Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A101C Ceiling plan 603-605_2.PDF
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: CA R M E L C I T Y C E N T E R Ca r m e l , I n d i a n a Bu i l d i n g A Pe n t h o u s e I n t e r i o r s COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date PEDCOR DESIGN GROUP LLC 0502.00 A101C Ceiling plan 603-605 Bid Set ##/##/#### THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALLINFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSIONAND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED ASPUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALLINFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL ANDUNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THESPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2011JAMES R. STUTZMAN, AIA, Carmel, Indiana. SCALE: NTS PLAN NORTH 28 22 16 H M AREA A AREA C AREA B R KEY PLAN BLDG A NOT FOR CONSTRUC TION Fr i d a y , S e p t e m b e r 2 7 , 2 0 1 3 ; A L L D A T A : M S : D E S I G N : P R O J E C T S : C A R M E L C I T Y C E N T E R : C C C D r a w i n g s : C C C C o n s t r u c t i o n D o c : B u i l d i n g A : A . 5 0 0 : P E N T H O U S E C D s : P e n t h o u s e T e n a n t s : U N I T 6 0 3 - 6 0 5 F u l l e r : 0 9 0 3 1 3 . p l n N 27 26.5 26 24 25 27 26.5 26 24 25 SD S REFLECTED CEILING LEGEND: JUCTION BOX FOR FUTURE CEILING FAN. SURFACE MOUNTED FIXTURE TO MATCH 605. PROVIDE SEPARATE LINE ITEM FOR BUYER COST. VANITY SCONCE PROVIDED AND INSTALLED BY BUYER. FIRE ALARM STROBE AND SPEAKER. 6" CAN LIGHT TO BE: CREE, CR6-800L-27K-12-E26. PROVIDE SEPARATE LINE ITEM COST FOR BUYER ABOVE (35) LIGHT ALLOWANCE. PENDANT LIGHT FIXTURE PROVIDED AND INSTALLED BY BUYER. FIRE ALARM SMOKE DETECTOR. OPEN CEILING HEIGHT. DRYWALL CEILINGS. EXHAUST FAN TO MATCH 605. SERVICE PANEL. AREA OF GAS LINE ACCESS PANEL, REF. 9/A103 FOR PRODUCT INFORMATION. GENERAL CEILING NOTES: ALL WALLS GO TO FINISHED CEILING UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 1. 3. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS.4. 2.CEILING HEIGHT DESIGNATED BY BENCHMARK ABOVE FINISHED FLOOR (AFF). CEILING PLAN NOTES: CP1 CP2 ADJUST THE HEIGHT OF EXISTING FIRE SUPPRESSION LINES, ROOF DRAIN LEADERS, ROOF STACK VENTS AND CONDENSATE LINES TO ALLOW FOR CEILING HEGHTS AS INDICATED ON THE REFLECTED CEILING PLAN. 5. REPLACE GAS LINE W/ APPROVED ASSEMBLY ALLOWED IN CONCEALED AREAS. PROVIDE FIRE TREATED BLOCKING AT WALLS FOR ATTACHMENT OF PAINTED CROWN MOLDING AND PICTURE RAIL WHERE NECESSARY. REFER TO REFLECTED CEILING PLAN FOR THOSE LOCATIONS. 6. 7. PAINTED DRYWALL TRAY CEILING, SEE DETAIL X/XXX. CP6 CP7 CP4 CP5 CP3 LOCATE HVAC UNIT(S) AT THIS LOCATION. PROVIDE POWER FOR LIGHTS. LIGHTS PROVIDED AND INSTALLED BY BUYER. CONTROL JOINT. INSTALL LIGHTS AND EXHAUST FANS WITH 'R' TO BE REUSED FROM UNIT 605. DRYWALL BULKHEAD, SEE DETAIL X/XXX. NOT USED. PROVIDE FIREPROOF MATERIALS/DRY PENDANT OVERHEAD FOR GRILL AREA AS BUYER COST.CP8 PROVIDE LIFE SAFETY ITEMS AS REQUIRED. COLOR TO BE WHITE.CP9 PROVIDE SEPARATE BUYER COST FOR DOWNLIGHTS ABOVE (35) LIGHT ALLOWANCE.CP10 PROVIDE SEPARATE BUYER COST FOR SURFACE MOUNT LIGHTS. LIGHTS TO MATCH 605..CP11 CA R M E L C I T Y C E N T E R - B U I L D I N G A CO N D O M I N I U M U N I T 6 0 3 - 6 0 5 72 0 S . R a n g e l i n e R o a d Ca r m e l , I n 4 6 0 3 2 P QP.5P QP.5 SD SD SD SD SD 4'-5 1/4"6'-0"6'-0"4'-5 1/4" 6' - 0 " 6'- 0 " 6'- 1 1 / 8 " 6'- 0 " 6'- 1 1 / 8 " 6'-0"4'-5 1/4" 3'-0" 2'- 4 5 / 8 " 4'- 0 " 2' - 4 1 / 2 " 8'-0"3'-8 3/4" 6' - 0 " 1'- 5 3 / 8 " 3'- 1 " 5' - 8 5 / 8 " 1' - 4 1 / 4 " 6' - 7 3 / 4 " 1'- 6 " 1'-7 1/2"3'-10 1/2"4'-0"2'-6 3/4" 4' - 0 " 4' - 0 " 4' - 1 1 / 2 " 2'- 1 3 / 8 " 3'-1"5'-0" 6'-0" 6'-0" 2'-3" 4'-2 1/4"4'-2 1/4" 3' - 7 7 / 8 " 6'-0"6'-0"4'-10 3/4" 3' - 0 " 8' - 0 " 4'- 0 " 4'-1"2'-0 3/8" 1'-4"4'-0"1'-4" 3'-2 5/8"3'-2 5/8" 4'-0"4'-0"7'-3 1/4" 4 7 / 8 " 3' - 1 1 / 8 " 4'- 0 " 8' - 6 5 / 8 " 4' - 6 1 / 2 " EQ . 4' - 0 " EQ . 4'-0"4'-0" 2' - 0 " 1'-4 1/2"4'-0"4'-0" 2'-0" 8' - 3 1 / 4 " A F F 8' - 3 1 / 4 " A F F 9'-0" AFF 9'-0" AFF 9'-0"AFF 10'-0" AFF 9'-0" AFF 8'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0"AFF 9'-0" AFF 9'-0" AFF 8'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 8'-0" AFF 8'-0" AFF 8'-0" AFF 8'-0" AFF 8'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF 9'-0" AFF9'-0" AFF CP9 CP5 CP1 CP2 CP9 CP3 CP5 CP2 CP2 CP2 CP2 CP2 CP5 CP5 CP9 CP9 CP5 CP5 CP5 CP5 CP5 CP5 CP5 CP2 SCALE: 1/4" = 1'-0" 1 REFLECTED CEILING PLAN A101C 0 2'4'8'