HomeMy WebLinkAboutC.402 Courtyard Grading Plan0
U
N
O
0
0
I
0
0-
0
U
Ld
U
of
tD
LO
O
O
0
w
N
Z
ILQ
J
_J
V)
0
Z
3
Q
0
rn
(o
L0
O
O
0
N
o.
LLi
J
c�
z
a
0
J
Ll-
L_
W
V)
m
0
LIJ
0
w
n
r')
O
I
n
o
w
r`
L�
LLi w
J
Ln
aQ
0 Ln
z0
� J
0_ 0_
SOUTHEAST
COURTYARD
EXISTING TOPOGRAPHY LEGEND
i
Beehive Inlet
w
Fire Hydrant
®
Curb Inlet
j`
Sprinkler Valve
Q
Lid
O
Stand Pipe
0
Guard Post
a
Buried Electric Line
QS
Sanitary Manhole
t
Buried Telephone Line
�-
Sign
w
Buried Water Line
CHK'D BY:
Coniferous Tree
tr
Top Of Rim Elevation
1
Tree Stump
inv
Invert Elevation
Deciduous Tree
rcp
Reinforced Concrete Pipe
(
Electric Box
vcp
Clay Pipe
4(
Ground Light
cpp
Corrugated Plastic Pipe
Light Pole
pvc
Plastic Pipe
®
Transformer
®
Telephone Handhole
QT
Telephone Manhole
T
Telephone Marker
Telephone Pedestal
PROPOSED
M.E.
EP
BC
TC
000
TC 000.50
BC 000.00
000.00
ADING LEGEND
MATCH EXISTING
EDGE OF PAVEMENT
BOTTOM OF CURB
TOP OF CURB
CONTOURS
FLOW LINE
CURB ELEVATIONS
SPOT ELEVATIONS
•
1. ALL WORK TO CONFORM TO STATE AND LOCAL REGULATIONS.
2. SITE GRADING SHALL RQJ PROCEED UNTIL EROSION CONTROL MEASURES HAVE BEEN INSTALLED.
3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS (VERTICAL AND HORIZONTAL) IN THE FIELD PRIOR TO
STARTING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS. IF
ANY DISCREPANCIES ARE FOUND IN THESE PLANS FROM THE ACTUAL FIELD CONDITIONS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY.
4. THE EXCAVATING CONTRACTOR MUST TAKE PARTICULAR CARE WHEN EXCAVATING IN AND AROUND
EXISTING UTILITY LINES AND EQUIPMENT. VERIFY COVER REQUIREMENTS BY UTILITY CONTRACTOR'S
AND /OR UTILITY COMPANIES SO AS NOT TO CAUSE DAMAGE.
5. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES 72 HOURS BEFORE CONSTRUCTION IS TO
START, TO VERIFY IF ANY UTILITIES ARE PRESENT ON SITE. ALL VERIFICATIONS (location, size and
depth ) SHALL BE MADE BY THE APPROPRIATE UTILITY COMPANIES. WHEN EXCAVATING AROUND OR
OVER EXISTING UTILITIES, THE CONTRACTOR MUST NOTIFY THE UTILITY COMPANY SO A
REPRESENTATIVE OF THAT UTILITY COMPANY CAN BE PRESENT TO INSTRUCT AND OBSERVE DURING
CONSTRUCTION.
6. TRENCHES FOR ALL STORM DRAIN LINES SHALL BE BACKFILLED COMPLETELY WITH GRANULAR
MATERIAL IF WITHIN 5 FEET OF PAVEMENT.
7. AFTER STRIPPING TOPSOIL MATERIAL, PROOFROLL WITH A MEDIUM WEIGHT ROLLER TO DETERMINE
LOCATIONS OF ANY POCKETS OF UNSUITABLE MATERIAL. THE NECESSITY FOR SUBDRAINS AND /OR
REMOVAL OF ANY UNSUITABLE MATERIAL WITHIN THE PROPOSED PARKING AREAS WILL BE DETERMINED
AT THE TIME OF CONSTRUCTION.
CITY OF CARMEL DEPARTMENT OF ENGINEERING NOTES:
1. ALL WORK IN THE PUBLIC RIGHT -OF -WAY SHALL CONFORM TO CURRENT CITY OF CARMEL STANDARDS.
ALL STREETS AND WATER MAINS ARE TO BE CONSTRUCTED TO CARMEL STANDARD SPECIFICATIONS. ALL
STORM SEWERS SHALL BE CONSTRUCTED TO CITY OF CARMEL AND HAMILTON COUNTY STANDARDS. CONTACT
THE APPROPRIATE AGENCIES FOR ADDITIONAL INFORMATION AND /OR DETAILS.
2. ALL PAVING WITHIN THE EXISTING AND PROPOSED RIGHT -OF -WAY SHALL CONFORM TO THE REQUIREMENTS
OF THE DEPARTMENT OF ENGINEERING. CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO
SCHEDULE A PRE - CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS,
STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK, AND TO
REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN ANY EXISTING OR PROPOSED
CITY RIGHT -OF -WAY.
3. ALL PAVING IS TO BE COMPLETED WITHIN THE SAME PAVING SEASON.
8. PROVIDE POSITIVE DRAINAGE WITHOUT PONDING, IN ALL AREAS. AFTER INSTALLATION, CONTRACTOR TO
TEST FOR, AND CORRECT, IF ANY, STANDING WATER CONDITIONS.
9. ALL PROPOSED SPOT ELEVATIONS ARE THE FINAL PAVEMENT AND FINAL GRADE ELEVATIONS.
10. SEE APPROPRIATE DETAILS TO DETERMINE SUBGRADE ELEVATIONS BELOW FINISH GRADE ELEVATIONS
INDICATED.
11. ALL STORM SEWER MATERIALS AND INSTALLATION SHALL CONFORM TO LOCAL STANDARDS.
12. INVERTS AT PIPE OUTLETS ARE GIVEN AT END OF PIPE END SECTION.
13. DEBRIS GUARD TO BE INSTALLED AT ALL OPEN ENDED INLETS.
14. DUE TO SITE CONSTRAINTS, THE EARTHWORK FOR THE SITE AS DESIGNED MAY OR MAY NOT BALANCE.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW THE EXISTING CONDITIONS AND INCLUDE IN THEIR
BID ALL EARTHWORK COSTS INCLUDING IMPORTS AND /OR EXPORTS NECESSARY TO MAKE THE SITE
BALANCE.
15. THIS LOT DOES NOT LIE WITHIN ANY FLOOD HAZARD ZONE AS SCALED FROM THE FLOOD INSURANCE
RATE MAP (FIRM) FOR HAMILTON COUNTY, INDIANA, COMMUNITY 180081, CITY OF CARMEL, PANEL
NUMBER 0209G, DATED JANUARY 29, 2010.
0 10 20'
SCALE: 1"=10'
0' 10' 20'
!%666"
SCALE: 1 " =10'
BENCH INFORMATION
('88 datum)
BM 839
BRONZE DISK SET IN THE TOP OF THE NE CORNER OF A
CONC. SWITCH BASE; 8 INCHES BELOW THE LEVEL OF THE
RAILROAD TRACKS; 2 YARDS EAST OF THE EAST RAIL; 7
RAILS SOUTH OF 111TH STREET, 10 RAILS NORTH OF THE
CROSSING OF THE INDIANA RAILROAD; 11.5 RAILS NORTH OF
MILE POST B 170; 2 MILES SOUTH OF THE STATION ALONG
THE RAILROAD.
STAMPED "Y 42 1934 ".
ELEV = 838.62
ACE TBM 50 CHISELED SQUARE E. SIDE LIGHT POLE CONC
BASE 250'± S. OF N.E. CORNER SITE AND 30'± E. OF EAST
ELEV = 845.34
ASI TBM 80
CHISELED SQUARE ON NORTH SIDE LIGHT POLE BASE; ±300'
EAST OF PENNSYLVANIA STREET ON SOUTH SIDE JOHN KIRK
FURNITURE BUILDING.
ELEV = 857.65
ASI TBM 81
CHISELED "X" ON EAST BOLT FIRE HYDRANT ON WEST SIDE
PENNSYLVANIA STREET IN FRONT OF ADDRESS: 12065; EAST
MOST OF TWO FIRE HYDRANTS.
ELEV = 860.20
1. CONTRACTOR SHALL PROTECT AND NOT DESTROY
THE PROPERTY CORNER MONUMENTS DURING
CONSTRUCTION.
2. CONTRACTOR TO VERIFY LOCATION, SIZE AND
DEPTH OF EXISTING UTILITIES PRIOR TO
COMMENCING ANY CONSTRUCTION. CONTACT
ENGINEER IF VARIATION EXISTS.
CAUTION !!
THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND
EVIDENCE ( including, but not limited to, manholes,
inlets, valves, and marks made upon the ground by
others ) AND ARE SPECULATIVE IN NATURE. THERE MAY
ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR
WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR
WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE
EXACT LOCATIONS OF SAID EXISTING UNDERGROUND
UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR
TO ANY AND ALL CONSTRUCTION.
1- 800 - 382 -5544
CALL TOLL FREE
INDIANA UNDERGROUND -
0 O N U
H (6 �
(n N 0 d
Z Z M v
LU
o :� In
0
U) ED
O Z LO
o¢r-
F_ Z LO
�:
co
J
W
H
U
Z
Ia.
Ljj
cc
i
Z♦,
v
U
a i
W
NONE
JQ►,`� JG�
G
CERTIFIED BY
J
W
2
a
LL V
QF J
N
Ww
W W w
rya o
0aZ .m
N;