HomeMy WebLinkAboutLS.2 LIFE SAFETY PLAN.pdfProject Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: GU A R D I A N W E L L S & S U I T E 7 6 Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - S u i t e 7 4 & 7 6 72 2 S o u t h R a n g e l i n e R o a d COPYRIGHT & OWNERSHIP OF DOCUMENTS N 19 R @ 6 2 5 / 3 2 " = 1 0 ' - 8 3 / 4 " 18 T @ 1 1 2 9 / 6 4 " = 1 7 ' - 2 3 / 6 4 " UP SCALE: 1/128"= 1'-0" KEY PLAN SUITE 74/76 PEDCOR DESIGN GROUP, L.L.C. LS.2 LIFE SAFETY PLAN MC AJR9/10/2013 STATE RELEASE SET: 9/10/2013 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013 JAMES R. STUTZMAN, AIA, Carmel, Indiana. N GUARDIAN WELLS & SUITE 76 LIFE SAFETY & CODE SUMMARY PROJECT SUMMARY This project is a new tenant improvement project known as the Guardian Wells & Suite 76, occupying 4,399 square feet of the lower level floor of an existing Shell and Core project known as Carmel City Center. Guardian Wells & Suite 76 is a Group B occupancy, and the construction type is I-A. The entire facility is fully protected by an automatic sprinkler system, and is surrounded by at least 30 feet of yard depth. The Guardian Wells & Suite 76 tenant is a Business Occupancy providing an office facility for the residents of Carmel. APPLICABLE CODES & STANDARDS Indiana General Administrative Rules (675 IAC 12) 2006 Indiana
Building
Code
(IBC
2006)




2008 Accessibility‐Indiana
Building
Code
(ANSI
A117.1‐2003)
2008 Minimum
Design
Loads
for
Buildings
(ASCE
7‐2005)
2008 Indiana
Plumbing
Code
(UPC
1997)

1999 Indiana
Mechanical
Code
(IMC
2006)




2008 Indiana
Electrical
Code
(NFPA
70‐2008)
2009 Indiana
Fuel
Gas
Code
(IFGC
2006)




2008 Indiana
Fire
Code
(IFC
2006)

























































































2008 Indiana
Energy
Conservation
Code
(ASHRAE
90.1
2007) 2010 NFPA
10-2002
Portable
Fire
Extinguishers 2006 NFPA
13‐1999
Installation
of
Fire
Sprinkler
Systems




2002 NFPA
72‐2002
National
Fire
Alarm
Code 2006 NFPA
90A‐
Installation
of
Air
Conditioning
&
Ventilating

Systems
1999 NFPA
90B
—
Installation
of
Warm
Air
Heating
&
Air
Conditioning
Systems



1999 Americans
with
Disabilities
Act
(2010
Standards
for
Accessible
Design)

2010 OCCUPANCY CLASSIFICATIONS: Guardian Wells & Suite 76 Tenant: Group B Building Shell & Core: Group A-2, A-3, B, M, R-2 Parking Garage: Group S-2, B, M OCCUPANT LOAD Guardian Wells Total Gross Area 1,392 sq ft B Occupancy @ 100 sf/person 13 persons Suite 76 Total Gross Area 3,007 sq ft B Occupancy @ 100 sf/person 30 persons CONSTRUCTION TYPES: Office Space Tenant: Type I-A Upper Building Shell & Core: Type I-B Parking Garage: Type I-A BUILDING AREAS: Guardian Wells & Suite 76 Tenant: 4,399 sf Shell & Core: (Total Building A) 309,587 sf FIRE RESISTANCE Office Space Tenant & Shell & Core (Ground Floor): Walls: All construction to be non-combustible Exit Passageways: 2 hours Fire walls: 2 hours Exit Access Corridors: 1 hour Ceiling: 3 hours INTERIOR FINISHES Office Space Tenant & Shell & Core (Ground Floor): Vertical Exits & Passageways: Class B Exit Access Corridors Class C All Others Class C FIRE PROTECTION 100% protection by an automatic sprinkler system per NFPA 13-1999 100% protection by a fire alarm & enunciator system meeting NFPA 72-2002 Sprinkler fire pump and backup power meeting NFPA 20-1999 Stairway pressurization meeting IBC 2008 and NFPA 92A-2002 ACCESSIBILITY REQUIREMENTS All tenant restrooms comply with ICC/ANSI A117.1-2003; Section 604.5.1; and 2010 ADA PREVIOUS IDHS APPROVALS Project No. 317769 CDR Letter Foundation Release 04.25.06 Project No. 317796 CDR Letter Standard Release - Architectural & Structural 06.19.07 19 R @ 6 2 5 / 3 2 " = 1 0 ' - 8 3 / 4 " 18 T @ 1 1 2 9 / 6 4 " = 1 7 ' - 2 3 / 6 4 " UP TEMPORARY CONSTRUCTION BARRIER. REST ROOM 109 SUITE 76 REST ROOM 113 SUITE 76 OPEN OFFICE 112 HALLWAY 105 73'-11" STOR. CLO. 1 SUITE 76 OFFICE 111 REST ROOM 108 CONFERENCE ROOM 101 OFFICE 107 OFFICE 103 COFFEE BAR 102 COPY/IT ROOM 104 STORAGE CLOSET 110 CONFERENCE ROOM 106 RECEPTION 100 49'-5" GUARDIAN WELLS 1,392 SQUARE FEET 13 OCCUPANTS SUITE 76 3,007 SQUARE FEET 30 OCCUPANTS MEANS OF EGRESS DURING CONSTRUCTION TENANT OCCUPIED SPACE 24.1 24 23.1 23 22 21.9 23.6 25 R SR.1 R.2 R.3 R.5 R.6Q.2 Q.5 SCALE: 1/4" = 1'-0" 2 LIFE SAFETY PLAN LS.2