ELECTRICAL NOTES 1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN. THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THE PLACEMENT OF DENTAL EQUIPMENT, THEY ARE NOT INTENDED FOR CONSTRUCTION. 32 2, EXACT EQUIPMENT LOCATIONS MUST BE JOB 51TE VERIFIED BY THE HENRY ® 25 (I SCHEIN DENTAL EQUIPMENT SPECIALIST. FUTURE 3. FOLLOW MANUFACTURER'S DRAWINGS FOR EXACT REQUIREMENTS FOR QUID ANY EQUIPMENT SUPPLIED BY HENRY SCHEIN DENTAL. CONSULT WITH HENRY TREATMENT SCHEIN DENTAL REP FOR ADDITIONAL INFORMATION. MECHANICAL (;L d -Yx (� 3 4. GFCI PROTECTION OR REDUNDANT GROUND IN DENTAL CHAIR RECEPTACLES, DENTAL UTILITY CABINETS AND ANY OTHER AREAS REQUIRED BY LOCAL CODE IS THE RESPONSIBILITY Of THE ELECTRICAL CONTRACTOR. t - l LAUNDRY \ 5. ADDITIONAL CONVENIENCE OUTLETS REQUIRED ON JOBSITE ARE THE P4 RESPONSIBILITY OF ELECTRICAL CONTRACTORS. FOLLOW LOCAL CODE Ak RESTRICTIONS. G. ALL COMPUTER NETWORKING AND WORKSTATIONS MUST BE SPECIFIED BY J CUSTOMERS COMPUTER SUPPLIER. HrNRY SCHEIN DENTAL IS NOT C I I RESPONSIBLE FOR OFFICE COMPUTER NETWORK SITE PREPARATION OR STAFF INSTALLATION. LOUNGE ELECTRICAL LEGEND w 0 It �UTURE $ NEW DUPLEX OUTLET. HEIGHT TO BE SPECIFIED ON -SITE TREATMENT UNLESS NOTED OTHERWISE. �) #4 A 1 - _ 0 NEW ETHERNET JACK LOCATION. HEIGHT TO BE SPECIFIED Q W _ ON -SITE UNLESS NOTED OTHERWISE. FUTURE NEW ETHERNET JACK LOCATION FOR VIDEO. HEIGHT TO BE Z PANORAMIC TREATMENT SPECIFIED ON -51TE UNLESS NOTED OTHERWISE. tt� I J y o #3 . NEW TELEPHONE JACK LOCATION. HEIGHT TO BE SPECIFIED Q , ON -SITE UNLESS NOTED OTHERWISE. y Q -... �I z 16 ...... _......__ __.. PC �91) 9D l�J� r a6 77vcc Q NEW TELEPHONE/DATA JAr_K LOCATION. HEIGHT TO BE »» J SPECIFIED ON -51TE UNLESS NOTED OTHERWISE. Z STERILIZATION / NEW TELEPHONE/DATA/DUPLEX OUTLET LOCATION. HEIGHT TO 23 LAB I I � z BE SPECIFIED ON -SITE UNLESS NOTED OTHERWISE. U Q O w © NEW CATV JACK LOCATION. HEIGHT TO BE SPECIFIED ON -SITE OO O UNLESS NOTED OTHERWISE. 14 _...._. _...® 34 15 PC NEW PC LOCATION. REQUIREMENTS TO BE PROVIDED BY SUPPLIER. HENRY 5CHEIN REP: 9 TREATMENT MARK WETHINGTON #2 1 CENTER: ' SEE SHEETS SPE.3 � SPE.4 FOR ILLUSTRATIONS � DETAILS INDIANAPOLIS, IN QUIET 1 9D� 3 PHONE #: TREATMENT PC i (600) G45-G594 PC I Azi 0 %I O z c Q O = Q w cn U U O ° w � llL � III 9 �WZ° TREATMENT O o = n = I #I W PC w = `n 0 O U I- _...... � z z w o LLJ II C3 O �o LL LLJ 0 LL-1 Pc z z o U- 0 F �D L�0 - F ... : J z Q W z Lu _ � Lu J O PRIVATE \ 0 Q OW U �° Q m LL O (n OFFICE / Z 0 � Lu � 0 CONSULTATION z oz Q w ° � Lq j W O L W Q Z � Q 0 CL Z C z c� o L 0 w iLi _ CZ ° Z U ° °- U W vo cz o Q o Ile SERVER / CPC ° Lu D O STORAGE I I = z D �( f Q 'II ' DRAWING NAME: NEAL -2D PROJECT START DATE: 23 BUSINESS 07/1 G/2009 OFFICE DETAIL START DATE: 0911412009 DRAWN BY: JBK DETAILED BY: JBK g C ( CHECKED BY: - -- `,1 1 \ \ REVISIONS: I' -- / - - / -- - -- PATIENT / - - / -- LOUNGE INT.5Q.FT.= 2 1 98 S.F. GAMING STATIONS C SCALE: 5HT. SIZE: 1/4 1 ' -0" D ELEC�TG°�OC L [PLAN FROF05ED DENTAL ELECTRICAL 5FECIEICATION5 p IF= 0 2 © 2009 by HENRY 5CHEIN DENTAL ELECTRICAL 5FECI f ICATIONS PLEASE NOTE: ALL REQUIREMENTS TO BE VERIFIED BY MANUFACTURER'S SPEC � o SHEETS PROVIDED BY HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. Q � Q MANUFACTURER'S SPECS SUPERSEDE ANY AND ALL INFORMATION CONTAINED � � � z J w HEREIN. � w � o Q o w cW � � oC W U D O m ~ z UCH � ��w z � Q U U> O U z �, DESCRIPTION wo � o o UTILITY CENTER @ 1 2:00 CABINET -VALVE STOPS TO BE SUPPLIED AND INSTALLED BY 6 3 CONTRACTOR. BACK FLOW PREVENTION REQUIRED AS PER LOCAL CODE. • 115V, 20A 3 6 3 IUTILITY CENTER -VALVE STOPS TO BE SUPPLIED AND INSTALLED BY CONTRACTOR. BACK f LOW PREVENTION REQUIRED AS PER LOCAL CODE. • 115V, 20A 3 6 4A 2" EMPTY CONDUIT -PIPE CHASE WITH PULL -WIRE TO BE SUPPLIED AND INSTALLED BY ELECTRICIAN. 6 6 DENTAL LIGHT (TRACK) - REQUIRES MOUNTING SUPPORT. • 115V, AMPS 6 TL VARY 4 9 INTRAORAL X -RAY (SELF- CONTAINED) - REQUIRES A MECHANICAL GROUND AND MOUNTING • 115V, 20A • WD2 SUPPORT. PANORAMIC AND /OR CEPHALOMETRIC XRAY/ CONE BEAM UNIT - REQUIRES A MECHANICAL I I OV, 20A I 9C • OR 220V, • WD7 GROUND. 20A X -RAY REMOTED MOMENTARY CONTACT EXPOSURE BUTTON - SUPPLIED BY HENRY SCHEIN 7 9D DENTAL, INSTALLED BY ELECTRICIAN. ELECTRICIAN TO SUPPLY AND INSTALL LOW VOLTAGE • 9D WIRING. CONNECT WIRES TO X -RAY MASTER CONTROL PER MFG. SPECS. STERILIZER (STATIM) - SWITCHED OUTLET RECOMMENDED, ESPECIALLY IF UNIT IS MOUNTED 115V OR 14 I 14 INSIDE CABINET. • 220V, 15A • I 14A STERILIZER (AUTO- CLAVE) • 115V, 20A • 14A STERI- CENTER UTILITIES -STERI - CENTER SUPPLIED AND INSTALLED BY HENRY SCHEIN SEE MFG. 14C I 14C DENTAL. CONTRACTOR TO INSTALL REQUIRED UTILITY HOOKUPS PER MFG. SPECS. • SPECS • I 15 ULTRASONIC CLEANER • 115V, 15A • 15 I 16 MODEL TRIMMER - PLUMBER TO INSTALL CHROME ANGLE STOP WITH I/4" COPPER FPT • 115V, 15A 16 OUTLET. BACK FLOW PREVENTION PER CODE. 3 23 EXHAUST FAN - SUPPLIED AND INSTALLED BY CONTRACTOR. MAY REQUIRE A SWITCH • 115V, 15A • DEPENDING ON APPLICATION. VENT TO OUTSIDE. EXHAUST FAN FOR DENTAL MECHANICAL CLOSET - SUPPLIED AND INSTALLED BY ELECTRICIAN. A THERMOSTATIC CONTROLLED LOW SONS FAN IS REQUIRED TO KEEP ROOM I 23A TEMPERATURE WITHIN THE EQUIPMENT MANUFACTURER'S RECOMMENDED OPERATING • 115V, 20A TEMPERATURE RANGE. VENT TO OUTSIDE. I 25 AIR COMPRESSOR W /DRYER - I/2" I.D. COPPER TUBING. BUCK - BOOSTER MAY BE . 220V,20A • • • 25 REQUIRED. FRESH AIR INTAKE VENT SUPPLIED BY CONTRACTOR. VACUUM SYSTEM (DRY) - I - I/2" OR 2" MAIN TRUNK LINES. USE PVC OR ABS PIPES WITH 2 - 220V, I 27B LONG TURN FITTINGS. DRAINS AND OUTSIDE -VENTS REQUIRED. HENRY SCHEIN DENTAL TO • AMPS VARY • • • 27B SUPPLY BUCK - BOOSTER IF REQUIRED. I 30A WATER SOLENOID W /FILTER - SUPPLIED BY HENRY SCHEIN DENTAL. INSTALLED BY PLUMBER • 115V, 15A • . 30A ON COLD WATER LINE WITH A VALVE ON BOTH SIDES. (FOR DENTAL EQUIPMENT ONLY). REMOTE PANEL (AIR, WATER, � VAC) - SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLED BY 32 I 32 CONTRACTOR 60" A.F.F. CONTRACTOR TO SUPPLY AND INSTALL LOW VOLTAGE WIRING. • • NITROUS OXIDE � OXYGEN MANIFOLD SYSTEM - SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLED BY PLUMBER. REQUIRES L OR K COPPER LINES, SILVER SOLDERED TO TRUNK 115V, I .5A 33, I 33 LINES RUNNING TO EACH TREATMENT ROOM. PRESSURE TESTED WITH DRY NITROGEN TO • DRAW N20 150 PSI FOR 24 HOURS BY PLUMBER. NITROUS OXIDE � OXYGEN ALARM SYSTEM - SUPPLIED BY HENRY SCHEIN DENTAL, I 34 INSTALLED BY ELECTRICIAN. ELECTRICIAN TO SUPPLY AND INSTALL LOW VOLTAGE WIRING. . 115V • 34 LOCATION PER HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST � CONFIRMED BY DOCTOR. WALL BLOCKING FOR MONITOR MOUNT -SEE CUSTOMER AND HENRY SCHEIN DENTAL SEE MFG. 39A 4 39A EQUIPMENT SPECIALIST FOR EXACT LOCATION. • SPECS WASHER � DRYER - CONTRACTOR TO SUPPLY AND INSTALL UTILITIES FOR OWNER SUPPLIED 115V OR I 45 APPLIANCES. (NATURAL GAS OPTION IF REQUIRED FOR DRYER). • 220V, AMPS • VARY