Loading...
HomeMy WebLinkAbout12005_2013-08-09_A501Project No. Sheet No. Revisions: Drawn By Checked By W CHURCH SOLUTIONS T& BYRU M A R C H ITEC TS required for the proper execution and performance and completion of the require- architectural elements and, in some cases, service for use solely with respect to this These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of building, the major the structural, mechanical, and/or electrical systems. The Drawings do not necessarily indicate or describe all work required for full m ents of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all item s Use of Documents projects or additions to this Project without Project and shall not be used on other Project are instruments of the Architect's documents prepared by the Architect for this The Drawings, Specifications, and other written permission and due compensation to Certified By completion of the work. the Architect. Scope DrawingsT&W Corporation 46241 3841 W . M orris St. Indianapolis, Indiana 621 South Range Line Road, Carmel, Indiana 46032 Carmel United Methodist Church Specially commissioned by T&W Church Solutions, and used under license. 12005 JW B CAD 8-9-13 DOOR AND FRAME SCHEDULEA501 URTIH 910060 NE STATE OF IS IRET E RG A NAIDD A R C SEG E ONJ W R YEL B RET ISNo. Y ED TCE M Additions and Renovations to Copyright 2013 C 160 W. Carmel Drive, Suite 240 Carmel, Indiana 46032 317-574-8808 www.byrumarchitects.net A105A OPENING HEIG HT W IDTH EXISTING THICK M AT. DO OR HARDW ARE DOOR, FRAME, AND HARDW ARE SCHEDULE ELEV. GLASS ELEV. FINISH M AT. FINISH FRAM E G LASS RATING REM ARKS X O PENING A105B A108 A122 A123 A201A A201B A201C B111 B117 B118 B130A B130B B130C B136A B136B B136C B144 B147A B147B B148A B148B B148C B149A B149B B149C B149D B157 B160 B161 B164 B171 B175 B176 B025 B045 A104 B162 B058A B058B B058C A103 B058D B061 A105A A105B A108 A122 A123 A201A A201B A201C B111 B117 B118 B130A B130B B130C B136A B136B B136C B144 B147A B147B B148A B148B B148C B149A B149B B149C B149D B157 B160 B161 B164 B171 B175 B176 B025 B045 A104 B162 B058A B058B B058C A103 B058D B061 A102B A102A A102B A102A PR. 3'-0" 1 3/4" ALUM D1 ALUM TEM P. TEM P. 7'-0" SF1 PREFINISH ALUM . PREFINISH ALUM . PR. 3'-0" 1 3/4" ALUM D1 ALUM TEM P. TEM P. 7'-0" SF1 PREFINISH ALUM . PREFINISH ALUM . PR. 3'-0" 1 3/4" ALUM D1 ALUM TEM P. TEM P. 7'-0" SF1 PREFINISH ALUM . PREFINISH ALUM . PR. 3'-0" 1 3/4" ALUM D1 ALUM TEM P. TEM P. 7'-0" SF1 PREFINISH ALUM . PREFINISH ALUM . INSULATED GLAZING; A.D.A. SEQUENCED AUTO OPENER ON W EST LEAF A.D.A. SEQUENCED AUTO OPENER ON W EST LEAF PR. 3'-0" 1 3/4" ALUM D1 ALUM TEM P. TEM P. 7'-0" SF2 PREFINISH ALUM . PREFINISH ALUM . EXISTING 3'-0" 1 3/4" D2 7'-0" PAINT KD F2 PAINT RELOC. RELOCATE DOOR, FRAME AND HARDW ARE FROM EXISTING OPENING A108 DO O R TYPES ENTRANCE W ITH ALUM INUM D1 (SEE FINISH NOTE BELOW) TEM PERED G LAZING D2 D3 D4 W O OD STOPS BO TH SIDES 5/8" X 5/8" PREFINISHED OPENING IN DO OR EDG ES O F LITE W OO D VENEER AT PAINTED W ITH FULL W IRE G LASS LITE SO LID CO RE W O OD VENEER STOREFRO NT FRAM E TYPES F1 F2 FRAM E HOLLOW M ETAL FRAM E KNO CK-DO W N 2" SEE SCHED. 2 2" SEE SCHED. 2 SEE SCHED.4" F4 W ITH W IRE GLASS AND HOLLOW M ETAL FRAM E D8 CLEAR ANO DIZED ALUM INUM SECTIONAL (HIGH-LIFT WHERE INDICATED) O VERHEAD DOOR W ITH TEM PERED GLASS LITES, SEALS, AND OPENER APPLIED M ULLIONS SEE SCHED.2" 7'-0"2" SEE SCHED.2" 2" 3'-0" 2" 3'-0" 2" 3'-0" 2" 2" 2" SEE SCHED. MATCH EXISTING WINDOWS AT CORRIDOR B156 F5 W ITH W IRE GLASS AND HOLLO W M ETAL FRAM E APPLIED M ULLIONS D7 PREFINISHED AND DEADLOCK O VERHEAD CO ILING SECURITY SHUTTER W ITH CO IL HO USING WINDOW TYPES STO REFRO NT TYPES W1W2W3 SF1 SF2 4'-0" 4'-0" D5 1 3/4" W OO D PAINT KD F2 PAINT 3'-0" 7'-0" D7 1 3/4" W OO D PAINT PAINT 3'-0" 7'-0" 1 3/4" W OO D PAINT PAINT 3'-0" 7'-0" 90 M IN. 90 M IN. HM F1 HM F1 EXISTING EXISTING D2 1 3/4" W OO D PAINT KD F2 PAINT PR. 3'-0" 7'-0" EXISTING 20 M IN. 20 M IN. 1 3/4" W OO D PAINT 3'-0" 7'-0" 1 3/4" W OO D PAINT 3'-0" 7'-0" KD F2 PAINT KD F2 PAINT 1 3/4" W OO D PAINT PR. 3'-0" 7'-0" PAINT PR. 3'-0" 1 3/4" W OO D PAINT 7'-0" KD F2 PAINT PR. 3'-0" 1 3/4" W OO D PAINT 7'-0" PAINT HM F1 PR. 3'-0" 1 3/4" W OO D PAINT 7'-0" PAINT HM F1 PR. 3'-0" 1 3/4" W OO D PAINT 7'-0" PAINT HM F1 1 3/4" W OO D PAINT 3'-0" 7'-0" HM F3 PAINT 20 M IN. 1 3/4" W OO D PAINT 3'-0" 7'-0" HM PAINT W IRE 1 3/4" W OO D PAINT 3'-0" 7'-0" HM PAINT W IRE 1 3/4" W OO D PAINT 3'-0" 7'-0" HM PAINT 1 3/4" W OO D PAINT 3'-0" 7'-0" HM F3 PAINT 1 3/4" W OO D PAINT 3'-0" 7'-0" HM F3 PAINT 1 3/4" W OO D PAINT 3'-0" 7'-0" KD F2 PAINT 1 3/4" W OO D PAINT 3'-0" 7'-0" KD F2 PAINT 1 3/4" W OO D PAINT 3'-0" 7'-0" KD F2 PAINT 1 3/4" W OO D PAINT 3'-0" 7'-0" KD F2 PAINT 3'-4" 7'-2" PAINT HM F5 20 M IN. 3'-4" 7'-2" PAINT HM F5 20 M IN. 20 M IN. 1 3/4" W OO D PAINT 3'-0" 7'-0" KD F2 PAINT W IRE 20 M IN. 1 3/4" W OO D PAINT 3'-0" 7'-0" D4 HM F4 PAINT W IRE W IRE 1 3/4" W OO D PAINT HM F1 PAINT 3'-0" 7'-0" 1 3/4" W OO D PAINT HM F1 PAINT 3'-0" 7'-0" 1 3/4" W OO D PAINT KD F2 PAINT 7'-0" PR. 3'-0" 1 3/4" W OO D PAINT KD F2 PAINT 3'-0" 7'-0" 1 3/4" W OO D PAINT KD F2 PAINT 3'-0" 7'-0" 16'-0" 7'-0" D8 ANO DIZED 16'-0" 7'-0" D8 ANO DIZED DRYW ALL DRYW ALL DRYW ALL FINISH ALL STO REFRONT FRAM ES AND ENTRANCES W ITH HIGH PERFO RM ANCE PAINT COATING - COLO R TO M ATCH EXISTING FINISH ALL WINDOW FRAMES ANDAPPLIED MULLIONS WITH HIGH PERFORMANCEPAINT COATING - COLOR TO MATCH EXISTING D5 PAINTED SOLID CORE W OO D VENEER 6-PANEL DUTCH DOOR PAINTED SOLID CORE W OO D VENEER 6-PANEL DO OR TO PAINTED SOLID CORE W O OD VENEER DOO R W ITH APPLIED TRIM TO M ATCH EXISTING M ATCH EXISTING F3 W ITH W IRE O R TEM PERED KNOCK DO W N FRAM E GLASS SIDELITE TO M ATCH EXISTING D3D3D6D2D2D2D2D3D3D3D2D2D2D4D2D2D2D2D2D2D2 20 M IN. 20 M IN. 20 M IN. 20 M IN. F3F3F3 TEM P. TEM P. W IRE Date EXISTING A107 A107 REVISED 6-20-13 REVISED 6-20-13 REVISED 6-20-13 REVISED 6-20-13 REVISED 6-20-13 REVISED 6-20-13 REVISED 6-20-13 EXISTING REVISED 6-20-13 REVISED 6-20-13 B102 EXISTING B102 REVISED 6-20-13 REVISED 6-20-13 EXISTING 1 3/4" W OO D PAINT 3'-0" 7'-0" KD F2 PAINT D2 B124A B124B REVISED 6-20-13 REVISED 6-20-13 B124A B124B B132A VERIFY B132B B132A B132B B132C REVISED 6-20-13 REVISED 6-20-13 REVISED 6-20-13 W OO D ±12'-8"6'-8"6'-8"EQUAL4"EQUAL±6'-10 5/8"(2 BRICK COURSESLESS THAN EXISTING)SAME AS W1 ±7'-4" (MATCH EXISTING) D2 KD F2 VERIFY 1 3/4" W OO D D2 PAINT EXISTING EXISTING PAINT PAINT 20 M IN. 20 M IN. VERIFY VERIFY 1 3/4" W OO D D2 PAINT 20 M IN. 20 M IN. TEM P. INSULATED G LAZING B141 B140 1 3/4" W OO D PAINT 3'-0" 7'-0" D2 1 3/4" W OO D PAINT 3'-0" 7'-0" D2 PAINT HM F1 20 M IN. PAINT HM F1 20 M IN. B141 B140 B158 20 M IN. 1 3/4" W OO D PAINT 3'-0" 7'-0" KD PAINT B158 D2 F2 B163 B172 B163 B172 1 3/4" W OO D PAINT 3'-0" 7'-0" HM PAINT D2 F3 TEM P. 1 3/4" W OO D PAINT 3'-0" 7'-0" HM PAINT D2 F3 TEM P. D6D6D6 D6 HO LLO W M ETAL (INSULATED CORE AT EXTERIOR CONDITIONS) ±8'-8" 2'-4" ±9'-0" 2'-4" EQ. EQ. EQ. ±16'-0" EQ. EQ. ±10'-4" M ATCH EXISTING ADM INISTRATIO N AREASEE SCHED.2" A B C D E F G H J K L O P R S T U V W X Y Z PIVOTS AND WEATHERSTRIPPING BY DOOR SUPPLIER EXIT DEVICE(S) - RIM WITH REMOVABLE ASTRIGAL, EXIT ONLY EXIT DEVICE - RIM WITH CYLINDER EXIT DEVICE(S) - EXPOSED VERTICAL RODS WITH CYLINDER EXIT DEVICE(S) - FIRE, EXPOSED VERTICAL RODS PASSAGE SET TO MATCH 2001 ADDITION/RENOVATION CLOSURE(S) ACOUSTIC SEALS AND ASTRIGAL A.D.A. SEQUENCED DOOR OPENERS WITH INTERIOR WALL BUTTON AND EXTERIOR BOLLARD BUTTON HOLD-OPEN(S) WALL STOP FLOOR STOP PIVOTS AND PUSH/PULLS BY DOOR SUPPLIER 3 BUTTS/LEAF (4 AT LEAVES OVER 42" WIDE AND AT DUTCH DOORS) ELECTROMAGNETIC LOCKDOWN DEVICE(S) AT HEAD OF OPENING ELECTROMAGNETIC HOLD-OPEN DEVICE(S) ON ADJACENT WALLS TO RELEASE AT LOCKDOWN AA C F T HARDW ARE B011B B011A 1 3/4" W OO D PAINT 3'-0" 7'-0" 1 3/4" W OO D PAINT D2 D2 B011B B011A KD F2 PAINT KD F2 PAINT 3'-0" 7'-0" EXIT DEVICE(S) - CONCEALED VERTICAL RODS WITH CYLINDER EXIT DEVICE - FIRE, RIM WITH CYLINDER ENTRANCE/OFFICE SET TO MATCH 2001 ADDITION/RENOVATION PRIVACY SET TO MATCH 2001 ADDITION/RENOVATION HOSPITAL LATCH E O E O AA E S T E S T AA B E G T E L T E L T E R T E T 90 M IN. O E G T E L T E O AA E H T E H T A E O BBB E G T E G T E O T E O T E J T U E J T U E J T U AA E O T E T R E O T E O T E T P E O T C K T C K T D T X D T X E O T E O T E O E O E O E O E O E O E O E O T E O T A.D.A. THRESHOLD WWW ZZ YYYYYYYYYYYYYYYYYYYYYYYY HARDW ARE NO TES: 1. HARDW ARE GRADE, FINISH, LOCKSET LEVER, AND KEYING TO MATCH 2001 ADDITION/ RENOVATION (SPACES EAST OF CORRIDOR A103). 2. SUBMIT DOORS, FRAMES, AND HARDW ARE PRODUCT DATA FOR APPROVAL. ARRANGE HARDW ARE INTO SETS. ALLOW AT LEAST 2 W EEKS FOR PRO CESSING AND REVIEW BY ARCHITECT. 3. INSTALL PANIC BUTTONS FOR LOCKDOW N SYSTEM AT OFFICE A105, AV BOOTH AT GYMNASIUM A115, PULPIT AT SANCTUARY B136, AV BOOTH AT BALCONY ABOVE SANCTUARY B136, AND RECEPTION B157. CONFIRM EXACT LOCATIONS W ITH OW NER. PROVIDE COMPLETE SYSTEM INCLUDING ELECTROMAGNETIC DEVICES, TRANSFORMERS, CONTROLS, W IRING, ALL INSTALLATIONS, ETC. AT OPENINGS WITH EXIT DEVICES, ELECTROMAGNETIC DEVICE(S) MUST AUTOMATICALLY RELEASE DOOR(S) WHEN PERSONS ARE PRESENT ON THE EXIT DEVICE SIDE. COORDINATE POW ER REQUIREMENTS W ITH ELECTRICAL CONTRACTOR AT TIM E OF BIDDING.