Loading...
HomeMy WebLinkAbout09120027.472 rr�rr�rv�avi� �va�� � DRIVEWAY CONCRETE SLAB: 11'4 12" - MIN. 4" THK. 1" SLOPE - THICKENED TO 51/2 @ GARAGE DOOR o; A n < n -1 - - \ z O p0 Op �O p 0 0 p0 Opp ° ° ° Q p ° < $ 0 (��O°° *4001 � oO oo 0 0 0 ZJ o 0 0 0 m O O O 0 o OU 0Qp Q0 0 �Q°(�0° `h � 1 o O� Up0 (BOO U O V n m 1 I � 11 =1 11 =1 11 =1 11 =1 I I- g o o "'1 111111 e m O II IIII z Iii z d 4 GARAGE SLAB NOTES: 1. 4" CONCRETE SLAB 2. PEA GRAVEL BASE 3. 1 1/2" x 51,4" (2x6) LEDGE FOR DRIVEWAY SLAB SUPPORT 4. WEATHER LIP AT GARAGE DOOR - 1" ADDITIONAL FALL IN LAST 12" OF RUN HVAC * HIGH EFFICIENCY (950% f) GAS FURNACE * ENERGY SAVER POWER VENT WATER HEATER * 13 SEER AIR CONDITIONER * GOODMAN HUMIDIFIER LOCATED ON BASEMENT UNIT NOTE: PROVIDE ADDITIONAL OUTLET FOR POWER VENT a a " 8 "x18" CONCRETE FOOTING 4 a O a z 06 SECTION DETAIL - FOUNDATION a0 GARAGE DOOR SCALE: BRICK VENEER THERMO -PLY SHEATHING FOUNDATION WALL NOTES: - HOLD BTM OF THERMO -PLY BELOW T/ SUBFLOOR BASEMENT FOUNDATION WALLS 1 - W/ APPROVED FASTENER @ 3 "o.C., TYP. VC N V ? BASEMENT FOUNDATION WALLS ARE TO BE 10--thk., N @ ° @ 9' -0 "h. OFF T/ FOOTING. FOOTINGS TO BE 20 "w. 18" WIDE MYLAR COUNTER FLASH'G - HOLD T/ MYLAR : GARAGE FOUNDATION WALLS - 4" OFF T/ SUBFLOOR @ 2x10 JSTS GARAGE FOUNDATION WALLS TO BE 8 "thk. WHERE NOTED - 2" OFF T/ SUBFLOOR @ 2x12 ]STS ON PLAN, 6' -0 "h. OFF T/ FOOTING. FOOTINGS TO BE R -19 BAND BD. INSULATION 18 "w. (UNLESS NOTED ON PRINTS DIFFERENTLY) - CONTINUOUS AIR SPACE, TYPICAL FOUNDATION WATER- PROOFING NOTES: 1. AN APPROVED WATERPROOFING MEMBRANE IS SILL SEALER, TYPICAL REQUIRED FOR ALL EXTERIOR FOUNDATION WALLS THAT ENCLOSE THE BASEMENT AREA & SHALL EXTEND v °/ FROM TOP OF THE FOOTING TO THE FINISHED GRADE. FLASH & SEAL' FLASH'G: - 18" WIDE i a 1 2. JOINTS IN THE MEMBRANE SHALL BE LAPPED & SEALED - SEAL AROUND ALL PENETRATIONS, TYP. ao a WITH AN ADHESIVE COMPATIBLE WITH THE WATERPROOFING MEMBRANE. a BRICK WEEPHOLES FOUNDATION GENERAL NOTES: @ 24" o.c. HORIZONTAL 4" 6^ - W/ WEEP CARDS - 1. PROVIDE CONTROL JOINTS IN SLAB @ ALL BEAM AND COLUMN E's (2) COATS SPRAY - APPLICATION °� AND AS NOTED BITUMINOUS DAMPPROOFING: 2. USE 6 MIL POLY VAPOR BARRIER UNDER BASEMENT - APPLIED TO CURB & BELOW GRADE 10" - REFER TO FOUNDATION PLAN SLAB FOR INFORMATION REGARDING 3. USE PRESSURE - TREATED LUMBER @ ALL PLACES OF WATERPROOFING CONTACT w/ CONCRETE 5 DETAIL - 8 "d. FOUNDATION BRICK CURB KENTUCKY ONLY: 4. (2) #4 STEEL RE- INFORCEMENT BARS IN THE TOP AND SCALE: 1 1/2" = 1' -0" BOTTOM OF FOUNDATION WALL AND (2) #4 "RE BARS" IN FOOTING 4" CONCRETE SLAB ON GRADE D m m N ° 0 A °oo O o oQ 0o o o 0 p0o O u 0 ° eO a o ° o o ® o o° o oe ea o o o o�o$ 40 � co o�� o e ° � 0 $ UNDISTURBED SOIL PEA GRAVEL BASE @ ° ° Q e o og° " o ° o0 oBQo ° a�� o o o° o o a° o o p8�. a °o0o ° o o °o of o o�aOo UNDISTURBED SOIL o ,� a ° ° Is 0040 %(3, fie° APPROXIMATE LINE OF o0 0 00 0 3' -0" OVERDIG 04SECTION DETAIL - GARAGE SLAB SCALE: 3/4" = V -0" 3" PVC PIPE: - THRU ROOF 3114" THICK CONCRETE SLAB 57 Q 6 MIL POLY VAPOR BARRIER m C' o ° o �Qg 0 N � • � QP�• ��° • O� � o LU_... MINIMUM 4" GRAVEL BASE O PVC "T' IN GRAVEL a BASE: - NOTE: RUN PARALLEL TO FOOTING 03SECTION DETAIL - RADON REDUCTION SCALE: 1x2 RIPPED @ 300 TO 3/4" = V -0" FORM CONTROL JOINT RIP 1x2 AS ETAILED OR NOTCH FORMING 0 •0£ FISCHER HOMES RADON REDUCTION SYSTEM NOTES: THE FOLLOWING ITEMS ARE TO BE INSTALLED AS PART OF FISCHER HOMES RADON REDUCTION SYSTEM: 1. A UNIFORM LAYER OF CLEAN AGGREGATE AT A MINIMUM OF 4 INCHES UNDER THE CONCRETE SLAB. 2. A 6 MIL POLYETHYLENE OR EQUIVALENT FLEXIBLE SHEETING MATERIAL SHALL BE PLACED ON TOP OF THE GRAVEL. THE SHEETING SHALL FIT CLOSELY AROUND ANY PIPE, WIRE, OR OTHER PENETRATIONS OF THE MATERIAL. ALL PUNCTURES OR TEARS IN MATERIALS SHALL BE SEALED OR COVERED WITH ADDITIONAL SHEETING. 3. A 3 INCH DIAMETER PVC PLUMBING TEE SHALL BE EMBEDDED VERTIC- ALLY INTO THE SUB -SLAB AGGREGATE AND THROUGH THE SHEETING BEFORE THE SLAB IS POURED. THE PIPE SHALL BE EXTENDED UP THROUGH THE BUILDING FLOORS AND TERMINATE AT LEAST 12 INCHES ABOVE THE SURFACE OF THE ROOF IN A LOCATION 10 FEET AWAY FROM ANY WINDOW OR OTHER OPENINGS INTO THE CONDITIONED SPACES OF THE BUILDING THAT IS LESS THAN 2 FEET BELOW THE EXHAUST POINT. NOTE: ALL FITTINGS ARE TO GLUED AND SECURED AS NEEDED. IN ADDITION, FISCHER HOMES WILL PROVIDE APPROXIMATELY 6 FEET OF VERTICAL DISTANCE WHERE THE VENT PASSES THROUGH THE ATTIC FOR POSSIBLE INSTALLATION OF A FUTURE EXHAUST FAN. 4. PLUMBER AND HVAC SUBCONTRACTOR TO COORDINATE THE INSTALLA- TION OF THE RADON EXHAUST PIPE IN THE HVAC CHASE AREA. RESIDENTIAL ENERGY CODE COMPLIANCE: ■ %" THERMAX RIGID INSULATION (R -3.3) - 4' -0 "d. - CONTINUOUS El %" THERMAX RIGID INSULATION (R -3.3) - 4' -0 "d. and 8' -0 "d. - PER GRADE CONDITIONS ❑ 5/8" THERMAX RIGID INSULATION (R -4) - 4' -0 "d. - CONTINUOUS ❑ 5 THERMAX RIGID INSULATION (R -4) - 4' -0 "d. and 8' -0 "d. - PER GRADE CONDITIONS ❑ 3/4" THERMAX RIGID INSULATION (R -5) - 4' -0 "d. - CONTINUOUS El 3/4" THERMAX RIGID INSULATION (R -5) - 4' -0 "d. and 8' -0 "d. - PER GRADE CONDITIONS 1" THERMAX RIGID INSULATION (R -6.5) - 4' -0 "d. - CONTINUOUS ❑ 1" THERMAX RIGID INSULATION (R -6.5) - 4' -0 "d. and 8' -0 "d. - PER GRADE CONDITIONS ❑ 1 %" THERMAX RIGID INSULATION (R -9.8) - 4' -0 "d. - CONTINUOUS ❑ 1 %" THERMAX RIGID INSULATION (R -9.8) - 4' -0 "d. and 8' -0 "d. - PER GRADE CONDITIONS R -15 HIGH - DENSITY BATT INSULATION w/ KRAFT FACE ❑ VAPOR BARRIER TO WARM SIDE IN ALL EXTERIOR FRAME WALLS and GARAGE COMMON WALL. R -44 BLOWN WOOL or FIBERGLASS INSULATION ❑ w/ BAFFLES EVERY TRUSS SPACE ** NOTE: THERMAX INSULATION TO WRAP THE INSIDE PERIMETER OF FOUNDATION WALLS. 3 �J" THICK CONCRETE SLAB BEARING FRAME WALL P.T. SOLE R (4) RE -BARS: TIE WIRE \ - w/ 2" MIN. COVER P ° I ° FA ° w 00000 000 pFz m o� O 2 EA _ a 11" x 16" THICKENED 16" c� SLAB O � L VINYL WATER -STOP: VAPOR BARRIER z CAST -IN -PLACE - TIED TO RE -BAR O CONCRETE FOUNDATION W PLAN DTL - VERTICAL CONTROL JOINT 7 DETAIL - THICKENED SLAB SCALE: 3 4" = 1' -0" ■ SCALE: / U) 0 m u v O y o U v m m of U '! Y U Ln m 0 N m = 1' -0• OP v M N 18' -3%" 20' -1" 68' -0" OVERALL (16" BRICK CURB) 5' -6" 9' -1 %" - - - - - - - - - LINE OF DECK ABOVE \ - - - - - - - - - - - - - - - - - - 18' O3 /all �I 9,_Ol /4„ 8'-6�,. 8'-1�q" I w I 1 w I z 24" 0 PIERS LU - SET ON SOLID GROUND (UNEXCAVATED) 5040SL EGRESS 24' -1 �" 24' -3 %a , 15' -0" STONE TYPE WINDOW WELL w/ DRAIN A/C A/C CAL VERTI / a J LT --� CONTROL POCKET NTROL I I J _ 3" fd STEEL COLUMN in JOINT I WET BAR I I 5 JACK STUDS - - - - - No ROUGH -IN / 4" 0 STEEL COLUMN IF a-�4 FINISH A9L BASEMENT w/ STEEL PLATE ON T/ _ z 31 /2 "w•x8 "x1 /z "thk. o 4. I z 36" x 36" x 12 "d. CAST -IN -PLACE ONLYO FLOG NG. 1 ' I (o CONCRETE COLUMN FOOTINGS: Io SEE FRAME DETAIL 04/A6.0 2'-314" 3' -1" T -6" J z 3' 2 13' 0 %z" - - HOLD TOP DOWN 3114" BELOW I0 m ° BELOW FINISHED FLOOR LINE z _ 32"x 32" x 12 "d. CAST -IN -PLA C Fi E N O CONCRETE COLUMN FOOTINGS: w Ip z B SEMENT 1 I° U') • 1 1 O - HOLD TOP DOWN 3 �J" BELOW I .. _ BELOW FINISHED FLOOR LINE 3" PJ SCH. 40 STEEL PIPE COLUMN 1 / ' Oz WOOD HANDRAIL - - -ONE SIDE / I ~ 51" x 51" x 15 "d. CAST -IN -PLACE I 110V SMOKE A .a M I�� J I I I I CONCRETE COLUMN FOOTINGS: / 'r DETECTOR - - - r - -n ti I� - I I - HOLD TOP DOWN 3 � BELOW / WOOD GUARDRAIL BELOW FINISHED FLOOR LINE i ' - - - -BOTH SIDES I � 1 -- I M I II Iu I I i`' I r- y - -- CONC3RETE COLUMN CAST-IN-PLACE II MI BI I I I I I N 1" I - HOLD TOP DOWN 3 /J BELOW �- _LL _ 11 I I- - � W 8 x -STEEL BEAM _ �� - - I � - - - - - I i BELOW FINISHED FLOOR LINE N vi 11 _ I + - I - - - - - - 7 I I I � ��� � � � I FULL BATH I 1 1 3" 0 it GA. ADJUSTABLE 4 "x 10 "x s" d IIII �j I �� I ROUGH -IN L - + - J STEEL COLUMNS CD I BEAM POCKET I I NOTE.. POWER PROVIDE OUTLET VENT HIGH 5� 5' 0" 3� 1 - 4 "x 8 "x 7/8" d. _ _ EFFICIENCY r - BEAM POCKET EXHAUST &INTAKE FOR WATER HEATER _ - - - - - - - - - - - - - - - - - - - - - - - - - - - 1- - 2' -8%2„ p W 8 x 24 STEEL BEAM co Q �- - \ ------ - - -rFD P m \ I n = =1 0 1 ( o.-- -- 3" 0 PVC RADON- - REDUCTION PIPE w I 14' -4.. 1, 3.. 1. 0., \4'10 N 6'-9" L - J l0" TO 4 OF COLUMN 0 z TO ti OF COLUMN I I / C TO L OF COLUMN P s z I U ��1 z U-1 1 O O -- -- J J I 30" x 30" x 12 "d. CAST -IN -PLACE F J I^ w CONCRETE COLUMN FOOTINGS: NOTE!! ce I0 CO 9,-03 /a" M =� m � oI - HOLD TOP DOWN 31f2" BELOW PROVIDE OUTLET I z 32" x 32" x 12"d. CAST -IN -PLACE Iz O O J I BELOW FINISHED FLOOR LINE Uj FOR SUMP PUMP I� OE3NCRETE COLUMN FOOTINGS: O z OI BATTERY BACK UP 'HOLD T/ OF FOOTING DOWN IU Ln z ce I '311" FOR SLAB POUR I 4 "x 8" x 8 %8 "d. v 0 I HOLD T/ GARAGE SLAB o - pp DOWN 2" FROM T/ FDN. yL l� j �Y W ° SLOPE TO O.H. DOORS I j C? ¢ SET BELOW FROST DEPTH MIN. 32" ( ) 6x6 POST ABOVE I �z Q i I / / HOLD DOWN 22 FROM T/ OF FOUNDATION Io - �� I Q U I8' BRICK CURB O - w/ #4 REBAR @ 18" o. O= (@ 8" thk. WALLS ONLY) Z LU Z W CONTROL JOINT I N 2: M < J �0 I I ELL 1 E-i 0 Z w LU U 3U) 0 z I Mzg< I I a� =� � i I _jOZ= in / U0 F- 116" HOLD DOWN WALL 12" w I 16" BRICK CURB FROM TOP OF SLAB LDETAIL 06/A2.0 1 - J. � Z BRICK CURB ;