Loading...
HomeMy WebLinkAboutCOMcheck Lighting Report.pdfProject Title: Carmel Senior Living Report date: 07/11/13 Data filename: Z:\13\13.128\Design\13.128 Spectrum Carmel - Lighting.cckPage 1 of 6 COMcheck Software Version 3.9.2 Interior Lighting Compliance Certificate 2009 IECC Section 1: Project Information Project Type: New Construction Project Title : Carmel Senior Living Construction Site:Owner/Agent:Designer/Contractor: Carmel, INMichael Longfellow Spectrum Retirement Communities, LLC 200 Spruce Street, #200 Denver, CO 80230 303-360-8812 mlongfellow@spectrumretirement.com Kirk Gastinger Gastinger Walker Harden Architects 817 Wyandotte Kansas City, MO 64105 816 421 8200 kgastinger@designwithinsight.com Section 2: Interior Lighting and Power Calculation A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B x C) COMMON SPACES (Dormitory)50465150465 Total Allowed Watts =50465 Section 3: Interior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) COMMON SPACES ( Dormitory 50465 sq.ft.) Linear Fluorescent 1: A: WILLIAMS DI SERIES: 24" T8 17W: Electronic:2196346664 Linear Fluorescent 1A: A1: WILLIAMS DI SERIES: 48" T8 32W: Electronic:216641024 Linear Fluorescent 1B: A2: WILLIAMS DI SERIES: 48" T8 32W: Electronic:3596480 Compact Fluorescent 1: B: WILLIAMS PV60: Triple 4-pin 32W: Electronic:1267328544 Compact Fluorescent 2: B1: WILLIAMS PV60 WW: Triple 4-pin 32W: Electronic:11032320 Compact Fluorescent 3: B2: WILLIAMS PV60 SS: Triple 4-pin 32W: Electronic:1832256 Linear Fluorescent 2: C: WILLIAMS ASM SERIES: 48" T8 32W: Electronic:236642304 Linear Fluorescent 3: D: WILLIAMS SERIES 21: 48" T8 32W: Electronic:222641408 Linear Fluorescent 4: F: WILLIAMS SERIES 77: 48" T8 32W: Electronic:245642880 Linear Fluorescent 5: F1: WILLIAMS SERIES 22 2': 24" T8 17W: Electronic:223468 Linear Fluorescent 6: G: WILLIAMS SERIES 50: 48" T8 32W: Electronic:325962400 Linear Fluorescent 6A: G1: WILLIAMS SERIES 50: 48" T8 32W: Electronic:21064640 Linear Fluorescent 7: G2: WILLIAMS SERIES 50 22: 24" T8 17W: Electronic:3351153 Linear Fluorescent 7A: G3: WILLIAMS SERIES 50 22: 24" T8 17W: Electronic:213434 Compact Fluorescent 4: H: WILLIAMS PH75: Triple 4-pin 42W: Electronic:214841176 Compact Fluorescent 5: H1: WILLIAMS PH75: Triple 4-pin 32W: Electronic:2964576 Track lighting 1: K: LSI LN30: Wattage based on total luminaires00500500 Linear Fluorescent 8: L: WILLIAMS SERIES 29: 48" T8 32W: Electronic:242642688 Incandescent 1: O1: KICHLER 8405: Incandescent 60W:24120480 Compact Fluorescent 6: O2: AM. FL. LANCET: Quad 2-pin 13W: Magnetic:250261300 Incandescent 2: O3: CANDELLA C169: Incandescent 40W:61240240 Incandescent 3: O4: CANDELLA C169: Incandescent 60W:61360360 Incandescent 4: O5: KICHLER 3677: Incandescent 60W:4402409600 Incandescent 5: O6: MINKA-LAVERY: Incandescent 60W:11560900 Project Title: Carmel Senior Living Report date: 07/11/13 Data filename: Z:\13\13.128\Design\13.128 Spectrum Carmel - Lighting.cckPage 2 of 6 Incandescent 8: O7: KICHLER 3475: Incandescent 100W:19100900 Linear Fluorescent 9: P: WILLIAMS SERIES 16: 24" T8 17W: Electronic:3251102 Incandescent 9: Q: PROGRESS P2781: Incandescent 60W:3101801800 Incandescent 7: W: HUBBELL VAPORTITE: Incandescent 150W:13150450 Total Proposed Watts =48247 Section 4: Requirements Checklist Interior Lighting PASSES: Design 4% better than code. Lighting Wattage: ❑1.Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 50465 48247 YES Controls, Switching, and Wiring: ❑2.Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to vertical fenestration. ❑3.Daylight zones have individual lighting controls independent from that of the general area lighting. Exceptions: ❑Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device. ❑Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a separate switch for general area lighting. ❑4.Independent controls for each space (switch/occupancy sensor). Exceptions: ❑Areas designated as security or emergency areas that must be continuously illuminated. ❑Lighting in stairways or corridors that are elements of the means of egress. ❑5.Master switch at entry to hotel/motel guest room. ❑6.Individual dwelling units separately metered. ❑7.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. ❑8.Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either controlling all luminaires, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switching the middle lamp luminaires independently of other lamps, or switching each luminaire or each lamp. Exceptions: ❑Only one luminaire in space. ❑An occupant-sensing device controls the area. ❑The area is a corridor, storeroom, restroom, public lobby or sleeping unit. ❑Areas that use less than 0.6 Watts/sq.ft. ❑9.Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: ❑Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security. ❑10.Photocell/astronomical time switch on exterior lights. Exceptions: ❑Lighting intended for 24 hour use. ❑11.Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts). Exceptions: ❑Electronic high-frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2009 IECC requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checklist. Project Title: Carmel Senior Living Report date: 07/11/13 Data filename: Z:\13\13.128\Design\13.128 Spectrum Carmel - Lighting.cckPage 3 of 6 Name - TitleSignatureDate Kevin Zimmerman - Principal 7/11/13 Project Title: Carmel Senior Living Report date: 07/11/13 Data filename: Z:\13\13.128\Design\13.128 Spectrum Carmel - Lighting.cckPage 4 of 6 COMcheck Software Version 3.9.2 Exterior Lighting Compliance Certificate 2009 IECC Section 1: Project Information Project Type: New Construction Project Title : Carmel Senior Living Exterior Lighting Zone: 3 (Other) Construction Site:Owner/Agent:Designer/Contractor: Carmel, INMichael Longfellow Spectrum Retirement Communities, LLC 200 Spruce Street, #200 Denver, CO 80230 303-360-8812 mlongfellow@spectrumretirement.com Kirk Gastinger Gastinger Walker Harden Architects 817 Wyandotte Kansas City, MO 64105 816 421 8200 kgastinger@designwithinsight.com Section 2: Exterior Lighting Area/Surface Power Calculation A Exterior Area/Surface B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B x C) F Proposed Watts Front Entrance (Entry canopy)1400 ft20.4Yes560585 Total of 16 Doors - (11) 3'-0", and (5) 6'-0" (Other door (not main entry)) 63 ft of door width20Yes12601629 Memory Care Garden (Plaza area)4100 ft20.16Yes656380 AL Entrance (Entry canopy)188 ft20.4Yes75253 Rear Patio (Plaza area)2750 ft20.16Yes440680 Sky Deck (Plaza area)670 ft20.16Yes107294 Front, East Parking (Parking area)49780 ft20.1Yes49783920 NW Parking (Parking area)3125 ft20.1Yes313275 West Parking (Parking area)5610 ft20.1Yes561275 Main Entrance, SW Drive (Driveway)5950 ft20.1Yes595550 West Drive (Driveway)4440 ft20.1Yes444550 NW Drive (Driveway)6525 ft20.1Yes653550 Garden Path (Walkway < 10 feet wide)500 ft of walkway length0.8Yes400910 Total Tradable Watts* =1104110851 Total Allowed Watts =11041 Total Allowed Supplemental Watts** =750 * Wattage tradeoffs are only allowed between tradable areas/surfaces. ** A supplemental allowance equal to 750 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Section 3: Exterior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) Front Entrance ( Entry canopy 1400 ft2): Tradable Wattage HID 2: U: WILLIAMS MH75: Metal Halide: Standard:14125500 HID 3: Y: AAL SCSQ: Metal Halide: Standard:118585 Total of 16 Doors - (11) 3'-0", and (5) 6'-0" ( Other door (not main entry) 63 ft of door width): Tradable Wattage HID 4: R: INVUE ENV SERIES: Metal Halide: Pulse start:191251125 Compact Fluorescent 1: H2: WILLIAMS H75 SERIES: Quad 4-pin 42W: Electronic:2684504 Project Title: Carmel Senior Living Report date: 07/11/13 Data filename: Z:\13\13.128\Design\13.128 Spectrum Carmel - Lighting.cckPage 5 of 6 Memory Care Garden ( Plaza area 4100 ft2): Tradable Wattage HID 4: R: INVUE ENV SERIES: Metal Halide: Pulse start:11125125 HID 5: S: TERON FAZIO: Metal Halide: Standard:1385255 AL Entrance ( Entry canopy 188 ft2): Tradable Wattage HID 3: Y: AAL SCSQ: Metal Halide: Standard:118585 Compact Fluorescent 1: Quad 4-pin 42W: Electronic:2284168 Rear Patio ( Plaza area 2750 ft2): Tradable Wattage HID 5: S: TERON FAZIO: Metal Halide: Standard:1885680 Sky Deck ( Plaza area 670 ft2): Tradable Wattage HID 5: S: TERON FAZIO: Metal Halide: Standard:1385255 Compact Fluorescent 3: T: BEGA STEP LIGHT: Twin Tube 13W: Electronic:131339 Front, East Parking ( Parking area 49780 ft2): Tradable Wattage HID 9: S1, S1A: Spaulding CR1: Metal Halide: Pulse start:164252550 HID 9b: S1B: Spaulding CR1: Metal Halide: Pulse start:11275275 HID 9c: S1C: Spaulding CR1: Metal Halide: Pulse start:21900900 HID 11: S2: Kim CFL: Metal Halide: Pulse start:1365195 NW Parking ( Parking area 3125 ft2): Tradable Wattage HID 9b: S1B: Spaulding CR1: Metal Halide: Pulse start:11275275 West Parking ( Parking area 5610 ft2): Tradable Wattage HID 9b: S1B: Spaulding CR1: Metal Halide: Pulse start:11275275 Main Entrance, SW Drive ( Driveway 5950 ft2): Tradable Wattage HID 9b: S1B: Spaulding CR1: Metal Halide: Pulse start:12275550 West Drive ( Driveway 4440 ft2): Tradable Wattage HID 9b: S1B: Spaulding CR1: Metal Halide: Pulse start:12275550 NW Drive ( Driveway 6525 ft2): Tradable Wattage HID 9b: S1B: Spaulding CR1: Metal Halide: Pulse start:12275550 Garden Path ( Walkway < 10 feet wide 500 ft of walkway length): Tradable Wattage HID 13: S3: Kim CB32: Metal Halide: Pulse start:11465910 Total Tradable Proposed Watts =10851 Section 4: Requirements Checklist Lighting Wattage: ❑1.Within each non-tradable area/surface, total proposed watts must be less than or equal to total allowed watts. Across all tradable areas/surfaces, total proposed watts must be less than or equal to total allowed watts. Compliance:Passes. Controls, Switching, and Wiring: ❑2.All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt lighting. ❑3.Lighting not designated for dusk-to-dawn operation is controlled by either a a photosensor (with time switch), or an astronomical time switch. ❑4.Lighting designated for dusk-to-dawn operation is controlled by an astronomical time switch or photosensor. ❑5.All time switches are capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. Exterior Lighting Efficacy: ❑6.All exterior building grounds luminaires that operate at greater than 100W have minimum efficacy of 60 lumen/watt. Exceptions: ❑Lighting that has been claimed as exempt and is identified as such in Section 3 table above. ❑Lighting that is specifically designated as required by a health or life safety statue, ordinance, or regulation. ❑Emergency lighting that is automatically off during normal building operation. ❑Lighting that is controlled by motion sensor. Section 5: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2009 IECC requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checklist. Project Title: Carmel Senior Living Report date: 07/11/13 Data filename: Z:\13\13.128\Design\13.128 Spectrum Carmel - Lighting.cckPage 6 of 6 Name - TitleSignatureDate Kevin Zimmerman - Principal 7/11/13