HomeMy WebLinkAbout10-22-13 Drawing Set.pdfUPDN UPDNUPDN UPDN UPDN 1'-5" MIN. 1'-7" TO SEAT HDCP. MAX. 1'-5" MIN. SPACE MUST REMAIN FREE AND CLEAR OF OBSTRUCTION 2'-10" HDCP MAX. 2'-3" HDCP MIN. 8" 6" 9"2'-5" MIN. WALL MOUNT WATER CLOSET 17" - 19" MIN. CLEAR 2'-3" HDCP MIN. 9" MIN. 8" MAX 6" MAX 3' - 0" HDCP DRINKING FOUNTAIN 59" MIN. (AT FLOOR-MOUNTED TOILET) 4' - 10" 1' - 0" 56" MIN. (AT WALL-HUNG TOILET) TOILET PARTITION (WHERE OCCURS) 6" 12" MIN. 24" MIN. 16" - 18"33" - 36" 17" - 19" 17" MAX. ACCESSIBLE HEIGHT 24" STD. 3' - 6" 1' - 0" 2' - 0" 15" MIN. WATER CLOSET SIDE WALL 1 1/2" DIA. GRAB BAR WITH 1 1/2" GAP FROM WALL WATER CLOSET BACK WALL URINAL ACCESSIBLE SEAT HT.TOILET PAPER MOUNTING AREA URINAL SCREEN (WHERE OCCURS) LAVATORY OR VANITY SINK 60" MIN. MIN. 9" 6" TOE SPACE 6" TOE SPACE SEE PLANS FOR PROJECT-SPECIFIC DIMENSIONS SEE PLAN NOTES: 1.REFERENCE THE CURRENT APPLICABLE STATE AND FEDERAL ACCESSIBILITY STANDARDS FOR ACCESSIBLE DESIGN. 2.SEE FLOOR PLANS AND OTHER DETAILS FOR APPLICABLE PROJECT SPECIFIC REQUIREMENTS AND DIMENSIONS. 3.AMBULATORY ACCESSIBLE COMPARTMENTS AND FIXTURES, WATER CLOSETS, AND TOILET COMPARTMENTS FOR CHILDREN'S USE ARE NOT SHOWN. SEE APPLICABLE CODES FOR REQUIREMENTS. 39" - 41" 54" MIN. 42" MIN. 12" MAX. MIN. 1 1/2" 15" MIN. 7" - 9"MIN. 9" TOILET PARTITION (WHERE OCCURS) VERTICAL GRAB BAR 36" MIN. STANDARD ROLL-IN-TYPE SHOWER WITH SEAT 60" MIN. WIDTH 30" MIN. DEPTH STANDARD ROLL-IN-TYPE SHOWER WITH SEAT MAX. 6" MAX. 6" 33" - 36"MIN. 1 1/2" 38" MIN. 48" MAX. 27" MAX. 17" - 19" SEAT HEIGHT CONTROL LOCATION FOLDING-TYPE ACCESSIBLE SHOWER SEAT 33" - 36" BACK WALL 48" MAX. 2' - 10" HDCP. 15" MIN. SANITARY NAPKIN DISPOSAL TO OPERABLE MECHANISM 4' - 0" MAX. SOAP DISPENSER 48" MAX HDCP. 54" MAX. TOILET SEAT COVER DISPENSER SANITARY NAPKIN / TAMPON DISPENSER TO OPERABLE MECHANISM 48" HDCP. FORWARD REACH TO OPERABLE MECHANISM 54" MAX. SIDE REACH ROBE HOOK SHOWER CURTAIN ROD HAND DRYER 48" MAX. HDCP. 6' - 0" 6' - 8" MAX. HDCP. 4' - 0" CENTERLINE OF UPPER MOST CONTROL CL 6" MIN. STAINLESS STEEL HINGED ACCESS PANEL 1'-4" X1'-4" STAINLESS STEEL HINGED ACCESS PANEL 1'-4" X1'-4" 3' - 6" MAX. ACCESS PANEL BELOW LAVATORY ACCESS PANEL ABOVE TOILET 48" MAX. TO OPERABLE MECHANISM 48" MAX. MIRROR PAPER TOWEL DISPENSER ABOVE LAVATORIES, SINKS, OR COUNTERS 40" MAX.* SEE PLAN ROOM SIGNAGE 5' - 0" 4" SURFACE MOUNTED FULL-LENGTH MIRROR SEE PLAN SEE PLAN 1' - 4"OTHER CONDITIONS ROBE HOOK 48" MAX. SHELVES 40" MIN. - 48" MAX. *DIMENSION IS TO BOTTOM OF REFLECTIVE SURFACE TOILET PAPER DISPENSER 15" MIN. 7" - 9" 1.CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE SITE TO BECOME FAMILIAR WITH AND VERIFY THE EXISTING CONDITIONS. THESE DEMOLITION DRAWINGS SHALL SERVE TO AID THE CONTRACTOR IN HIS EVALUATION OF THE EXTENT OF DEMOLITION; BUT SHALL NOT BE HELD TO BE ALL INCLUSIVE. 2.CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED FOR THE INSTALLATION OF NEW CONSTRUCTION AND AS NECESSARY TO FULFILL THE PURPOSE AND INTENT OF THE FINISHED WORK, WHETHER OR NOT IT IS SPECIFICALLY SHOWN OR NOTED IN THESE DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ITEMS CALLED TO BE REMOVED THROUGH OUT THE ENTIRE SET OF DOCUMENTS. 3.CONTRACTORS SHALL FIELD INSPECT ALL DEMOLITION WORK PRIOR TO REMOVAL, TO INSURE SUCH REMOVAL DOES NOT IMPAIR STRUCTURAL INTEGRITY OF THE EXISTING BUILDING. IF THE INSPECTION INDICATES THAT THE STRUCTURAL INTEGRITY MAY BE IMPAIRED, NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY. 4.REMOVE ALL DAMAGED OR EXISTING FINISH MATERIALS FROM REMAINING WALLS, PARTITIONS AND COLUMNS (GYPSUM BOARD,WALL FABRIC, PANELING, TILE, MASONRY, CONCRETE, ETC...). PATCH WALLS AND COLUMNS AS REQUIRED TO RECEIVE NEW FINISH MATERIALS. 5.CONTRACTORS SHALL BE RESPONSIBLE FOR PROVIDING, INSTALLING AND MAINTAINING DUST TIGHT TEMPORARY CONSTRUCTION BARRIERS TO ALL AREAS WITHIN THE CONSTRUCTION LIMIT LINES, DURING THE CONSTRUCTION PROCESS. LOCATIONS SHALL BE COORDINATED WITH THE OWNER AND ARCHITECT. 6.ALL CONSTRUCTION AREAS, REMOVAL TRAFFIC PATTERN AREAS AND ASSOCIATED WORK AREAS SHALL BE KEPT CLEAN OF DEBRIS BY THE CONTRACTORS DAILY. 7.PROTECT FROM DEMOLITION AND RECONSTRUCTION DEBRIS, ALL "EXISTING TO REMAIN" FIXTURES AND EQUIPMENT REQUIRED TO REMAIN IN PLACE DURING CONSTRUCTION. 8.REFER TO REMAINING DRAWINGS FOR RECONSTRUCTION. ALL CONTRACTORS SHALL COORDINATE THE DEMOLITION AND RECONSTRUCTION WORK, TO BE ASSURED THAT THEIR WORK IS COMPLIMENTARY TO THE WORK OF ALL OTHER CONTRACTORS AND COMPLETE IN ALL RESPECTS. 9.UNLESS NOTED OTHERWISE ALL DEMOLITION MATERIAL BECOMES THE PROPERTY OF THE CONTRACTORS AND IS TO BE REMOVED FROM THE PROPERTY, IN A LEGAL MANNER. THE OWNER RESERVES THE RIGHT AND SHALL BE GIVEN THE OPPORTUNITY TO CLAIM ITEMS WHETHER OR NOT THOSE ITEMS WERE SPECIFICALLY NOTED FOR REMOVAL, RELOCATION, OR AS RETURNED TO OWNER AND SAME SHALL BE RETURNED TO OWNER. 10.THE CONTRACTOR RESPONSIBLE FOR GENERAL DEMOLITION WORK SHALL COORDINATE ANY AND ALL ASBESTOS REMOVAL WITH THE OWNER. ALL ASBESTOS REMOVAL WILL BE PREFORMED BY A LICENSED ASBESTOS REMOVAL CONTRACTOR. THIS TYPICALLY INCLUDES FLOOR TILE, TILE MASTIC AND PIPE INSULATION. 11.ITEMS SHOWN IN LIGHTER PEN WEIGHTS ARE EXISTING TO REMAIN. 12.GENERAL CONTRACTOR RESPONSIBLE FOR PATCHING ALL REMOVED ELECTRICAL OUTLETS. ELECTRICAL CONTRACTOR TO PROVIDE GENERAL CONTRACTOR WITH QUANTITIES. 13.REMOVE EXISTING FINISHES AS REQUIRED TO INSTALL NEW FINISHES. PREPARE SURFACES TO RECEIVE NEW FINISH AS PER FINISH MANUFACTURER'S PRINTED INSTRUCTIONS, SEE FINISH SCHEDULE FOR NEW FINISHES. 14.REMOVE EXISTING CEILINGS AND CEILING SUPPORT SYSTEM WHERE NEW CEILINGS ARE INDICATED, UNLESS OTHERWISE NOTED. THESE NOTES SHALL APPLY TO ALL DEMOLITION DRAWINGS AND TO ALL CONTRACTORS AND/OR SUBCONTRACTORS THAT WORK ON THIS PROJECT. INDICATES EXISTING WALL TO BE REMOVED IN ITS ENTIRETY. INDICATES EXISTING DOOR, FRAME AND ASSOCIATED HARDWARE TO BE REMOVED IN ITS ENTIRETY. SEE DOOR SCHEDULE FOR ITEMS TO BE SALVAGED AND REUSED IN OTHER AREAS. THESE NOTES APPLY TO ALL FLOOR PLANS, AND TO ALL CONTRACTORS AND/OR SUBCONTRACTORS THAT WORK ON THIS PROJECT. 1.OWNER WILL REMOVE ALL FURNISHINGS, LOOSE EQUIPMENT, SUPPLIES, ETC.... PRIOR TO CONSTRUCTION COMMENCING. 2.ALL EQUIPMENT AND MATERIALS LABELED AS "SALVAGE" OR "RELOCATE AS DIRECTED BY OWNER" SHALL BE REMOVED, PROPERLY PROTECTED AND TRANSPORTED TO A LOCATION ON THE PREMISES AS DIRECTED BY THE OWNER. 3.ALL GENERAL CONTRACTORS AND THEIR SUBCONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE CONSTRUCTION SITE TO BECOME FAMILIAR WITH ALL EXISTING CONDITIONS WHICH AFFECT THAT SPECIFIC PORTION OF THEIR WORK. ANY CONFLICTS OR APPARENT DEFICIENCIES MUST BE SUBMITTED TO THE ARCHITECT IN WRITING PRIOR TO BIDDING. 4.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR INFORMING IN WRITING THE OWNER ON A WEEKLY BASIS OF THE CONSTRUCTION SCHEDULE FOR THE APPROACHING TWO WEEKS CONSTRUCTION ACTIVITY. ANY STORAGE OF MATERIALS, ACCESS OR EGRESS PROBLEMS, TRAFFIC FLOW OR NORMAL OWNER OPERATIONS WHICH ARE TO BE AFFECTED MUST BE PROTECTED AND/OR AGREED UPON BY THE OWNER. ALL COSTS SHALL BE INCURRED BY THE GENERAL CONTRACTOR. 5.THE GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY WOOD BLOCKING FOR ALL TRADES. THIS BLOCKING SHALL BE FIRE RETARDANT. 6.ANY PLASTER WORK REQUIRING NEW FINISH SHALL BE SMOOTH, SOUND AND IN A FLUSH PLANE BEFORE FINISH APPLICATION. CONTRACTOR SHALL REPAIR THE SURFACE FOR THE NEW FINISH AS SCHEDULED. 7.ALL FIRE RATED WALLS AND FLOOR PENETRATIONS MUST COMPLY WITH ASTME-814. 8.ITEMS SHOWN IN LIGHTER PEN WEIGHT ARE EXISTING TO REMAIN. 9.REMOVE ALL DAMAGED GYPSUM BOARD, MASONRY, CONCRETE, PLASTER, ETC... FROM EXISTING SURFACES AND REPAIR TO MATCH ADJACENT CONSTRUCTION PRIOR TO REFINISHING. ALL SURFACES SHALL BE SMOOTH AND IN A FLUSH PLANE. 10.ALL CONSTRUCTION AREAS, REMOVAL TRAFFIC PATTERN AREAS AND ASSOCIATED WORK AREAS SHALL BE KEPT CLEAN OF DEBRIS BY THE CONTRACTORS DAILY. 11.PROTECT FROM DEMOLITION AND RECONSTRUCTION DEBRIS, ALL "EXISTING TO REMAIN" FIXTURES AND EQUIPMENT REQUIRED TO REMAIN IN PLACE DURING CONSTRUCTION. 12.REFER TO REMAINING DRAWINGS FOR RECONSTRUCTION. ALL CONTRACTORS SHALL COORDINATE THE DEMOLITION AND RECONSTRUCTION WORK, TO BE ASSURED THAT WORK IN EITHER OF THESE AREAS IS COMPLEMENTARY TO THE OTHER AND COMPLETE IN ALL RESPECTS. ANY CONFLICTS OR APPARENT DEFICIENCIES MUST BE SUBMITTED TO THE ARCHITECT IN WRITING PRIOR TO BIDDING. 13.ALL WALL HUNG CASEWORK REQUIRES CONTINUOUS HORIZONTAL WOOD BLOCKING BETWEEN STUDS AT TOP AND BOTTOM OF CASEWORK. BRACE WALL TO DECK AS REQUIRED. 14.ALL DIMENSIONS ARE FROM FACE OF BASE MATERIAL (STUD/CMU) TO FACE OF BASE MATERIAL (STUD/CMU) UNLESS NOTED OTHERWISE. 15.PORTIONS OF THE BUILDING SHALL BE OCCUPIED DURING CONSTRUCTION. THE GENERAL CONTRACTOR SHALL FOLLOW THE FOLLOWING LIFE SAFETY ISSUES. FAILURE TO LIST ALL LIFE SAFETY ISSUES DOES NOT RELIEVE THE CONTRACTORS FROM COMPLYING WITH FEDERAL, STATE AND LOCAL CODES, THE CONTRACTUAL AGREEMENT BETWEEN THE CONTRACTOR AND OWNER, AND OTHER GOVERNING BODIES WHICH HAVE JURISDICTION ON THIS PROJECT. THE FOLLOWING ARE INTERIM LIFE SAFETY CODE ISSUES WHICH ARE SPECIFIC TO THIS PROJECT AND MUST BE ADDRESSED: a.INSURE ALL EXITS PROVIDE FREE AND UNOBSTRUCTED EGRESS. STAFF AND PERSONNEL SHALL RECEIVE TRAINING AND WRITTEN NOTIFICATION IF ALTERNATIVE EXITS MUST BE DESIGNATED. b.INSURE FREE AND UNOBSTRUCTED ACCESS TO EMERGENCY DEPARTMENTS OR SERVICES FOR EMERGENCY FORCES. COORDINATE WITH OWNER AND ARCHITECT. c.INSURE FIRE ALARM, DETECTION AND SUPPRESSION SYSTEMS ARE NOT IMPAIRED. A TEMPORARY, BUT EQUIVALENT, SYSTEM SHALL BE PROVIDED, INSTALLED AND TESTED PRIOR TO ANY EXISTING FIRE SYSTEM BEING IMPAIRED. d.INSURE TEMPORARY CONSTRUCTION PARTITIONS ARE SMOKE TIGHT AND BUILT OF NON COMBUSTIBLE MATERIALS. THESE PARTITIONS SHALL BE COORDINATED WITH THE OWNER AND ARCHITECT. e.SMOKING SHALL BE PROHIBITED EXCEPT IN DESIGNATED AREAS OF THE BUILDING. f.DEVELOP AND ENFORCE STORAGE, HOUSEKEEPING AND DEBRIS REMOVAL PROCEDURES THAT REDUCE THE FLAMMABLE AND COMBUSTIBLE FIRE LOAD TO THE LOWEST LEVEL NECESSARY FOR DAILY OPERATIONS. g.IOSHA REQUIRES MATERIAL SAFETY DATA SHEETS (MSDS) FOR ALL MATERIALS BEING USED OR STORED ON THIS PROJECT BE MADE AVAILABLE TO ALL WORKERS ON THIS JOBSITE. COPIES MUST BE PROVIDED TO THE OWNER'S DIRECTOR OF SECURITY, IMMEDIATELY, AS WORK BEGINS. h.SECURE ALL TOOLS AND CONSTRUCTION MATERIALS DURING BREAKS AND NON-CONSTRUCTION HOURS. ROOM NAME 101 1 A101 SIM 1t 1 A 101A A101 1 SIM DETAIL NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER X X SHEET NUMBER DETAIL NUMBER NEW DOOR AND FRAME SPECIFIC CONSTRUCTION NOTES ROOM NAME AND NUMBER ELEVATION SYMBOL PLAN DETAIL NEW COLUMN LINE EXISTING COLUMN LINE SECTION PARTITION TYPE WINDOW ELEVATION SYMBOL TOILET ACCESSORY 1 SPECIFIC DEMOLITION NOTES 1i3.5Ax / Xx.x Architectural: Nick Slater Kyle Hardie MSKTD & Associates 317.917.1190 Interiors: Sarah Savage MSKTD & Associates 317.917.1190 ALL METAL STUD WALLS OVER 10'-0" TALL SHALL BE LATERALLY BRACED ABOVE 10'-0" WITH 1 1/2" COLD ROLLED CHANNELS AT 48" O.C. VERTICALLY. ATTACHMENT SHALL BE AS DESCRIBED AND ILLUSTRATED IN THE "UNIMAST INCORPORATED", STEEL FRAMING SYSTEMS, TECHNICAL INFORMATION MANUAL. 0=EXISTING 1=METAL STUDS 2=MASONRY 3=WOOD 4=CONCRETE 5=MISC 0=EXISTING O= EXISTING CONSTRUCTION MATERIALS AND SIZE OF WALL ARE TO BE VERIFIED BY THE GENERAL CONTRACTOR 1=METAL STUDS 1=7/8" 2=1 5/8" 3=2" 4=2 1/2" 5=3 5/8" 6=4" 7=6" 8=EXTERIOR COMPOSITE WALLS 9= INTERIOR COMPOSITE WALLS DESCRIBES THE BASE WALL MATERIAL INDICATES THE DEPTH OF THE BASE WALL MATERIAL 1 . 5 A DESCRIBES THE MATERIALS BEING USED TO COVER THE BASE WALL MATERIALS. SEE SHEET A0.1 IUHP Women's Health (Renovation Area approx. 2,610 Sq. Ft.) EXTEND TO 6" A.F.C. 1.5A 1.5B 3 5/8" METAL STUD @ 16" O.C. 5/8" GYPSUM BOARD EACH SIDE SOUND ATTENUATION BLANKET INSULATION 3 5/8" METAL STUD @ 16" O.C. 5/8" GYPSUM BOARD 1.7A 6" METAL STUD @ 16" O.C. 5/8" GYPSUM BOARD EACH SIDE SOUND ATTENUATION BLANKET INSULATION EXTEND TO 6" A.F.C.EXTEND TO 6" A.F.C. PROPOSED USE Healthcare Clinic CLASSIFICATION B-Business IBC sec. 308.3 CONSTRUCTION TYPE Type I-A IBC Table 601 AUTOMATIC SPRINKLERS Fully Sprinkled, Class I FLOOR AREA Medical Office Suite 16,580 sq. ft. HEIGHT (7) Seven Stories 106' - 8" FIRE RESISTANT REQUIREMENTS Structural Frame 3-Hours IBC Table 601 Exterior Bearing Walls 3-Hours Floor 2-Hour Roof 1-1/2 Hour Shafts 1-Hour (Less than 3-Stories)IBC 707.4 2-Hours (4 Story) Stairs 1-Hour (Less than 3-Stories)IBC 1005.3.2 2-Hours (4 Story) APPLICABLE CODES NFPA 101 Life Safety Code: 2000 Edition. Indiana Fire Prevention and Building Safety Code IAC 675 12 Administrative Rules 3 Building Code: 2006 International Building Code with Indiana Amendments 16 Plumbing Code: 1997 Uniform Plumbing Code with Indiana Amendments 17 Electrical Code: 2008 Electrical Code with Indiana Amendments 18 Mechanical Code: 2006 International Mechanical Code with Indiana Amendments 19 The Indiana Energy Conservation Code, 2010 Edition (consisting of ASHRAE 90.1, 2007 Edition with Indiana Amendments) 22 Fire Prevention Code: 2006 International Fire Code with Indiana Amendments 1.General Contractor is responsible to provide all Mechanical, Electrical, and Plumbing design, material, and labor under separate vendor contract as required for a complete installation in compliance with all State, Local, and Health Department Building Codes. 2.Architectural Documents indicating Mechanical, Electrical, and Plumbing work are schematic concepts. Documents are for reference only. 3.Architectural Documents provide suggested fixture locations and fixture types. All sizing, circuiting, and switching to be vendor engineered by contractor. 4. HVAC Systems to be vendor engineered under separate contract. 5.Plumbing Piping Systems to be vendor engineered under separate contract with isometrics. 6.Fire Protection System to be vendor engineered under separate contract. 7.Electrical Power and Data Systems to be vendor engineered under separate contract. 8.Lighting Systems to be vendor engineered under separate contract. Contractor shall provide individual lump sum breakouts for the following scope of work: 1.Conversion of existing Soiled Closet to Staff Toilet #3003 and all associated items. 2.Conversion of existing Storage Room to Nurse Station #3047 and all associated items. 3.Conversion of existing Work Area to MD Lounge #3014 and existing Triage Alcoves to NST(s) #3056A /B and Office #3056C and all associated items. 4.Addition of sliding glass reception windows and wall modifications near existing Check-in/Check-out #3041 and all associated items. 5.Removal of reception desk and flooring within existing Waiting #3043 and all associated items. 6.Replacement of carpet and resilient base through out all passages. Refer to finish plan. DAVID ARCHI T E C T R E G I S TERE D AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 6278 10-22-13 North Hospital IUHP Women's Health 10/22/2013 10:14:19 AM Sheet Index T1.1 11725 Illinois Street, MOB Suite 350 I Carmel, Indiana 46032 North Hospital IUHP Women's Health Partial Suite Renovation Architectural T1.1 Sheet Index A2.1 Third Floor Plans A3.1 Enlarged Plans, Door Sched, Details & Ref. Ceiling Plan A10.1Casework Elevations A11.1Finish Plan and Schedule Plumbing Fixture Mounting Heights Toilet Accessory Mounting Heights General Demolition Notes General Reconstruction Notes Graphic Symbols Contacts Partition Standards Not to Scale Key Plan Partition Types Code SummaryMEP Design Build Notes Lump Sum Bid Breakouts Revisions:Date:By: UP DN UP DN UP DN UP DN REF. REF. 6 9'-0" 7 7 7 1 1 1 14 14 2 3 2 2 2 2 4 5 5 5 8 9 10 10 10 11 11 12 13 3 2 1 4 5 6 6 6 6 767 2 1 2 9 1 1 1 Ultrasound 1 3011 Exam 15 3007 Exam 10 3012 Exam 7 3023 Exam 8 3024 Exam 3 3032 Exam 23031 Passage 3013 Passage 3033 Meds 3028 Staff Toilet 3003 Bio 3002 Exam 6 3035 Jan. 3050 Lab 3051 Clean 3052 Passage 3049 Passage 3054 Restroom 3053 Passage 3040 Files3021 Exam 11 3034 MD Work 3018 Exam 4 3037 Passage 3039 Passage 3020Exam 13 3016 Exam 16 3008 Patient Toilet3010 Exam 9 3025 Exam 1 3027 Passage 3006 Procedure 1 3004 Procedure 2 3005 Check-in (2) & Check-out (2) 3041 Waiting 3043 Storage 3030 Exam 12 3017 Dict 3009 MD Dict3026 Meds 3029 Stair 9 Elev 2 Elev 3 Elev 1 Passage 3001 3 Exam 14 3072 Work Room3073 Billing Office3074 Scales 3022 MICRO COFFEE 1/ 6278 -A10.1 NST #2 3056B NST #13056A OFFICE 3056C MD Lounge 3014 2/ 6278 - A10.1 6278 - A3.1 1 3056C 3056B 3056A 6/ 6278 - A10.1 6278 - A10.1 7 CPT-1 EXT CPT CPT-1EXT CPT Check-in & Check-out 3044 Patient Toilet 3045 1 1 9'-55/8" 9'-03/4" 6' - 8 3/4" 2 5' - 4 1/4" 3 1 4 5 3 3 4 4 Passage 3062 Passage 3070 MD Dict. 3066 Passage 3077 Passage 3083 NURSE STATION BREAK ROOM MD OFFICE PHONE TRIAGE 1.ALL FURNITURE PROVIDED BY OWNER. 2.SEE SHEET A10.1 FOR CASEWORK ELEVATIONS. 3.SEE SHEET A3.1 FOR ENLARGED PLANS. 4.DIMENSIONS ARE TO FACE OF STUDS UNLESS OTHERWISE NOTED. 5.ALL HINGED SIDE DOOR JAMBS AT STUD WALLS ARE 4" FROM FACE OF STUD UNLESS OTHERWISE NOTED. 6.ALL PARTITION TYPES ARE TO BE 1.5A UNLESS OTHERWISE NOTED. 7.PATCH AND REPAIR ALL EXISTING WALLS WITHIN AREA OF WORK PRIOR TO RECEIVING NEW FINISHES. 1.REMOVE EXISTING ACCESSORIES, i.e. TACKBOARDS, TOILET ACCESSORIES, ETC. WITHIN AREA OF WORK. Contractor shall provide individual lump sum breakouts for the following scope of work: 1.Conversion of existing Soiled Closet to Staff Toilet #3003 and all associated items. 2.Conversion of existing Storage Room to Nurse Station #3047 and all associated items. 3.Conversion of existing Work Area to MD Lounge #3014 and existing Triage Alcoves to NST(s) #3056A /B and Office #3056C and all associated items. 4.Addition of sliding glass reception windows and wall modifications near existing Check-in/Check-out #3041 and all associated items. 5.Removal of reception desk and flooring within existing Waiting #3043 and all associated items. 6.Replacement of carpet and resilient base through out all passages. Refer to finish plan. DAVID ARCHI T E C T R E G I S TERE D AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 6278 10-22-13 North Hospital IUHP Women's Health 10/22/2013 10:14:08 AM Third Floor Plans A2.1 11725 Illinois Street, MOB Suite 350 I Carmel, Indiana 46032 1/8" = 1'-0" Third Floor Demolition Plan 1/8" = 1'-0" Third Floor Plan IUHP Women's Health Plan Notes 1 ALIGN NEW WALL FINISH WITH ADJACENT CONSTRUCTION. 2 INFILL WALL OPENING WITH SIMILAR CONSTRUCTION. ENSURE THAT NEW SURFACES ARE FLUSH WITH ADJACENT WALLS. 3 PATCH AND REPAIR EXISTING VINYL WALL COVERIING AT NEW DOOR LOCATIONS AND INSTALL NEW/SALVAGED AT NEW WALL INFILL LOCATIONS. 4 AT COLUMN ENCLOSURE, PATCH AS REQUIRED FOR NEW VINYL WALL COVERING, CHAIRRAIL AND BASE. REFER TO ELEVATION 9/A10.1 FOR ALL 4 SIDES. IUHP Women's Heath Demo Notes 1 REMOVE EXISTING WALL IN ITS ENTIRETY. 2 REMOVE EXISTING CASEWORK IN ITS ENTIRETY. 3 REMOVE EXISTING SHELVING IN ITS ENTIRETY. 4 REMOVE EXISTING DOOR AND FRAME IN ITS ENTIRETY. 5 REMOVE PORTION OF EXISTING WALL AS REQUIRED FOR NEW OPENING. 6 REMOVE EXISTING FLOOR FINISH. PATCH AND REPAIR AS REQUIRED FOR NEW FINISHES. 7 REMOVE EXISTING CEILING IN ITS ENTIRETY. 8 REMOVE EXISTING CERAMIC TILE FLOOR. GRIND FLOOR AND PATCH AS REQUIRED FOR NEW FLOOR FINISH. 9 REMOVE EXISTING COUNTER AND VINYL WALL COVERING. PREP WALL TO RECEIVE NEW WALL ASSEMBLY COUNTERTOP, TRANSITION TOP AND SLIDING GLASS WINDOW. REFER TO 8 & 11/A10.1. 10 REMOVE PORTION OF EXISTING CARPET. PREP FOR NEW FINISHES. 11 REMOVE EXISTING INTERIOR WINDOWS. 12 REMOVE PORTION OF EXISTING WALL FROM APPROXIMATELY 4'-2" TO EXISTING BULKHEAD. PREP WALL TO RECEIVE NEW FINISHES AND WINDOWS. SALVAGE EXISTING VINYL WALL COVERING BELOW. REFER TO 12/A10.1. 13 REMOVE EXISTING TRANSACTION COUNTER. PREP FOR NEW COUNTER AND SLIDING GLASS WINDOW. REFER TO 8 & 11/A10.1 SIM. 14 REMOVE EXISTING LOW WALL, TRIM AND CENTER WATER FEATURE IN ITS ENTIRETY. PREP COLUMN ENCLOSURE FOR NEW FINISHES. General Plan Notes General Demolition Notes AREA OF WORK AREA OF WORK Lump Sum Bid Breakouts Revisions:Date:By: 1.ACCESSORY PROVIDED AND INSTALLED BY CONTRACTOR. 2.ACCESSORY PROVIDED AND INSTALLED BY OWNER. BLOCKING PROVIDED BY CONTRACTOR. VERIFY LOCATION. 3.ACCESSORY PROVIDED BY OWNER AND INSTALLED BY CONTRACTOR. 4.AT EACH SINK LOCATION WITHIN AREA OF WORK (APPROXIMATELY 4 TOTAL) F SEE SCHED. SEE SCHED. 1 2" SEE SCHED. 2"SEE SCHED.2" Staff Toilet 3003 2/ 6278 - A3.1 3/ 6278 - A3.1 B C A F H D G E J 1' - 6" 3' - 0" 3' - 0" 1' - 6" FLOOR MOUNTED PL-1 3' - 0"3' - 0" 2' - 10" SOLID SURFACE COUNTER AND BACKSPLASH - SS-1 24"w x 36"h MIRROR RESILIENT BASE - RB-1 2' - 6" 4' - 6" 1" FILLER 3' - 0" SLOPE TOP - PL-1 PL-1 REFER TO PARTITION TYPE FOR WALL CONSTRUCTION DOUBLE METAL STUD FRAMING CONTINUOUS SEALANT (BOTH SIDES) HOLLOW METAL DOOR FRAME 2" SEE SCHEDULE REFER TO PARTITION TYPE FOR WALL CONSTRUCTION DOUBLE METAL STUD FRAMING CONTINUOUS SEALANT (BOTH SIDES) HOLLOW METAL DOOR FRAME 2"SEE SCHEDULE 1 MD Work / Lounge 3058MD Lounge 3014 NST #2 3056B Passage 3040 Restroom3053 Passage 3054 Clean 3052 Lab 3051 Passage 3049 Waiting3043 Check-in & Check-out 3044 Exam 15 3064 Passage 3062 Passage 3070 Exam 17 3069 Exam 16 3065 NST 3080Consult 3067MD Dict. 3066 Patient Toilet 3045 Closet 3068 Closet 3081 Storage 3030 Exam 1 3027 Exam 2 3031 MD Dict 3026 Passage 3033 Exam 33032 Check-in (2) & Check-out (2) 3041Exam 7 3023 Exam 83024 Exam 9 3025 Patient Toilet 3010 Ultrasound 1 3011 Exam 10 3012 Exam 113034 Files3021 Passage 3013 Dict 3009 Exam 16 3008 Passage3006 Procedure 1 3004 Procedure 2 3005 Exam 153007 Passage3001 Bio3002 Staff Toilet 3003 Passage3020 Exam 123017 MD Work3018 MD Office 3038 Exam 6 3035 Exam 4 3037 Passage 3039 Office3036 Phone Booth 3048 Staff Break 3047 NST #1 3056A OFFICE 3056C Work Room 3073 Exam 14 3072 Exam 13 3016 A.F.F. 9' - 0" A.F.F. 9' - 0" A.F.F. 9' - 0" A.F.F. 9' - 0" A.F.F. 9' - 0" 1 1 1 2 2 3 3 3 3 3 3 2 1 4 5 4 5 5 6 GYPSUM BOARD CEILING/BULKHEAD 1.REFER TO MEP FOR FIXTURE TYPES AND LOCATIONS. 2' x 2' LAY-IN CEILING 1.ALIGN ALL CEILING AND BULKHEAD REVEALS, CONTROL OR SEISMIC JOINTS WITH THE ADJACENT REVEAL, CONTROL OR SEISMIC JOINTS IN WALLS INDICATED ON ELEVATIONS. 2.ALL CEILING AND BULKHEAD HEIGHTS INDICATED ARE TO FINISHED FACE OF GYPSUM BOARD OR TO THE BOTTOM FACE OF ACOUSTICAL CEILING TILE PAD, UNLESS NOTED OTHERWISE. 3.CEILING CONTRACTOR TO PROVIDE ALL CEILING GRID TO SUPPORT HVAC SUPPLY DIFFUSERS AND RETURN GRILLS. 4.DEVICES OTHER THAN LIGHTING AND DIFFUSERS ARE SHOW IN APPROXIMATE LOCATIONS, FINAL LOCATION TO BE COORDINATED WITH ALL TRADES AND ARCHITECT. 5.AT LOCATIONS WHERE GYPSUM BOARD CEILINGS ARE INDICATED, THE CONTRACTOR HAS THE OPTION TO USE LIGHT GAGE METAL FRAMING OR SUSPENDED GYPSUM BOARD GRID UNLESS OTHERWISE DETAILED. THE CONTRACTOR WILL COORDINATE ANY MODIFICATIONS WITH THE OTHER TRADES ON THE PROJECT. THE CEILING CONTRACTOR'S FINAL MEANS AND METHODS WILL NOT CONFLICT WITH THE WORK OF OTHERS OR THE INTENT OF THESE DOCUMENTS. 6.WHERE EXISTING SUSPENDED ACOUSTICAL CEILINGS ARE SCHEDULED TO REMAIN, CUT AND PREP THE CEILING GRID IN PREPARATION FOR REPAIRING. SALVAGE ENOUGH CEILING PADS FOR RECONSTRUCTION. STORE AND PROTECT ALL MATERIALS. USE NEW MATCHING MATERIALS FOR RECONSTRUCTION AS REQUIRED. 7.SEE THE ROOM FINISH SCHEDULE FOR ADDITIONAL COMMENTS REGARDING MATERIALS AND FINISHES. 8.THE DESIGNATION 'CJ' INDICATES GYPSUM BOARD CONTROL JOINTS. WHERE INDICATED PROVIDE USG #093 ZINC CONTROL TYPICAL. INSTALL JOINT THROUGH THE FULL EXTENTS OF ANY GYPSUM CEILING OR BULKHEAD. WHERE THE GYPSUM CEILING COMPONENT MEETS A GYPSUM WALL, EXTEND THE CONTROL JOINT DOWN TO THE FLOOR TYPICAL. 9.THE GENERAL CONTRACTOR WILL PROVIDE AND INSTALL ALL SUPPLEMENTAL AND/ OR MISCELLANEOUS STEEL FRAMING AS REQUIRED BY THEMSELVES OR BY THEIR SUBCONTRACTORS FOR THE INSTALLATION OF THE EQUIPMENT SCHEDULED AND SPECIFIED. NOT ALL OF THE REQUIRED SUPPORT STEEL MAY BE DETAILED OR CALLED OUT FOR IN THESE DOCUMENTS. COORDINATE ALL REQUIREMENTS WITH THE SPECIFICATIONS, EQUIPMENT SUPPLIERS AND SUBCONTRACTORS. THERE WILL BE NO CHANGE ORDERS TO THE PROJECT FOR SUPPLEMENTAL STEEL WHERE OMISSIONS MAY OCCUR IN THE BIDDING DOCUMENTS. THESE NOTES APPLY TO ALL CONSTRUCTION DRAWINGS AND TO ALL CONTRACTORS AND/OR SUBCONTRACTORS THAT WORK WITHIN THIS BUILDING. HARDWARE SET No. 2 (3) HINGES (1) PRIVACY LOCKSET (1) WALL BUMPER (4) DOOR SILENCER HARDWARE SET No. 1 (3) HINGES (1) PASSAGE SET (1) WALL BUMPER (4) DOOR SILENCER 1.ALL HARDWARE SETS TO MEET ADA-AG REQUIREMENTS AND MATCH BUILDING STANDARD FINISH - SATIN CHROME, HEAVY GRADE COMMERCIAL w/ BEST CORE LOCK - SATIN CHROME FINISH - REMOVABLE. 2.DOORS SHALL BE 0F 1-3/4" FLUSH PANEL, SOLID CORE NATURAL CHERRY WOOD DOOR WITH STAINED FINISH. 3.DOOR FRAME SHALL BE KNOCK DOWN METAL FRAME w/ CAULKED MITERED CORNERS. 4.ALL GLASS SHALL BE 1/4" CLEAR, TEMPERED. Contractor shall provide individual lump sum breakouts for the following scope of work: 1.Conversion of existing Soiled Closet to Staff Toilet #3003 and all associated items. 2.Conversion of existing Storage Room to Nurse Station #3047 and all associated items. 3.Conversion of existing Work Area to MD Lounge #3014 and existing Triage Alcoves to NST(s) #3056A /B and Office #3056C and all associated items. 4.Addition of sliding glass reception windows and wall modifications near existing Check-in/Check-out #3041 and all associated items. 5.Removal of reception desk and flooring within existing Waiting #3043 and all associated items. 6.Replacement of carpet and resilient base through out all passages. Refer to finish plan. DAVID ARCHI T E C T R E G I S TERE D AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 6278 10-22-13 North Hospital IUHP Women's Health 10/22/2013 10:14:10 AM Enlarged Plans, Door Sched, Details & Ref. Ceiling Plan A3.1 11725 Illinois Street, MOB Suite 350 I Carmel, Indiana 46032 Toilet Accessory Remarks IUHP WOMEN'S HEALTH TOILET ACCESSORY SCHEDULE NOTE: MANUFACTURER'S NUMBERS REFER TO "BOBRICK CO." UNLESS NOTED OTHERWISE AND ARE USED FOR QUALITY CONTROL ONLY. THEY ARE NOT INTENDED TO LIMIT BIDDING TO ONE MANUFACTURER. ITEM ACCESSORY DESCRIPTION MANUFACTURER'S NUMBERS REMARKS A SINGLE GRAB BAR - 42"B-6806x42 1 B SINGLE GRAB BAE - 36"B-6806x36 1 C SINGLE GRAB BAR - 18" (VERTICAL)B-6806x18 1 D SURFACE MOUNTED 2 ROLL TOILET PAPER DISPENSER --2 E SURFACE MOUNTED PAPER TOWEL DISPENSER --3,4 F SURFACE MOUNTED SOAP DISPENSER --2,4 G 24"x36" MIRROR B-165-2436 1 H SANITARY NAPKIN DISPOSAL B-254 1 J ROBE HOOK B-6717 1 IUHP WOMEN'S HEALTH DOOR AND OPENING SCHEDULE Opening No. Door Frame Details Label Door Glass Hdw . Set RemarksSizeMat.Ele.Mat.Ele.HeadJambSill 3056A 3'-6" x 7'-0" x 1 3/4"WD F HM 1 4/A3.15/A3.1 ------1 3056B 3'-6" x 7'-0" x 1 3/4"WD F HM 1 4/A3.15/A3.1 ------1 3056C 3'-0" x 7'-0" x 1 3/4"WD F HM 1 4/A3.15/A3.1 ------2 Door Elevations Frame Elevations 1/4" = 1'-0" Enlarged Plan1 1/2" = 1'-0" Casework Elevation2 1/2" = 1'-0" Casework Elevation3 1 1/2" = 1'-0" Door Head Detail4 1 1/2" = 1'-0" Door Jamb Detail5 1/8" = 1'-0" Third Floor Reflected Ceiling Plan General Ceiling Notes IUHP Women's Health Reflected Ceiling Notes 1 EXISTING ACOUSTICAL LAY-IN CEILING TO REMAIN. 2 EXISTING GYPSUM BOARD BULKHEAD TO REMAIN. 3 NEW 24"x24" ACOUSTICAL LAY-IN CEILING. 4 INFILL, PATCH AND REPAIR BULKHEAD AT WALL REMOVAL AND NEW WINDOW ASSEMBLY. 5 PATCH AND REPAIR EXISTING BULKHEAD AT WALL PARTITION AND LIGHTING REMOVAL, NEW LIGHT LOCATIONS, AND BLOCKING FOR RESIN PANELS. REPAINT ENTIRE BULKHEAD. 6 NEW GYPSUM BOARD BULKHEAD. MATCH AND ALIGN WITH EXISTING HEIGHT AND CURVED FACE(S). STAFF TOILET 3003 STAFF TOILET 3003 General Ceiling Plan Notes AREA OF WORK Door Hardware Schedule General Door NotesLump Sum Bid Breakouts Revisions:Date:By: REF. 1.CONTRACTOR SHALL PROVIDE WOOD BLOCKING AS REQUIRED FOR INSTALLATION OF ALL UPPER AND LOWER UNITS 2.EDGE OF COUNTERTOP TO BE 1 1/2" THICK. 3.CABINET MFG. SHALL COORDINATE WITH OWNER ALL LOCATIONS FOR " GROMMETS" QUANTITY WILL BE IDENTIFIED PER ELEVATION. ALL GROMMETS TO BE 3 1/2" DIA.WITH BLACK PLASTIC TRIM RING - LOCATE AT REAR OF COUNTER. OR AS DIRECTED BY OWNER. 4.ALL EXPOSED ENDS AND BACKS OF CASEWORK TO BE FINISHED SAME AS BALANCE OF EXPOSED SURFACE, SEE FINISH SCHEDULE. 5.APPLY 1" RAD. ON ALL OUTER CORNERS OF COUNTER TOPS, U.N.O. 6.ALL END PANEL SUPPORT SHALL BE CONSTRUCTED W/ 1 1/2" LAMINATED PARTICLE BD. 7.ALL COUNTER TOPS SHALL EXTEND 1" BEYOND FRONT OF CABINET DRAWER FACE. 8.ALL DRAWERS AND DOOR HANDLES SHALL BE TYPE " STANLEY, MODEL No. 4484 - CHROME VS26D 9.ALL BASE CABINET DEPTH SHALL BE 24" UNLESS NOTED OTHERWISE 10.ALL UPPER CABINET DEPTH SHALL BE 14" UNLESS NOTED OTHERWISE 11.APPLY A 4" BACKSPLASH AT PERIMETER OF ALL COUNTER TOPS 12.APPLY (1) ADJUSTABLE SHELF IN ALL BASE UNITS, AND (2) ADJUSTABLE SHELVES IN ALL. UPPER UNITS W/ EXCEPTION OF SINK BASE UNITS. (UNLESS NOTED OTHERWISE). ALL SHELVES IN CASEWORK TO BE ADJUSTABLE ON 1" CENTERS VERTICALLY. 13.ALL BASE UNITS SHALL HAVE A 4" H. x 3" D. TOE SPACE WITH RUBBER BASE BY FLOORING CONTRACTOR. BASE TO EXTEND TO ALL EXPOSED SIDES OF CASEWORK. 14.REFER TO FLOOR PLAN FOR ALL WALL PARTITION TYPES 15.PAPER TOWEL DISPENSER LOCATED AT EVERY SINK. SUPPLIED BY OWNER, INSTALLED BY G.C. 16.FOR ALL FILES DESIGNATED "BY OWNER" - CONTRACTOR TO VERIFY ACTUAL HEIGHT OF FILES TO BE PURCHASED FOR COORDINATION, IF USED AS SUPPORT FOR COUNTER TOP 17.INSTALL CLEAR SEALANT CONTINUOUS BETWEEN TOP OF BACKSPLASH AND WALL. 18.ALL HARDWARE FOR ANCHORING/SUPPORTING CASEWORK SHALL BE CONCEALED. 19.PROVIDE 2X2 WOOD BLOCKING CONTINUOUS AT PERIMETER FOR COUNTERTOP/SHELF SUPPORT - PAINT TO MATCH WALL. 20.ALL COUNTERTOPS WITHOUT BACKSPLASH SHALL BE SCRIBED TO ADJACENT WALLS/CASEWORK. 21.4 DIGIT NUMBER ABOVE OR BELOW CASEWORK REFERS TO HEIGHT AND WIDTH OF UNIT. 22.FILLERS PANELS BY CABINET MANUFACTURER TO MATCH CABINETS. PROVIDE AND INSTALL. 23.ALL COUNTERTOPS SHALL BE LAMINATE EXCEPT AT TRANSACTION HEIGHT, SINK LOCATIONS OR OTHERWISE NOTED. 24.WALL PROTECTION AT RECEPTION 3098/OUT-TAKE TO RUN CONTINUOUS WITH NO VERTICAL JOINTS AND FROM FLOOR TO UNDERSIDE OF COUNTER. " L " = DOOR/DRAWER TO BE LOCKED WITH KEY CYLINDER. COORDINATE WITH OWNER ON KEYING REQUIREMENTS " F " = FILE DRAWER, INTERIOR DIMENSIONS SHALL MEET STANDARD FILE DRAWER DIMENSIONS. INSTALL HANGING FILE HARDWARE. " UL " = UNDER UPPER CABINET LIGHT, REFER TO ELECTRICAL DRAWINGS, APPLY 2" LAMINATED APRON. " S " = STRUCTURAL SUPPORT FOR COUNTER AND OR RECEPTION DESK. REFER TO " AP " = REMOVABLE ACCESS PANEL. PROVIDE COUNTERSUNK ANCHORS. " G " = GROMMETS, VERIFY LOCATION WITH OWNER " K " = KEYBOARD TRAY BY OWNER CABINET MFG. SHALL FIELD VERIFY ALL WALL DIMENSIONS PRIOR TO FABRICATION. ALL GENERAL CASEWORK NOTES APPLY TO ALL CASEWORK THROUGH OUT SET 2' - 6" 1' - 8" 2' - 10" 2' - 0" 7' - 0" 1" FILLER 1' - 6" 1" FILLER 1' - 6"2' - 6" 4' - 1" ULSOLID SURFACE COUNTER AND BACKSPLASH - SS-1 SLOPE TOP - PL-1 PL-1 PL-1 PL-1 RESILIENT BASE - RB-1 L L L MICROWAVE REFRIGERATOR SOLID SURFACE COUNTER AND BACKSPLASH - SS-1 2' - 8"2' - 6"1' - 6"2' - 6" 2' - 6" 1' - 8" 2' - 10" 2' - 0" 7' - 0" PL-1 PL-1 ADJUSTABLE SHELF RESILIENT BASE - RB-1 PL-1PL-1 2' - 8"2' - 6"1' - 6"2' - 6" 9' - 2" 1' - 0" coffee PL-1 Staff Break 3047 Exam 43037 Work Room 3073 5/ 6278 - A10.1 COPIER FABRIC WRAPPED TACKBOARD PANEL 1/2" THICK, FWC-1 2' - 6"2' - 6"2' - 6"1" 2' - 0" 2' - 2" 2' - 10" 2' - 0" 7' - 0" PL-1 PL-1 PL-1 1' - 6"3' - 0"2' - 6"2' - 6"2' - 6"1" PL-1 PL-1 PL-1PL-1PL-1 2" 2' - 8" 2" 2' - 0"8" TYPICAL DIMENSIONS AND PATTERN 4' - 3 1/4" 3/4" 4' - 2" - --- EXISTING VINYL WALL COVERING (PROTECT AND PATCH) EXISTING BASE VWC-1 VWC-1 VWC-1 VWC-1 1x3 MAPLE CHAIR RAIL (STAIN TO MATCH DOORS) WOOD BASE - WD-1 PATCH AND REPAIR WALLS AFTER DEMOLITION ELEVATION REFERS TO ALL 4 SIDES OF COLUMN ENCLOSURES COORD. w/ EXISTING CHAIRS 4 / 6 2 7 8 - A 1 0 . 1 - / - - - 8 6278 - A10.1 NEW COUNTERTOP (PL-2) - --- Check-in (2) & Check-out (2) 3041 Waiting 3043 NEW 'LOW' WALL CONSTRUCTION UNDER COUNTER SUPPORT (5 TOTAL - EQUAL SPACE) R 4 6 '-7 5 /8 " R 48'-7 5/8" R 49'-7 5/8" (CURVED FACE +/- 22'-6 1/2") 22' - 0" RESIN PANEL (2 TOTAL - EQUAL SPACE) 5' - 0" 2' - 6" (EXISTING BULKHEAD) 7' - 6" NEW COUNTERTOP (PL-2) 2' - 1"1' - 0" 1" DECORATIVE RESIN PANEL RESILIENT BASE, MATCH EXISTING 2' - 6" EURO EDGE (BOTH EDGES, BOTH SIDES) 3 5/8" METAL STUD ASSEMBLY w/ 5/8" GYPSUM BOARD (BOTH SIDES) 3"2' - 8"2" DECORATIVE ANGLE/FASTNER DECORATIVE ANGLE/FASTNER UNDERCOUNTER SUPPORT DAVID ARCHI T E C T R E G I S TERE D AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 6278 10-22-13 North Hospital IUHP Women's Health 10/22/2013 10:14:11 AM Casework Elevations A10.1 11 725 Il l in ois St r eet , M OB S ui t e 350 I Ca rm e l , I nd i an a 4 603 2 General Casework Notes 1/2" = 1'-0" Casework Elevation1NST #1 - 3056A OPPOSITE HAND: NST #2 - 3056B 1/2" = 1'-0" Casework Elevation2MD LOUNGE 3014 1/4" = 1'-0" Enlarged Plan3 1/2" = 1'-0" Casework Elevation5STAFF BREAK 3047 1/2" = 1'-0" Interior Elevation4CHECK-IN/CHECK-OUT 3041 1/2" = 1'-0" Interior Elevation6WAITING 3043 1/4" = 1'-0" Enlarged Plan7 3/4" = 1'-0" Section8 NOTE: ALL GLAZING IS 1/4" CLEAR, TEMPERED. Revisions:Date:By: UP DN UP DN REF. REF. FLOORS CARPET TILE CPT-1 - MANNINGTON; SCENA; KEY LARGO 8206; BRICK ASHLAR INSTALLATION CPT-2 - MANNINGTON; PORTELA; KEY LARGO 8206; QUARTER TURN INSTALLATION CPT-3 - MANNINGTON; CLOSE KNIT II; KEY LARGO 8206; MONOLITHIC INSTALLATION VINYL COMPOSITION TILE VCT-1 - MANNINGTON PROGRESSIONS VINYL COMPOSITION TILE; 55123 WHEAT BASE RESILIENT BASE RB-1 - NEW BASE TO MATCH EXISTING WOOD BASE WD-1 - MAPLE BASE; STAINED TO MATCH DOORS; PROFILE TO MATCH EXISTING RESILIENT BASE IN WAITING. WALLS PAINT PT - TO BE SELECTED BY OWNER - MATCH EXISTING VINYL WALL COVERING VWC-1 - MDC WALLCOVERINGS; VYCON; OASIS BASIC LINEN Y449120A FABRIC WALL COVERING FWC-1 - MDC WALLCOVERINGS; TREK SILK; PTD8013 CEILINGS ACOUSTICAL TILE CEILING ACT-1 - NEW TILE AND GRID TO MATCH EXISTING SYSTEM CASEWORK PLASTIC LAMINATE (CASEWORK, COUNTERS) PL-1 - WILSONART; AMBER CHERRY; FINE GRAIN FINISH 7919K-78 PL-2 - FORMICA; INDIGO TERRA; MATTE FINISH 7236-58 SOLID SURFACE COUNTERTOPS SS-1 - DUPONT CORIAN; FOSSIL A.FOR ALL FLOORING MATERIALS INSTALLED ON GRADE OR BELOW GRADE: THE FLOORING CONTRACTOR SHALL BE RESPONSIBLE B.TO INCLUDE IN THEIR BID PRICES ALL REQUIRED MATERIALS AND LABOR FOR A COMPLETE INSTALLATION THAT MEETS THE MANUFACTURER'S TOTAL SYSTEM PERFORMANCE. THIS INCLUDES ALL PREP MATERIALS AND LABOR REQUIRED TO MEET MANUFACTURER'S WRITTEN SPECIFICATIONS FOR MOISTURE, PH, SMOOTHNESS OR LEVELNESS OR CLEANLINESS OF NEW OR EXISTING SUBSTRATES, ETC. THIS INSTALLATION SHALL INCLUDE THE MANUFACTURER'S SPECIFIED ADHESIVES, SEALERS, ETC. C.PAINT ALL HOLLOW METAL DOORS, WINDOW FRAMES, AND DOOR FRAMES TO MATCH EXISTING, SEMI-GLOSS. D.PATCH AND MATCH ALL FINISHES DUE TO CONSTRUCTION. E.SEE REFLECTED CEILING PLAN AND DETAILS FOR LOCATION AND HEIGHT OF CEILINGS. F.EVERY TRANSITIONS BETWEEN FLOORING MATERIALS TO BE FLUSH. IT IS FLOORING CONTRACTOR'S RESPONSIBILITY TO LEVEL SUBSTRATE AS NECESSARY FOR MATERIALS TO TRANSITION AT LEVEL HEIGHT, INCLUDING GRINDING OR BUILDING UP OF CONCRETE. ALL TRANSITION STRIPS TO BE STAINLESS STEEL EQUAL TO SCHLUTER SYSTEMS AND MUST MEET ADA; ALL PROFILES TO BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. TRANSITION STRIPS ARE UNNECESSARY BETWEEN LIKE MATERIALS (CARPET TO CARPET, LINOLEUM TO VINYL, ETC). G.PAINT VENTS, DIFFUSERS, ELECTRICAL PANELS, FIRE CABINETS (UNLESS THEY ARE NATURAL ALUMINUM OR STAINLESS STEEL), ETC. TO MATCH WALL COLOR. (APPLICABLE THROUGHOUT ALL AREAS OF CONSTRUCTION)(SEE FINISH SCHEDULE FOR LOCATION) 1.REUSE EXISTING BASE. 2.SEE FINISH FLOOR PLAN FOR FLOORING TRANSITION AND LOCATION. 3.SEE ELEVATION SHEET A10.1 FOR DETAILS. Ultrasound 1 3011 Exam 15 3007 Exam 10 3012 Exam 73023 Exam 8 3024 Exam 33032 Exam 23031 Passage 3013 Passage 3033 Meds 3028 Staff Toilet 3003 Bio 3002 Exam 6 3035 Office 3036 Phone Booth3048 Staff Break 3047 Jan. 3050 Lab 3051 Clean 3052 Passage 3049 Passage 3054 Restroom 3053 Passage 3040 Meds3061Files3021 Exam 11 3034 MD Work 3018 MD Office 3038 Exam 4 3037 Passage 3039 Passage 3020Exam 13 3016 Exam 163008 Patient Toilet3010 Exam 9 3025 Exam 1 3027 Passage 3006 Procedure 1 3004 Procedure 2 3005 Check-in (2) & Check-out (2) 3041 Waiting3043 Storage3030 Exam 12 3017 Dict3009 MD Dict3026 Meds 3029 Stair 9 Elev 2 Elev 3 Elev 1 Passage 3001 Exam 14 3072 Work Room 3073 Billing Office 3074 Passage 3040 Scales 3022 NST #2 3056B NST #13056A OFFICE 3056C MD Lounge 3014 CPT-1 EXT CPT CPT-1EXT CPT Passage 3040 Passage 3070 Passage3062 MD Dict. 3066 Patient Toilet 3045 32 1 4 5 Passage 3077 Passage 3083 Check-in & Check-out 3044 5' - 0" Contractor shall provide individual lump sum breakouts for the following scope of work: 1.Conversion of existing Soiled Closet to Staff Toilet #3003 and all associated items. 2.Conversion of existing Storage Room to Nurse Station #3047 and all associated items. 3.Conversion of existing Work Area to MD Lounge #3014 and existing Triage Alcoves to NST(s) #3056A /B and Office #3056C and all associated items. 4.Addition of sliding glass reception windows and wall modifications near existing Check-in/Check-out #3041 and all associated items. 5.Removal of reception desk and flooring within existing Waiting #3043 and all associated items. 6.Replacement of carpet and resilient base through out all passages. Refer to finish plan. DAVID ARCHI T E C T R E G I S TERE D AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS COMMISSION NUMBER DATE SHEET NUMBER SHEET TITLE CERTIFICATION The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 1715 MAGNAVOX WAY FORT WAYNE, IN 46804 voice 260.432.9337 930 NORTH MERIDIAN INDIANAPOLIS, IN 46204 voice 317.917.1190 http://www.msktd.com ARCHITECTURE ENGINEERING INTERIOR DESIGN 6278 10-22-13 North Hospital IUHP Women's Health 10/22/2013 10:14:14 AM Finish Plan and Schedule A11.1 11 725 Il l in ois St r eet , M OB S ui t e 350 I Ca rm e l , I nd i an a 4 603 2 IUHP WOMEN'S HEALTH ROOM FINISH SCHEDULE Room No.Name Floor Base Walls WallsWallsWallsCeiling Type (see RCP for heights)RemarksNESW 3001 Passage EXT-CPT ------------1 3003 Staff Toilet VCT-1 RB-1 PT PT PT PT ---- 3006 Passage EXT-CPT ------------1,2 3009 Dict EXT-CPT ------------1,2 3013 Passage EXT-CPT ------------1,2 3014 MD Lounge CPT-1 RB-1 PT PT PT PT ACT-1 -- 3020 Passage EXT-CPT ------------1 3021 Files EXT-CPT ------------1 3022 Scales EXT-CPT ------------1 3026 MD Dict EXT-CPT ------------1,2 3033 Passage EXT-CPT ------------1,2 3039 Passage EXT-CPT ------------1 3040 Passage EXT-CPT ------------1 3041 Check-in (2) & Check-out (2)EXT-CPT,CPT-1 ------------3 3043 Waiting EXT-CPT,CPT-1 WD-1 ----------3 3047 Staff Break VCT-1 RB-1 PT PT PT PT ACT-1 3 3049 Passage EXT-CPT ------------1,2 3054 Passage EXT-CPT ------------1,2 3056ANST #1 CPT-1 RB-1 PT PT PT PT ACT-1 3 3056BNST #2 CPT-1 RB-1 PT PT PT PT ACT-1 3 3056COFFICE CPT-1 RB-1 PT PT PT PT ACT-1 -- 3061 Meds CPT-1 ------------1 3073 Work Room CPT-1 RB-1 PT PT PT PT --3 3077 Passage CPT-2 ------------1 3083 Passage CPT-2 ------------1 Finish Color LegendGeneral Finish Remarks Specific Finish Remarks 1/8" = 1'-0" Third Floor Finish Plan Lump Sum Bid Breakouts Revisions:Date:By: