HomeMy WebLinkAbout12005_2013-08-09_COVERURTIH
910060
NE STATE OF
IS
IRET
E RG
A NAIDD
A
R
C
SEG
E
ONJ
W
R
YEL
B
RET
ISNo.
Y
ED
TCE M
Carmel, Indiana 46032
621 South Range Line Road
Carmel United M
ethodist Church
Architectural
Cover Sheet
S201
Structural
Structural Drawings
First Floor Dem
olition Plan
D201
Basem
ent and Second Floor Plans
A202
M
echanical
E202
M
001
Basem
ent Floor HVAC Plan
First Floor Floor Plan
Door and Fram
e Schedule
A501
A201
P201
Plumbing Waste & Vent Plans and Isomectrics
Exterior and Interior Elevations
A301
P202
Plumbing Domestic Water Plans
E201
First Floor Lighting Plan
Interior Design
I101
First Floor Flooring Plan
I102
First Floor Finish Plan
E203
Basem
ent and Second Floor Power and Fire Alarm
Plans
G
ENERAL PRO
JECT NO
TES
AND REG
ULATIO
NS.
PRIO
R TO
BEG
INNING
W
O
RK.
INTERIOR W
ALLS; AND TO COLUMN CENTERLINES.
CLARIFICATIO
NS ARE NEEDED O
R DIM
ENSIO
NAL CO
NFLICTS ARE FO
UND.
TO BIDDING THE PROJECT, AND NOTIFY ARCHITECT OF ANY DISCREPANCIES
PLAN DIMENSIONS ARE ACTUAL TO FACE OF MASONRY, FACE OF STUDS, OR
SECTION, DETAIL, OR INTERIOR ELEVATION DIMENSIONS ARE ACTUAL TO FACE
OF MATERIAL INDICATED, W
HICH MAY INCLUDE FACE OF GYPSUM BOARD OR
OTHER MATERIAL ON INTERIOR WALLS - (DIFFERS FROM PLAN DIMENSIONS)
CO
NTRACTOR TO
PRO
VIDE M
ISC. BLO
CKING
FO
R O
W
NER SUPPLIED FIXTURES
DO
NO
T SCALE DRAW
ING
S. CO
NTACT ARCHITECT IF ADDITIO
NAL DIM
ENSIO
NAL
ALL W
ORK SHALL BE PERFORMED TO MEET APPLICABLE CODES, ORDINANCES
EACH CO
NTRACTO
R SHALL FULLY REVIEW
ALL CO
NTRACT DO
CUM
ENTS PRIO
R
STOREFRONT FRAMING ON EXTERIOR W
ALLS; TO FACE OF STUDS ON
AND EQUIPM
ENT - COORDINATE W
ITH OW
NER.
BUILDING
CO
DE INFO
RM
ATIO
N
160 W
est Carmel Drive, Suite 240
(317)574-8808
Carmel, Indiana 46032
Structural Engineer
4.
TO
ILET ACCESSO
RY INDICATO
R
5.
M
O
RE THAN ONE DOOR O
R BO
RROW
ED LITE
OCCURS IN THE SAM
E RO
OM
TO ROO
M
NUM
BERS - A LETTER IS ADDED W
HEN
DO
OR AND BORRO
W
ED LITE NUM
BERS CORRESPOND
RO
O
M
NAM
E AND NUM
BER
DO
O
R NUM
BER
T1
101A
PLAN DETAIL M
ARKER
O
FFICE
102
ELEVATION (HEIGHT) MARK
BORROWED LITE (WINDOW) NUMBER:
(FIRST FLOOR FINISH FLOOR = 100'-0")
BL112
3.2.1.
CO
LUM
N LINE AND NUM
BER:
126'-0"
TOP OF C.M
.U.
ELEVATIO
N M
ARKER:
3
3841 W
est M
orris Street
(317)244-7637 Fax(317)244-6348
Indianapolis, Indiana 46241
T&W
Corporation
Architect and Site, Plumbing & Electrical Engineer
Byrum Architects
Design - Build General Contractor
SHEET NUMBER (TYPICAL)
ON SHEET (TYPICAL)
PLAN, ELEVATION, SECTION, OR DETAIL NUMBER
SYM
BO
LS LEG
END
PLAN, ELEVATION, SECTION,
O
R DETAIL TITLE:
SECTIO
N M
ARKER
SHEET INDEX
(765)537-2991
8261 Baseline Road
Paragon, Indiana 46166
Hoffman Engineers Inc., P.C.
Interior Design
Jung Design, Inc.
A201
01
SCALE: 1/8" = 1'-0"
FLO
O
R PLAN
01
A202
01
A401
01
A301
DESIG
N-BUILD TEAM
W
ALL TYPE DESIG
NATIO
N
W
31
160 W
est Carmel Drive, Suite 240
(317)574-8803
Carmel, Indiana 46032
I103
Basement Flooring Plan
I104
Basem
ent Finish Plan
I105
Ceiling Finish Plans
3409 Sutherland Avenue
(317)879-8255
Indianapolis, Infdiana 46218
Mechanical Engineer
Design Air Engineering for P.M.C.
Additions and Renovations to
Basem
ent and Second Floor Dem
olition Plans
D202
Basement and Second Floor Reflected Ceiling Plans
A204
First Floor Reflected Ceiling Plan
A203
Roof Plan
A205
Sections and Details
A401
Sections and Details
A402
Plumbing & Electrical
BUILDING CODE PLAN
M
101
First Floor HVAC Plan
Project No.
Sheet No.
Revisions:
Drawn By
Checked By
W
CHURCH SOLUTIONS
T&
BYRU
M
A
R
C
H
ITEC
TS
required for the proper execution and
performance and completion of the require-
architectural elements and, in some cases,
service for use solely with respect to this
These drawings indicate the general scope of
the project in terms of architectural design
concept, the dimensions of building, the major
the structural, mechanical, and/or electrical
systems. The Drawings do not necessarily
indicate or describe all work required for full
m
ents of the Contract. On the basis of
the general scope indicated or described, the
trade contractors shall furnish all item
s
Use of Documents
projects or additions to this Project without
Project and shall not be used on other
Project are instruments of the Architect's
documents prepared by the Architect for this
The Drawings, Specifications, and other
written permission and due compensation to
Certified By
completion of the work.
the Architect.
Scope DrawingsT&W Corporation
46241
3841 W
. M
orris St.
Indianapolis, Indiana
621 South Range Line Road, Carmel, Indiana 46032
Carmel United Methodist Church
Specially commissioned by T&W Church Solutions, and used under license.
12005 JW
B
CAD
8-9-13
PROJECT COVER SHEETCover
Additions and Renovations to
Copyright 2013
C
160 W. Carmel Drive, Suite 240
Carmel, Indiana 46032
317-574-8808
www.byrumarchitects.net
Date
CO
NSTRUCTIO
N TYPES:
PRO
JECT ADDRESS:
PRO
JECT LO
CATIO
N:
O
CCUPANCY G
RO
UP:
CARMEL, HAMILTON COUNTY, INDIANA
NO
RTH O
F EAST 126TH STREET
A3V-B (BASEMENT ONLY SPRINKLED) AT PORTIONS OF
CARM
EL UNITED M
ETHO
DIST CHURCH
621 SOUTH RANG
E LINE RO
AD
EXISTING
BUILDING
+ PRO
PO
SED CANO
PY AND
CO
LO
NNADE ADDITIO
NS W
EST O
F THE EXISTING
2-HO
UR FIRE PARTITIO
N AND PRO
PO
SED FIRE W
ALL
II-B (FULLY SPRINKLED) AT PORTIONS OF EXISTING
BUILDING
+ PROPO
SED RESTRO
OM
ADDITIO
N EAST O
F
THE EXISTING
2-HO
UR FIRE PARTITIO
N AND PROPO
SED
FIRE W
ALL
EXISTINGCOURTYARD EXISTINGCOURTYARD EXISTING 2-HOUR FIRE PARTITIONPROPOSED STRUCTURALLYINDEPENDENT 2-HOUR FIRE WALLV-B (BASEMENT ONLY SPRINKLED) AT THIS PORTIONOF EXISTING BUILDING + PROPOSED CANOPY ANDCOLONNADE ADDITIONS WEST OF THE EXISTING2-HOUR FIRE PARTITION AND PROPOSED FIRE WALL II-B (FULLY SPRINKLED) AT THIS PORTION OF EXISTING
BUILDING + PROPOSED RESTROOM ADDITION EAST O
F
THE EXISTING 2-HOUR FIRE PARTITION AND PRO
PO
SED
FIRE WALLEXISTINGEXITEXISTINGEXITEXISTINGEXITEXISTINGEXITEXISTINGEXITEXISTINGEXITEXISTINGEXITEXISTINGEXITNEWEXITMODIFIEDEXITALL NEW AND MODIFIED CO
RRIDORS
AT NON-SPRINKLED (FIRST FLOOR)
AREAS OF BUILDING
SHALL BE
1-HOUR RATED W
TH 20-M
INUTE
RATED OPENING
S
RESTRO
O
M
ADDITIO
N
752 SF
ADDITIO
N
1,470 SF
CANO
PY AND CO
LO
NNADE
TRAVEL DISTANCES TO
EXITS ARE
NOT INCREASED BY ANY PART OF
THE PROPO
SED ADDITIO
NS OR
RENO
VATIO
NS. TRAVEL DISTANCES
TO EXITS ARE ACTUALLY DECREASED
BY THIS W
O
RK.
NORTHCOVER01NO SCALE BUILDING CODE PLAN EXISTING AREA (II-B PORTION OF BUILDING)
FIRST FLOORSECOND FLOO
R
TOTAL
13,850 SF
5,690
19,540 SF
EXISTING AREA (V-B PORTION OF BUILDING)
BASEMENTFIRST FLOOR TOTAL 26,330 SF27,34053,670 SF
- TOTAL EXISTING ALL LEVELS: 41,190 SF
- ALLOWABLE FIRST FLOOR V-B PORTION: (6,000 SF
[TABLE 503]) + (6,000 X 53
[506.2]) = 9,180 SF
- ALLOWABLE FIRST FLOOR II-B PORTION: (9,500 SF
[TABLE 503]) + (9,500 X 45
[506.2]) + (9,500 X 2 [506.3]
- ACTUAL FIRST FLOOR V-B PORTION: 28,810 SF
- NO
TE: VARIANCE #13-08-32 G
RANTED FO
R INCREASE
BUILDING
AREA:
IN AREA DUE TO PROPO
SED CANO
PY & COLONNADE
ADDITIO
N.
= 32,775 SF
- ACTUAL FIRST FLOOR II-B PORTION: 14,602 SF
NO
TE: VARIANCE #13-08-32 G
RANTED FO
R USE O
F
EXISTING
2-HO
UR FIRE PARTIO
N IN LIEU O
F FIRE W
ALL
AS EXISTING
BUILDING
SEPARATIO
N.
- TOTAL ADDITIONS: 2,222 SF
- TOTAL BUILDING ALL LEVELS: 43,412 SF
First Floor Power and Fire Alarm
Plan
C201
Site/Civil
Site Drawings
1
Survey
3
Legal Description
E200
Electrical Dem
olition Plan
I106
Elevations and Details
I107
Elevations and Details