HomeMy WebLinkAbout13090088 Building PlansEXISTING HOUSE
�XISTING HOUS�
GENERAL FLOOR PLAN NOTES:
I. ALL INTERIOR WALL ARE 4X� OR 4X6 AS
SHOWN. EXTERIOR WALL ARE 4X4 OR 2X6
AND ONE LAYER OF I/4' MATERIAL ON
EXTERIOR. ALIGN EXTERIOR OF WALL WITH
FOUNDTION WALL. ALL ANGLED WALLS ARE
95 DEGREES FROM ADJhCENT WALL
IINLE$S OTHERWISE NOTED.
2. CONFIRM ALL HEADER HEIGHTS AND SIZES
PRIOR TO START OF FRAMING. ALL OPENINGS
ARE TO BE 4' FROM ADJACENT WALL
UNLESS NOTED OTHERWISE.
3. YERIFY ALL TYPES AND SIZES OF WINDOW
UNITS AND �OORS WITH OWNER/BUILDER.
NOTIPY BUILDER OP ANY DISCREPANCIES.
q. VERIFY LOCATION, TYPES ANS SIZES Of
VENTS AND EXTERIOR TRIM WITH
OWNER/BUILDER.
5. INSULATE HIDDEN AREAS OR ASSE%BLIES
BEFORE COYERING.
6. BUILDER/LUMBER SUPPLIER SHALL SPECIFY
SIZES OP DIMENSIONAL LUMBER POR FLOOR
AND ROOF SY5TEM5. NOTIFY BUILDER/LUMBER
SUPPLIER I%MEDIATELY OF ANY
DISCREPANqES.
l. STEEL LINTELS, PROPERLY SIZED, ARE TO BE
PROVIDED OVER ALL OPENINGS OR WOOD
BEARING AREAS TO SIIPPORT MASONRY
YENEER.
8. ALL ROOF AND WALL INTERSECTIONS SHALL
BE FLASHED WITH ALUMINUM OR BETTER
MATERIAL.
30"X60" WINDOW
wi TRnNS nsv.
0 3 0
_ x
0
x
b
COVERED PORCH
OVER EXISTINC� DECK
8'-2" CLG. HGT.
POST NEW 4X9 WALL
13) 30"K60" WINDOWS
� = W/ 12" TRWNSOM$ ABOVE
I'-6
P�OPOSED PL�N
SCALE: I/4„=1'-0„
5 I/2"
3o•xso wiNOOw <
wi TRans. aev.
�
NEW 6H6 NEW 6X6 �
3-0 PO5T NEW ]X9 WALL POST
M ABOV& I �3) 30"X60" �UINDOWS
� nruce9 W/ 12" TRANSOfis aeove
5 I/2„
R00� P��N
SCALE: I/8"=1'-0"
THREE TAB
FIBERGLA55 $HMGLES
W/ ISU FELT OVER
V2" EXT. SHEATHING �
�+9
6" PREFINI$HED
AWM. G�TTER
ISLOPE TO DRAINI
Ixb SPRUCE N W 2X6 CEILING
FA5CIA BOARD R FTERS
P-0" OVERHANG BLO N-IN INSULATION
V2" EXT. HIGH "R"
INSIIL SHEATHIN4
GYP.BOARD
!X� WALL
6X6 TREATED
� Posr
TT. INSUL IR-131
EXISTWG DECK ! ! EXISTWG DECK
79"0%37" POURED � i �i �
CONCRETE�I � i I
� I I �
i�• FooTeR � �' �
�_J
�U��� SECTION
SCALE: I/9"=1'-0"
RE�R ELEV�TION
SCALE: I/9„=1'_0„
■■■
�
u
�E�T E�E�/�TION
SCALE: I/4"=1'-0"
GENERAL ELEVATION NOTES:
I. VERIFY ALL TYPES AND SIZES OF WINDOW
11NITS AND DOORS WITH BUILDER. NOTIFY
BIIILDER OF ANY DISCREPANCIES.
2. YERIFY LOCATIONS, TYPES AND SIZES OP
YENTS AND EXTERIOR TRIM WITH BUILDER.
3. ALL ROOP, CHIMNEY AND WALL
INTERSECTIONS SHALL BE FLASHED WITH
ALUMINUM OR BETTER MATERIAL.
■■■ ■■■
� �
uu
-
RIC�HT ELEV�TION
SCALE: I/q"=1'-0"
fxNOTExs
IT IS THE BUILDER/ OWNERS RESPONSIBILITY TO VERIFY
THE PROPER AIR SPACE BETWEEN ALL BRICK AND WOOD
WALLS WITH HOUSE WRAP. TO PREVENT WATER MFILTRATION.
BIJILDER/ OWNER SHOULD SEEK THE ASSISTANCE OF A
QUALIFIED ENGMEER FOR THE PROPER SIZING OF ALL
STRUCTURAL HEADERS.RAFTERS,SUPPORT BEAMS,
LAMINATED BEAMS. JOISTS. FOOTINGS. ETC. IT IS THE
BUILDER/ OWNER RESPONSIBILITY TO VERIFY ALL DIMENSIONS
e DESIGN OF THESE DOCl1MENT5 FOR ACCURACY.
0 m �
� ' � � W �
cp � Q � U �
U �
cn
�
Z
�
z �
O p�
� 0
Ca
� (� � Z
-W� � ~ O
O ~
�6- ��
� U
� �
} �
v J
z
O
�
a
�
�
Z
Z
W
U
ZI^
V
�_
�F
N �
WW o �
0
N �t^£
� � ao�
w
w a z
E o,�
� z��
z -^-o
r �a
�
a >za
3°w=,
w o�
� = a
Q W w
3
'_n
V /
SHEET NO
� — I
� �
DATE
9/5/13
DU1N NO
�