Loading...
HomeMy WebLinkAboutA1.3 REFLECTED CEILING PLAN.pdfProject Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: GU A R D I A N W E L L S & S U I T E 7 6 Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - S u i t e 7 4 & 7 6 72 2 S o u t h R a n g e l i n e R o a d COPYRIGHT & OWNERSHIP OF DOCUMENTS N 19 R @ 6 2 5 / 3 2 " = 1 0 ' - 8 3 / 4 " 18 T @ 1 1 2 9 / 6 4 " = 1 7 ' - 2 3 / 6 4 " UP SCALE: 1/128"= 1'-0" KEY PLAN SUITE 74/76 PEDCOR DESIGN GROUP, L.L.C. A1.3 REFLECTED CEILING PLAN MC AJR9/10/2013 STATE RELEASE SET: 9/10/2013 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013 JAMES R. STUTZMAN, AIA, Carmel, Indiana. N ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. GENERAL CEILING NOTES:CEILING PLAN NOTES: PROVIDE FIRE RATED DAMPERS WHERE REQUIRED AT FIRE RATED WALLS. EMERGENCY STROBES TO BE WHITE AND EMERGENCY LIGHT FIXTURES TO BE WHITE UNLESS NOTED OTHERWISE. COORDINATE IN THE FIELD WITH THE ARCHITECT AND TENANT. INSTALL ACOUSTICAL CEILING PANELS WITH GRAIN/TEXTURE RUNNING IN THE SAME DIRECTION UNLESS NOTED OTHERWISE. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. COORDINATE ALL SWITCHING AND LOCATIONS WITH THE TENANT AND ARCHITECT. LIGHTING TIMER IS TO BE PROVIDED TO MEETING ENERGY CODE. CP1 11. 10. 9. 8. 5. 6. 7. 4. 1. 2. 3. HVAC DIFFUSERS AND GRILLES, FIRE SPRINKLERS ARE TO BE CENTERED WITHIN CEILING TILES. REFLECTED CEILING LEGEND: ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE. PROVIDE AND INSTALL TIMER CONTROL SYSTEM. ALL LIGHTS NOT CONTROLLED WITH OCCUPANCY SENSORS ARE TO BE CONTROLLED ON THE TIMER. COORDINATE CIRCUITS AND SWITCHING WITH THE ARCHITECT. PROVIDE DIMMERS IN THE CONFERENCE ROOMS. CP3 CP4 12. BLOCKING AND SUPPORTS ARE TO BE PROVIDED FOR ALL CEILING MOUNTED FIXTURES AS NEEDED. 13. LIGHTING CONTROLS. 2' X 2' SUSPENDED CEILING TO BE: ARMSTRONG, 2'X2' DUNE ANGLED TEGULAR, W/ PRELUDE XL 15/16" GRID. EXHAUST GRILLE IN CEILING FOR USE WITH BUILDING'S EXHAUST SYSTEM. FIRE PROOFING IS TO BE REMOVED FROM THE DECK AND OTHER ITEMS IN OPEN CEILING AREAS THAT ARE NOT NEEDED TO BE FIRE PROOFED. 14. PROVIDE OCCUPANCY SENSORS IN THE OFFICES, CONFERENCE ROOMS, RESTROOMS, COPY/ IT ROOM, AND BREAK AREA. 15. MEP CONSULTANT TO RUN THE NECESSARY CALCULATIONS TO DETERMINE THAT THE LIGHTING LAYOUT MEETS THE ENERGY CODE. IF IT DOES NOT PLEASE ADDRESS THIS WITH THE ARCHITECT AND THE TENANT TO REVISE LIGHT SELECTIONS AS NEEDED. MEP CONSULTANT IS TO SUBMIT DRAWINGS SHOWING LOCATIONS OF ALL NECESSARY HORN STROBES, FIRE PULLS AND EMERGENCY LIGHTS. CP2 PROVIDE SEPARATE CIRCUIT ON A TIMER FOR THE LIGHTS IN THE RECEPTION AREA AND HALLWAY. ALL LIGHT FIXTURES TO BE 3500K COLOR TEMPERATURE. PROVIDE EXHAUST VENT TIED INTO THE BUILDINGS EXHAUST SYSTEM IN THE RESTROOMS.CP5 PROVIDE HVAC DISTRIBUTION FROM EXISTING HEAT PUMP UNITS. DISTRIBUTION TO CONSIDER THE GROUPING OF SIMILAR ROOMS, LIKE THE RECEPTION AREA AND THE CONFERENCE ROOMS. CONSIDER THE USE OF A SEPARATE VOLUME CONTROL FOR THE SMALLER CONFERENCE ROOM IF GROUPED WITH THE LARGER CONFERENCE ROOM. REVIEW THE CONTROLS FOR THE EXISTING BASEBOARD HEATERS AND REPLACE THEM AS NEEDED TO ALLOW EASY USE BY THE TENANT. CONSIDER THE USE OF DUCT HEATERS FOR THE UNIT SERVING THE BACK AREA OF THE SUITE. CP6 PROVIDE EMERGENCY LIGHTING, SMOKE DETECTORS, AND LIFE SAFETY ITEMS AS REQUIRED.CP7 PROVIDE DRYWALL BULKHEAD @ 10'-0" AFF OR MATCH EXISTING.CP8 SYMBOL TYPE A LIGHT FIXTURE SCHEDULE RECESSED DOWNLIGHT MODEL CREE, 6" LED RECESSED DOWNLIGHT, LR6C-10L-DIMMABLE, 3500K W/RC6 HOUSING. WATTAGEDESCRIPTION MOUNTING HEIGHT NOTES B LAY-IN FLUORESCENT FIXTURE 64W D FERGUSON, FEISS SUNSET DRIVE MID SIZED CHANDELIER, MF24055CB W/ (5) 60W LAMPS 100WENORA LIGHTING, NH-26Q, NTA-97 W/ 100W A19 LAMP. F MERCURY LIGHTING, MIE6-2-32-OCT-8T-10%-ELB- UNI-TILW-VH. CEILING CEILING 64W C 200WPENDANT LIGHT FIXTURE CHANDELIER LIGHT FIXTURE RECESSED DOWNLIGHT LINEAR LIGHT FIXTURE 300W 12W CEILING MERCURY LIGHTING, 2X2 LAY-IN FLUORESCENT, 54E-2-32-OCT-U6-9-ELB-UNI. FERGUSON, FEISS SUNSET DRIVE DRUM PENDANT, MF24043CB W/ (2) 100W LAMPS DIMMABLE IN CONFERENCE RMS. 7'-0" TO BOTTOM OF FIXTURE. 8'-0" AFF TO BOTTOM OF FIXTURE MERCURY LIGHTING, EDGE LIT LED EXIT SIGNS, MER-ELXTE - RED LETTERS, CLEAR FACE, WHITE HOUSING. EMERGENCY EXIT SIGNS -- MERCURY LIGHTING, LED LOW PROFILE EMERGENCY LIGHT, MER-LEDR1 - WHITE.EMERGENCY LIGHTS -- 16. EXISTING CEILING/BULKHEAD AND LIGHTING TO REMAIN. CEILINGS ARE TO BE OPEN WITH ALL EXPOSED HVAC UNITS, DUCTWORK AND CONDUIT TO BE PAINTED. CP9 NOT USED.CP10 TIE EXISTING BULKHEAD LIGHTS INTO NEW LIGHTS WITHIN THE ROOM.CP11 CEILING TO REMAIN OPEN WITH ALL EXPOSED SURFACES TO BE UNFINISHED. EXISTING HVAC UNIT TO REMAIN WITH NO DISTRIBUTION ADDED. CP12 REMOVE EXISTING LIGHT FIXTURES AND SAVE FOR REUSE.CP13 INSTALL REMOVED LIGHT FIXTURES OR FIXTURES FROM STORAGE AS SHOWN.CP14 PROVIDE SEPARATE CIRCUIT ON A TIMER FOR THE WINDOW DISPLAY LIGHTS.CP15 PROVIDE 3-WAY SWITCH FOR ALL LIGHT FIXTURES IN THE OPEN OFFICE AREA.CP16 PROVIDE DUCT FROM EXISTING HVAC UNIT TO SUPPLY THE PRIVATE OFFICE.CP17 DIMMABLE 8'-0" TO BOTTOM OF FIXTURE. 2' X 2' SUSPENDED CEILING TO BE: ARMSTRONG, 2'X2' ULTIMA HEALTH ZONE CREATE! SQUARE LAY-IN PANELS, WOOD LOOKS - OAK W/ PRELUDE XL 15/16" GRID PAINTED IN FIELD TO MATCH CEILING. PROVIDE LINE ITEM TENANT COST. PROVIDE ARMSTRONG, AXIOM, 2" STRAIGHT, WHITE, CLASSIC TRIM ON BOTH SIDES OF THE SUSPENDED CEILING SYSTEM. CP18 PROVIDE ARMSTRONG, AXIOM, 2" STRAIGHT, WHITE, CLASSIC TRIM. PAINT TO MATCH CEILING GRID. CP19 EXISTING LIGHT AND GRID TO REMAIN.CP20 PROVIDE LIGHTING CONTROL TIMER AT THIS LOCATION.CP21 EXISTING EXISTING A1 RECESSED DOWNLIGHT CREE, 6" LED RECESSED DOWNLIGHT, LR6C-10L-DIMMABLE, 3500K IN EXISTING A19 HOUSING. CEILING12W RETROFIT REMOVE ALL EXISTING LIGHT FIXTURES IN SUITE 74, EXCEPT IN REST ROOM 109. SAVE FOR LANDLORD'S REUSE. 17. 19 R @ 6 2 5 / 3 2 " = 1 0 ' - 8 3 / 4 " 18 T @ 1 1 2 9 / 6 4 " = 1 7 ' - 2 3 / 6 4 " UP L L L L L 2' - 0 " 2' - 0 " 2'-0"2'-0" EQ.10'-0"EQ. EQ . 12 ' - 0 " EQ . 8'-0" 8'-0" OPEN OPEN OPEN 8'-0" 9'-6" 10'-0" 10'-0" 11'-0" 8'-0" 8'-0" 8'-0"8'-0" 8'-0" 8'-0"8'-0" OPEN OPEN 10'-0" OPEN OPEN OPEN 14 A4.1 CP1 CP18CP9 CP8 CP3 CP4 CP6 CP7 CP1 CP2 CP3 CP6 CP3 CP6 CP7 CP3 CP6 CP9 CP11 CP2 CP6 CP7 CP9 CP3 CP4 CP6 CP7 CP3 CP5 CP7CP3CP5CP7 CP3 CP6 CP7 CP3 CP6 CP7 CP3 CP7 CP12 CP14 CP17 CP7 CP12 CP16 CP13 CP13 CP16 CP14 CP11 CP1 CP15 CP1 CP17 CP11 CP20 CP20 CP19 CP20 CP21 TEMPORARY CONSTRUCTION BARRIER. A C D B BB BB B B B B B B D D D D 3 3 F A A A A A A A A A A A A A A A A A A A A A A B B B B C C A1 E E E F B B D B B D F FFF FFF F F A1 A1 A1 TENANT OCCUPIED SPACE N N 24.1 24 23.1 23 22 21.9 23.6 25 R SR.1 R.2 R.3 R.5 R.6Q.2 Q.5 SCALE: 1/4" = 1'-0" 1 REFLECTED CEILING PLAN A1.3