Loading...
HomeMy WebLinkAboutA101B Sixth Floor - Floor Plan 605.PDFProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CA R M E L C I T Y C E N T E R Ca r m e l , I n d i a n a Bu i l d i n g A Pe n t h o u s e I n t e r i o r s COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 A101B Sixth Floor - Floor Plan 605 Bid Set ##/##/#### THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL ANDUNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2011JAMES R. STUTZMAN, AIA, Carmel, Indiana. SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A NOT FOR CONSTRUC TION Fr i d a y , S e p t e m b e r 2 7 , 2 0 1 3 ; A L L D A T A : M S : D E S I G N : P R O J E C T S : C A R M E L C I T Y C E N T E R : C C C D r a w i n g s : C C C C o n s t r u c t i o n D o c : B u i l d i n g A : A . 5 0 0 : P E N T H O U S E C D s : P e n t h o u s e T e n a n t s : U N I T 6 0 3 - 6 0 5 F u l l e r : 0 9 0 3 1 3 . p l n N 27 26.5 26 24 25 27 26.5 26 24 25 ALIGN FINISHED FACES. PLAN NOTES: FP1 FP2 FP3 FP4 FP5 FP6 FP7 FP8 FP9 FP10 LOCATE NEW WALL FRAMING SO THAT STUDS ARE TIGHT TO THE STRUCTURAL COLUMNS OR PLUMBING. EXTERIOR GAS HOOK-UP FOR FUTURE EXTERIOR RANGE. PROVIDE DRY PENDANT FIRE PROTECTION PIPE ON WALL ABOVE GAS HOOK-UP. FROST PROOF HOSE BIB. PROVIDE ALL PLUMBING STUBBED AND DISTRIBUTED READY FOR BUYER PROVIDED AND INSTALLED FIXTURES. CAP FEEDS AND INCLUDE SHUT OFF VALVES. PROVIDE PLUMBING AND INSTALLATION OF SHOWER DRAIN, WATERPROOFING AND SLOPED MUD BASE READY FOR TILE. PROVIDE SEPARATE LINE ITEM BUYER COST. GENERAL NOTES: 1. 2.REFERENCE THE WALL LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. ALL WALL CONSTRUCTION TO BE S3.5B, UNLES S NOTED OTHERWISE. ALL WALL CONSTRUCTION AT COLUMNS PILASTERS TO BE S3.5A UNLESS NOTED OTHERWISE. 3. 5. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 6. RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH ARCHITECT. 4. NEW DOOR AND FRAME SYMBOLS CORRESPOND TO DOOR/FRAME/HDWR TYPES AS LISTED ON THE DOOR/FRAME/HDWR LEGEND. 7. 8. 9. APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 10. 11. 12. ALL NEW DOORS TO BE INSTALLED WITH HINGE 4" MINIMUM AWAY FROM WALL. 15. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF TOP LAYER OF SOUND ISOLATION SYSTEM AND NEW FLOOR FINISHES BY BUYER. 13. 14. ALL WALLS INDENTIFIED ON THE ARCHITECTURAL SHELL PACKAGE (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. MOISTURE & MOLD RESISTANT GYPSUM BOARD TO BE USED WITHIN ALL BATHROOMS. 17. ALL WALLS SHALL BE CHALKED OFF FOR ARCHITECT'S REVIEW OF NEW WALL CONSTRUCTION. COORDINATE CLEARANCE AND ACCESS FOR MECHANICAL UNITS WITH MECHANICAL DESIGN/ BUILDER. CONTACT ARCHITECT TO COORDINATE ISSUES. DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD UNLESS NOTED OR SHOWN OTHERWISE. TUBS AND SHOWERS AT WALLS W/ (2) LAYERS OF DRYWALL ARE MEASURED TO THE 1ST LAYER OF DRYWALL. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT. DO NOT SCALE DRAWINGS. 18. 19. WALL TAG "SXXX + XX AFF" IDENTIFIES HEIGHT OF NEW LOW WALL CONSTRUCTION ABOVE FINISHED FLOOR. PROVIDE METAL KNEE BRACES AT UNSUPPORTED ENDS OF WALL. 20. ALL EXISTING BUILDING SHELL WALLS ARE DENOTED WITH SOLID FILL. VERIFY THE PRESENSE OF INSTALLED INSULATION AND GYPSUM SHEATHING AT EXTERIOR WALLS, DEMISING AND CORRIDOR WALLS. VERIFY INSULATION AT WALL OPENING JAMB STUDS. INSULATE WALLS WHERE LEFT VOID IN ALL CONDITIONS. WHERE NEW MEP ROUGH-INS OCCUR, INCLUDE DEMOLITION AND NEW GYPSUM BOARD AS REQUIRED AT THESE EXISTING SHEATHING LOCATIONS. 21. ALL INTERIOR WALLS TO EXTEND TO BOTTOM OF FINISHED CEILING UNLESS OTHERWISE NOTED. 22. ALL WINDOWS ARE TO HAVE A MINIMUM 4" OF CLEARANCE FROM ADJACENT WALL. SEE ENLARGED UNIT PLANS FOR DIMENSIONS, WALL TYPES, AND CONSTRUCTION DETAILS. ALL DRYWALL WRAPPED OPENINGS ARE TO BE 3'-0" X 7'-0" (UNLESS OTHERWISE NOTED), CENTERED ON HALL WITH 3" MINIMUM EACH SIDE. NEW PORTABLE FIRE EXTINGUISHERS TO BE PROVIDED IN EACH UNIT. PLACE FIRE EXTINGUISHER IN PANTRY. FIRE ALARM: INTERFACE FIRE ALARM SYSTEM WITH THE MAIN BUILDING FIRE ALARM FOLLOWING REQUIREMENTS FOR HIGH-RISE BUILDINGS PER THE INDIANA BUILDING CODE. PROVIDE A RECEPTACLE NEXT TO ANY DATA LOCATION. ALL WALLS ARE TO BE PRIMED AND PAINTED UNLESS OTHERWISE NOTED. WINDOWS TO RECEIVE WOOD SILL AND STOOL. 23. AT TUBS, SHOWERS AND TOILETS, INCLUDE BLOCKING FOR FUTURE GRAB BARS PER DETAIL 10/A103. USE TESTED FIRE ASSEMBLIES FOR WALL PENETRATIONS AT RATED WALLS AND PARTITIONS WHERE REQUIRED BY CODE. 24. 25. 16. 26.IN ALL BATHS, COORDINATE PLUMBING ROUGH-INS W/ CABINET SUPPLIER. FP11 FP12 IN KITCHENS, PROVIDE 40" MIN. CLEARANCE BETWEEN ALL COUNTERS, BASE CABINETS, APPLIANCES AND WALLS, MEASURED FROM ANY COUNTERTOP OR FACE OF APPLIANCE. ALL EXISTING BUILDING SHELL WALLS ON I SERIES SHEETS ARE DENOTED WITH SOLID FILL. G.C. TO PROVIDE BLINDS AT ALL PERIMETER WINDOWS. PROVIDE DIRECT VENT GAS FIREPLACE TO BE: XXX. PROVIDE (5) SHELVES IN PANTRY, DISH PANTRY, UTILITY, AND LINEN CLOSET OF SAME QUALITY AS 605 UNLESS NOTED OTHERWISE. PROVIDE ADDITIONAL BLOCKING AS REQUIRED. SEE SHEET XXX FOR PATIO RAIL SYSTEM AT NORTH AND EAST FACADE. PROVIDE THE FOLLOWING FOR LAUNDRY CLOSET; (1) 16" DEEP 3/4" PAINTED SHELF ON WALL CLEATS AND CENTER BRACKET ABOVE WASHER AND DRYER. PROVIDE ADDITIONAL BLOCKING AS REQUIRED. PROVIDE SINGLE ROD AND SHELF IN ALL CLOSETS OF SAME QUALITY AS 605 UNLESS NOTED OTHERWISE. PROVIDE ADDITIONAL BLOCKING AS REQUIRED. ANY RECESSED ELECTRICAL BOXES / DEVICES IN DEMISING WALLS BETWEEN SEPARATE APARTMENTS OR CONDOMINIUMS ARE TO BE STAGGERED (SEPARATE STUD CAVITIES) RELATIVE TO ONE ANOTHER TO MINIMIZE ANY SOUND TRANSMISSION BETWEEN UNITS. PROVIDE PLUMBING AND INSTALLATION OF SHOWER DRAIN, FOR MANUFACTURED SHOWER PAN TO BE: TILE REDI, 3636X-PVC SINGLE CURB SHOWER PAN. INSTALL WITH REDI FLASH FLASHING. PROVIDE PLUMBING AND INSTALLATION OF BUYER PROVIDED TUB. SHOWER SHOULD BE WATERPROOF AND READY FOR TILE. PROVIDE SEPARATE LINE ITEM BUYER COST. PROVIDE PLUMBING AND INSTALLATION OF SHOWER DRAIN, FOR MANUFACTURED SHOWER PAN TO BE: TILE REDI, 3760X-PVC SINGLE CURB SHOWER PAN. INSTALL WITH REDI FLASH FLASHING. FP13 ALL WALLS TO BE TAPED, SPACKLED, AND PRIMED READY FOR BUYER TO PRIME, PAINT AND/ OR WALLPAPER. PROVIDE DOUBLE ROD AND SHELF OF SAME QUALITY AS 605 UNLESS NOTED OTHERWISE. PROVIDE ADDITIONAL BLOCKING AS REQUIRED. PROVIDE NICHE IN WALL FOR APPLIANCE GARAGE. SEE DETAIL X/XXX. PROVIDE NICHE IN WALL FOR BUYER PROVIDED AND INSTALLED MEDICINE CABINETS. SEE DETAIL X/XXX. FP14 FP15 FP16 FP18 FP20 FP17 FP19 PROVIDE GRAVITY DRAIN AT OR SLIGHTLY ABOVE FLOOR LEVEL FOR TENANT PROVIDED AND INSTALLED ICE MAKER. PROVIDE PLUMBING FOR A POT FILLER FAUCET AT THIS LOCATION. FILLER PROVIDED BY BUYER. FP21 FP22 PROVIDE PLUMBING FOR DISHWASHER TO BE PROVIDED AND INSTALLED BY BUYER.FP23 S3.5Bi WALL TYPE NOTATION 1. Wall tags with additional dimensional text indicate wall height, such as: Any wall tags without such additional noting are to be assumed to go to underside of structural deck above or as indicated in associated wall sections. 2. Some walls may have more than one wall type tag, signifying that: a. either the wall has a core wall type with additional wall materials required or, b. the wall is a given wall type at the floor (to a certain height), then changes to another wall type above. 3. Any wall type designation showing a letter " i " indicates that insulation is required. See either Schedule and/or specification for wall insulation type required. 4. Any wall sheathing indicated on a wall type shall be exterior sheathing when the wall is used for an exterior wall. This includes porches, mechanical rooms, elevator shafts and machine rooms and parking level spaces. +42" AFF ThicknessPlan View Section View Brief Description WALL LEGEND S2.5A S2.5Ki S3.5A S3.5Ai S3.5Bi S3.5B S3.5Ei S3.5Fi S2.5E S3.5F S6Gi S2.5Ji S3.5E S3.5G 2-1/2" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side; 1" space on one side.4 1/8" 2-1/2" Metal stud wall, min. 16" o.c.;(2) layers of 5/8"gypsum board on one side w/ additional 1-1/2" battinsulation (see specifications for requirements).5 1/4" Lateral Bracing — Right angle- shaped, supplied withnotches spaced 12, 16, or 24 in. OC., friction- fitted tothe cutouts in steel studs, supplied in 7/8 in. by 7/8 in. by 50 in. lengths. Lateral bracing bars fabricated from min. 20 MSG galvanized steel. The bracing shall meet the 1996 Edition of the American Iron and Steel Institute (AISI) "Specification for the Design of Cold- Formed Steel Structural Members. DIETRICH INDUSTRIES INC — TradeReady Spazzer 9200 bar 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side.4 1/4" 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum board on one side, with batt insulation (see specifications for requirements).4 1/4" 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsum boardon both sides. 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" gypsumboard on both sides, with batt insulation (seespecifications for requirements). 4 7/8" 4 7/8" 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side, with batt insulation (see specifications for requirements).4 1/4" 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture andMold Resistant board, on one side, 5/8" gypsum, on oneside, with batt insulation (see specifications forrequirements). 4 7/8" 2-1/2" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board on one side; 1" space on one side. 4 1/8" 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture andMold Resistant board, on one side, 5/8" gypsum, on one side. 4 7/8" 6" Metal stud wall, min. 16" o.c.; 5/8" Moisture and MoldResistant board on both sides, with batt insulation (seespecifications for requirements).7 1/4" 2-1/2" Metal stud wall, min. 16" o.c.;(2) layers of 5/8" gypsum board on one side w/ batt insulation. 3 3/4"Lateral Bracing — Right angle- shaped, supplied withnotches spaced 12, 16, or 24 in. OC., friction- fitted tothe cutouts in steel studs, supplied in 7/8 in. by 7/8in. by 50 in. lengths. Lateral bracing bars fabricatedfrom min. 20 MSG galvanized steel. The bracing shallmeet the 1996 Edition of the American Iron and Steel Institute (AISI) "Specification for the Design of Cold- Formed Steel Structural Members. DIETRICH INDUSTRIES INC — TradeReady Spazzer 9200 bar 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture and Mold Resistant board, on one side.4 1/4" 3-5/8" Metal stud wall, min. 16" o.c.; 5/8" Moisture andMold Resistant board on both sides.4 7/8" GENERAL FINISH NOTES G.C. TO PROVIDE ZINC AND/OR BRASS, TRANSITION STRIP WHERE CARPET AND FINISHES MEET. ALL NEW DOOR FRAMES AND WOOD TRIM TO BE PAINTED, COLOR AND FINISH TDB. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. 1. 2. 3. 4. 5. 6. COLOR TO BE SELECTED BY DESIGNER. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK TO DESIGNER FOR REVIEW AND APPROVAL BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. 3'-0" 8' - 0 " VARIES 7' - 0 " 5'-0" 7' - 0 " 20 MIN. A B C Wall Legend DOOR ELEVATIONS 1/2" = 1'-0" Bid Set #1.1 10.27.10 10.27.10 LGALGA 11.09.11 11.09.11 BANK SET 11.09.11 BID SET 12.15.11 CA R M E L C I T Y C E N T E R - B U I L D I N G A CO N D O M I N I U M U N I T 6 0 5 72 0 S . R a n g e l i n e R o a d Ca r m e l , I n 4 6 0 3 2 P QP.5P QP.5 F R 6'-6 1/2"7'-7 1/4"4'-1 1/8"21'-10 1/2" 2'-5 1/8"3'-7 1/8"12'-2"19'-7 1/2" 10 1/4" 6'-1 1/4"21'-10 1/2" 7' - 2 1 / 2 " 7'- 6 1 / 8 " 3'- 5 1 / 4 " 9' - 1 0 1 / 2 " 2'- 5 " 3' - 1 1 3 / 4 " 5'- 7 1 / 4 " 3' - 1 1 / 4 " 2' - 8 3 / 8 " 11'-7 5/8"7'-0 3/8"21'-9" 6'-2 3/4"5'-1 1/4" 4'- 8 1 / 2 " 3' - 1 3 / 4 " 5' - 1 7 / 8 " 18 ' - 4 7 / 8 " 8 1 / 2 " 3' - 1 1 / 4 " 4 7 / 8 " 7' - 2 1 / 2 " 11 ' - 3 " 9' - 1 0 1 / 2 " 6'- 1 1 / 8 " 7'- 2 1 / 4 " 4' - 6 1 / 4 " 8" 6'- 1 " 4'- 5 5 / 8 " 10 ' - 4 5 / 8 " 4' - 1 1 / 4 " 4'- 8 1 / 2 " 14 ' - 1 1 1 / 4 " 2'-0 1/2" 2'- 4 7 / 8 " 4' - 9 5 / 8 " 3'- 1 1 / 4 " 4' - 0 3 / 8 " 3' - 2 1 / 8 " 8'-4 7/8"2'-11 1/8" 6'-6 1/2"5'-1 1/8"9 5/8" 3'-7 1/4"1'-8 1/4"3'-1 1/4"2'-8 3/8" 10 3 / 8 " 1'-11 3/4" 10 1 / 2 " 1'-11" 6' - 7 1 / 8 " 9' - 1 1 / 4 " 12 ' - 6 7 / 8 " 9'- 1 1 " 13 ' - 0 7 / 8 " 5'-1 1/4"4'-1 1/4"5'-4 5/8"20'-11 3/4" 4'-7 5 / 8 " 2'-2 1 / 8 " 3'-7 1 / 4 " 1'-3 3 / 4 " 5'-10 1 / 2 " 1'-5 1 / 8 " 1' - 6 3 / 4 " 4 7 / 8 " 20 ' - 2 7 / 8 " 8' - 1 0 3 / 8 " 24 ' - 3 3 / 4 " 8'-0"5'-6"5'-4 3/8"2'-6" 1'- 1 1 / 8 " 6'-4 1/2"1'-9 3/4"10 3/4" 5'-4 1/2"1'-0" 8' - 1 7 / 8 " 11'-1 1/8"4'-5 7/8"14'-1 7/8" 7 5 / 8 " 5' - 1 1 / 4 " 7 5 / 8 " 2' - 1 1 / 4 " 1' - 5 1 / 8 " 5'-1 1/4" 9'- 1 1 " 12'-9 1 / 8 " 1'-6 3 / 8 " 11 1/8"7 1/2" 8"6 5 / 8 " 2'-3"2'-3"1'- 1 1 " 125° 125 ° 125° 145° 125 ° FP2 FP6 FP8 FP17 FP20 FP5 FP3 FP1 FP1 FP1 FP1FP1 FP1 FP1 FP1 FP1 FP1 FP1 FP3 FP5 FP5 FP7 FP7 FP8 FP8 FP8 FP8 FP8 FP8 FP8 FP8 FP8 FP8 FP9 FP10 FP11 FP12 FP13 FP13 FP13 FP14 FP14 FP14 FP14 FP15 FP15 FP15 FP15 FP14 FP16 FP20 FP19 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP18 FP21 FP22 FP23 FP23 12 0 S2.5A S2.5E S 2 . 5 A S 2 . 5 A S3.5Bi S3.5 A S 3 . 5 B i 10 4 A 10 3 S3.5Bi 104 S 3 . 5 B i S 3 . 5 B i 10 4 B S3.5Bi S 3 . 5 A S 3 . 5 A S3.5 A S3.5 A S 3 . 5 A S3.5 A S 3 . 5 A S3.5 A S 3 . 5 A S3.5 A S3.5 A S3.5 A S 3 . 5 A 101 S 3 . 5 B i 105 S 3 . 5 B i S3.5A S3.5A S 3 . 5 A S3.5 A S3.5 A S 3 . 5 A S 3 . 5 B 110 S 3 . 5 B S3.5B S 3 . 5 B S1.5A S 1 . 5 A S3.5A S3.5A S 3 . 5 A S3.5 A S 3 . 5 A 10 7 S3.5B S 3 . 5 A S3.5A 111 S 3 . 5 B i S3.5A S 3 . 5 A S3.5A S3.5Bi S 3 . 5 B i S3.5Bi S 3 . 5 B i S3.5Bi S 3 . 5 B i 122 S 3 . 5 B i 12 1 S3.5Bi 114 S 3 . 5 B i S3.5A S 3 . 5 B i 1 11 6 S3.5Bi S 3 . 5 B i S 3 . 5 B i S3.5Bi S 3 . 5 B i 11 9 B S3.5Bi S 3 . 5 B i S3.5A S3.5A S3.5Bi11 9 A S3.5Bi S3.5Bi 118A 119 S3.5A S 3 . 5 A S3.5B S3.5A S 3 . 5 A S3.5Bi S3.5Bi 117 S 3 . 5 B i 11 8 S3.5Bi 118B S 3 . 5 B i S3.5Bi S 3 . 5 A S3.5A S 3 . 5 A S3.5A S 3 . 5 A S3.5A S3.5A S 3 . 5 A S3.5A S3.5A 10 0 S 3 . 5 B i S3.5A S 3 . 5 A S3.5A S 3 . 5 A S 3 . 5 A S3.5A S 3 . 5 A S3.5A S 3 . 5 B i S 3 . 5 A FOYER 100 LIBRARY 114 MASTER BATHROOM 118 CLOSET 117 MASTER BEDROOM 116 BATHROOM 115 LAUNDRY ROOM 120 PANTRY 122 CLOSET 119 LINEN MECHANICAL 111 UTILITY CL. 121 DINING 109 KITCHEN 112 LIVING ROOM 106 BEDROOM 104 GUEST BATH 104B POWDER ROOM 103 CLOSET 104A HALL 102 COATS 101 COATS 105 DISH PANTRY 110 BAR 108 FIREPLACE SITTING 113 STOR. 107 SCALE: 1/4" = 1'-0" 1 FLOOR PLAN A101B 0 2'4'8'