Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A102 REFLECTED CEILING_ELECTRICAL PLAN.PDF
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CA R M E L C I T Y C E N T E R - B U I L D I N G A 72 0 S . R A N G E L I N E R O A D UN I T 7 0 3 C A R M E L , I N 4 6 0 3 2 COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date #CAD Technician #Architect PEDCOR DESIGN GROUP LLC #Pln A102 REFLECTED CEILING/ ELECTRICAL PLAN ##/##/#### THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL ANDUNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013JAMES R. STUTZMAN, AIA, Carmel, Indiana. #Project Status Th u r s d a y , A p r i l 1 8 , 2 0 1 3 ; A L L D A T A : M S : D E S I G N : P R O J E C T S : C A R M E L C I T Y C E N T E R : C C C D r a w i n g s : C C C C o n s t r u c t i o n D o c : B u i l d i n g A : A . 5 0 0 : P E N T H O U S E C D s : P e n t h o u s e T e n a n t s : U N I T - 7 0 3 C U R R E N T : 7 0 3 . p l n E R 28 22 16 H 11 SCALE: NTS PLAN NORTH KEY PLAN PHASE 1, BLDG A SD SD CL EQ.EQ. EQ . 4' - 4 " EQ . 1'- 6 " 1' - 6 " 2'- 9 " EQ.EQ. 3'-11 1/2"EQ 1'- 6 " 1'- 6 " EQ 7'- 8 " EQ 4'-0"4'-0" 4' - 0 " 4' - 0 " 4'-0"4'-0" 4' - 0 " 4' - 0 " 10'-4" 4'-0"4'-0" 4' - 0 " 4' - 0 " 4'-0"4'-0" 4' - 0 " 4' - 0 " 17 ' - 0 7 / 8 " 2'-0"5'-0"2'-7" 2'-0" 5'-0"2'-7" 2' - 4 3 / 4 " 3'- 5 1 / 8 " 2'- 3 3 / 4 " 1'-3 3/8" 2' - 0 " 2'- 0 " 3' - 0 " 2' - 0 " EQ.EQ. 7'-10 1/4"3'-0 1/8"1'-11 3/8" 2'-7 1/4"4'-0"1'-11 3/8" EQ . EQ . E Q . E Q . 4'-0" 16'-0 7/8" 4'-0"4'-0" 4'- 0 " 4'- 0 " 4'-0"4'-0" 4'- 0 " 4'- 0 " 13'-2 3/4" EQ . EQ .EQ.4'-0"EQ. EQ 5'-0"5'-0"EQ EQ.EQ 2' - 0 " 1' - 5 " 2'-0 3/4" 1' - 1 1 7 / 8 " 3' - 4 " 4'-3 5/8"4'-0"4'-0"4'-0" 4'-4 1/2"2'-1 3/4"2'-1 3/4"2'-1 3/4"4'-2 1/2" 7'- 8 " 9'-6"9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" 135° CP1 DIM. DIM. DIM. DIM. DIM.DIM. DIM. CP1 CP1 CP1 CP1 CP1 CP1 CP2 CP3 C C C C C C C I-1 D D D J J J J C C C C C C D D D D D D D D D D D D DD D D F D D D D D I-1 D D D D F E E E E D DD LIVING ROOM KITCHEN ENTRY PANTRY MECH. LAUNDRY DINING ROOM CLOSET MASTER CLOSET 1 MASTER CLOSET 2 MASTER BATH MASTER BEDROOM GUEST BEDROOM GUEST CLOSET GUEST BATH TOILET TERRACE TERRACE DD D D D A A A A Q RQ.2 Q.5 22 21.9 21.5 21.4 21 GENERAL CEILING NOTES: ALL WALLS GO TO FINISHED CEILING UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 1. 3. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS.4. 2.CEILING HEIGHT DESIGNATED BY BENCHMARK ABOVE STRUCTURAL SLAB (ASF). CEILING PLAN NOTES: PAINTED DRYWALL CEILING THROUGH OUT UNLESS OTHERWISE NOTED. CP1 SEE REFLECTED CEILING LEGEND FOR LIGHT SPECIFICATIONS. ADJUST THE HEIGHT OF EXISTING FIRE SUPPRESSION LINES, ROOF DRAIN LEADERS, ROOF STACK VENTS AND CONDENSATE LINES TO ALLOW FOR CEILING HEGHTS AS INDICATED ON THE REFLECTED CEILING PLAN. 5. REPLACE GAS LINE W/ APPROVED ASSEMBLY ALLOWED IN CONCEALED AREAS.6. 7. 8. IF A LIGHT FIXTURE IS NOT DIMENSIONED, IT IS LOCATED IN THE MIDDLE OF THE WALL SEGMENT IT LAYS ON. 8. CROWN MOULDING. REF. 3/A103 FOR DETAILS. CP2 CONTROL JOINT. POP-UP CLERESTORY WITH 4 WINDOWS- DRYWALL RETURN AT ALL CLERESTORY WINDOW OPENINGS. REF. TO 5/A103 FOR TYP. DETAILSCP3 SD DIM. OPEN CEILING HEIGHT. LIVING SPACE CEILINGS. SERVICE PANEL. AREA OF GAS LINE REFLECTED CEILING LEGEND: 4" RECESSED DOWNLIGHT FIXTURE. WET LOCATION EXHAUST FAN FIXTURE. FIRE ALARM STROBE AND SPEAKER. FIRE ALARM SMOKE DETECTOR. DIMMER A C D E F I-1 J SURFACE MOUNTED FIXTURE TO BE: SEAGULL 75435-962, BRUSHEDNICKEL/ SATIN ETCHED SHADE. MINI PENDANT FIXTURE TO BE: PROGRESS P5065, BRUSHED NICKEL. MOUNT AT 6'-6" AFF TO BOTTOM OF FIXTURE. SCONCE TO BE: CRATE & BARREL 639306, BRUSHED NICKEL.MOUNT AT 6' AFF TO CENTER OF J-BOX. SHOWER LIGHT TO BE: COOPER, HALO, ML 706827-H750T-493SC06 RECESSED DOWN LIGHT. CHANDELIER TO BE: PROGRESS P3827-126, EQUINOX CHANDEILIER, BRUSHED NICKEL EXTERIOR LIGHT FIXTURE TO BE: MAXIM 850013, WALL MOUNTED. LIGHT FIXTURE WITH CEILING FAN TO BE SELECTED BY BUILDING MANAGER. SCALE: 1/4" = 1'-0" 1 REFLECTED CEILING/ ELECTRICAL PLAN A102 0 2'4'8' BANK SET 03.08.13 STATE RELEASE 04.16.13 CDB, LGADJS 03.08.13 DJS,RJP