Loading...
HomeMy WebLinkAbout12005_2013-08-09_P201NORTH Project No. Sheet No. Revisions: Drawn By Checked By W CHURCH SOLUTIONS T& BYRU M A R C H ITEC TS required for the proper execution and performance and completion of the require- architectural elements and, in some cases, service for use solely with respect to this These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of building, the major the structural, mechanical, and/or electrical systems. The Drawings do not necessarily indicate or describe all work required for full m ents of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all item s Use of Documents projects or additions to this Project without Project and shall not be used on other Project are instruments of the Architect's documents prepared by the Architect for this The Drawings, Specifications, and other written permission and due compensation to Certified By completion of the work. the Architect. Scope DrawingsT&W Corporation 46241 3841 W . M orris St. Indianapolis, Indiana 621 South Range Line Road, Carmel, Indiana 46032 Carmel United Methodist Church Specially commissioned by T&W Church Solutions, and used under license. 12005 JW B CAD 8-9-13 PLUMBING WASTE & VENT PLANS AND ISOMETRICSP201 P201 01 SCALE: 3/32" = 1'-0" FIRST FLO O R PLUM BING W ASTE & VENT PLAN URTIH 910060 NE STATE OF IS IRET E RG A NAIDD A R C SEG E ONJ W R YEL B RET ISNo. Y ED TCE M Additions and Renovations to Copyright 2013 C 160 W. Carmel Drive, Suite 240 Carmel, Indiana 46032 317-574-8808 www.byrumarchitects.net Date NORTHP20102SCALE: 3/32" = 1'-0" BASEMENT PLUMBING WASTE & VENT PLAN EXISTING 3"EXISTING 3"3"3"WCHLAVHEXISTING1-1/2" VENT 1-1/2" VENTORIGINAL SINK(NOT USED)EXISTING 3" WASTEAND 1-1/2" VENTORIGINAL SINK(NOT USED)EXISTING 4" SANITARYBUILDING DRAIN EXISTINGRESTROOMEXISTING 4" SANITARYBUILDING DRAIN EXISTING 4"EXISTING 4"EXISTING 4" FROMABOVE (SEE 01/P201)EXISTINGRESTROOM W CH W CH CO URUR URH FD FDWC (TYPICAL) FD FD LAV (TYPICAL) CO 4"4"4" 2"2"2" 2"2" 3"3"3"3"4" 2" DO W N BELOW (SEE 02/P201) 2"SK1 2" V.T.R. DW 4" V.T.R. RO OF DRAIN CO NFIRM INVERT EXITING STORM . SLEEVE AT NEW FOO TING S AS NEEDED EXISTING CATCH BASIN EW C2"1-1/4" VENT EX I S T I N G 12 " S T O R M SK1 3" W CH LAVH 2" REM O DELED AS SHOW N ORIGINAL RESTROO M INSTALL P-TRAP AND PLUM B M O P SINK W HERE W .C. REM OVED M S EXISTING 3" W ASTE AND VENT (ROUTE NEW TO EXISTING) SK2 2 "2" EXISTING 2" EXTEND NEW W ASTE FROM WHERE EXISTING SINK REMOVED 1 -1 /4 " V E N T A B O V E RESTROOMB025CAFEB053 EXISTING STORM SEE SHEET P202 PLUM BING G ENERAL NO TES SEE SHEET P202 PLUM BING FIXTURE SCHEDULE P201 03 NO SCALE W O M EN 122 AND M EN 123 W ASTE & VENT ISO M ETRIC 3" 3" 3" 4" 3" 2" 3" 3" 2" 2"2" 2" 4" 3" 2" 2" LAV 2" 2" 2" CO W CH W CH FD FD FD FD UR UR URH LAV LAV LAV LAV LAV W C W C W C W C W C 4 " 4 " 4 " 3 " 3 " 4 " CO EW C THRU ROO F 4" VENT 4 " 2"1-1/4" VENT 4" VENT 2 " V E N T 1-1/2" VENT (TYPICAL) W O M EN A122 M EN A123 W O M EN A122 M EN A123 P201 05NO SCALE CAFE B053 WASTE & VENT ISOMETRIC EXISTING 4" SANITARYBUILDING DRAINKITCHEN B147, RESTROOM B025, AND O FFICE A105 CAFE B146 KITCHEN B147 SK1 EXISTING 3" WASTE & 1-1/2 VENTEXISTING 4"EXISTING 3"EXISTING 3 FD EXISTING 3 FD EXISTING 3" WASTE & 1-1/2 VENTEXISTING 3" WASTE & 1-1/2 VENTLAVHWCH2" ABOVE FROM SK1(SEE 01/P201)1-1/2" VENT1-1/4" VENT3"3"3"2"1-1/2" VENT2"SK1 THRU ROOF 2" VENT2" VENT2"KITCHENB147RESTROOMB025CAFEB053EXISTINGRESTROOM P201 04 NO SCALE O FFICE A105 W ASTE & VENT ISO M ETRIC SK2 PIPING REMOVED FROM ORIGINAL SINK FOR NEW WALL OPENING EXISTING 3"2 " 2" 1-1/4" VENT 1-1/4" VENT CAP EXISTING EXISTING VENT O FFICE A105 EXISTING VENT LO CATIO N RELOCATED EXISTING VENT TO NEARBY W ALL AND RECO NNECT IN ATTIC AS REQUIRED W C W C 4 " I N P L E N U M B E L O W EXISTING 4" DOW N TO BELOW (SEE 02/P201) AND E.W .C. THIS AREA (NOT USED) O RIG INAL RESTRO OM S EXISTING 4" WASTE & VENT EXISTING 4" SANITARY BUILDING DRAIN EXISTING 4" 4" REPLACE TW O EXISTING IM PRO PER FUNCTIO NING W ATER CLOSETS REPLACE FAUCETS, DRAINS, AND P-TRAPS AT TW O EXISTING LAVATO RIES REPLACE EXISTING IM PRO PER FUNCTIONING W ATER CLO SET W C 4" S TO R M E X IS T IN G S T O R M 1,520 350 190 300 150 390240 200 90 300 210280 40 60 9090 200 150 150 60 60 110 240 3,790 1,300 600 110 870 1,300 870 70 110 50 80 130 920 890 610 160 30 20 20 20 540 490 180 30 1010 630 630 280 280 40 630 730 5,480 90 40 40 510 350 570 2040300001,68070 186140 297 728 3737 584 275 148 713 145 164 612160 67 64 80 551 864 2333 1,297 546 551 95 3,589 197 140 372 243 268 172 101 265 223 110 165 195 78 190 562 2 3 4 5 6 7 KJHGFEDC 1 54 93 SS S S S S SS S S S SS SS S S S SS S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S SS S S SS S S S S SS SSSSSSSSSSSSSSSS SSSSS S S S SS S S S S S S S S S S S S S S S S S S SS S S S S S S SSS S3S3S3S3SSSS33EEE EE E E E EEE E E E E E E E E E E E E EE E E E E E E E E E E E E E E EE EE EE E E E E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E EE E E E E E E E E E EE E EE E E E E E E E E E E E E E E E E E E E E E E E EE EEEEEEEEEE EE E E E S S S S F S S S S S SSSSS E S S S S S S S S S SSS S S S S S S S S S S S S S S S SSS SS S S S S S S S E E E S S S S S S S S S S SS S S S S S S SS S S S S SS S S S S S S S S S S S S S S S S SS S3 3 S 3 S S S S 3S S S S S S S S S S3S S SS S S S S S 3