HomeMy WebLinkAbout12005_2013-08-09_A203NORTH
Project No.
Sheet No.
Revisions:
Drawn By
Checked By
W
CHURCH SOLUTIONS
T&
BYRU
M
A
R
C
H
ITEC
TS
required for the proper execution and
performance and completion of the require-
architectural elements and, in some cases,
service for use solely with respect to this
These drawings indicate the general scope of
the project in terms of architectural design
concept, the dimensions of building, the major
the structural, mechanical, and/or electrical
systems. The Drawings do not necessarily
indicate or describe all work required for full
m
ents of the Contract. On the basis of
the general scope indicated or described, the
trade contractors shall furnish all item
s
Use of Documents
projects or additions to this Project without
Project and shall not be used on other
Project are instruments of the Architect's
documents prepared by the Architect for this
The Drawings, Specifications, and other
written permission and due compensation to
Certified By
completion of the work.
the Architect.
Scope DrawingsT&W Corporation
46241
3841 W
. M
orris St.
Indianapolis, Indiana
621 South Range Line Road, Carmel, Indiana 46032
Carmel United Methodist Church
Specially commissioned by T&W Church Solutions, and used under license.
12005 JW
B
CAD
8-9-13
FIRST FLOOR REFLECTED CEILING PLANA203
A203
01
SCALE: 3/32" = 1'-0"
FIRST FLO
O
R REFLECTED CEILING
PLAN
URTIH
910060
NE STATE OF
IS
IRET
E RG
A NAIDD
A
R
C
SEG
E
ONJ
W
R
YEL
B
RET
ISNo.
Y
ED
TCE M
Additions and Renovations to
Copyright 2013
C
160 W. Carmel Drive, Suite 240
Carmel, Indiana 46032
317-574-8808
www.byrumarchitects.net
Date
01
A402
02
A401
01
A401
02
A402
2X4 SUSPENDED ACOUSTICAL
PANEL CEILING
AT ±8'-10" A.F.F.
EXISTING AT ±8'-10" A.F.F.
2X4 SUSPENDED ACOUSTICAL
PANEL CEILING
TO M
ATCH
EXISTING AT ±8'-10" A.F.F.
2X4 SUSPENDED ACOUSTICAL
PANEL CEILING
TO M
ATCH
EXISTING AT ±8'-10" A.F.F.
EXISTING AT ±9'-0" A.F.F.
EXISTING AT±7'-8" A.F.F.
2X2 SUSPENDED ACO
USTICAL
PANEL CEILING AT ±8'-0" UPPER
2X2 SUSPENDED ACOUSTICAL PANEL
CEILING
AT SAM
E HEIGHT AS EXISTING
EXISTING
AT ±9'-0" A.F.F.
E.I.F.S. (SEE SECTIONS)
E.I.F.S. CO
NTROL JOINTS
E.I.F.S. (SEE SECTIONS)
E.I.F.S. CO
NTROL JOINTS
20" X 40" ATTIC ACCESS
PANEL COVER W
ITH E.I.F.S.
THIS JO
INT DO
ES NO
T
ALIG
N W
ITH JOINTS IN
SOFFIT (SEE EXTERIOR
ELEVATIONS)
THIS JO
INT DO
ES NOT
ALIG
N W
ITH JO
INTS IN
SOFFIT (SEE EXTERIOR
ELEVATIONS)
SEE EXTERIO
R ELEVATIONS
FOR JO
INTS ALIG
N W
ITH
CO
LUM
N CENTERLINES
(TYPICAL)
DRYW
ALL
AT 9'-0" A.F.F.
ENSURE 4' X 4'
ACCESS TO
PANEL ABO
VE
2X2 SUSPENDED ACO
USTICAL
PANEL CEILING AT 9'-0" A.F.F.
2X2 SUSPENDED ACOUSTICAL
PANEL CEILING
AT ±9'-4" A.F.F.
±16" W
IDE DRYW
ALL BULKHEADS
BO
TTOM
AT ±8'-7" A.F.F.
±12" W
IDE DRYW
ALL
BULKHEADS BOTTOM
AT ±8'-7" A.F.F.
±12" W
IDE DRYW
ALL
BULKHEADS BOTTOM
AT ±8'-7" A.F.F.
DRYW
ALL BULKHEADS
AT ±8'-7" A.F.F.
2X2 SUSPENDED
ACOUSTICAL PANEL
AT ±8'-10" A.F.F.
R13'-8 1/2"
5'-7 3/8"
5'-7 3/8"
DRYW
ALL
AT 8'-0" A.F.F.
EXISTING
VAULTED
DRYW
ALL
EXISTING
SKYLIG
HTS
2X4 SUSPENDED ACOUSTICAL
PANEL CEILING
AT ±8'-6" A.F.F.
2X4 SUSPENDED ACO
USTICAL
PANEL CEILING AT ±9'-8" A.F.F.
2X4 SUSPENDED ACOUSTICAL
PANEL CEILING
AT ±8'-10" A.F.F.
2X4 SUSPENDED ACOUSTICAL
PANEL CEILING
AT ±9'-8" A.F.F.
EXISTING
CEILING
AT ±9'-6" A.F.F.
2X2 SUSPENDED ACOUSTICAL
PANEL CEILING AT ±9'-10" A.F.F.
LEVEL F.F.
DRYW
ALL BULKHEADS
BOTTO
M
AT ±7'-3" A.F.F.
EXISTING
CEILING
AT
AT ±9'-0" A.F.F.
O
FFICE
B163
O
FFICE
B159
OFFICE
B144
O
FFICE
B175
O
FFICE
B166
O
FFICE
B172
O
FFICE
B169
O
FFICE
B171
CO
NFERENCE
B148
LIBRARY/
STO
RAG
E
B174
STAIR
BS6
RECEPTIO
N
B157
RO
O
M
B164
W
O
RK
AREA
B145
G
ATHERING
CAFE
B146
VESTIBULE
B149
CANO
PY
EQUIPM
ENT
B154
A.V.
W
O
M
EN
A122
SANCTUARY
B136
CHANCEL & CHOIR
B135
NARTHEX
B137
CHAPELB111
CLASSROO
M
B117
CLASSRO
OM
B123
CLASSRO
O
M
B127
CLASSRO
O
M
B109
CLASSRO
O
M
B132
CLASSRO
O
M
B106
CLASSRO
O
M
B102
CLASSRO
O
M
B118
CO
URTYARD
CO
URTYARD
CRY ROO
M
B124
RESTRO
O
M
B126
RESTRO
O
M
B108 RESTRO
O
M
B107
STORAGEB110
W
O
M
EN
B114 & B115
M
EN
B113
STAIRBS1
CO
RRIDO
R
B116
CO
RRIDO
R
B121
CORRIDOR
B122
CORRIDOR
B130
CO
RRIDO
R
B131
STO
RAG
E
B133
STAIR
BS2
W
O
M
EN
A110
M
EN
A109
CO
RRIDO
R
A102
CO
RRIDO
R
A103
CLASSRO
O
M
A107
CLASSRO
O
M
A108
OFFICE
A104OFFICEA105
STO
R.
A106
KITCHEN
A112
STAIR
AS2 ELECTRICAL
A116
STO
RAG
E
A114
G
YM
NASIUM
A115
VESTIBULE
B143
CORRIDOR
B158
STO
R.
B167
CO
RRIDO
R
B173
CO
RRIDO
R
B142
STO
R.
A111
O
FFICE
B161
KITCHEN
B147
CO
URT
M
ECH.
STOR.A118VESTIBULEA101
RESTRO
O
M
B105
ACCESS
B134
JANITOR
B138
STO
RAG
E
B140
VESTIBULE
B139
CO
RRIDO
R
B155
M
EN
A123
COLONNADE
O
FFICE
B168
SERVER
B162
B111
STAIR
BS6
STAIR
BS3
STAIR
BS5
STAIRAS1
O
FFICE
B170
O
FFICE
B165
RESTRO
O
M
B141
FAM
ILY
O
FFICE
B176
O
FFICE
B160
CO
RRIDO
R
B156
EXISTING
ACCESS
PANEL ABOVE
ENLARGE ATTIC ACCESS
OPENING
AS NEEDED PER
EXISTING
ATTIC H.V.A.C
UNITS - COO
RDINATE
W
ITH M
ECHANICAL
1,520
350
190
300
150
390240
200
90
300
210280 40
60
9090
200
150
150
60
60
110
240
3,790
1,300
600
110
870
1,30050
870
70 110
50
80
130
920
890
610
160
30
20
20
20
540
490
180 30
1010
630
630
280
280
40
630
730 400
80
360
5,480
90
40
40
280
186140
297
728
3737
584
275
148
713
145
164
612160
67
64
80
551
864
2333
1,297
546
551
95
3,589
197
140
372
243
268
172
101
265
223
110
165
195
78
190
562
2
3
4
5
6
7
KJHGFEDC
BA
1
54
93
SS
S
S
S
S
SS
S S S
SS
SS
S
S
S
SS
S S S S S S
S
S S S S S S
S S S S S S
S S
S
S S S
S
S
S
S
S
S S S
S
SS
S
S
SS
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
E E E
EEE
E E
E
E
E
E E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
EEE
EE
EE
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
EE
E
EE
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
EE
E E E
S
S
S
S
F
S
S
S
S
S SSSSS
E
S S
S
S
S S
S S
S
SSS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
E
E
E
S
S
S
S
S
S
S
S
S S SS
S
S
S S S
S
SS
S
S
S
S SS
S
S
S
S S
S
S S
S
S
S
S
S
S
S
S
SS
S3
3
S 3
S
S
S S 3S
S
S
S
S
S S S S
S3S
S
SS
S
S
S
S
S 3