HomeMy WebLinkAbout05100025-Site Plan~?.-82~-7200 )'AX
Plot Plan Prepared Fac. R.H. of
Lot # lg4 , containing 13,234 $.F.+,
anytime
AMA
= 20'
Note: Sanitary Sewer
Top of Costing Information
Upstream Uonhde, TC=919.44-
Dbwnstrenm Manhole, TC=919,47
per record drawing
Informotio~
Note: ]he garage finished floor elevation
is 2.9' above the on~o at the drive, per plan.
Ground Cover Calculations:
Drive = 1,197~:E
Public Walk =514 SF:E
Private Walk='=215 SF+
N~lroseeding=~4. 732 SF±
from
Rear of residence.
.S:~d,~alk to bo pieced /
1 fram property line,
lt' from bod~ of curb,
per p~an.
TC~919.47
RECORD
DRA~NG
Note:
This druwlng is bused on construction Cons or record drawings,
and is not boesd upon o field survey, The Sc~nblder Corperotinr
does not warrant the accuracy or sufficiency of this information.
Contractors should verify existing conditions prior to any
construction. Any discrepancy found on this drawing should be
repotted to The Schneider Corporation immediately, failing to do
so results in the contractors oesumption of all liabgity.
Note: The basement efevetion, depicted hereon, has been
informot~ about fluctuotin9 water table~ soil condlfinon, or
types has bees prodded ar stated on auld plans, tie recommended
t,hot ~ besement finished floor devotions be at lecot two feet (2')
snore me normal ponl elevation of any odJolnhg bodies of water,
unless o study of facts reveals otherwise, tf during the excovetion
process any ground water is wlthes~d, The ,Schneider Corporation
shoutd be notified mmediatdy, The basement elevation should be
raised two feet (2) above th~ ground water, and add tk~ol
construction techniques should be incarparoted to ~eviate future
Vb05.0041294
Lot # 194
Assumed North
Scale: t' = 30'
Detail of G~ound/Storm
W~ter flow pettem for
indMd~al lots.
1( Note: Builder to ~sure positive
drainage away from structure{s),
Note: Sump pump(s) to be
pieced by builder as needed.
~ote: Par Carmel zoning ordinance 2fi,1.1 t The
residential distr~t limits I~dght to twenty,five
feet (2§'). however o I~*/elling may be increased
in. height to thirt),-flve feet (3§') provided the
s~de and rear yards om increased an additional
one font ti') far each one foot 0') the
structure exceeds the first twenty-five feet
(25') in height.
The contractor is to mohtoln a minimum
distance of te~ feet (10') between the
sanitary sewer and water he laterals.
CUe8
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
~nap scale uncertainty aha to any other uncertain y in location or elevation on me referenced flood
~nsurance rate map. ALL of the w~t~in described land DOES NOT ~ie within that special flood hazarc
zone AE as said lana plots by scale on flood insurance rate map ~180081 0205 F for the City of
Carmel, indiana dated February t9. 2003.
FLOOD HAZARD STATEMENT
CERllFICAllON
~ 2-,.*'0,.2L~- kl.,
$0303 }
'/I/lllllllllllllll~(~\\\\\'~