HomeMy WebLinkAbout09120027.260 SECTION - HARDIPANEL w/ ROOF BELOW
7SCALE: 3" = 1' -0"
NAILING PATTERN NOTE:
2" x 6d GALVANIZED NAILS TO BE 6" o.c. ON
PERIMETER and 12" o.c. IN THE FIELD
- KEEP FASTENERS 2" AWAY FROM CORNERS
& 3/" MIN. FROM EDGE OF PANEL
HARDIPANEL,
- HOLD OFF T,
1 /g" THERMO -P
'Z' FLASHING
- DO NOT OVE
- BUTT ENDS
FRAME WALL
SECTI _
0 HARDIPANEL
8SCALE:
Q
rn
0
rn
0
0
N
M
N
w
H
Q
0
O
J
a
O
J
a
O
w
z
O
U)
a
w
HORIZONTAL SEAM
6" = V -0"
HARDIPANEL, TYPICAL
- HOLD OFF T/ TRIM i /a"
METAL DRIP FLASHING
- SET IN BED OF SEALANT
- NAIL & CAULK TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
ix TRIM BOARD
- HOLD TRIM UP 1" f
- REFER TO ELEVATIONS FOR SIZES AND
PROFILES
2" x 3" METAL DRIP FLASHING, TYP. -
- W/ 1" HEM
- NAIL & CAULK TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
NOTE:
HEM OF FLASHING MUST FASTEN ONE
PIECE TO THE OTHER. (HORIZONTALLY)
2%4" x 5" LIMESTONE SILL, TYP. —�
- PULL BTM. 1 "f _
- SLOPE %4" MIN.
� M
,Yh
„f
BRICK VENEER, TYPICAL
SECTION - HARDIPANEL 0 LIMESTONE SILL
w/ lx TRIM - B ICK VENEER
SCALE: 3" = 1' -0"
HARDIPANEL, TYPICAL
- HOLD OFF T/ TRIM %4"
METAL DRIP FLASHING
- SET IN BED OF SEALANT
- NAIL & CAULK TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
ix TRIM BOARD
- HOLD TRIM UP 1" f
- REFER TO ELEVATIONS FOR SIZES AND
PROFILES
11/" x 3" METAL DRIP FLASHING, TYP.
- W/ 1" HEM
- NAIL & CAULK TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
NOTE: z
HEM OF FLASHING MUST FASTEN ONE
PIECE TO THE OTHER. (HORIZONTALLY)
21/4" x 21/" LIMESTONE SILL,
- PULL BTM. 3 /,,±
- SLOPE 1/4" MIN.
'Y~
11h
CULTURED STONE VENEER, TYPICAL "
SECTION - HARDIPANEL 0 LIMESTONE SILL
w/ lx TRIM - CLTLTURED STONE VENEER
05SCALE: 3" = 1' -0"
HARDIPANEL, TYPICAL -
- HOLD OFF T/ TRIM 1/4"
METAL DRIP FLASHING
- SET IN BED OF SEALANT
- NAIL & CAULK TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
ix TRIM BOARD
- HOLD TRIM UP 1" t
- REFER TO ELEVATIONS FOR SIZES
AND PROFILES
METAL FLASHING, TYP.
- NAIL & CAULK TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
ROOF PITCH VARIES
- REFER TO PLANS
0 SECTION - HARDIPANEL w/ lx TRIM w/ ROOF BELOW
SCALE: 3" = 1' 0"
HARDIPANEL, TYPICAL
- HOLD OFF T/ SILL 1
2" x 3" METAL DRIP FL,
- W/ 1" HEM
- NAIL & CAULK TO SHI
- USE 1" ROOFING NAI
NOTE:
HEM OF FLASHING M
PIECE TO THE OTHEF
2%4" x 5" LIMESTONE S
- PULL BTM. 1 "t
- SLOPE 1/4" MIN.
BRICK VENEER, TYPICAL
SECTION - HARDIPANEL LIMESTONE SILL
0 1 - BRICK VENEE
SCALE: 3" = 1' -0"
HARDIPANEL, TYPICAL
- HOLD OFF T/ SILL 1 "3
11/" x 3" METAL DRIP F
- W/ 1" HEM
- NAIL & CAULK TO SHI
- USE 1" ROOFING NAI
NOTE:
HEM OF FLASHING M
PIECE TO THE OTHEF
21/4" x 21/2" LIMESTONE
- PULL BTM. 3/4 "f
- SLOPE 1/4" MIN.
CULTURED STONE VENEER, TYPICAL
SECTION - HARDIPANEL LIMESTONE SILL
- CULTURED STONE VENEER
SCALE: 3" = 1' -0"
H -STRIP CONNECTOR OR BATTEN,
TYP.
- REFER TO PLANS FOR LOCATIONS
FIBERGLASS ASPHALT SHINGLES
OVER 7/16" ROOF SHEATHING -
METAL FLASHING
- TURN OUT 3" ABOVE GUTTER
HARDIPANEL, TYP.
- NOTCH HARDIPANEL FOR
FLASHING
- HOLD OFF T/ SHINGLES 1 "t
ALUMINUM GUTTER -
- REFER TO ELEVATIONS
1x8 GUTTER BOARD, TYP.
Z/�
0 DETAIL - GABLE FLASHING @ HARDIPANEL
3SCALE:
3" = V -0"
U
J
u')
w
z
O
J
C;'
>�
O
v-4
M
00
w
z
ci
C
In
0
m
k
W
L
W
0
U
J Lu
O
U
O
2
O
I
O
f
O
W Q
-
w of }
—i
Q Z
Q W
CLI N
n
J pY0,
O
W
W
O
zOJ�
U
w
O�
Z
a W
(!) w=
w
F- Z 0
Q
Lu
0aX
z
w_ =ern
Lr)
c9�
C7
,�,
u-
�i
pF�
W ...
�
d J
W
V
9
ZOp
u- ry U a
LL
OU Q
O
d
IA
oC
O
� Q oc
Lu
U
I
z
� 0
W
QO �
1 !
O I 1
0
>
LL. (°jw Or-
o- z�
V/
cl�
W
O Z
az
DC oz
O
CL a� ^ v
Sheet No.
D4.1
Job No.
LRE- 14 I
i
(j) N
Lu CO
Q o
v-
ZZ
W Q
-
~ 0 2�
i� C5
Q Z
Q W
Sheet No.
D4.1
Job No.
LRE- 14 I
(j) N
Lu CO
Q o
W Q
W z
Q Z
Q W
CLI N
n
L QD a
Z U
O
J
a W
F- Z 0
Lu
0aX
=aw O
LLJ
CL
0
Lu
U
W
w
0
>
V/
cl�
W
z Q
Lu
w
°o
w
z
2:
o �r
Sheet No.
D4.1
Job No.
LRE- 14 I