETC.
CONTRACTOR SHALL PROVIDE AND RELOCATE FIRE PROTECTION DEVICES AS REQUIRED,
CONFLICTS.
EQUIPMENT IN THEIR SCOPE OF WORK AND CONTRACT. NOTIFY ARCHITECT OF ANY
FIXTURES SHOWN. CONTRACTOR IS RESPONSIBLE FOR ANY RELOCATION OF HVAC
COORDINATE LOCATIONS OF NEW AND EXISTING HVAC EQUIPMENT WITH LIGHT
CONTRACTOR TO FIELD VERIFY PRIOR TO START OF CONSTRUCTION AND
PLANS AND LOCATED FREE AND CLEAR OF FURNITURE SYSTEMS.
THERMOSTATS SHALL BE MOUNTED AT 48" AFF AS REQUIRED BY MECHANICAL
CENTERED IN CEILING TILE.
AREAS AFFECTED BY DEMOLITION/CONSTRUCTION. SPRINKLER HEADS ARE TO BE
CONTRACTOR TO RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED PER CODE IN
NEAREST FIRE EXIT.
TRAVEL TO NEAREST FIRE EXIT. EXIT SIGN DIRECTIONAL INDICATIONS IN DIRECTION OF
REQUIRED BY BUILDING INSPECTOR. EXIT SIGNS SHALL BE LOCATED IN DIRECTION OF
QUANTITY AND LOCATIONS OF 24 HOUR EMERGENCY LIGHTS AND EXIT LIGHTS
PROVIDE EXIT LIGHTS AS INDICATED ON THE MEP DRAWINGS. CONTRACTOR TO VERIFY
CIRCUITS, UNLESS NOTED OTHERWISE. REFER TO ENGINEERED LIGHTING PLAN.
ALL NEW DOWN LIGHTS AND WALL WASHER GROUPINGS ARE TO BE ON SEPARATE
COMPLIANCE. NOTIFY ARCHITECT OF SUCH CONFLICTS.
BE MADE IN SUCH A WAY AS TO MAINTAIN ENGINEERING DESIGN INTENT/CODE
LAYOUT SHALL TAKE PRECEDENCE. ADJUSTMENT OF CONFLICTING ELEMENTS SHALL
SYSTEM, PLUMBING SYSTEM, EXIT SIGNS OR MECHANICAL EQUIPMENT, LIGHT FIXTURE
SHOULD CONFLICT ARISE BETWEEN LIGHT FIXTURE LAYOUT AND FIRE PROTECTION
BETWEEN CEILING GRID AND ANY OBSTRUCTIONS IN PLENUM.
PRIOR TO INSTALLING FIXTURES, CONTRACTOR SHALL VERIFY ADEQUATE DEPTH
TILE INSTALLATION TO ALLOW FOR PLENUM INSPECTION.
CONTRACTOR SHALL NOTIFY ENGINEER AT LEAST 48 HOURS IN ADVANCE OF CEILING
BOTH SIDES OF ROTATED PARTITIONS AND PLACED EVERY 6'-0" O.C.
AND SMOKE BARRIER - PROTECT ALL OPENINGS". STENCILS SHALL BE LOCATED ON
PROVIDE STENCILING ABOVE LAY-IN CEILING USING THE FOLLOWING VERBIAGE: "FIRE
WIRING WITHIN TENANT'S LEASE SPACE IS THE RESPONSIBILITY OF THE CONTRACTOR.
OTHERWISE IN LIGHT FIXTURE SCHEDULE, THROUGHOUT TENANT'S LEASE SPACE. ALL
FINISH/INSTALL BUILDING STANDARD FLUORESCENT LIGHT FIXTURES, UNLESS NOTED
FIXTURE (U.N.O)
DIMENSIONS SHOWN ARE FROM FACE OF WALL TO CENTERLINE OF LIGHT
DUE TO DAMAGE DURING SUBSEQUENT DEMOLITION OR CONSTRUCTION.
INCLUDED IN SCOPE OF WORK. CONTRACTOR WILL BE RESPONSIBLE FOR ANY REPAIRS
BUILDING OWNER FOR ANY REPAIRS NECESSARY TO THE HVAC SYSTEM NOT
PRIOR TO CONSTRUCTION. CONTRACTOR SHALL PROVIDE SEPARATE ESTIMATE TO
BOXES, FAN POWERED BOXES, LIEBERT (PRECISION COOLING UNITS) AND DUCTWORK
CONTRACTOR TO PERFORM FIELD INSPECTION OF EXISTING HVAC EQUIPMENT, VAV
LIKE LEVEL OF SOUND ATTENUATION.
PLENUM RESULTING FROM DEMOLITION/BUILD-BACK SHALL BE REPAIRED TO
ANY DAMAGE OR MODIFICATIONS TO EXISTING ACOUSTICAL INSULATION IN THE
NEW STROBE LIGHT SEQUENCING THROUGHOUT THE SPACE.
CONTRACTOR IS RESPONSIBLE FOR THE SYNCHRONIZATION OF ALL EXISTING AND
STAFFELBACH.
ASSOCIATED MEP DRAWINGS AND REPORT ANY DISCREPANCIES IMMEDIATELY TO
CONTRACTOR IS TO COMPARE ARCHITECTURAL REFLECTED CEILING PLAN WITH
PATCH AND LEVEL EXISTING CEILING GRID TO BRING TO LIKE-NEW APPEARANCE.
CONTRACTOR TO RE-USE ALL EXISTING TILE AND GRID WHENEVER POSSIBLE.
01.
02.
03.
04.
05.
06.
07.
08.
09.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
CONTRACTOR PRIOR TO SUBSTANTIAL COMPETITION AND CALIBRATE THE THERMOSTATS.
WITH NEW AIR BALANCE REPORT FROM AN APPROVED STATE CERTIFIED HVAC
NEW PARTITION LAYOUT AND IS TO PROVIDE ARCHITECT AND PROPERTY MANAGEMENT
CONTRACTOR IS RESPONSIBLE FOR TEST AND BALANCE OF HVAC AS REQUIRED PER
REFLECTED CEILING PLAN GENERAL NOTES
REQUIRED BY CODE.
APPROVAL. ALL STROBES TO BE WHITE CEILING MOUNTED UNLESS OTHERWISE
CONTRACTOR TO SUBMIT FIRE ALARM PLACEMENT PLAN TO STAFFELBACH FOR
CONSTRUCTION. RELAMP/REPLACE ANY EXISTING FIXTURES TO REMAIN.
FIXTURES, COLOR TEMPERATURE TO BE 4100K. TYPICAL THROUGHOUT
CONTRACTOR TO PROVIDE AND INSTALL COOL WHITE LAMPS IN ALL LIGHT
01
05
02
07
08
09
10
11
17/A6.10 FOR SECTION AT FURR DOWN
INDICATED ON PLAN. REFER TO MILLWORK ELEVATIONS FOR DETAILS. REFER TO
CONTRACTOR TO PROVIDE AND INSTALL GYP BOARD FURR DOWNS WHERE
06
REFER 02/A1.41 FOR CONFERENCE ROOM CEILING AND A/V REQUIREMENTS
REFER 12/A1.41 FOR SERVER ROOM CEILING REQUIREMENTS.
VENDOR. MOUNTED IN CEILING.
REQUIRED BY CODE. SPEAKERS TO BE PROVIDED AND INSTALLED BY CABLING
CONTRACTOR TO PROVIDE AND INSTALL CONDUIT FOR SPEAKER SYSTEM AS
CONSERVATION CODE AS ADOPTED BY THE LOCAL CODE AUTHORITY.
COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL ENERGY
CONTRACTOR SHALL ENSURE THAT ALL LIGHTING AND MECHANICAL SYSTEMS
29.
NEW CEILING GRID AND/OR TILE AS REQUIRED.
APPEARANCE AND TO AVOID CHECKERBOARD EFFECT. CONTRACTOR TO PROVIDE
TILES IN GOOD CONDITION TO BE RELOCATED TO PROVIDE A CONSISTENT
CEILING GRID AND TILES WITH NEW TO MATCH EXISTING. EXISTING CEILING
CONTRACTOR IS TO REPLACE DAMAGED, MISSING, SCRATCHED, OR STAINED
03
04 REFER 14/A1.41 FOR BREAK ROOM CEILING REQUIREMENTS.
REFER 04/A1.41 FOR RECEPTION CEILING REQUIREMENTS
WHERE INDICATED ON PLAN.
PANEL TIE-IN. CONGRACTOR TO PROVIDE 20 AMP CIRCUIT FOR CARD ACCESS
PROVIDE FIRE-RATED J-BOX ABOVE CEILING FOR CARD ACCESS BUILDING FIRE
01
02
03
04
05
05
05
06
S
SS
S
07
07
07
07
08
08
09 10
11
11
11
11
11
OF WORK
THOUGHOUT LIMIT
TYPICAL
ALT#1
08
06 06 06 06 06 06 06
06
06
06
06
17
/
A
6
.
10
09
09
09
EXISTING GRID
TO REMAIN
NEW GRID, ALIGN
TO EXISTING
APPEARANCE AND LIKE-NEW
AND REPLACE DAMAGED/STAINED TILES. VERIFY ALL CEILING TILE IS UNIFORM IN
BUILDING STANDARD 2X2 CEILING GRID TO REMAIN. REUSE SALVAGED CEILING TILE
ARMSRONG: ULTIMA
INDICATED ON PLAN. NEW GRID TO ALIGN TO EXISTING. SPECIFICATION:
500, LARGE CONFERENCE ROOM 503 AND SMALL CONFERENCE ROOM 501 AS
CONTRACTOR TO PROVIDE AND INSTALL NEW CEILING TILE AND GRID IN RECEPTION
D
J
S
S
A
A1
B
B1
E
D
F
BUILDING STANDARD 2X4; VERIFY SPECIFICATION WITH LANDLORD
BUILDING STANDARD 2X2; VERIFY SPECIFICATION WITH LANDLORD
FLU 24 B 2 T8 E 120 G PS
FOCAL POINT - LUNA 2X4 - WITH PERFORATED SHEILDING
FLU 22 B 2 T8 E 120 G PS
FOCAL POINT - LUNA 2X2 - WITH PERFORATED SHEILDING
C
DIMMABLE FIXTURE - FLU 22 B 2 T8 D 120 G PS
FOCAL POINT - LUNA 2X2 - WITH PERFORATED SHEILDING
DIMMABLE FIXTURE - FLU 24 B 2 T8 D 120 G PS
FOCAL POINT - LUNA 2X4 - WITH PERFORATED SHEILDING
BE INSTALLED ON SEPARATE DIMMER SWITCH.
WITH FOUR (4) CRS298QR-S TRACK HEADS. TRACK TO
MAGELLAN LOW VOLTAGE FLEXIBLE 4' TRACK CRS2964-S
HE WILLIAMS LINEAR FLUORESCENT - 75-4--32-EBD1
NEW ILLUMINATED EDGE LIT EMERGENCY EXIT SIGN (W/ GREEN LETTERING)
WITH DIRECTION OF TRAVEL ILLUMINATED
NEW ILLUMINATED EDGE LIT EMERGENCY EXIT SIGN (W/ GREEN LETTERING)
TENANT PROVIDED PROJECTION SCREEN REFER TO A0.02 FOR SPECIFICATION
CEILING MOUNTED JUNCTION BOX
CEILING MOUNTED SPEAKER, INSTALL CONDUIT AS REQUIRED BY CODE
WHITE SINGLE POLE SWITCH WITH MOTION SENSOR
WHITE SINGLE POLE SWITCH
WHITE LIGHT SWITCH WITH DIMMER CONTROL SENSOR SWITCH.
BUILDING STANDARD GRID
HE WILLIAMS SQUARE DOWNLIGHT - PVSQ60-1 26T-EBD1 (DIMMABLE)
C1
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
6
:
5
9
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
_
4
1
r
c
p
_
e
n
la
r
g
e
d
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
A1.41
ENLARGED PLANS
REFLECTED CEILING
02AT CONFERENCE ROOM
ENLARGED REFLECTED CEILING PLAN
12AT SERVER ROOM
ENLARGED REFLECTED CEILING PLAN
04
REFLECTED CEILING PLAN KEYED NOTES
‚" = 1'-0"•" = 1'-0"
1" = 1'-0"
CEILING MOUNTED JUNCTION BOXJ
S
C1
E
J CEILING MOUNTED JUNCTION BOX
D WHITE LIGHT SWITCH WITH DIMMER CONTROL
A
B
AT RECEPTION
ENLARGED REFLECTED CEILING PLAN
LINE INDICATES SWITCHING
C1
E
D WHITE LIGHT SWITCH WITH DIMMER CONTROL
LINE INDICATES SWITCHING
TRACK HEADS (CRS298QR-S).
4' TRACK (CRS2964-S) WITH FOUR (4)
MAGELLAN LOW VOLTAGE FLEXIBLE
CON-TECH LIGHTING
14
•" = 1'-0"
AT BREAK/COPY ROOM
ENLARGED REFLECTED CEILING PLAN
05KEYED NOTES AND SYMBOLS
CONFERENCE ROOM CEILING PLAN
H.E. WILLIAMS - PVSQ60-126T-EB1-VOLT - NO SUBSTITUTIONS
SHEET A0.02.
TENANT PROVIDED PROJECTION SCREEN AS SPECIFIED, REFER TO
CEILING TILE AS INDICATED ON PLAN FOR TENANT PROVIDED PROJECTOR.
CONTRACTOR TO PROVIDE AND INSTALL CEILING MOUNTED DUPLEX ON
SCREEN. REFER TO SHEET A0.02 FOR SPECIFICATION
CONTRACTOR TO INSTALL TENANT PROVIDED RECESSED MANUAL PROJECTION
CONFERENCE ROOM SYMBOLS LEGEND
10KEYED NOTES AND SYMBOLS
RECEPTION CEILING PLAN
H.E. WILLIAMS - PVSQ60-126T-EB1-VOLT - NO SUBSTITUTIONS
RECEPTION SYMBOLS LEGEND
SPECIFICATIONS WITH LANDLORD.
BUILDING STANDARD NEW 2' X 4' FLUORESCENT. VERIFY
NO SUBSTITUTIONS
NEW 2' X 4' FLUORESCENT - FOCAL POINT - FLU24B2T8E120GPS -
WHITE SINGLE POLE SWITCH WITH MOTION SENSOR.
ENGINEER.
THERMOSTATICALLY CONTROLLED EXHAUST FAN. SPECIFIED BY
SERVER ROOM REFLECTED CEILING PLAN KEYED NOTES
RECEPTION REFLECTED CEILING PLAN KEYED NOTES
SERVER ROOM SYMBOLS LEGEND
15KEYED NOTES AND SYMBOLS
SERVER ROOM CEILING PLAN
KEYED NOTES AND SYMBOLS
BREAK/COPY CEILING PLAN20
A
B
SPECIFICATIONS WITH LANDLORD.
BUILDING STANDARD NEW 2' X 4' FLUORESCENT. VERIFY
NO SUBSTITUTIONS
NEW 2' X 4' FLUORESCENT - FOCAL POINT - FLU24B2T8E120GPS -
BREAK ROOM SYMBOLS LEGEND
BREAK ROOM REFLECTED CEILING PLAN KEYED NOTES
S SINGLE POLE LIGHT SWITCH
17/A6.10 FOR SECTION AT FURR DOWN
INDICATED ON PLAN. REFER TO MILLWORK ELEVATIONS FOR DETAILS. REFER TO
CONTRACTOR TO PROVIDE AND INSTALL GYP BOARD FURR DOWNS WHERE
INDICATED ON PLAN.
FIRE PANEL TIE-IN. PROVIDE 20 AMP CIRCUIT FOR CARD ACCESS WHERE
PROVIDE FIRE-RATED J-BOX ABOVE CEILING FOR CARD ACCESS BUILDING
MILLICHAP FOR APPROVAL.
ROOM. CONTRACTOR TO SUBMIT CUT SHEET TO STAFFELBACH/MARCUS &
THERMOSTATICALLY CONTROLLED EXHAUST FAN IN TENANT SERVER
CONTRACTOR TO PROVIDE AND INSTALL CEILING MOUNTED
REFER TO 15/A1.41 FOR KEYED NOTESREFER TO 20/A1.41 FOR KEYED NOTES
REFER TO 10/A1.41 FOR KEYED NOTES REFER TO 05/A1.41 FOR KEYED NOTES
A1
A2
A3
A4
A5
FROM OTHER FIXTURES
LIGHT FIXTURES IN FRONT OF PROJECTOR TO BE SWITCHED SEPARATELY
B1
C1
C2
D1
PLAN.
POINTS AS INDICATED ON PLAN. COORDINATE LOCATIONS WITH CABLING
CONTRACTOR TO PROVIDE DATA OUTLET FOR TENANT WIRELESS ACCESS
A1
A2
A3
A4
A5
A5
A5
ARMSTRONG: ULTIMA
ON PLAN. SPECIFICATION:
AND UPGRADED CEILING TILE IN LARGE CONFERENCE ROOM AS INDICATED
CONTRACTOR TO PROVIDE AND INSTALL NEW BUILDING STANDARD GRID
ARMSTRONG: ULTIMA
ON PLAN. SPECIFICATION:
AND UPGRADED CEILING TILE IN LARGE CONFERENCE ROOM AS INDICATED
CONTRACTOR TO PROVIDE AND INSTALL NEW BUILDING STANDARD GRID
B1
1'
-
6
"
EQUALEQUAL
8"4'-0"
C1
C2
D1
D1
D1
D1 D1
2
'
-
3
"
3
'
-
0
"
2'-3"
2'-2‚"
2
'
-
3
"
E
Q
U
A
L
E
Q
U
A
L
ALT#1
TYPICAL
THROUGHOUT
LIMIT OF
RECEPTION
TYPICAL
THROUGHOUT
LIMIT OF
CONFERENCE
ROOM
EQEQ
1
7
/
A
6
.
10
17
/
A
6
.
1
0
DIMMABLE FIXTURE - FLU 22 B 2 T8 D 120 G PS
FOCAL POINT - LUNA 2X2 - WITH PERFORATED SHEILDING
DIMMABLE FIXTURE - FLU 22 B 2 T8 D 120 G PS
FOCAL POINT - LUNA 2X2 - WITH PERFORATED SHEILDING
D
S
D
D
D
3
EE EE
C1 C1 C1
C1C1C1
E
E
9'-0"
3S
E
E
E
LIM
IT
O
F
W
O
R
K
B1 B1
B1B1
C1 C1
C1C1
C1C1
D
S
DD
S
9'-0"
C1C1
B
S
B1
B
B B
B
S
S
9'-0"
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
7
:
0
0
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
_
5
0
fin
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
OFFICEOFFICEOFFICERM OFFICE
OFFICE OFFICE OFFICEBREAK/COPY STORAGE
OFFICE
SERVER RECEPTION
COAT
CONFERENCE
SMALL
OFFICEOFFICE
CONFERENCE
LARGE
514 515 516 517 518
501 500
513 512 511 510 509 508 507 503
502
505 504
STOR.
FEC
OFFICE
OPEN
506
OFFICE
OPEN
519
FEC
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
R
K
„" = 1'-0" „" = 1'-0" „" = 1'-0"
FINISH PLAN
FINISH PLAN
CONTRACTOR SHALL FLASH PATCH ROUGH OR CRACKED AREAS TO PROVIDE A SMOOTH AND EVEN FLOOR
KEYED NOTES
1.
2.
5.
6.
GENERAL NOTES
CONCRETE SLAB IS NOT TO EXCEED 1/4" SLOPE PER EVERY 10'-0" UNDER ALL MILLWORK. PROVIDE
FLOOR FILL AS REQUIRED.
"FURNISHED BY LANDLORD". COORDINATE WITH BUILDING MANAGEMENT.
CONTRACTOR TO VERIFY AVAILABILITY/QUANTITIES OF BUILDING STOCK FOR ALL MATERIALS NOTED AS
ALL EXISTING BASE BUILDING WALLS, LOBBIES AND FLOORING TO BE PATCHED/REPAIRED TO MATCH
PRIOR TO INSTALLATION OF SCHEDULE FLOORING MATERIALS. REMOVE ALL OBSTRUCTIONS. CONTRACTOR
4.
A1.50
3.CONTRACTOR TO INSTALL CARPET PRIOR TO INSTALLATION OF MILLWORK CABINETS AND PEDESTALS.
TO FURNISH AND INSTALL "LEE'S CERTIFIED CARPET GLUE" - U2 UNIBOND
AND CLEAN.
CONTRACTOR TO ENSURE THAT BUILDING STANDARD EXTERIOR WINDOW BLINDS ARE IN PLACE, OPERABLE 7.
CARPETING. CARPET BASE TO BE INSTALLED WITH 2 ROWS OF 1" STAPLES.
PROVIDE INSTALLATION AND ADHESIVE FOR FOOTAGE FOR CARPET AND CARPET BASE. CONTRACTOR TO
MARCUS & MILLICHAP. G.C. TO PROVIDE REQUIREMENTS FOR CARPET YARDAGE AND LINEAR SQUARE
ALL CARPET AND CARPET BASE TO BE PROVIDED BY TENANT. G.C. TO SUBMIT SEAMING DIAGRAM TO
REFER TO SPECIFICATIONS SHEET A0.01 FOR ADDITIONAL NOTES.8.
FINISH SPECIFICATIONS
B02
W03 WALL FINISH
SYMBOL SHOWN
IN USE.
"X" DESIGNATES MULTIPLE FINISHES.
REFER TO ELEVATIONS FOR SPECIFIC
LOCATIONS.
WALL FINISH
BASE FINISH
CEILING FINISH, CEILING HEIGHT
WALL FINISH
BASE FINISH
FLOOR FINISH
CEILING FINISH, CEILING HEIGHT
WALL FINISH
BASE FINISH
FLOOR FINISH
WALL FINISH SYMBOL
ROOM FINISH INDICATOR
FOR GENERAL ROOM FINISHES
ROOM FINISH INDICATOR
FOR GENERAL ROOM FINISHES (VERTICAL CONFIGURATION)
SYMBOLS LEGEND
(HORIZONTAL CONFIGURATION)
F01B02 W03 C04
B02
W01
B03
F04
W02
C01
07
3" = 1'-0"
„"
STONE TO CARPET
DETAIL @ DIVIDER STRIP 3" = 1'-0"04 STONE BASE
SECTION DETAIL
FINISHED
MATCHING AND SMOOTH
NOTE: BASE TOPS TO BE
0305‚ = 1'-0"
4
"
9.
N.T.S.
AND ( 1) ONE COAT AFTER INSTALLATION.
CONTRACTOR TO APPLY ONE (1) COAT OF PAINT PRIOR TO CARPET INSTALLATION
COMPOSITION TILE. TRANSITION TO OCCUR CENTERLINE OF THE DOOR.
CONTRACTOR TO PROVIDE AND INSTALL RUBBER TRANSITION STRIPS (TS02) AT CARPET TO VINYL
04/A1.50.
PROVIDE AND INSTALL ZINC TRANSITION STRIP (TS01) AT ALL CARPET TO STONE TRANSITIONS, REFER PLAN FOR LOCATION.
REQUIRED. REFER TO
ANCHOR TO FLOOR AS
„" ZINC DIVIDER STRIP.
PLAN FOR LOCATION.
REQUIRED. REFER TO
ANCHOR TO FLOOR AS
„" ZINC DIVIDER STRIP.
EXISTING IN AREAS AFFECTED BY CONSTRUCTION.
01
02
03
04
LIKE NEW CONDITIONS. TYP.
EXISTING TILE TO OTHER AREAS OF SUITE TO REPLACE OLD, STAINED, OR DAMAGED TILE TO CREATE
G.C. TO PURCHASE AND INSTALL NEW CEILING TILE AS SPECIFIED FOR ROOMS INDICATED. RELOCATE
EXTEND FLOOR AND WALL FINISHES BELOW AND BEHIND CABINETRY.
05 PAINT FURRDOWNS AT MILLWORK W01 TO MATCH WALLS
floor 5
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C01
B01
F01
W01
C02
B01
F01
W01
C02B03
F05
W01
C01
B03
F05
W01
C01
B03
F05
W01
C01
B02
F02
W01
C02
F03
F04
B01
F01
W01
C01
CARPET AS SPECIFIED
DIVIDER STRIP.
STONE TILE AND ZINC
OF CARPET WITH EDGE OF
TRANSITION TO ALIGN EDGE
PROVIDE FLOOR FILL
OVER MEMBRANE.
THIN SET STONE TILE
CARPET.
DIVIDER STRIP.
STONE TILE AND ZINC
OF CARPET WITH EDGE OF
TRANSITION TO ALIGN EDGE
PROVIDE FLOOR FILL
SILICONE BEAD
FINISH CORNER WITH WHITE
PARTITION AS SCHEDULED
SMOOTH FINISH TOPS.
ADJACENT BASE TILES WITH
STONE BASE TOPS TO MATCH
1/8" CHAMFER
PAINT AS SCHEDULED
B02
F02
W01
C02
F04
F03
B03
F05
W01
C01
B01
F01
W01
C02
TS01
TS01
TS01
TS01
TS01 TS01
TS01
TS01
TS01
TS01
TS01
TS01 TS01
TS02
W02
W02
01
02
02 02
02
02
02
03
03
04
04
04
05
E
Q
.
E
Q
.
B01
F01
W01
C01
500 RECEPTION
ENLARGED FLOOR PATTERN
W02
W02
05/A1.50
W
0
2
W
0
2
TS02
01
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
7
:
0
3
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
_
5
1
s
e
a
m
in
g
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
10 floor 5
" = 1'-0"8
1
NORTH
PLAN
OFFICEOFFICEOFFICERM OFFICE
OFFICE OFFICE OFFICEBREAK/COPY STORAGE
OFFICE
SERVER RECEPTION
COAT
CONFERENCE
SMALL
OFFICEOFFICE
CONFERENCE
LARGE
514 515 516 517 518
501 500
513 512 511 510 509 508 507 503
502
505 504
STOR.
OFFICE
OPEN
506
OFFICE
OPEN
519
0 4 8 16 32
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
RK
KEYED NOTES
1.
GENERAL NOTES
A1.51
CARPETING. CARPET BASE TO BE INSTALLED WITH 2 ROWS OF 1" STAPLES.
PROVIDE INSTALLATION AND ADHESIVE FOR FOOTAGE FOR CARPET AND CARPET BASE. CONTRACTOR TO
MARCUS & MILLICHAP. G.C. TO PROVIDE REQUIREMENTS FOR CARPET YARDAGE AND LINEAR SQUARE
ALL CARPET AND CARPET BASE TO BE PROVIDED BY TENANT. G.C. TO SUBMIT SEAMING DIAGRAM TO
FINISH SPECIFICATIONS
B02
W03 WALL FINISH
SYMBOL SHOWN
IN USE.
"X" DESIGNATES MULTIPLE FINISHES.
REFER TO ELEVATIONS FOR SPECIFIC
LOCATIONS.
WALL FINISH
BASE FINISH
CEILING FINISH, CEILING HEIGHT
WALL FINISH
BASE FINISH
FLOOR FINISH
CEILING FINISH, CEILING HEIGHT
WALL FINISH
BASE FINISH
FLOOR FINISH
WALL FINISH SYMBOL
ROOM FINISH INDICATOR
FOR GENERAL ROOM FINISHES
ROOM FINISH INDICATOR
FOR GENERAL ROOM FINISHES (VERTICAL CONFIGURATION)
SYMBOLS LEGEND
(HORIZONTAL CONFIGURATION)
F01B02 W03C04
B02
W01
B03
F04
W02
C01
01
PLAN
CARPET SEAMING
CARPET SEAMING DIAGRAM
SHADED AREA INDICATES FINISH OTHER THAN CARPET (F01) - REFER A1.50.
LEGEND
2.
KICK-OFF MEETING.
CONTRACTOR TO PROVIDE MARCUS & MILLICHAP WITH CARPET DELIVERY ADDRESS AT CONSTRUCTION
THEIR OWN SEAMING PLAN TO MARCUS & MILLICHAP FOR REVIEW AND APPROVAL.
THIS SEAMING PLAN IS FOR GENERAL REFERENCE ONLY. CONTRACTOR TO PROVIDE
DIRECTION
PATTERN
01
D
IR
E
C
T
IO
N
P
A
T
T
E
R
N
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
7
:
0
9
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
1
_
6
0
fu
r
n
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
10 floor 5
" = 1'-0"8
1
NORTH
PLAN
OFFICEOFFICEOFFICERM OFFICE
OFFICE OFFICE OFFICEBREAK/COPY STORAGE
OFFICE
SERVER RECEPTION
COAT
CONFERENCE
SMALL
OFFICEOFFICE
CONFERENCE
LARGE
514 515 516 517 518
501 500
513 512 511 510 509 508 507 503
502
505 504
STOR.
FEC
OFFICE
OPEN
506
OFFICE
OPEN
519
FEC
0 4 8 16 32
OM
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
RK
•" = 1'-0"
06 (WD01)
PANEL
VENER END
WOOD
FURNITURE GENERAL NOTES
A1.60
PLAN
FURNITURE
1.FURNITURE BY OTHERS, FOR REFERENCE ONLY.
2.FURNITURE NUMBERING FOR REFERENCE ONLY.
FURNITURE PLAN
TRANSACTION TOP @ 34" AFF
WOOD VENEER ADA
3'-2"
1'
-
0
"
8
'
-
0
"
8'-6"8"
PROVIDED BY FURNITURE VENDOR
ADA COMPLIANT RECEPTION DESK
WILL NOT BE ATTACHED TO FINISHED FLOOR.
DELIVER AND ASSEMBLE ON SITE. DESK
ONLY. TENANT FURNITURE VENDOR TO
RECEPTION DESK SHOWN FOR REFERENCE
0204•" = 1'-0"CONFERENCE ROOM/TABLE DIMENSIONS
01
03
02040506070809
10111213141516
181920
17
DOOR HARDWARE AND FRAME DETAILS
REFER TO A6.11 FOR DOOR,
8
"
8"1'-8"8"8"1'-8"8"
REFER DOOR SCHEDULE
1•"1•"
05 REFER ALTERNATE #3
ELEVATION AT RECEPTION (DOOR 500) •" = 1'-0"
R
E
F
E
R
T
O
D
O
O
R
S
C
H
E
D
U
L
E
10 •" = 1'-0"
CL
3
'
-
3
"
(
4
8
"
M
A
X
)
8
"
8"1'-8"8"
1•
"
R
E
F
E
R
T
O
D
O
O
R
S
C
H
E
D
U
L
E
1•
"
1•"
REFER PLAN
1•"
…" CLEAR TEMPERED GLASS
„" CLEAR SILICONE BUTT JOINT
12
/
A
6
.
10
11A/A6.10
DOOR HARDWARE AND FRAME DETAILS
REFER TO A6.11 FOR DOOR,
1•"@ 3'-0" MAX PER PANEL
EQUAL GLASS PANELS
WOOD/GLASS DOOR AT SMALL CONFERENCE (DOOR 501)
ALTERNATE #8
REFER DOOR SCHEDULE
R
E
F
E
R
T
O
D
O
O
R
S
C
H
E
D
U
L
E
•" = 1'-0"
EQUAL •"EQUAL •"EQUAL
3 •"3 •"RECEPTION DESK
W02
CEILING
C02
PROVIDED AND INSTALLED
BY TENANT VENDOR
W01
REFER TO ALT#1/A0.00
ALT GYP BD. CEILING
1•
"
1'
-
9
"
1•
"
EQ EQ
„" CLEAR SILICONE BUTT JOINT
SIDELITE, REFER TO A6.11
BY OTHERS
12
FOR DOOR TYPE
REFER ALTERNATE #6
12
/
A
6
.
10
11A/A6.10
DOOR HARDWARE AND FRAME DETAILS
REFER TO A6.11 FOR DOOR,
3
'
-
3
"
(
4
8
"
M
A
X
)
CL
REFER TO ALT#6/A0.00
…" CLEAR TEMPERED GLASS CLERESTORY
CL
3
'
-
3
"
(
4
8
"
M
A
X
)
8
"
8"1'-8"8"
16 •" = 1'-0"
1•
"
R
E
F
E
R
T
O
D
O
O
R
S
C
H
E
D
U
L
E
1•
"
‚" CLEAR TEMPERED GLASS
1•"
1'-7•"
1•"
11A/A6.10
12
/
A
6
.
10
DOOR HARDWARE AND FRAME DETAILS
REFER TO A6.11 FOR DOOR,
1•"
AT RECEPTION TO BACK OFFICE (DOOR 506)
ALTERNATE #7 - WOOD/GLASS DOOR
REFER ALTERNATE #5 AND 6
ELEVATION AT CONFERENCE (DOOR 503)
STRUCTURE AS REQUIRED.
PROVIDE IN WALL SUPPORT
8'-0"
@ 3'-0" MAX PER PANEL
EQUAL GLASS PANELS
1•"
REFER DOOR SCHEDULE
1•"
REFER PLAN
11A/A6.10
12
/
A
6
.
10
REFER DOOR SCHEDULE
R
E
F
E
R
T
O
D
O
O
R
S
C
H
E
D
U
L
E
1•
"
R
E
F
E
R
T
O
D
O
O
R
S
C
H
E
D
U
L
E
1•
"
ALT #5 ALT #6
B1
B1
C1 C1
C1C1
C1C1
DD
S
C1C1C1
9'-0"
9'-0"
C1
E
FEATURE CEILING IN RECEPTION
ALTERNATE #1 •" = 1'-0"02
C
DD
D D
18/A6.10
9'-0"
18
/
A
6
.
10
W01
GYP. CEILING
PAINT TO
MATCH
1'
-
3
•
"
4
'
-
0
"
1'
-
4
"
1'
-
6
"
D
2'-0"4'-0"2'-0"
ALT#2
ALT#3
ALT#4
ALT#5
ALT#1
ALT#6
CEILING AND LIGHTING AT RECEPTION AS INDICATED ON 02/A2.10
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING FOR GYP BOARD
ALL PLAN SHEETS FOR ALTERNATE LOCATIONS**
**GENERAL CONTRACTOR TO REFER TO SHEET A2.10 FOR ALTERNATE DETAILS, REFER TO
ALT#7
ALT#8
#501). REFER TO 10/A2.10
INSTALL WOOD AND GLASS DOOR ENTRANCE TO SMALL CONFERENCE ROOM (DOOR
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND
(DOOR #506). REFER TO 16/A2.10
INSTALL WOOD AND GLASS DOOR AT DOOR BETWEEN RECEPTION AND OPEN OFFICE
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND
REFER 12/A2.10. INCLUDE ALTERNATE HARDWARE SHOWN ON 08/A2.10
COMPLETE WOOD AND GLASS DOOR(S) AT LARGE CONFERENCE ROOM (DOOR #503).
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND INSTALL
REFER TO 05/A2.10. INCLUDE ALTERNATE HARDWARE SHOWN ON 08/A2.10
COMPLETE WOOD AND GLASS DOOR(S) AT TENANT MAIN ENTRY / RECEPTION (DOOR #500).
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND INSTALL
NOT USED
NOT USED
INSTALL CLEARSTORY WINDOW AS INDICATED ON 12/A2.10 (FOR ALT #5 ONLY)
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND
ALTERNATES LIST
08 FOR ALTERNATES
DOOR SCHEDULE AND HARDWARE
1
0
:
1
7
:
1
6
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
2
_
1
0
_
a
lt
e
r
n
a
t
e
s
.
d
g
n
1314
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
7
:
1
6
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
2
_
1
0
_
a
lt
e
r
n
a
t
e
s
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
A2.10
ALTERNATES
10
"
HARDWARE
SET FOR
HARDWARE
REFER TO
HARDWARE
SET FOR
HARDWARE
REFER TO
10
"
HARDWARE
SET FOR
HARDWARE
REFER TO
HARDWARE
SET FOR
HARDWARE
REFER TO
10
"
2 EQ SPACES
W01
1•"2'-6„"
ƒ"
1•"
1'-7„"
ƒ"
3
'
-
0
"
1'
-
10
"
4
"
2
'
-
10
"
PL02
W01
PL01
PL02
CABINETS
CLAD UPPER
PLASTIC LAMINATE
CABINETS
CLAD LOWER
PLASTIC LAMINATE
SCHEDULED
BASE AS
B03
H-1
TYP.
14
/
A
4
.
10
13
/
A
4
.
10
4" BACKSPLASH
COUNTERTOP AND
PLASTIC LAMINATE
TO MATCH WALL
SOFFIT FINISHED
GYPSUM BOARD
19/A4.10
19/A4.10
16A/A4.10
16A/A4.10
•" = 1'-0"01 ELEVATION @ BREAK/WORK ROOM #51403 •" = 1'-0"
H-1
TYP.
W01 RF-1
AR-1
GD-1
SK-1
FC-1
12
/
A
4
.
10
WH-1 NEMA 5-20 R
PL02
W01
PL01
PL02
CABINETS
CLAD UPPER
PLASTIC LAMINATE
CABINETS
CLAD LOWER
PLASTIC LAMINATE
4" BACKSPLASH
COUNTERTOP AND
PLASTIC LAMINATE
TO MATCH WALL
SOFFIT FINISHED
GYPSUM BOARD
3
'
-
0
"
1'
-
10
"
4
"
2
'
-
10
"
2
'
-
3
„
"
5
'
-
8
‡
"
M
A
N
U
F
A
C
T
U
R
E
R
V
E
R
IF
Y
W
IT
H
MAKER
TENANT COFFEE
WATER LINE FOR
REFRIGERATOR
TENANT
WATER LINE FOR
CM-1
MW-1
DW-1
1'
-
7
"
0
8
/
A
4
.
10
0
9
/
A
4
.
10
ƒ"
3'-0"
ƒ"
2'-6‡"3'-0"
ƒ"
2'-1•"
ƒ"
2'-10†"
1•"2 EQUAL SPACESHOLDHOLD2 EQ SPACES
ƒ"
3'-0"
ƒ"
11'-7•" - 8 EQ SPACES
1•"
ELEVATION @ BREAK/WORK ROOM #51404 •" = 1'-0"
NEMA 5-20 R
3
'
-
0
"
5
'
-
0
"
PL02
W01
CABINETS
UPPER
LAMINATE CLAD
PLASTIC
WALL
TO MATCH
SOFFIT FINISHED
GYPSUM BOARD
ELEVATION @ BREAK/WORK ROOM #514
SCHEDULED
BASE AS
B03
SCHEDULED
BASE AS
B03
14
/
A
4
.
10
10
/
A
4
.
10
13
/
A
4
.
10
13
/
A
4
.
10
13
/
A
4
.
10
19/A4.10
19/A4.10
19/A4.10
17/A4.1017/A4.10 16D/A4.10
H-1
TYP.
16D/A4.10
1•"
9'-2‡" - 6 EQUAL SPACES1•"1•"
6'-3•" - 4 EQ SPACES
SCREWS ONLY
FLAT HEAD
COUNTERSUNK
USE
AS SPECIFIED.
4" WIRE PULL
HEAD SCREWS ONLY
COUNTERSUNK FLAT
SPECIFIED. USE
4" WIRE PULL AS
HEAD SCREWS ONLY
COUNTERSUNK FLAT
SPECIFIED. USE
4" WIRE PULL AS
SCHEDULED
BASE AS
B03
20/A4.10 20/A4.10
•" = 1'-0"07 ELEVATION @ BREAK/WORK ROOM #514
3
'
-
0
"
1'
-
10
"
4
"
2
'
-
10
"
PL02
W01
PL01
PL02
CABINETS
CLAD UPPER
PLASTIC LAMINATE
4" BACKSPLASH
COUNTERTOP AND
PLASTIC LAMINATE
TO MATCH WALL
SOFFIT FINISHED
GYPSUM BOARD
CABINETS/DRAWERS
CLAD LOWER
PLASTIC LAMINATE
16D/A4.10
19/A4.10
19/A4.10
13
/
A
4
.
10
14
/
A
4
.
10
H-1
TYP.
H-1
TYP.
SCHEDULED
BASE AS
B03
16D/A4.10
0
8
/
A
4
.
10
1•"17'-11‡" - 12 EQ SPACES
1•"
HEAD SCREWS ONLY
USE COUNTERSUNK FLAT
4" WIRE PULL AS SPECIFIED.
1•"
17'-‡" - 13 EQ SPACES1•"
AS INDICATED ON A4.10
PROVIDE COPPER WATER LINE WITH SHUT-OFF VALVE
TENANT SUPPLIED COFFEE MAKER.
MODEL/DESCRIPTION:
MANUFACTURER:
NOTE:
MODEL:
MANUFACTURER:
SPECIFY THIS AERATOR WHEN ORDERING F-1.
RP19754 (FINISH TO MATCH F-1)
DELTA
91M2650; PARTIAL OVERLAY/TWIN OVERLAY AS APPLICABLE
BLUM
NOTE:
INDICATED ON A4.10
PROVIDE COPPER WATER LINE WITH SHUT OFF VALVE AS
TOP
G.C. TO ENSURE 1" CLEAR ON EACH SIDE AND 1 „" CLEAR ON
GSHS6KGZSS, STAINLESS STEEL, 69 •" H X 35" D X 35 ƒ" W
GE (GENERAL ELECTRIC) ENERGY STAR
TO BE MOUNTED UNDER COUNTER
INSTA-HOT OR EQUAL REFER TO MEP
NOTE:
MANUFACTURER:
NOTE:
NOTE:
MODEL/SIZE:
MANUFACTURER:
FINISH:
SIZE:
MODEL
MANUFACTURER:
STAINLESS STEEL
12 9/32" (D) X 11 3/16" (H) X 23 25/23" (W)
PEM31SMSS
GE COUNTER TOP MICROWAVE OVEN
11 …" HIGH, 6" DIAMETER
BADGER ONE ( 1/3 HORSEPOWER)
IN-SINK-ERATOR
SIZE:
MODEL:
MANUFACTURER:
FINISH:
MODEL/DESCRIPTION:
MANUFACTURER:
CHROME FINISH
441-DST - 2 HOLE APPLICATION
DELTA - COLLINS SERIES
STAINLESS STEEL
32 11/32"H X 24"D X 25‚"W
GLDT696DSS
GE (GENERAL ELECTRIC) ENERGY STAR
FINISH:
SIZE:
MODEL:
MANUFACTURER:
FINISH:
SIZE:
MODEL:
MANUFACTURER:
STAINLESS STEEL
25"L x 21 ‚"W x 5 …"D INSIDE BOWL
#GECR2521 (MR2)
ELKAY - SINGLE BOWL
WH-1: WATER HEATER:
SK-1: SINK:
RF-1: REFRIGERATOR:
MW-1: MICROWAVE:
H-1: CABINET HINGES:
GD-1: GARBAGE DISPOSAL:
AR-1: AERATOR - 1.5 GPM:
FC-1: FAUCET:
DW-1: DISHWASHER:
CM-1: COFFEE MAKER:
CP-1: CABINET PULLS
NOTE:
FINISH:
MODEL:
MANUFACTURER:
USE COUNTERSUNK FLAT HEAD SCREWS
CHROME
LIB-23909
LIBERTY
BREAK/COPY NOTES
1 CONTRACTOR TO SUBMIT APPLIANCE CUT SHEETS PRIOR TO MILLWORK SUBMITTALS.
2 CONTRACTOR TO USE DRAWER GLIDES AS INDICATED ON A0.02
3
MILLWORK SHOP DRAWINGS.
CONTRACTOR TO REFER TO APPLIANCE SUBMITTAL FOR OPENING SIZES, COORDINATE WITH
APPLIANCE SPECIFICATIONS
3
'
-
0
"
1•
"
„
"
2
"
ƒ
"
ƒ"ƒ"
ƒ
"
ƒ"ƒ"
EXTERIOR
CABINET
P-LAM CLAD
STYLE
P-LAM CLAD
INTERIOR
MELAMINE CABINET
„"
EXTERIOR
CABINET
P-LAM CLAD
INTERIOR
MELAMINE CABINET
„"ƒ"
ENDPANEL
P-LAM CLAD
INTERIOR
CABINET
MELAMINE
DETAIL
MILLWORK
SCALE
HALF
16ADETAIL
ENDPANEL
SCALE
HALF
PARTITION AS
SCHEDULED
P-LAM CLAD
EDGE
P-LAM CLAD
CABINET
EXTERIOR
APPLIANCE
- VERIFY
DIMENSION
SCRIBE MILLWORK
TO WALL
DETAIL
MILLWORK
SCALE
HALF16B
FACE OF TOE
KICK BELOW
SHOWN DASHED
FACE OF TOE
KICK BELOW
SHOWN DASHED
SCRIBE MILLWORK
TO WALL
PARTITION AS SCHEDULED
DETAIL
MILLWORK
SCALE
HALF 16C16D
@ APPLIANCE
MILLWORK DETAIL HALF SCALE20SCALE
"4
3
"8
3
"8
3
"
4
3
9
ƒ
"
19 @ CORNER
MILLWORK DETAIL HALF SCALE
INTERIOR
CABINET
MELAMINE
1•"
„"
„
"1•
"
INTERIOR
CABINET
MELAMINE
EXTERIOR
CABINET
P-LAM CLAD
P-LAM CLAD
EDGE
P-LAM CLAD CABINET
EXTERIOR
MELAMINE CABINET
INTERIOR
APPLIANCE
- VERIFY
DIMENSION
P-LAM CLAD CABINET
EXTERIOR
ABOVE SHOWN DOTTED
FACE OF COUNTERTOP
BELOW SHOWN DASHED
FACE OF TOE KICK
17 @ TOWER
MILLWORK DETAIL HALF SCALE
EXTERIOR
P-LAM CLAD CABINET
INTERIOR
MELAMINE CABINET
EDGE
P-LAM CLAD
BELOW
COUNTERTOP
EXTERIOR
P-LAM CLAD CABINET
INTERIOR
CABINET
MELAMINE
BELOW SHOWN DASHED
FACE OF TOE KICK
…"…"ƒ"
„"
18 @ UPPER CABINET
MILLWORK DETAIL HALF SCALE
INTERIOR
CABINET
MELAMINE
SURFACES
ALL EXPOSED
P-LAM CLAD
WOOD BLOCKING -
CABINET EXTERIOR
P-LAM CLAD
ELEVATION
OCCORS. REFER
BEYOND WHERE
P-LAM CLAD PANEL
TO FURRDOWN
SCRIBE MILLWORK
FURRDOWN
GYPSUM BOARD
2"
1" = 1'-0"
PLASTIC LAMINATE CLAD
BACKSPLASH
SECTION @ BREAK ROOM MILLWORK
SECTION @ BREAK ROOM MILLWORK
PLASTIC LAMINATE CLAD
CABINET FRONTS AND
WHITE MELAMINE CLAD
INTERIOR
2'-1"
1'-7"
3"
3/4" WHITE MELAMINE CLAD
PLASTIC LAMINATE CLAD
CABINET FRONTS AND
WHITE MELAMINE CLAD
INTERIOR
BASE AS SCHEDULED
BACKSPLASH
2'-1"
PLASTIC LAMINATE CLAD
COUNTER TOP AND
BACKSPLASH
PLASTIC LAMINATE CLAD
WHITE MELAMINE CLAD
INTERIOR AND DRAWERS
BASE AS SCHEDULED
E
Q
.
E
Q
.
E
Q
.
E
Q
.
E
Q
.
SCALE
WATER HEATER
DASHED NO SHELVES AT
WATER HEATER SHOWN
BLUM SERIES DRAWER
GLIDES (DG-1)
NOTE: BLUM 230E SERIES
DRAWER GLIDES (DG-1)
TO BE USED ON
BREAKROOM DRAWERS
(OMIT AT WATER HEATER)
ADJUSTABLE SHELVES
PANEL BEYOND
LINE OF PLASTIC LAMINATE
2
'
-
2
"
2
'
-
10
"
4" WIRE PULLS AS SPECIFIED
1" = 1'-0"
SCALE
1" = 1'-0"
SCALE
1" = 1'-0"
SCALE
1" = 1'-0"
SCALE
2
'
-
2
"
2
'
-
10
"
2
'
-
2
"
2
'
-
10
"
2'-1"
SECTION @ UPPER CABINET
SECTION @ MILLWORK DRAWERS
SECTION @ LOWER CABINET
4" WIRE PULLS AS SPECIFIED
CLAD COUNTER TOP
PLASTIC LAMINATE
COUNTER TOP AND
4
"
4
"
4
"
BY TENANT VENDOR.
MAKER TO BE SUPPLIED
WATER LINE FOR COFFEE
DOORS AS SPECIFIED
DOORS FINISED AS SPECIFIED
DRAWER FRONTS AS SPECIFIED
08
10
1213
PLASTIC LAMINATE CLAD
CABINET FRONTS AND
WHITE MELAMINE CLAD
INTERIOR AND 3/4"
ADJUSTABLE SHELVES
2'-1‚"
EXISTING REFRIGERATOR
TO ENSURE REFRIGERATOR
HEIGHT CLEARANCE
PLUS 3"
NOTE: IN THE EVENT THAT AN
IS USED, CONTRACTOR
VENT
PANEL BEYOND
LINE OF PLASTIC LAMINATE
RF-1
3
/
4
"
2"
WB-1
WB-1
FOR ICE MAKER
WATER LINE
C
O
N
T
R
A
C
T
O
R
T
O
E
N
S
U
R
E
1"
C
L
E
A
R
F
R
O
M
T
O
P
O
F
R
F
-
1
DOORS AS SPECIFIED
3
/
4
"
1'-4ƒ"
1'-3"R
E
F
E
R
E
L
E
V
A
T
IO
N
CLEAR
3
"
NOTE:
1.
CLAD INTERIORS
WHITE MELAMINE
CABINET FRONTS AND DOORS
PLASTIC LAMINATE CLAD
0
ƒ
"
FIXTURES AND MILLWORK
SUPPORT IN WALL FOR WALL MOUNTED
CONTRACTOR TO INSTALL BLOCKING
2
"3
"
ADJUSTABLE SHELVES
ƒ" WHITE MELAMINE CLAD
BLOCKING-PAINT
TO MATCH
2
"
„
"
R
E
F
E
L
E
V
.
PLAM
INTERIOR
MELAMINE
INTERIOR
RCP
REF
EXPOSED SURFACES
P-LAM CLAD ALL
WOOD BLOCKING -
TO FINISHED CEILING
SCRIBE MILLWORK
FINISHED CEILING
PAINT AS SCHEDULED
PAINT AS SCHEDULED
PAINT AS SCHEDULED
PAINT AS SCHEDULED
16C/A4.10
16C/A4.10
1
0
:
1
7
:
2
1
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
4
_
1
0
_
b
r
e
a
k
_
n
e
w
.
d
g
n
1" = 1'-0"
SCALE09
1•
"
2'-1"
MW-1
DW-1
1
•
"
MATCH
PAINT TO
BLOCKING
2
'
-
10
"
PLASTIC LAMINATE CLAD
COUNTER TOP AND
BACKSPLASH
SECTION @ DISHWASHER
14
R
E
F
E
R
T
O
E
L
E
V
A
T
IO
N
V
E
R
IF
Y
W
IT
H
M
F
G
PULL AS SPECIFIED [CP-1]
PULL AS SPECIFIED [CP-1]
PULL AS SPECIFIED [CP-1]
PULL AS SPECIFIED [CP-1]
PULL AS SPECIFIED [CP-1]
PULL AS SPECIFIED [CP-1]
BRACE BEYOND
MELAMINE COVERED PLYWOOD
ALCOVE BELOW SINK
CONTINUE FLOOR FINISHES INTO
[GD-1]
18/A4.10
1•
"
„
"
2
"
ƒ
"
ƒ"ƒ"
ƒ
"
ƒ"ƒ"
EXTERIOR
CABINET
P-LAM CLAD
STYLE
P-LAM CLAD
INTERIOR
MELAMINE CABINET
„"
EXTERIOR
CABINET
P-LAM CLAD
INTERIOR
MELAMINE CABINET
„"ƒ"
ENDPANEL
P-LAM CLAD
INTERIOR
CABINET
MELAMINE
DETAIL
MILLWORK
SCALE
HALF
16ADETAIL
ENDPANEL
SCALE
HALF
PARTITION AS
SCHEDULED
P-LAM CLAD
EDGE
P-LAM CLAD
CABINET
EXTERIOR
APPLIANCE
- VERIFY
DIMENSION
SCRIBE MILLWORK
TO WALL
DETAIL
MILLWORK
SCALE
HALF16B
FACE OF TOE
KICK BELOW
SHOWN DASHED
FACE OF TOE
KICK BELOW
SHOWN DASHED
SCRIBE MILLWORK
TO WALL
PARTITION AS SCHEDULED
DETAIL
MILLWORK
SCALE
HALF 16C16D
@ APPLIANCE
MILLWORK DETAIL HALF SCALE20SCALE
"4
3
"8
3
"8
3
"
4
3
9
ƒ
"
19 @ CORNER
MILLWORK DETAIL HALF SCALE
INTERIOR
CABINET
MELAMINE
1•"
„"
„
"1•
"
INTERIOR
CABINET
MELAMINE
EXTERIOR
CABINET
P-LAM CLAD
P-LAM CLAD
EDGE
P-LAM CLAD CABINET
EXTERIOR
MELAMINE CABINET
INTERIOR
APPLIANCE
- VERIFY
DIMENSION
P-LAM CLAD CABINET
EXTERIOR
ABOVE SHOWN DOTTED
FACE OF COUNTERTOP
BELOW SHOWN DASHED
FACE OF TOE KICK
17 @ TOWER
MILLWORK DETAIL HALF SCALE
EXTERIOR
P-LAM CLAD CABINET
INTERIOR
MELAMINE CABINET
EDGE
P-LAM CLAD
BELOW
COUNTERTOP
EXTERIOR
P-LAM CLAD CABINET
INTERIOR
CABINET
MELAMINE
BELOW SHOWN DASHED
FACE OF TOE KICK
…"…"ƒ"
„"
18 @ UPPER CABINET
MILLWORK DETAIL HALF SCALE
INTERIOR
CABINET
MELAMINE
SURFACES
ALL EXPOSED
P-LAM CLAD
WOOD BLOCKING -
CABINET EXTERIOR
P-LAM CLAD
ELEVATION
OCCORS. REFER
BEYOND WHERE
P-LAM CLAD PANEL
TO FURRDOWN
SCRIBE MILLWORK
FURRDOWN
GYPSUM BOARD
2"
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
7
:
2
1
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
4
_
1
0
_
b
r
e
a
k
_
n
e
w
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
A4.10
DETAILS
SECTIONS &
ELEVATIONS
BREAK ROOM
09
BANQUETTE BACK WITH
WRAP-AROUND UPHOLSTERED
SIDES
6" BRUSHED STAINLESS STEEL
BASE, SURFACE APPLIED
15'-‚"
BANQUETTE SEAT WITH
WATERFALL FRONT AND
FOAM OVER COIL-SPRING
CONSTRUCTION
6
"
11•
"
1'
-
5
"
1'
-
5
•
"2
'
-
10
•
"
15'-11ƒ"
ALL LOCAL CODES AND ORDINANCES.
BE FLAME RETARDANT AS REQUIRED BY
CONSTRUCTION OF BANQUETTE ARE TO
ALL FABRICS AND FOAMS USED IN
NOTE:
ELEVATION @ BANQUETTE
10
/
A
6
.
10
16 1" = 1'-0"
3"9ƒ"2‚"
2
'
-
4
"
1"
1"
PARTITION AS SCHEDULED
OCCURS)
POSITION (WHERE DOOR
DOOR SHOWN IN CLOSED
BACK PANEL
ƒ" MDF P-LAM CLAD
3
'
-
8
"
A
.
F
.
F
.
4
'
-
0
"
M
A
X
A
.
F
.
F
.
TO EXCEED 4'-0" A.F.F.
ROD AND FLANGES NOT
LOWEST PLACEMENT OF
AS SPECIFIED
ADJUSTABLE COAT ROD FLANGES
1ˆ" O.D. COAT ROD ON
P-LAM CLAD SIDE PANEL
SEMI RECESSSED INTO ƒ" MDF
DUTY METAL CLIPS
SHELF ON BRACKETS ON HEAVY
ƒ" MDF P-LAM CLAD ADJUSTABLE
COAT AND ROD
SECTION AT
SECTION @ BANQUETTE 1" = 1'-0"
6
"
11•
"
1'
-
5
"
1'-6"
2'-3"
2
'
-
10
•
"
5"3"
1…
"
3"
ALL LOCAL CODES AND ORDINANCES.
BE FLAME RETARDANT AS REQUIRED BY
CONSTRUCTION OF BANQUETTE ARE TO
ALL FABRICS AND FOAMS USED IN
NOTE:
BANQUETTE BACK WITH
WRAP-AROUND UPHOLSTERED
SIDES
BANQUETTE SEAT WITH
WATERFALL FRONT AND
FOAM OVER COIL-SPRING
CONSTRUCTION
1"
6" BRUSHED STAINLESS STEEL
BASE, SURFACE APPLIED
1'
-
5
•
"
1ƒ
"
10
3" = 1'-0" 3" = 1'-0"
3" = 1'-0"
3" = 1'-0" 3" = 1'-0" 3" = 1'-0"
3" = 1'-0" 3"=1'-0"SHELVING BRACKET DETAIL
3" = 1'-0"SECTION AT FURR DOWN
6" MAX
1415
JAMB BEYOND
3" = 1'-0"12 HEAD DETAIL
4'-0"
EACH SIDE OF PARTITION
AT WINDOW/SIDELITE
HEAD DETAIL
SCHEDULED
PARTITION AS
CEILING AS SPECIFIED
SUSPENDED ACOUSTICAL
DOOR FRAME, RE:A6.11.
ALIGN WITH TOP OF
JAMB BEYOND
AT WINDOW/SIDELITE (FULL HEIGHT)
EVERY 4'-0" O.C.
STUD TO STRUCTURE TYPICAL
STRUCTURE ABOVE
PROVIDE BRACING TO
STRUCTURE AS REQUIRED
(STAGGER EVERY OTHER STUD)
EVERY 4'-0" O.C.
STUD TO STRUCTURE
SUSPENDED ACOUSTICAL
CEILING AS SPECIFIED
1/4" OR 3/8" CLEAR
EACH SIDE OF PARTITION
PROVIDE BRACING TO
STRUCTURE AS REQUIRED
(STAGGER EVERY OTHER STUD)
TYPICAL
STRUCTURE ABOVE
4'-0"3ƒ"
3
"
M
IN
.
1•
"
3ƒ"
1•"DOOR OPENING1•"
PARTITION AS SCHEDULED
ALUMINUM FRAMES.
AT ALL DOOR JAMBS STRIKE SIDE AT
2. PROVIDE EXTENDED LIP STRIKE PLATE
STRIKE BOX - TYPICAL.
1. MODIFY STUD TO ACCEPT STANDARD
TYPICAL ALL ALUMINUM FRAMES
NOTE:
P
L
A
N
R
E
F
E
R
SIDE
DOOR FRAME - STRIKE
ALUMINUM
V
A
R
IE
S
1'-4"
DOOR JAMB 3" = 1'-0"
DOOR FRAME - HINGE SIDE
01 STANDARD WALL
WALL TYPE- P1
SOUND CONTROL TO CEILING
WALL TYPE- P202
3ƒ"
3" = 1'-0"
3ƒ"
3" = 1'-0"
SOUND CONTROL TO DECK
WALL TYPE- P3
1 HOUR WALL
WALL TYPE- P4 0304
HEIGHT
CEILING
RCP FOR
REFER TO
HEIGHT
CEILING
RCP FOR
REFER TO
2-1/2
3-5/8
4
6
STUDS AT 16" ON CENTER
Stud Depth (in)
1-5/8
20 ga Allowable Height 25 ga Allowable Height
16'-5"
9'-8"
11'-3"
14'-4"
8'-4"
12'-10"
18'-4"15'-4"
24'-6"19'-9"
FOR RELATED DATA.
1. REFER TO SPEC. SECTION 09260- "GYPSUM BOARD SYSTEMS"
2. REFER TO FINISH PLAN FOR WALL FINISHES.
BASED ON STUD DEPTH AND GAUGE
ALLOWABLE HEIGHTS FOR GYPSUM BOARD WALLS
IN STUD SELECTION CHART.
FROM GALVANIZED STEEL WITH GAUGE AS INDICATED
3. STEEL STUDS, FLOOR AND CEILING RUNNERS FABRICATED
GENERAL NOTES
1.
COORDINATE FINAL LOCATIONS WITH ARCHITECT IN FIELD.
CONTROL JOINT SPACING SHALL NOT EXCEED MAXIMUM SPACING REQUIRED BY USG SPECIFICATIONS.
WHERE INDICATED ON PLAN AND ELEVATIONS.
PROVIDE CONTROL JOINTS FOR DRYWALL PARTITIONS AND CEILINGS
BASE AS SCHEDULED
ACOUSTICAL SEALANT
FOR SPECIFIED CEILING
SPECIFICATIONS
ONLY REFER TO
SHOWN FOR REFERENCE
TEGULAR CEILING
ACOUSTICAL SEALANT
TYPICAL
STRUCTURE ABOVE
IN ALL WALL CAVITIES
FULL BATT ACOUSTICAL INSULATION
SLIP JOINT AS REQUIRED
CHART FOR GAUGE
ALLOWABLE HEIGHTS
FRAMING- REFER TO
2 1/2" METAL STUD
BASE AS SCHEDULED
FOR SPECIFIED CEILING
SPECIFICATIONS
ONLY REFER TO
SHOWN FOR REFERENCE
TEGULAR CEILING
TYPICAL
STRUCTURE ABOVE
ALL WALL CAVITIES
BATT INSULATION IN
2 1/2" ACOUSTICAL FULL
SLIP JOINT AS REQUIRED
AT WALL AS SPECIFIED
PROVIDE EDGE TRIM
AT WALL AS SPECIFIED
PROVIDE EDGE TRIM
(1 HR. RATING) NONBEARING WALL AS OF APRIL 22, 2009
FIRE RESISTANCE RATINGS - ANSI/UL 263. DESIGN NO. U494
INSTALLATION SHALL CONFORM TO UNDERWRITERS LABORATORIES
NOTE:
ON OPP. SIDE
WITH STAGGERED JOINTS
GYP. BD. (BOTH SIDES)
5/8" FIRE-SHIELD (TYPE-X)
CHART FOR GAUGE
ALLOWABLE HEIGHTS
FRAMING- REFER TO
2 1/2" METAL STUD
(BOTH SIDES)
5/8" GYPSUM BOARD
ACOUSTICAL WALL - FLOOR TO STRUCTURE ABOVE
FIRE RATED SEALANT
FIRE RATED SEALANT
NON-LOAD BEARING
1-HOUR
3" = 1'-0" 3" = 1'-0"
3" = 1'-0"
3" = 1'-0"
APPLICABLE
WHERE
LINE OF WALL
MANUFACTURERS SPEC
STUD AS PER FRAME
FRAMING
2 1/2" METAL STUD
TO WALL.
MAXIMUM 2'-0" APART AND BOLT
STANDARDS EQUALLY SPACED AT
- REFER COVER SHEET. INSTALL
SLOT STANDARDS AS SPECIFIED
KV HEAVY-DUTY BRACKETS AND
WOOD BLOCKING AS REQUIRED
PARTITION AS SCHEDULED
BY SCREWS
PLYWOOD. SECURED TO SHELVES
SHELF. TWO LAYERS OF ƒ"
PLASTIC LAMINATE COVERED
A.F.F
STANDARD WALL - FLOOR TO CEILING
ACOUSTICAL SEALANT
BASE AS SCHEDULED
(BOTH SIDES)
" GYPSUM BOARD8
5
CHART FOR GAUGE
ALLOWABLE HEIGHTS
FRAMING- REFER TO
" METAL STUD 8
5
3
WALL
FLOAT OUT WITH
METAL EDGE TRIM
FOR SPECIFIED CEILING
SPECIFICATIONS
ONLY REFER TO
SHOWN FOR REFERENCE
TEGULAR CEILING
AS REQUIRED
BRACING
TYPICAL
STRUCTURE ABOVE
05 3" = 1'-0"
STANDARD WALL
WALL TYPE- P5
TEMPERED GLASS REFER TO
ELEVATION FOR GLASS
THICKNESS
1/4" OR 3/8" CLEAR
TEMPERED GLASS REFER TO
ELEVATION FOR GLASS
THICKNESS
(SILVER)
CLEAR ANNODIZED
FRAME FINISH IS
(SILVER)
CLEAR ANNODIZED
FRAME FINISH IS
ANNODIZED (SILVER)
FINISH TO BE CLEAR
FRAME FINISH IS FRAME
ANNODIZED (SILVER)
FINISH TO BE CLEAR
FRAME FINISH IS FRAME
17
3" = 1'-0"
TEMPERED GLASS REFER TO
ELEVATION FOR GLASS
THICKNESS
(SILVER)
CLEAR ANNODIZED
FRAME FINISH IS
4‡"
A
1.
4
0
A
N
D
A
6
.
11
R
E
F
E
R
T
O
BUTT-JOINT
„" CLEAR SILICONE
3/8" CLEAR
SECTION AT BUTT-JOINED
WINDOW/SIDELITE (FULL HEIGHT)
A.F.F
REFER PLAN
BASE AS SCHEDULED
SCHEDULED
FLOORING AS
" GYPSUM BOARD8
5
CHART FOR GAUGE
ALLOWABLE HEIGHTS
FRAMING- REFER TO
" METAL STUD 2
1
2
TYPICAL
STRUCTURE ABOVE
IN ALL WALL CAVITIES
FULL BATT ACOUSTICAL INSULATION
SLIP TRACK AS REQUIRED
MASTIC
CONT. BED OF ACOUSTIC
SET BOTTOM TRACK IN
AND STRUCTURE
MASTIC BETWEEN TRACK
CONT. ACOUSTICAL
06 3" = 1'-0"
PLUMBING CHASE WALL
WALL TYPE - P6
13
SCHEDULED
PAINT AS
11A
DOOR AS SCHEDULED
11B
SURFACES W01
PAINT ALL EXPOSED
(BOTH SIDES)
5/8" GYPSUM BOARD
SCHEDULED
CEILING AS
3" = 1'-0"
FRAMING
2 1/2" METAL STUD
18
SURFACES W01
PAINT ALL EXPOSED
(BOTH SIDES)
5/8" GYPSUM BOARD
19 3"=1'-0"
MULLION
GLAZING SYSTEM W/
EXISTING BUILDING
REQUIREMENTS
OF INSULATION
PLAN FOR EXTENT
TO CONSTRUCTION
EACH SIDE - REFER
GYPSUM BOARD
FRAMING W/ †"
2•" METAL STUD
1•
"
SHIM AS REQUIRED
EXISTING SILL
**VERIFY CONSTRUCTION
WITH BUILDING STANDARD
OR LANDLORD**
MECHANICAL FASTENERS
STICK TAPE. NO
ATTACH WITH DOUBLE
METAL FRAMING.
MATCH EXTERIOR
CAP FINISH TO
BREAK METAL END
CONNECTION
DETAIL AT PARTITION/ MULLION
CEILING AS SCHEDULED
SECTION AT ALTERNATE #1
FRAMING
2 1/2" METAL STUD
4
"
HEIGHT
AT ___
SCHEDULED
CEILING AS
AT ____ HEIGHT
SURFACES W01
PAINT ALL EXPOSED
(BOTH SIDES)
5/8" GYPSUM BOARD
SECTION AT ALTERNATE #1
HEIGHT
AT 9'-0"
SCHEDULED
CEILING AS
A.F.F
3ƒ"
STANDARD WALL - FLOOR TO CEILING
ACOUSTICAL SEALANT
BASE AS SCHEDULED
(BOTH SIDES)
" GYPSUM BOARD8
5
CHART FOR GAUGE
ALLOWABLE HEIGHTS
FRAMING- REFER TO
" METAL STUD 2
1
2
FOR SPECIFIED CEILING
SPECIFICATIONS
ONLY REFER TO
SHOWN FOR REFERENCE
TEGULAR CEILING
AS REQUIRED
BRACING
TYPICAL
STRUCTURE ABOVE
WALL
FLOAT OUT WITH
METAL EDGE TRIM
A.F.F
3ƒ"
WALL CAVITIES
INSULATION IN ALL
FULL BATT ACOUSTICAL
BASE AS SCHEDULED
(BOTH SIDES)
" GYPSUM BOARD8
5
CHART FOR GAUGE
ALLOWABLE HEIGHTS
FRAMING- REFER TO
" METAL STUD 2
1
2
WALL
FLOAT OUT WITH
METAL EDGE TRIM
FOR SPECIFIED CEILING
SPECIFICATIONS
ONLY REFER TO
SHOWN FOR REFERENCE
TEGULAR CEILING
AS REQUIRED
BRACING
TYPICAL
STRUCTURE ABOVE
STANDARD WALL - FLOOR TO CEILING
ACOUSTICAL BATT INSULATION TO 4' EACH SIDE OF WALL
ACOUSTICAL SEALANT
MASTIC
CONT. BED OF ACOUSTIC
SET BOTTOM TRACK IN
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
7
:
2
6
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
6
_
1
0
_
d
e
ta
ils
_
n
e
w
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
& DETAILS
PARTITION TYPES
A6.10
1.
2.
SIMILAR FINISHES.
HARDWARE SPECIFICATIONS
CONTRACTOR TO REFER TO SHEET A1.50 FOR FRAME FINISH COLOR. VERIFY WITH TENANT.
GENERAL NOTES/FINISHES
MORTISE LOCKSETS:
HARDWARE FINISH (U.N.O.):
LOCK CORES:
PASSAGE LATCHSET:
DUMMY TRIM ONE SIDE:
BUTT DOOR HINGES:
DOOR CLOSER:
DOOR STOPS:
AUTOMATIC
FLUSH BOLTS:
DUST PROOF STRIKE:
TO BE VERIFIED WITH BUILDING MANAGEMENT.
STANDARD HINGES FOR OTHER DOORS (1279, 4•"x 4•")
(BB1279, 4•"x4•")
CONCEALED BALL BEARING FOR DOORS W/CLOSERS
180°, WHETHER OR NOT SHOWN TO DEGREE OF OPENING
SUFFICIENT TO CLEAR TRIM WHEN DOOR SWINGS
US4 FINISH PROVIDE IN WIDTH
HAGER COMPANIES OR EQUAL
TO BE VERIFIED WITH BUILDING MANAGEMENT
AS NOTED ON HARDWARE SCHEDULE
OFFICE LOCKSET:
WALL BUMPERS: IVES WS406CCV OR EQUAL, US26D
FLOOR STOPS: TRIMCO #W1211 OR EQUAL, US26D
PROOF STRIKE OR EQUAL, US26D
TRIMCO MODEL #3910 DUST
#3910 DUST PROOF STRIKE, US26D
TRIMCO MODEL #3815 (PAIR) WITH
USE 4011T CYLINDER FOR ADA, PROVIDE HOLD OPEN
LCN 4010T SERIES OR EQUAL WITH METAL COVER, ALUMINUM
FRONT ENTRANCE LOCKSET:
EGRESS/EXIT LOCKSET:
TURN/LEVER LOCK:
CORBIN RUSSWIN ML2000 SERIES MORTISE LOCKS OR EQUAL;
SATIN CHROME = US26D/626 BHMA
CORBIN RUSSWIN ML2010 OR EQUAL
CORBIN RUSSWIN ML2057 OR EQUAL
CORBIN RUSSWIN ML2057 OR EQUAL
CORBIN RUSSWIN ML2051 OR EQUAL
CORBIN RUSSWIN ML2050 OR EQUAL
LEVER AND ROSE STYLE:PRINCETON "PSA" OR EQUAL (PREFERRED BY TENANT)
CORBIN RUSSWIN 519F10 X US26D/626 OR EQUAL
CORBIN RUSSWIN INTERCHANGEABLE CORE OR EQUAL
CORBIN RUSSWIN ML2051 OR EQUAL (USED WITH WOOD DOORS ONLY)
REFER TO SHEET FINISH SPECIFICATIONS (C) ON SHEET A1.50 FOR FRAME FINISH3.
DOOR SCHEDULE
KEYING SCHEDULE
ALL DOOR HARDWARE INCLUDING LATCHES, LOCKSETS AND HINGES TO BE BRUSHED STAINLESS STEEL OR
CL
6'-0"
DOOR TYPES
TYPE 3
DOOR FRAME TYPES
TYPE 1
1/2" = 1'-0"
1/2" = 1'-0"DOOR FRAME TYPES
TYPE D
DOOR FRAME TYPES
DOOR WITH CUSTOM STAIN TO MATCH WD-1
SOLID CORE FLUSH CHERRY WOOD VENEER
DOORS WITH CUSTOM STAIN TO MATCH WD-1
SOLID CORE FLUSH CHERRY WOOD VENEER
CL
TYPE 2
3'-0"
10
"
HARDWARE SCHEDULE
6'-0"
‚" CLEAR TEMPERED GLASS SIDELITE
CLEAR ANODIZED ALUMINUM FRAME WITH
THE FOLLOWING:
FRAME SHOP DRAWINGS INDICATING
CONTRACTOR IS REQUIRED TO SUBMIT
FRAME ELEVATIONS
GLAZING WIDTHS
FRAME SCHEDULE
OF COMPLETED WORK.
PROCESS MAY RESULT IN THE REJECTION
NON-COMPLIANCE TO THE SUBMITTAL
DOOR FRAME NOTES
1•"1•"
TYPE A
CLEAR ANODIZED ALUMINUM FRAME
REFER TO SCHEDULE
11B/A6.10
1•"1•"
TYPE B
3'-0" MAX.
BUTT-JOINT TO BE „" CLEAR SILICONE
…" CLEAR TEMPERED BUTT-JOINED GLASS
CLEAR ANODIZED ALUMINUM FRAME WITH
11B/A6.10
1•"1•"1•"
TYPE E
CONFERENCE ROOM
BUTT-JOINT TO BE „" CLEAR SILICONE
…" CLEAR TEMPERED BUTT-JOINED GLASS
CLEAR ANODIZED ALUMINUM FRAME WITH
11B/A6.10
3'-0" MAX
11A/A6.10
11A/A6.10
CL CL
3'-0"
LOCATIONS.
SPECIFICATIONS OF STRIKES AS CORRESPONDS WITH EXISTING FIELD CONDITIONS AND CARD READER
INSTALLATION OF SECURITY HARDWARE. CONTRACTOR PRICING IS TO INCLUDE THE APPROPRIATE
SELECTION OF ELECTRICAL AND/OR MECHANICAL DOOR STRIKES PRIOR TO THE ORDER OR
GENERAL CONTRACTOR IS TO CONSULT WITH CLIENT AND ARCHITECT ON THE REQUIREMENTS & 4.
4.
1.
2.
3.
CL
3'-0"
1/2" = 1'-0"DOOR ALTERNATES
ALTERNATES LIST (REFERENCED FROM A0.00)
ALT#3 AND #5ALT #7 AND #8
SERVER & EGRESS DOORS)
(FOR STORAGE ROOM,
STOREROOM LOCKSET:
HARDWARE ALTERNATES
04 1/2" = 1'-0"
12
/
A
6
.
10
12
/
A
6
.
10
12
/
A
6
.
10
REFER A1.21
1•"
TYPE C
3'-0" MAX.
1•"
BUTT-JOINT TO BE „" CLEAR SILICONE
…" CLEAR TEMPERED BUTT-JOINED GLASS
CLEAR ANODIZED ALUMINUM FRAME WITH
11B/A6.1011A/A6.10
REFER A1.21 FOR FRAME OPENING WIDTH REFER TO A1.21 FOR FRAME OPENING WIDTH
REFER A1.21 FOR FRAME OPENING WIDTH
CL
4'-0"
TYPE 4
DOORS WITH CUSTOM STAIN TO MATCH WD-1
SOLID CORE FLUSH CHERRY WOOD VENEER
8
"
8"1'-8"8"8"1'-8"8"
3
'
-
3
"
(
4
8
"
M
A
X
)
3
'
-
3
"
(
4
8
"
M
A
X
)
3
'
-
3
"
(
4
8
"
M
A
X
)
3
'
-
3
"
(
4
8
"
M
A
X
)
3
'
-
3
"
(
4
8
"
M
A
X
)
3
'
-
3
"
(
4
8
"
M
A
X
)
8
'
-
10
•
"
8
'
-
10
•
"
8
"
8"1'-8"8"
PROVIDED TO TENANT AT TIME OF PUNCH LIST.
TO RECEIVE UNIQUE KEY FROM ALL OTHER DOORS. 6 KEYS TO BE
LOCKSETS FOR ALL EGRESS DOORS TO BE KEYED ALIKE. EGRESS DOORS
STORAGE ROOMS
SERVER ROOM DOOR
PRIVATE OFFICES
AT TIME OF PUNCH LIST:
ALL KEYS FOR THE FOLLOWING LOCATIONS TO BE LEFT IN LOCKSETS
ALL LOCKSETS TO BE KEYED UNIQUELY (2 KEYS FOR EACH LOCKSET).
KEYS FROM LANDLORD FOR ALL LOCKS AT TIME OF PUNCH LIST WALK THROUGH.
ALL LOCKS TO BE ON BUILDING MASTER. TENANT TO RECEIVE TWO MASTER
2'-0"
1'
-
6
"
AND 1/4" CLEAR TEMPERED GLASS INSERT
DOOR WITH CUSTOM STAIN TO MATCH WD-1
SOLID CORE FLUSH CHERRY WOOD VENEER
AND 1/4" CLEAR TEMPERED GLASS INSERT
DOOR WITH CUSTOM STAIN TO MATCH WD-1
SOLID CORE FLUSH CHERRY WOOD VENEER
LINE OF DOOR FRAME BEYOND
DOOR HARDWARE AS SPECIFIED
(THIN PROFILE)
LATCH GUARD
FINISHED AS DIRECTED BY LANDLORD
(ELEVATION ON MULTI-TENANT CORRIDOR SIDE)
DOOR FRAME FINISHED AS DIRECTED BY
LANDLORD
(TENANT SIDE TO BE CLEAR
ANODIZED)
DOOR - REFER TO SCHEDULE FOR HEIGHT
FINISH:
MULTI-TENANT CORRIDOR SIDE
FINISHED AS DIRECTED BY LANDLORD
TENANT SIDE FINISHED WD-1
REFER TO SCHEDULE REFER TO SCHEDULEREFER TO SCHEDULE
TO MATCH WD-1
SOLID CORE FLUSH WOOD DOOR
WOOD LOUVERS - FLAT SLAT 18" X 24")
GRILLE WITH FIXED LOUVERS (MARSHFIELD
CLEAR ANODIZED ALUMINUM DOOR
LATCH GUARD ELEVATION @ DOOR
1•"
TYPE F
3'-0" MAX.
1•"
BUTT-JOINT TO BE „" CLEAR SILICONE
…" CLEAR TEMPERED BUTT-JOINED GLASS
CLEAR ANODIZED ALUMINUM FRAME WITH
11B/A6.1011A/A6.10
REFER A1.21 FOR FRAME OPENING WIDTH REFER TO SCHEDULE
ALT #6 - 7'-10•"
ALT#3
REFER TO 05/A2.10. INCLUDE ALTERNATE HARDWARE SHOWN ON 08/A2.10
COMPLETE WOOD AND GLASS DOOR(S) AT TENANT MAIN ENTRY / RECEPTION (DOOR #500).
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND INSTALL
ALT#7
ALT#8
#501). REFER TO 10/A2.10
INSTALL WOOD AND GLASS DOOR ENTRANCE TO SMALL CONFERENCE ROOM (DOOR
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND
(DOOR #506). REFER TO 16/A2.10
INSTALL WOOD AND GLASS DOOR AT DOOR BETWEEN RECEPTION AND OPEN OFFICE
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND
ALT#5
REFER 12/A2.10. INCLUDE ALTERNATE HARDWARE SHOWN ON 08/A2.10
COMPLETE WOOD AND GLASS DOOR(S) AT LARGE CONFERENCE ROOM (DOOR #503).
GENERAL CONTRACTOR TO PROVIDE SEPARATE LINE-ITEM PRICING TO SUPPLY AND INSTALL
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
7
:
2
9
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
a
6
_
1
1
_
d
o
o
r
s
_
n
e
w
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
A6.11
HARDWARE SCHEDULE
DOOR SCHEDULE,
DOOR & FRAME TYPES,
1•
"
8
'
-
4
•
"
1•
"
1•
"
8
'
-
6
"
FOR DOOR WIDTH
1•
"
8
'
-
6
"
1•
"
8
'
-
6
"
1•
"
8
'
-
6
"
1•
"
8
'
-
4
•
"
1•
"
1•
"
8
'
-
4
•
"
1•
"
10
"
HARDWARE
SET FOR
HARDWARE
REFER TO
EQUAL PANELS OF GLASS AT 3'-0" MAX
1•
"
8
'
-
6
"
(EQUAL GLASS PANELS @ 3'-0" MAX PER PANEL)
1•
"
8
'
-
4
•
"
1•
"
WIDTH
FOR FRAME OPENING
10
"
FOR DOOR WIDTHFOR DOOR WIDTHFOR DOOR WIDTH
REFER TO SCHEDULE
FOR DOOR WIDTH
HARDWARE
SET FOR
HARDWARE
REFER TO
VARIES,
1•
"
8
'
-
6
"
(EQUAL GLASS PANELS @ 3'-0" MAX PER PANEL)
1•
"
8
'
-
4
•
"
1•
"
FOR DOOR WIDTH (EQUAL GLASS PANELS)
REVISION/BYDATE
ISSUE LOG:
NO.
DRAWN CHECKED
PROJECT NO.:
ISSUE DATE:
CORPORATE HEADQUARTERS
1
0
:
1
7
:
3
4
A
M
7
/2
2
/
2
0
1
3
P
:
\
D
e
s
ig
n
-
C
o
r
p
o
r
a
t
e
S
e
r
v
ic
e
s
\
M
a
r
c
u
s
&
M
illic
h
a
p
\In
d
ia
n
a
p
o
lis
\
In
d
ia
n
a
p
o
lis
2
0
1
3
\
C
A
D
D
file
s
a
n
d
P
D
F
s
\
5
C
o
n
s
t
r
u
c
tio
n
D
o
c
u
m
e
n
t
s
\
A
7
.
1
0
.
d
g
n
CALABASAS, CA 91302
SUITE 400
23975 PARK SORRENTO
313.250
07/22/2013
0
0
0
0
0
0
0
0
TO DESIGN INTENT
ORDER TO INSURE ADHERANCE
ENGINEERING SHEETS IN
ALL ARCHITECTURAL AND
SUBCONTRACTORS WITH
CONTRACTOR TO PROVIDE
INDIANAPLOIS
INDIANA
46240
INDIANAPOLIS, IN
SUITE #500
600 EAST 96TH STREET
5,605 RSF
4,631 USF
OFFICEOFFICEOFFICERM OFFICE
OFFICE OFFICE OFFICEBREAK/COPY STORAGE
OFFICE
SERVER RECEPTION
COAT
CONFERENCE
SMALL
OFFICEOFFICE
CONFERENCE
LARGE
B
B B
B
B
B1 B1
B1B1
B
C1 C1
C1C1
C1C1
D
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B1
B1
B BBBBB
BBBBBB
BBBBBB
B B B B B
B1
S
D
DD
DD
S
S
S S S
S S S S S S S
S
S
S
3
EE EE
C1 C1 C1
C1C1C1
E
E
514 515 516 517 518
501 500
513 512 511 510 509 508 507 503
502
505 504
STOR.
OFFICE
OPEN
506
OFFICE
OPEN
519
9'-0"
9'-0"
9'-0"
9'-0"
3S
3
S
3
B
B
B
C1C1
B1
E
E
E
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O
F
W
O
RK
LIM
IT
O
F
W
O
R
K
D
J
S
S
A
A1
B
B1
E
D
F
BUILDING STANDARD 2X4; VERIFY SPECIFICATION WITH LANDLORD
BUILDING STANDARD 2X2; VERIFY SPECIFICATION WITH LANDLORD
FLU 24 B 2 T8 E 120 G PS
FOCAL POINT - LUNA 2X4 - WITH PERFORATED SHEILDING
FLU 22 B 2 T8 E 120 G PS
FOCAL POINT - LUNA 2X2 - WITH PERFORATED SHEILDING
C
DIMMABLE FIXTURE - FLU 22 B 2 T8 D 120 G PS
FOCAL POINT - LUNA 2X2 - WITH PERFORATED SHEILDING
DIMMABLE FIXTURE - FLU 24 B 2 T8 D 120 G PS
FOCAL POINT - LUNA 2X4 - WITH PERFORATED SHEILDING
BE INSTALLED ON SEPARATE DIMMER SWITCH.
WITH FOUR (4) CRS298QR-S TRACK HEADS. TRACK TO
MAGELLAN LOW VOLTAGE FLEXIBLE 4' TRACK CRS2964-S
HE WILLIAMS LINEAR FLUORESCENT - 75-4--32-EBD1
NEW ILLUMINATED EDGE LIT EMERGENCY EXIT SIGN (W/ GREEN LETTERING)
WITH DIRECTION OF TRAVEL ILLUMINATED
NEW ILLUMINATED EDGE LIT EMERGENCY EXIT SIGN (W/ GREEN LETTERING)
TENANT PROVIDED PROJECTION SCREEN REFER TO A0.02 FOR SPECIFICATION
CEILING MOUNTED JUNCTION BOX
CEILING MOUNTED SPEAKER, INSTALL CONDUIT AS REQUIRED BY CODE
WHITE SINGLE POLE SWITCH WITH MOTION SENSOR
WHITE SINGLE POLE SWITCH
WHITE LIGHT SWITCH WITH DIMMER CONTROL SENSOR SWITCH.
BUILDING STANDARD GRID
HE WILLIAMS SQUARE DOWNLIGHT - PVSQ60-1 26T-EBD1 (DIMMABLE)
C1
SYMBOLS LEGEND A7.10
01.
02.
03.
04.
HVAC PLAN
AND
PLUMBING DIAGRAM
15 REFLECTED CEILING PLAN 1/8" = 1'-0"
PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50
AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN
PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA
REQUIRED BY CODE.
CONTROLS (ULTRASONIC & MOTION DETECTION) AND/OR RELAY TIME CLOCKS AS
RELOCATION/REMOVAL. PROVIDE ENERGY MANAGEMENT CONTROLS, SUCH AS SENSOR
RELOCATED/REMOVED LIGHT FIXTURES WITH ARCHITECT PRIOR TO
PROJECT CRITERIA MEETS INDIANA ASHRAE 90.1 ENERGY CODES. COORDINATE
CONTRACTOR AND/OR DESIGN BUILD CONTRACTOR. CONTRACTOR TO VERIFY THAT
LIGHTING PLACEMENT AND QUANTITIES ARE TO BE VERIFIED BY ELECTRICAL
CLOCK CONTROLS. EXISTING SWITCHES TO BE CONVERTED AS REQUIRED BY CODE.
CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME
OCCUPANCY WITHIN ANY PORTION OF OCCUPIED PORTION IS DETECTED. PROVIDE
A ONE-BUTTON OVERRIDE. OCCPUANCY SENSORS ARE TO BE LOCATED USCH THAT
PROVIDE COMBINATION UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH
IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS,
RCP GENERAL NOTES
01.
02.
03.
MECHANICAL NOTES
SCOPE INTENT IS FOR EXISTING MECHANICAL SYSTEMS TO REMAIN.
CEILING AND WALL LAYOUT. NO MAIN DUCTWORK BEING RELOCATED.
EXISTING FLEX DUCT AND DIFFUSERS BEING RELOCATED AS NECESSARY PER
ADDITIONAL WORK IS REQUIRED.
MECHANICAL CONTRACTOR IS RESPONSIBLE FOR NOTIFYING APPLICABLE PARTIES IF
REFER TO A1.40 FOR CEILING LAYOUT AND ADDITIONAL NOTES.
HEAT PUMP
VAV/
REQUIRED
& FLEXDUCT IF
RELOCATED DIFFUSERS
REMAIN
SUPPLY DUCTS TO
PUMP AND MAIN
BOXES OR HEAT
EXISTING VAV
MECH. DIFFUSER RELOCATION
04.
DETERMINING FINAL DIFFUSER LAYOUT.
SUBCONTRACTOR/CONTRACTOR. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR
MECHANICAL LAYOUT AND QUANTITIES ARE TO BE VERIFIED BY MECHANICAL
CEILING
CEILING
1 1/2" V.
FLOOR
FINISHED
FINISHED FLOOR
2" W.
2" W.
4" W.
EXIST
DRAIN
TO BUILDING
SINK2" W.
EXIST
4" V.
1 1/2" V.
1/8" = 1'-0"12 PLUMBING RISER DIAGRAM
REFER TO FLOORPLAN AND
CASEWORK ELEVATIONS
FOR SINK LOCATIONS.