Loading...
HomeMy WebLinkAbout05080255-Site Plan r F~ R.H. of Jfldioflo Lot ~ ,31 . containing 5.895 S.F.+, in' Stenferd Perk 3416 WINDY KNOLL LANE (70'R/~ Prepared Date: 08/19/05: By: JKt ,NVENTOR Community R,estrictions: Side Yard :3 min. Rsar Yard = N/,A, ^ggregete = 6 (BJL) R,H. of Indiana Finished Floor Elevation Information Pod &'ode = 920.6 par Pod Orade + 0,7' = ~rage FF£ (92t,3 Oar~gs FJ:£ + 1,5' = ,Residemfa FF£ (922,8) Rsuid~ntOI FFE - 9.0 = Boserasnf FF£ (913.8) Note,: ]he garege finiched floor elewUo~ is 1.4 shove the curb at the drive par plan. Plot Plan Legend _ []~ Proposed &'odes 000.0 Existing Orades ~----000.0--~- Contour &'ode ~< Approx. Lotaral Location v Water Sunice Lines ....... Sub-Surface Drain Lines _~ Manhole (Sonit. ory or Storm) 9 Beehive Inlqt (Storm) [] Curb Inlet (S.t~n) D End Section (Storm) Hydrant -- -- -- Row L~e of swale .... Building Line (BI. / BSL) ....... £asernsut Line Note: Sanitary Sewer Top of Casting isfarmotion Upstream Manhole, TC=g18,20 Downstreorn Manhole, TC=920.50 per plan. Sidewalk to be I~aond 7' free property line, 5' from back of cum. per pla]. Ground Cover Calculations Drive = 599 Public Walk =129 Private Walk ~-43 SF+ Hydrosesdis9 =N/A SF'+ Sod =363 SY+ . from EN11RE YARD. Detail of ~nd/Storm Note: Per Ca*reel zoning ordinance 26.1.t: 1'ne positive drainage away res~ont~ dis~ct limits height to twont~flve feel from structure(s), (25'), however a dwelling may be increased in height to thirty-five feet (35') Fovided the olde ~3d rear y~ds are increased on adeitionel one foot (1') for each one foot (1') the structure exceons the t~st twenty--fi~ feet ~25') in height. Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey, The Schneider Corporation dons not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found or this drawing should be reported to 'Ihs Schneider Corporation immediately; foiling to do so results in the contractors assumption of ail liability, Note the baseeont ele'~tion, depicted hereon, has b~n detmmined ~'ld I~sed upon the pad grades and/or cm~tonrs t~ke~ free the construction pl~s f~ this subaivtslon. Unisss stated, no information shout ~ctonting water tables, soil conditions, ar soil t~pes nos bee~ provided or stored on said plans, It is recommeaded that the b~.,se~,ont ~ished floor devotions he at least two feet (2) shove [he no~ndi pool eisvetion of any edjoinin9 bodies or water, urdass o study of facts reveals otherwise, If during the excavat~ process any Found water is witnessed. ]he Schneider Coq)oration should be notified Jmmedistdiy, The basement elevation should be roiesd two feet (2~') above tho gr~nd water and oddtUondi constructtoa techniques should be iecarparated to alievinte future prshinms. Note: Sump pump(s) to be pl~ced by # 31 VB05.003 037 TC~gl&20 PI~ PLAN distaece of te~ feet (10') between the FLOOD HAZARD STATEMENT CERTIFICATION S0303 s