Loading...
HomeMy WebLinkAbout34 s2.1 W Carmel5 1 1 1 1 1 1 1 1 6�� VENEER, SEE ARCH � VENEER, SEE ARCH 2x6 PT SILL PLATE W/ 18" AB, SPACING BASE FLASH ; CONTINUOUS #4 VENEER BEYOND, 2x6 STUDS 16" OC W/ PER HEAR WALL HED. 4.1 TO WEEPS @ � ��� � �� SEE ARCH @ S SC S �� 24" OC ; 1-8 x1 -8 #4 DOWEL @ 16 OC SHEATHING PER SW SCHED BASE FLASH TO WEEPS @ 32 OC 2x6 BUILT-UP COLUMN CONC SLAB, EXTERIOR CONC SLAB ON ; ; ; „ EXP. FILLER = A.B. PER SHEAR WALL SCHED. S4.1 4 CONCRETE SLAB 2x6 PT PLATE ; SEE PLAN GRADE, SEE PLAN SEE 1/S1.1 EXTERIOR CONC SLAB ON = EXPANSION JOINT TOC GRADE, SEE PLAN TOC FINISHED FLOOR EXTERIOR CONC SLAB ON SEE PLAN x x x x SEE PLAN x x x �� „ ; GRADE SEE PLAN i i � 2x STUDS @ 16 OC SEE PLAN ; ' � � � � - �;� � ,, w� N l� SLOPE 2% 0-' � � � �'�:� � Z CONCRETE SLAB, 2x PT SILL PLATE WITH ' � • • • ��� w � � � ' ' #5@32"OC � � � O z cn SEE PLAN AB PER S1.1 •• •• w� = O 6" CMU, �� R-10 PERIMETER INSULATION w w �� �+�� � � ���� ���� ' � � `� � � Z „ � w 0 12 CMU, GROUT SOLID w GROUT SOLID #5 @ 32" OC � Z TOC � O _ o� c n x x x x� x x x x S E E P L A N 8" C M U, G R O U T S O L I D W/ � w W/ 3# 5 T O P � Z 12" CMU - GROUT SOLID W/ � Q �� 2-#5 @ TOP p� p z 3-#5 TOP �� G� � z CONCRETE FOOTING, � J @ z # 5 3 2" O C W/ H O O K, � Z S E E P L A N �� — o ; @ p �� ; B O T H E N D S � J z o N R E T E F T I N, � � � S E E P L A N . . . CONCRETE FOOTING, ' 12" x 24" CONCRETE z o ' � z • • • SEE PLAN , FOOTING W/ 3-#5 CONT. � • • • � � '� � & #3 @ 48" OC TRANS. � ; J ; , � 3" CLR V ' , J � � ; V U M J M ; U � `r' �'' 3" CLR SCALE: NTS SCALE: %4"=1'-0" 0" 8" 16" 32" SCALE: NTS SCALE: NTS � � TRUE 'SOF-CUT' STRAIGHT �� �� LINE. SEE NOTE 5. , , ; � CL COLUMN & FTG � � T/4 (1" MIN) , Q- Q- � , � �O �O , , ; �o �o D= 4d FOR #5 & SMALLE ; SEE BAR BENDS BELOW x x x x x � NOTE: ; FOR #6 & LARGER 1. CONTRACTOR'S OPTION, SAW CUT OR POUR STOP ; WD POST, SEE SLAB REINF- CENTERED IN SLAB, , PLAN D= 6d FOR BARS SEE PLAN 2. SEE GENERAL NOTES AND GEOTECH REPORT (AS AVAILABLE) FOR = SMALLER THAN #9 d d SUBGRADE PREPARATION BEFORE PLACEMENT. CONFLICTS BTWN � SAW CUT CONTROL JOINT THE TWO SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION OR ; D D 8d FOR #9, #10 AND #11 THE STRICTER CRITERIA SHALL BE USED. ' AB U 66 POST BAS E #3 15" 12" � � BARS CONNECTION W/ %2"� EXP #4 20" 15" 4d 2%2" MIN TRUE STRAIGHT LINE 3. UNO ON PLAN, PROVIDE SLAB JOINTS ON ALL COLUMN LINES, UNDER , , ; ANCHOR 10d FOR #14AND #18 PARTITIONS AND AT A MAX SPACING OF 12'-0" EA WAY IN BETWEEN. ; #5 25" 19" FIRST POUR SECOND POUR ; �� �� Z BARS �� PROVIDE SLAB JOINTS AT ALL RE-ENTRANT CORNERS. CI PC SLAB, ; #6 30 23 — 1 x2 CONT KEY OR EQ, STOP REI N F 1 � CLR OF JOINT EA SIDE 4. JOINT LOCATION TO BE APPROVED BY ARCH SEE PLAN � TOC #7 35" 28" N ' O x x x , x x x x SEE PLAN #$ 40" 32" r D � ( 5. ALL SAW CUT JOINTS SHALL BE 'SOF-CUT' SAWN AS SOON AS ; d � x x x x ALLOWED BY SAW MFR RECOMMENDATIONS. JOINTS SHALL BE MADE #9 WITHIN 4 HOURS IN HOT WEATHER & WITHIN 12 HOURS IN COLD , - - , ; - - SLAB REINF- CENTERED IN SLAB WEATHER AFTER SLAB FINISH COMPLETED. , #10 , � ' „ _ _ o o SEE PLAN 3 CLR #11 90 BEND 180 HOOK POUR STOP CO N C FTG, � � � � D= BAR D IAM ETE R d= BAR D IAM ETE R SEE PLAN � � KEYED N TRU TI N J INT - - SCALE: %4"=1'-0" 0" 8" 16" 32" SCALE: NTS SCALE: 3�4��=1'-0" 0" 8" 16" 32" SCALE: NTS ���2) ���2) NOTE: 1. CONTRACTOR TO VRFY FTG STEP LOCATION ACCOMMODATES BLOCK OR PANEL MODULES . 2. INDICATES MIN REBAR LAP LENGTH, SEE � • ^ "TYPICAL REBAR LAP SCHEDULE" N N `� ADDL 2-VERT BARS @ `� ICF, MASONRY, OR CONC WALL, REINF PER LEGEND REINF PER LEGEND CORNERS, TYP SEE PLAN ���`��� ry���� � � ��� ��/ K� $a A ry o'�x K EXPANSION JOINT FILLER- SQUARE POLE PAINTED TO TYP WHERE WALK ABUTS MATCH EXISTING GROUT SOLID, TYP GROUT SOLID, TYP +��� BLDG HANDHOLD W/GROUND TYP HORIZ BARS TYP HORIZ BARS LUG BEHIND = 00 � -2�� -2�� CONC FTG N ' "�'� � rS °�`'� � a,� � SEE PLAN y��� t� y� y°� ° � r � �g p °�'�x '� ���° � r�ga� �$ a v � a �+ % -ry NOTE: ADDL REBAR REQD TO ADDL REBAR REQD TO 1. INDICATES MIN REBAR LAP LENGTH, (2) MATCH WALL REINF MATCH WALL REINF o SEE REBAR LAP SCHEDULE �� MATC PER SCHEDULE PER SCHEDULE SLOPE 1:20 MAX � � BUSHING 2. SAME SIZE AND SPACING AS `" � REINF ° BASE COVER HORIZONTAL BARS � SEE PLAN FOR S E N D WALL � 3" c�R, �rP CORNER PLATE LOCATION $c �AM BS -0t GROUT BASE _�„ SCORE JOINT - SEE 1" CHAMFER FOUNDATION PLAN �� �� �� �� �� �� �� �� - SCALE: NTS i i i i 4-3/4"x17" STEEL ANCHOR SCALE: NTS SCALE: NTS SCALE: NTS � BOLTS WELDED TO REBAR ASSEMBLY. TOW 1'-6" FINISH PAVING SEE ARCH OR GRADE FDN. WALL MIN BACK FILL & FTG � PIPE 2 4x4 P.T. WD POST � �� 1 NON-BEARING WALL � \ N � DETAILS � ii W TU D 24" , SEE ARCH NO EXCAVATION BELOW #3 19" ��: I I �: PT SILL PLATE = CONDUIT TO CONDUIT THIS LINE #4 24" I I .21,8"� SHOT PIN @ � - Z 4" CONC SLAB 32 OC (ICBO#1147) � NEXT FIXTURE ____,_ #5 30" — � � CONCRETE SLAB OR #1639. W/ 1%2" MIN. OR PANEL „ IF PIPE IS MORE THAN � Q o I I ON GRADE, SEE PLAN PENETRATION 18 DIA. CONCRETE 2'-6" BELOW BOTTOM � #6 36" � w � SONOTUBE LEAVE 00 � � OUT FORM FOOTING - REINF OF FTG DROP FTG & z #7 54" � w W/ 4-#4 VERT AN D � � m � � PASS PIPE THRU. FDN. x x x x x x x x x #3 TIES @ 6" O.C. W A � � � # g 6 2�� c'� � � � PIPE � 12"Q� CONCRETE FTG � � � � `Y' � 1. 4000 PSI CONCRETE CLASS 'B' LAP L J � PIPE TO CLEAR SLEEVE � BY 1/2"ALL AROUND z 3", TYP _ � � M CONC. FILL TO BE IN � PLACE BEFORE FTG IS � �� ' POURED ° „ - 9 MIN 1 2 SCALE: %4"=1'-0" 0" 8" 16" 32" SCALE: 3�4��=1'-0" 0" 8" 16" 32" SCALE: NTS SCALE: NTS SCALE: %4"=1'-0" 0" 8" 16" 32" '