Loading...
HomeMy WebLinkAbout09100098.501 REFLECTED CEILING PLAN SCALE: 1/4 " =1' -0" REFLECTED CEILING LEGEND NOT IN CONTRACT DENOTES NEW 2'X 2' ACOUSTICAL TEGULAR CEILING GRID/TILE ® DENOTES NEW 2'X 4' RECESSED FLUORESCENT FIXTURE DENOTES NEW RECESSED CAN LIGHT DENOTES NEW DIRECTIONAL RECESSED CAN LIGHT DENOTES NEW DECORATIVE WALL SCONCE - LIGHTINGUNIVERSE.COM, JUSTICE DESIGN, 1 ALR -8858 ALABASTER ROCKS, PART #: 3577656, MOUNT CENTER OF LIGHT FIXTURE 5' -8" A.F.F. I-O DENOTES NEW DECORATIVE WALL SCONCE - LIGHTING UNIVERSE.COM, WESTIN HOUSE, 2 6789 BATHROOM LIGHT, BRUSHED NICKEL, PART #: 2282362, 2 LIGHTSINSTALL AS UP- LIGHTS ODENOTES NEW DECORATIVE CEILING LIGHT - LIGHTINGUNIVERSE.COM, JUSTICE DESIGN, 1 FAL -971, LUMEN ARIA SEMI FLUSH CEILING LIGHT, PART # 3584593,18" DIA, BRUSHED NICKEL, FAUX ALABASTER GLASS. ODENOTES NEW DECORATIVE PENDANT LIGHT - LIGHTINGUNIVERSE.COM, JUSTICE DESIGN, 2 ALR- 8815 -1, ALABASTER ROCKS! MINI PENDANT, PART #: 3559558, CYLANDER WITH FLAT RIM, BRUSHED NICKEL, BLACK CORD. o DENOTES NEW TRACK LIGHT - PROVIDED BY DENTAL EQUIPMENT CONSULTANT. c — — DENOTES NEW FLUORESCENT COVE LIGHT, OVERLAP ENDS OF TUBES. ® DENOTES NEW EXHAUST FAN WITH LIGHT KIT ® DENOTES NEW EMERGENCY EXIT SIGN DENOTES NEW EMERGENCY LIGHT DENOTES LIGHT SWITCH $D DENOTES LIGHT SWITCH WITH DIMMER REFLECTED CEILING PLAN KEYNOTES 01 CEILING IN THIS LOCATION TO BE 10' -0" A.F.F. F62] CEILING IN THIS LOCATION TO BE 8' -6" A.F.F. 03 CEILING IN THIS LOCATION TO BE 9' -0" 04 FACE OF BULKHEAD TO RECIEVE WC1. 05 REFER TO DENTAL EQUIPMENT CONSULTANTS PLANS FOR BLOCKING REQUIREMENS IN CEILING. 06 CENTER PENDANT OVER TABLE, COORDINATE WITH TENANT. GENERAL REFLECTED CEILING PLAN NOTES A PAINT NEW GYPSUM BOARD BULKHEADS CEILING WHITE, UNLESS NOTED OTHERWISE. B REMOVE EXISTING SWITCHES THAT ARE NOT RE -USED. REMOVE CONDUIT AND WIRING BACK TO NEAREST BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH. C THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK. D CEILING HEIGHT THROUGHOUT THE SPACE IS 9' -0" A.F.F., UNLESS NOTED OTHERWISE. E EXISTING CEILING GRID AND ACOUSTICAL TILE TO REMAIN, UNLESS NOTED OTHERWISE. CONTRACTOR TO REMOVE AND REPLACE ANY EXISTING CEILING TILES AND CEILING GRID THAT IS BROKEN, CHIPPED, OR PUNCTURED WITH NEW TO MATCH EXISTING. F ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH T -9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. G EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN CEILING TILE, UNLESS NOTED OTHERWISE. H COLOR OF LIGHT SWITCH DEVICES AND COVERPLATE TO BE CREAM, UNLESS NOTED OTHERWISE. I ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE DEVICE COVERPLATE. J REFER TO ENGINEERING DOCUMENTS FOR INFORMATION, LOCATION AND SPECIFICATIONS ON EXIT SIGNAGE, LIFE SAFETY SYSTEMS, 24 HOUR EMERGENCY LIGHTING, VENTILATION, HVAC SYSTEMS, CIRCUITING OF LIGHTS AND THERMOSTAT LOCATION ETC. K THERMOSTATS SHALL BE LOCATED DIRECTLY ABOVE OR ADJACENT TO LIGHT SWITCH. ALL THERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE PLACEMENT. L SUPPLY AND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE WHITE IN COLOR. REFER TO ENGINEERING DOCUMENTS FOR ADDITIONAL INFORMATION. M ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE. N IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE DESIGNER PRIOR TO INSTALLATION. 0 VERIFY ALL SPRINKLER HEAD LOCATIONS. NOTIFY DESIGNER IF ANY DISCREPANCIES OCCUR. GENERAL MECHANICAL NOTES A RELOCATE EXISTING DIFFUSERS AND RETURNS AS REQUIRED. DES 501 pennsylN suite 160 indianapolis, ph 317.573.. fx 317.573.. www. mitschd 1 I Q W Z W �V F— LL V♦ L Z) 0 c 0�W t t 0 Z ` t No. STAT U) Ir od o z 0}0U H w� W� w� 0 0 0¢ N o W ww O225 w a N�� °ZOmJw w co 3 =U5 Qa > gof�o�L w a0 nv, of L'i gLL' w w zcn LLa � = ° >mww Q wma >O� O 0 W, O LL n Z zaa o QwwwOw O o� =JZW O �a0¢�v QWZT w O DWG SCALE: DRAWN BY: CHECKED BY: MD PROJECT #: REFLE CEILINC 12( 1 )cn I G N 'ania pkwy indiana 46280 ?222 ?230 alsign.com . • • • • • . • • • • • nN co ]O t� Da 7 Q C Z nU 1 • • • • • 184 OF P, • • • • • • • • • 1/8"=l'-O" KC/AR SS 09162 . . TED PLAN pro milil 1 )cn I G N 'ania pkwy indiana 46280 ?222 ?230 alsign.com . • • • • • . • • • • • nN co ]O t� Da 7 Q C Z nU 1 • • • • • 184 OF P, • • • • • • • • • 1/8"=l'-O" KC/AR SS 09162 . . TED PLAN pro