Loading...
HomeMy WebLinkAbout12005_2013-08-09_COVERURTIH 910060 NE STATE OF IS IRET E RG A NAIDD A R C SEG E ONJ W R YEL B RET ISNo. Y ED TCE M Carmel, Indiana 46032 621 South Range Line Road Carmel United M ethodist Church Architectural Cover Sheet S201 Structural Structural Drawings First Floor Dem olition Plan D201 Basem ent and Second Floor Plans A202 M echanical E202 M 001 Basem ent Floor HVAC Plan First Floor Floor Plan Door and Fram e Schedule A501 A201 P201 Plumbing Waste & Vent Plans and Isomectrics Exterior and Interior Elevations A301 P202 Plumbing Domestic Water Plans E201 First Floor Lighting Plan Interior Design I101 First Floor Flooring Plan I102 First Floor Finish Plan E203 Basem ent and Second Floor Power and Fire Alarm Plans G ENERAL PRO JECT NO TES AND REG ULATIO NS. PRIO R TO BEG INNING W O RK. INTERIOR W ALLS; AND TO COLUMN CENTERLINES. CLARIFICATIO NS ARE NEEDED O R DIM ENSIO NAL CO NFLICTS ARE FO UND. TO BIDDING THE PROJECT, AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PLAN DIMENSIONS ARE ACTUAL TO FACE OF MASONRY, FACE OF STUDS, OR SECTION, DETAIL, OR INTERIOR ELEVATION DIMENSIONS ARE ACTUAL TO FACE OF MATERIAL INDICATED, W HICH MAY INCLUDE FACE OF GYPSUM BOARD OR OTHER MATERIAL ON INTERIOR WALLS - (DIFFERS FROM PLAN DIMENSIONS) CO NTRACTOR TO PRO VIDE M ISC. BLO CKING FO R O W NER SUPPLIED FIXTURES DO NO T SCALE DRAW ING S. CO NTACT ARCHITECT IF ADDITIO NAL DIM ENSIO NAL ALL W ORK SHALL BE PERFORMED TO MEET APPLICABLE CODES, ORDINANCES EACH CO NTRACTO R SHALL FULLY REVIEW ALL CO NTRACT DO CUM ENTS PRIO R STOREFRONT FRAMING ON EXTERIOR W ALLS; TO FACE OF STUDS ON AND EQUIPM ENT - COORDINATE W ITH OW NER. BUILDING CO DE INFO RM ATIO N 160 W est Carmel Drive, Suite 240 (317)574-8808 Carmel, Indiana 46032 Structural Engineer 4. TO ILET ACCESSO RY INDICATO R 5. M O RE THAN ONE DOOR O R BO RROW ED LITE OCCURS IN THE SAM E RO OM TO ROO M NUM BERS - A LETTER IS ADDED W HEN DO OR AND BORRO W ED LITE NUM BERS CORRESPOND RO O M NAM E AND NUM BER DO O R NUM BER T1 101A PLAN DETAIL M ARKER O FFICE 102 ELEVATION (HEIGHT) MARK BORROWED LITE (WINDOW) NUMBER: (FIRST FLOOR FINISH FLOOR = 100'-0") BL112 3.2.1. CO LUM N LINE AND NUM BER: 126'-0" TOP OF C.M .U. ELEVATIO N M ARKER: 3 3841 W est M orris Street (317)244-7637 Fax(317)244-6348 Indianapolis, Indiana 46241 T&W Corporation Architect and Site, Plumbing & Electrical Engineer Byrum Architects Design - Build General Contractor SHEET NUMBER (TYPICAL) ON SHEET (TYPICAL) PLAN, ELEVATION, SECTION, OR DETAIL NUMBER SYM BO LS LEG END PLAN, ELEVATION, SECTION, O R DETAIL TITLE: SECTIO N M ARKER SHEET INDEX (765)537-2991 8261 Baseline Road Paragon, Indiana 46166 Hoffman Engineers Inc., P.C. Interior Design Jung Design, Inc. A201 01 SCALE: 1/8" = 1'-0" FLO O R PLAN 01 A202 01 A401 01 A301 DESIG N-BUILD TEAM W ALL TYPE DESIG NATIO N W 31 160 W est Carmel Drive, Suite 240 (317)574-8803 Carmel, Indiana 46032 I103 Basement Flooring Plan I104 Basem ent Finish Plan I105 Ceiling Finish Plans 3409 Sutherland Avenue (317)879-8255 Indianapolis, Infdiana 46218 Mechanical Engineer Design Air Engineering for P.M.C. Additions and Renovations to Basem ent and Second Floor Dem olition Plans D202 Basement and Second Floor Reflected Ceiling Plans A204 First Floor Reflected Ceiling Plan A203 Roof Plan A205 Sections and Details A401 Sections and Details A402 Plumbing & Electrical BUILDING CODE PLAN M 101 First Floor HVAC Plan Project No. Sheet No. Revisions: Drawn By Checked By W CHURCH SOLUTIONS T& BYRU M A R C H ITEC TS required for the proper execution and performance and completion of the require- architectural elements and, in some cases, service for use solely with respect to this These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of building, the major the structural, mechanical, and/or electrical systems. The Drawings do not necessarily indicate or describe all work required for full m ents of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all item s Use of Documents projects or additions to this Project without Project and shall not be used on other Project are instruments of the Architect's documents prepared by the Architect for this The Drawings, Specifications, and other written permission and due compensation to Certified By completion of the work. the Architect. Scope DrawingsT&W Corporation 46241 3841 W . M orris St. Indianapolis, Indiana 621 South Range Line Road, Carmel, Indiana 46032 Carmel United Methodist Church Specially commissioned by T&W Church Solutions, and used under license. 12005 JW B CAD 8-9-13 PROJECT COVER SHEETCover Additions and Renovations to Copyright 2013 C 160 W. Carmel Drive, Suite 240 Carmel, Indiana 46032 317-574-8808 www.byrumarchitects.net Date CO NSTRUCTIO N TYPES: PRO JECT ADDRESS: PRO JECT LO CATIO N: O CCUPANCY G RO UP: CARMEL, HAMILTON COUNTY, INDIANA NO RTH O F EAST 126TH STREET A3V-B (BASEMENT ONLY SPRINKLED) AT PORTIONS OF CARM EL UNITED M ETHO DIST CHURCH 621 SOUTH RANG E LINE RO AD EXISTING BUILDING + PRO PO SED CANO PY AND CO LO NNADE ADDITIO NS W EST O F THE EXISTING 2-HO UR FIRE PARTITIO N AND PRO PO SED FIRE W ALL II-B (FULLY SPRINKLED) AT PORTIONS OF EXISTING BUILDING + PROPO SED RESTRO OM ADDITIO N EAST O F THE EXISTING 2-HO UR FIRE PARTITIO N AND PROPO SED FIRE W ALL EXISTINGCOURTYARD EXISTINGCOURTYARD EXISTING 2-HOUR FIRE PARTITIONPROPOSED STRUCTURALLYINDEPENDENT 2-HOUR FIRE WALLV-B (BASEMENT ONLY SPRINKLED) AT THIS PORTIONOF EXISTING BUILDING + PROPOSED CANOPY ANDCOLONNADE ADDITIONS WEST OF THE EXISTING2-HOUR FIRE PARTITION AND PROPOSED FIRE WALL II-B (FULLY SPRINKLED) AT THIS PORTION OF EXISTING BUILDING + PROPOSED RESTROOM ADDITION EAST O F THE EXISTING 2-HOUR FIRE PARTITION AND PRO PO SED FIRE WALLEXISTINGEXITEXISTINGEXITEXISTINGEXITEXISTINGEXITEXISTINGEXITEXISTINGEXITEXISTINGEXITEXISTINGEXITNEWEXITMODIFIEDEXITALL NEW AND MODIFIED CO RRIDORS AT NON-SPRINKLED (FIRST FLOOR) AREAS OF BUILDING SHALL BE 1-HOUR RATED W TH 20-M INUTE RATED OPENING S RESTRO O M ADDITIO N 752 SF ADDITIO N 1,470 SF CANO PY AND CO LO NNADE TRAVEL DISTANCES TO EXITS ARE NOT INCREASED BY ANY PART OF THE PROPO SED ADDITIO NS OR RENO VATIO NS. TRAVEL DISTANCES TO EXITS ARE ACTUALLY DECREASED BY THIS W O RK. NORTHCOVER01NO SCALE BUILDING CODE PLAN EXISTING AREA (II-B PORTION OF BUILDING) FIRST FLOORSECOND FLOO R TOTAL 13,850 SF 5,690 19,540 SF EXISTING AREA (V-B PORTION OF BUILDING) BASEMENTFIRST FLOOR TOTAL 26,330 SF27,34053,670 SF - TOTAL EXISTING ALL LEVELS: 41,190 SF - ALLOWABLE FIRST FLOOR V-B PORTION: (6,000 SF [TABLE 503]) + (6,000 X 53 [506.2]) = 9,180 SF - ALLOWABLE FIRST FLOOR II-B PORTION: (9,500 SF [TABLE 503]) + (9,500 X 45 [506.2]) + (9,500 X 2 [506.3] - ACTUAL FIRST FLOOR V-B PORTION: 28,810 SF - NO TE: VARIANCE #13-08-32 G RANTED FO R INCREASE BUILDING AREA: IN AREA DUE TO PROPO SED CANO PY & COLONNADE ADDITIO N. = 32,775 SF - ACTUAL FIRST FLOOR II-B PORTION: 14,602 SF NO TE: VARIANCE #13-08-32 G RANTED FO R USE O F EXISTING 2-HO UR FIRE PARTIO N IN LIEU O F FIRE W ALL AS EXISTING BUILDING SEPARATIO N. - TOTAL ADDITIONS: 2,222 SF - TOTAL BUILDING ALL LEVELS: 43,412 SF First Floor Power and Fire Alarm Plan C201 Site/Civil Site Drawings 1 Survey 3 Legal Description E200 Electrical Dem olition Plan I106 Elevations and Details I107 Elevations and Details